Comparative Effectiveness and Safety of Methods of Insulin Delivery and Glucose Monitoring for Diabetes Mellitus: A Systematic Review and Meta-analysis
Open accessThe DOI matches its Crossref record; 75 of the 75 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Patients with diabetes mellitus need information about the effectiveness of innovations in insulin delivery and glucose monitoring. PURPOSE: To review how intensive insulin therapy (multiple daily injections [MDI] vs. rapid-acting analogue-based continuous subcutaneous insulin infusion [CSII]) or method of monitoring (self-monitoring of blood glucose [SMBG] vs. real-time continuous glucose monitoring [rt-CGM]) affects outcomes in types 1 and 2 diabetes mellitus. DATA SOURCES: MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials through February 2012 without language restrictions. STUDY SELECTION: 33 randomized, controlled trials in children or adults that compared CSII with MDI (n=19), rt-CGM with SMBG (n=10), or sensor-augmented insulin pump use with MDI and SMBG (n=4). DATA EXTRACTION: 2 reviewers independently evaluated studies for eligibility and quality and serially abstracted data. DATA SYNTHESIS: In randomized, controlled trials, MDI and CSII showed similar effects on hemoglobin A1c (HbA1c) levels and severe hypoglycemia in children or adults with type 1 diabetes mellitus and adults with type 2 diabetes mellitus. In adults with type 1 diabetes mellitus, HbA1c levels decreased more with CSII than with MDI, but 1 study heavily influenced these results. Compared with SMBG, rt-CGM achieved a lower HbA1c level (between-group difference of change, 0.26% [95% CI, 0.33% to 0.19%]) without any difference in severe hypoglycemia. Sensor-augmented insulin pump use decreased HbA1c levels more than MDI and SMBG did in persons with type 1 diabetes mellitus (between-group difference of change, 0.68% [CI, 0.81% to 0.54%]). Little evidence was available on other outcomes. LIMITATION: Many studies were small, of short duration, and limited to white persons with type 1 diabetes mellitus. CONCLUSION: Continuous subcutaneous insulin infusion and MDI have similar effects on glycemic control and hypoglycemia, except CSII has a favorable effect on glycemic control in adults with type 1 diabetes mellitus. For glycemic control, rt-CGM is superior to SMBG and sensor-augmented insulin pumps are superior to MDI and SMBG without increasing the risk for hypoglycemia. PRIMARY FUNDING SOURCE: Agency for Healthcare Research and Quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Rates and the clinical impact of hypoglycemia are frequently underestimated,1108”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
In the citing paper
“The frequency of hypoglycemia increases with intensive insulin targets, use of SUs, decreased caloric intake, delayed meals, exercise, alcohol consumption, CKD, T2D duration, and cognitive impairment.1108”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
In the citing paper
“but about 7% to 15% of insulin-treated persons with T2D experience at least 1 episode of hypoglycemia per year,1109 and 1% to 2% have severe hypoglycemia.1106,1108”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
In the citing paper
“Hyperinsulinemia, increased alcohol intake, starvation, and organ failure may be aggravating factors.1108,1200,1201”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
In the citing paper
“In persons with DM, iatrogenic hypoglycemia stems from an imbalance among insulin and/or insulinogenic (eg, SUs, glinides) therapy and food intake, physical activity, organ function (gluconeogenesis), and counter-regulation with glucagon and/or epinephrine (hypoglycemia-associated autonomic failure).”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
6 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., & Altman, D. G. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.06.005 · Cited by 19,575
Reduction in the incidence of type 2 diabetes with lifestyle intervention or metformin
(2002) · New England Journal of Medicine · doi:10.1056/nejmoa012512 · Cited by 19,011
Turner, R. C., Fox, C., Matthews, McElroy, H. H., Cull, C. A., Holman, R. R., Neil, P., Hadden, D. R., Wright, D., Manley, E., et al. (1998) · The Lancet · Cited by 8,419
Downs, S. H., & Black, N. (1998) · Journal of Epidemiology and Community Health · doi:10.1136/jech.52.6.377 · Cited by 8,252
Research works printed but not linked: 2
- 20587584N Engl J Med. 363N Engl J Med. 2010;363:383-4. [PMID: 20587584]
- Diabetes Prevention Program Research Group. Reduction in domized treat-to-target study. W C Knowler, E Barrett-Connor, S E Fowler, R F Hamman, J M Lachin, E A Walker, 18715214Diabetes Technol Ther. 10Knowler WC, Barrett-Connor E, Fowler SE, Hamman RF, Lachin JM, Walker EA, et al; Diabetes Prevention Program Research Group. Reduction in domized treat-to-target study. Diabetes Technol Ther. 2008;10:377-83. [PMID: 18715214]
Cited by
Items 101–200 of 492
Chamberlain, J. J., Kalyani, R. R., Leal, S., Rhinehart, A. S., Shubrook, J. H., Skolnik, N., & Herman, W. H. (2017) · Annals of Internal Medicine · doi:10.7326/m17-1259 · Cited by 61
Freckmann, G., Buck, S., Waldenmaier, D., Kulzer, B., Schnell, O., Gelchsheimer, U., Ziegler, R., & Heinemann, L. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820928100 · Cited by 74
New Approaches to Providing Individualized Diabetes Care in the 21st Century
Powell, P., Corathers, S., Raymond, J., & Streisand, R. (2015) · Current Diabetes Reviews · doi:10.2174/1573399811666150421110316 · Cited by 60
Mameli, C., Scaramuzza, A. E., Ho, J., Cardona‐Hernandez, R., Suárez-Ortega, L., & Zuccotti, G. (2013) · Acta Diabetologica · doi:10.1007/s00592-013-0481-y · Cited by 63
“sensor-augmented pump [8], long-term (over 4 years) fol-”
MethodResultMcCance, D. R. (2015) · Best Practice & Research Clinical Obstetrics & Gynaecology · doi:10.1016/j.bpobgyn.2015.04.009 · Cited by 96
Thabit, H., & Hovorka, R. (2016) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2016.1115013 · Cited by 58
“20)] and was comparable among adolescents >12 years and children <12 years.[41] A criticism of most comparative studies and meta-analyses is the inclusion of MDI participants not on a recommended analogue-based basal-bolus MDI regimen as comparator for CSII (see Table 1).”
BackgroundMethodInfluentialIqbal, A., & Heller, S. R. (2016) · Best Practice & Research Clinical Endocrinology & Metabolism · doi:10.1016/j.beem.2016.06.004 · Cited by 66
Routine use of continuous glucose monitoring in 10 501 people with diabetes mellitus
Battelino, T., Liabat, S., Veeze, H. J., Castañeda, J., Arrieta, A., & Cohen, O. (2015) · Diabetic Medicine · doi:10.1111/dme.12825 · Cited by 57
Rosner, B., & Román-Urrestarazu, A. (2019) · PLoS ONE · doi:10.1371/journal.pone.0217655 · Cited by 67
The Evidence Base for Diabetes Technology: Appropriate and Inappropriate Meta-Analysis
Pickup, J. C. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700617 · Cited by 56
Hypoglycemia Reduction and Changes in Hemoglobin A1c in the ASPIRE In-Home Study
Weiss, R., Garg, S. K., Bode, B. W., Bailey, T. S., Ahmann, A. J., Schultz, K. A., Welsh, J. B., Shin, J. J., & for the ASPIRE In-Home Study Group (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0306 · Cited by 56
Beato‐Víbora, P., Yeoh, E., Rogers, H., Hopkins, D., Amiel, S. A., & Choudhary, P. (2015) · Diabetic Medicine · doi:10.1111/dme.12869 · Cited by 55
An insight into biomimetic 4D printing
Kanu, N. J., Gupta, E., Vates, U. K., & Singh, G. K. (2019) · RSC Advances · doi:10.1039/c9ra07342f · Cited by 56
Jendle, J., Pöhlmann, J., de Portu, S., Smith-Palmer, J., & Roze, S. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0328 · Cited by 52
Technology Integration: The Role of the Diabetes Care and Education Specialist in Practice
Isaacs, D., Cox, C., Schwab, K., Oser, T. K., Rinker, J., Mason, M. J., Greenwood, D. A., & Albanese-O’Neill, A. (2020) · The Diabetes Educator · doi:10.1177/0145721720935123 · Cited by 53
Choudhary, P., & Amiel, S. A. (2018) · Diabetologia · doi:10.1007/s00125-018-4566-6 · Cited by 52
4D printing: Pragmatic progression in biofabrication
Sonatkar, J., Kandasubramanian, B., & Ismail, S. O. (2022) · European Polymer Journal · doi:10.1016/j.eurpolymj.2022.111128 · Cited by 54
“…when a particular SMP hydrogels responses to a specific stimuli, they could endure configurational changes based on the gradation of inflation [37]. protuberant type of resources, as a result of their capacity to remember the form automated to them, termed as shape memory effect (SME) with…”
Hypoglycemia in Patients with Type 1 Diabetes: Epidemiology, Pathogenesis, and Prevention
Awoniyi, O., Rehman, R., & Dagogo-Jack, S. E. (2013) · Current Diabetes Reports · doi:10.1007/s11892-013-0411-y · Cited by 59
Tight glycemic control in critically ill pediatric patients: a systematic review and meta-analysis
Chen, L., Li, T., Fang, F., Zhang, Y., & Faramand, A. M. (2018) · Critical Care · doi:10.1186/s13054-018-1976-2 · Cited by 53
“Continuous glucose monitoring has been shown to be safe and effective in children and adults, and may assist in the safer provision of tight glycemic control, with less hypoglycemia [24].”
BackgroundContinuous Glucose Monitoring with Multiple Daily Insulin Treatment: Outcome Studies
McGill, J. B., & Ahmann, A. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0090 · Cited by 49
Islet Microencapsulation: Strategies and Clinical Status in Diabetes
Omami, M., McGarrigle, J. J., Reedy, M. B., Isa, D., Ghani, S., Marchese, E., Bochenek, M. A., Longi, M., Xing, Y., Joshi, I., et al. (2017) · Current Diabetes Reports · doi:10.1007/s11892-017-0877-0 · Cited by 52
Abolhassani, S., Fattahi, R., Safshekan, F., Saremi, J., & Hasanzadeh, E. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202403065 · Cited by 60
Borot, S., Franc, S., Cristante, J., Penfornis, A., Benhamou, P.-Y., Guerci, B., Hanaire, H., Renard, E., Reznik, Y., Simon, C., et al. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814543946 · Cited by 47
Wearable systems and mobile applications for diabetes disease management
Georga, E. I., Protopappas, V. C., Bellos, C. V., & Fotiadis, D. I. (2014) · Health and Technology · doi:10.1007/s12553-014-0082-y · Cited by 53
“Hirch [37] comments on the outcomes of two recent meta-analyses [35, 36], which reported contradictory results regarding the effect of CSII therapy on severe hypoglycemia reduction in both type 1 adults and children, that “has added uncertainty to our original premise about this therapy”.”
BackgroundResultManagement of diabetes complications in youth
Graves, L. E., & Donaghue, K. C. (2019) · Therapeutic Advances in Endocrinology and Metabolism · doi:10.1177/2042018819863226 · Cited by 60
Dicembrini, I., Mannucci, E., Monami, M., & Pala, L. (2019) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.13845 · Cited by 46
Rachmiel, M., Landau, Z., Boaz, M., Aronovitch, K. M., Loewenthal, N., Ben‐Ami, M., Levy‐Shraga, Y., Modan‐Moses, D., Haim, A., Abiri, S., et al. (2014) · Acta Diabetologica · doi:10.1007/s00592-014-0643-6 · Cited by 51
James, S., Perry, L., Gallagher, R., & Lowe, J. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816660326 · Cited by 44
Interventions for Diabetic Retinopathy in Type 1 Diabetes: Systematic Review and Meta-Analysis
Virk, S. A., Donaghue, K. C., Wong, T. Y., & Craig, M. E. (2015) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2015.07.024 · Cited by 52
The History, Evolution and Future of Continuous Glucose Monitoring (CGM)
Bender, C., Vestergaard, P., & Cichosz, S. L. (2025) · Diabetology · doi:10.3390/diabetology6030017 · Cited by 43
“Numerous studies have shown the benefits such as reducing HbA1c, hyper-/hypoglycemia, effects on quality of life and the safety of using CGM [59–62].”
Injectable hydrogels for islet transplantation: a concise review
Shrestha, P. S., Regmi, S., & Jeong, J. (2019) · Journal of Pharmaceutical Investigation · doi:10.1007/s40005-019-00433-3 · Cited by 45
“However, poor control of blood glucose fluctuations with accompanying complications such as neuropathy, nephropathy, retinopathy, heart disease, and atherosclerosis have forced to find alternative means of treatment (Grajower 2018; Yeh et al. 2012).”
BackgroundRanasinghe, P. D., Maruthur, N. M., Nicholson, W. K., Yeh, H., Brown, T. T., Suh, Y. D., Wilson, L. M., Nannes, E. B., Berger, Z. D., Bass, E. B., et al. (2015) · Journal of Women s Health · doi:10.1089/jwh.2014.4939 · Cited by 47
Self-citationNg, S. M., Moore, H. S., Clemente, M., Pintus, D., & Soni, A. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0347 · Cited by 52
Cichosz, S. L., Jensen, M. H., & Hejlesen, O. K. (2021) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2021.104472 · Cited by 46
Chesser, H., Srinivasan, S., Puckett, C., Gitelman, S. E., & Wong, J. C. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221139873 · Cited by 40
Barriers and Facilitators to Diabetes Device Adoption for People with Type 1 Diabetes
Tanenbaum, M. L., & COMMISSARIAT, P. V. (2022) · Current Diabetes Reports · doi:10.1007/s11892-022-01469-w · Cited by 50
Health‐economic analysis of real‐time continuous glucose monitoring in people with Type 1 diabetes
Roze, S., Saunders, R., Brandt, A. ‐., de Portu, S., Papo, N. L., & Jendle, J. (2015) · Diabetic Medicine · doi:10.1111/dme.12661 · Cited by 40
Ehrmann, D., Kulzer, B., Schipfer, M., Lippmann-Grob, B., Haak, T., & Hermanns, N. (2018) · Diabetes Care · doi:10.2337/dc18-0917 · Cited by 40
Sinclair, A. J., Dunning, T. L., Dhatariya, K., & an International Group of Experts (2019) · Diabetic Medicine · doi:10.1111/dme.14135 · Cited by 46
Karamanakos, G., Kokkinos, A. D., Dalamaga, Μ., & Liatis, S. (2022) · Current Obesity Reports · doi:10.1007/s13679-022-00477-x · Cited by 49
Limitations of Continuous Glucose Monitor Usage
Anhalt, H. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0011 · Cited by 39
Lucidi, P., Porcellati, F., Bolli, G. B., & Fanelli, C. G. (2018) · Current Diabetes Reports · doi:10.1007/s11892-018-1065-6 · Cited by 38
Markowitz, J. T., Alleyn, C., Phillips, R., MUIR, A. B., Young-Hyman, D. L., & Laffel, L. M. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0008 · Cited by 44
Bronstone, A., & Graham, C. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816633233 · Cited by 38
Health‐related quality of life of adolescents with type 1 diabetes in the context of resilience
Lukács, A., Mayer, K., Sasvári, P., & Barkai, L. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12769 · Cited by 51
New and Emerging Technologies in Type 1 Diabetes
Sherwood, J. S., Russell, S. J., & Putman, M. S. (2020) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2020.07.006 · Cited by 50
“Diabetes technology holds promise for improving glycemic outcomes and decreasing burden of disease for patients and families with T1D.”
BackgroundInfluentialKang, S., Kang, S. M., Choi, J. H., Ko, S., Koo, B. K., Kwon, H.-S., Kim, M. K., Kim, S. Y., Kim, S., Kim, Y., et al. (2025) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2025.0469 · Cited by 85
Roze, S., Smith-Palmer, J., Valentine, W., Payet, V., de Portu, S., Papo, N., Cucherat, M., & Hanaire, H. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0224 · Cited by 37
Leveraging advances in diabetes technologies in primary care: a narrative review
Bode, B. W., King, A., Russell-Jones, D. L., & Billings, L. K. (2021) · Annals of Medicine · doi:10.1080/07853890.2021.1931427 · Cited by 46
Overcoming barriers in clinical islet transplantation: Current limitations and future prospects
Chhabra, P., Sutherland, D. E. R., & Brayman, K. L. (2013) · Current Problems in Surgery · doi:10.1067/j.cpsurg.2013.10.002 · Cited by 45
Maiorino, M. I., Bellastella, G., Petrizzo, M., Improta, M. R., Brancario, C., Castaldo, F., Olita, L., Giugliano, D., & Esposito, K. (2013) · Endocrine · doi:10.1007/s12020-013-0060-6 · Cited by 42
Glycemic Management in Adults With Type 1 Diabetes
McGibbon, A., Adams, L., Ingersoll, K. S., Kader, T., & Tugwell, B. D. (2018) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2017.10.012 · Cited by 63
Real-World Implications of Hybrid Close Loop (Hcl) Insulin Delivery System
Faulds, E. R., Zappe, J., & Dungan, K. M. (2019) · Endocrine Practice · doi:10.4158/ep-2018-0515 · Cited by 37
Seget, S., Jarosz-Chobot, P. A., Ochab, A., Polańska, J., Rusak, E., Witoszek, P., & Chobot, A. P. (2022) · Frontiers in Endocrinology · doi:10.3389/fendo.2022.1036808 · Cited by 39
Inducible Pluripotent Stem Cells as a Potential Cure for Diabetes
Verhoeff, K., Henschke, S. J., Marfil-Garza, B. A., Dadheech, N., & Shapiro, A. M. J. (2021) · Cells · doi:10.3390/cells10020278 · Cited by 34
Maiorino, M. I., Bellastella, G., Casciano, O., Cirillo, P., Simeon, V., Chiodini, P., Petrizzo, M., Gicchino, M., Romano, O., Caruso, P., et al. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0334 · Cited by 39
Risk factors and prevalence of diabetic retinopathy: A protocol for meta-analysis
Hou, Y., Cai, Y., Jia, Z., & Shi, S. (2020) · Medicine · doi:10.1097/md.0000000000022695 · Cited by 46
“Long-term metabolic disorders can lead to microvascular and macrovascular diseases, neurological complications, etc.([1]) With the substantial improvement of people’s living standards, changes in eating habits and lifestyles, the number of people suffering from diabetes (Diabetes mellitus, DM) is also increasing year…”
BackgroundGarcía‐Lorenzo, B., Rivero‐Santana, A., Vallejo‐Torres, L., Castilla‐Rodríguez, I., García‐Pérez, S., García‐Pérez, L., & Perestelo‐Pérez, L. (2018) · Journal of Evaluation in Clinical Practice · doi:10.1111/jep.12987 · Cited by 39
Clinical approaches to treat impaired awareness of hypoglycaemia
Farrell, C. M., & McCrimmon, R. J. (2021) · Therapeutic Advances in Endocrinology and Metabolism · doi:10.1177/20420188211000248 · Cited by 31
Jeihooni, A. K., Askari, A., Kashfi, S. M., Marzban, A., & Khiyali, Z. (2018) · International Journal of Preventive Medicine · doi:10.4103/ijpvm.ijpvm_308_16 · Cited by 33
Alderisio, A., Bozzetto, L., Franco, L., Riccardi, G., Rivellese, A. A., & Annuzzi, G. (2019) · Nutrition Metabolism and Cardiovascular Diseases · doi:10.1016/j.numecd.2019.06.008 · Cited by 36
Dover, A. R., Strachan, M. W. J., McKnight, J. A., Stimson, R. H., Mackenzie, S. D., Lyall, M. J., Wright, R. J., Forbes, S., & Gibb, F. W. (2020) · Diabetic Medicine · doi:10.1111/dme.14445 · Cited by 33
Roze, S., Buompensiere, M. I., Ozdemir, Z., de Portu, S., & Cohen, O. (2021) · Journal of Medical Economics · doi:10.1080/13696998.2021.1939706 · Cited by 30
Capel, I., Rigla, M., García-Sáez, G., Rodríguez-Herrero, A., Pons, B., Subías, D., García-García, F., Gallach, M., Aguilar, M., Pérez-Gandía, C., et al. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0229 · Cited by 29
Joshi, M., & Choudhary, P. (2015) · Current Diabetes Reports · doi:10.1007/s11892-015-0644-z · Cited by 32
Mehrdad, M., Azarian, M., Sharafkhaneh, A., Foumani, A. A., Zare, R., Rad, A. H., & Dalili, S. (2021) · Intern J Endocrinol Metab · doi:10.5812/ijem.118077 · Cited by 36
Personalized nutrition for people with diabetes and at risk of diabetes has begun
Chen, R. E., & Chen, G. (2022) · Journal of Future Foods · doi:10.1016/j.jfutfo.2022.06.001 · Cited by 35
A Modular Safety System for an Insulin Dose Recommender: A Feasibility Study
Liu, C., Avari, P., Leal, Y., Wos, M., Sivasithamparam, K., Georgiou, P., Reddy, M., Fernández‐Real, J. M., Martin, C. E., Fernández-Balsells, M., et al. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819851135 · Cited by 34
Aronson, R., Brown, R. E., Abitbol, A., Goldenberg, R., Yared, Z., Ajala, B., & Yale, J.-F. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0204 · Cited by 27
Warshaw, H. S., Isaacs, D. M., & MacLeod, J. (2020) · The Science of Diabetes Self-Management and Care · doi:10.1177/0145721720930183 · Cited by 29
“In addition, research shows only modest advantages of CSII in glycemic management among varied populations.(25,26) A 3-year, nonrandomized, prospective, realworld clinical trial (COMISAIR study) in adults with T1DM (N = 94) assessed 4 management plans: (1) realtime CGM with MDI, (2) real-time CGM with CSII,”
BackgroundJENDLE, J. H., Eeg‐Olofsson, K., Svensson, J., Franzén, S., Lamotte, M., & Levrat‐Guillen, F. (2021) · Diabetes Therapy · doi:10.1007/s13300-021-01172-1 · Cited by 32
Current Concepts of Using Pigs as a Source for Beta-Cell Replacement Therapy of Type 1 Diabetes
Klymiuk, N., Ludwig, B., Seißler, J., Reichart, B., & Wolf, E. (2016) · Current Molecular Biology Reports · doi:10.1007/s40610-016-0039-1 · Cited by 27
Larose, S., RABASA-LHORET, R. P. R., Roy‐Fleming, A., Suppère, C., Tagougui, S., Messier, V., & Taleb, N. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0400 · Cited by 31
Ehrmann, D., Heinemann, L., Freckmann, G., Waldenmaier, D., Faber-Heinemann, G., & Hermanns, N. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0332 · Cited by 27
Ghosh, S., Chaudhuri, S., Roy, P., & Lahiri, D. (2022) · Regenerative Engineering and Translational Medicine · doi:10.1007/s40883-022-00288-5 · Cited by 32
“Hence, there is an urgent need of developing glucose responsive material for their practical application in glucose sensing, monitoring, and delivery of insulin [129, 130].”
BackgroundÖzcan, Ş., Amiel, S. A., Rogers, H., Choudhary, P., Cox, A., de Zoysa, N., Hopkins, D., & Forbes, A. (2014) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2014.07.023 · Cited by 28
The rise of technology in diabetes care. Not all that is new is necessarily better
Acerini, C. L. (2016) · Pediatric Diabetes · doi:10.1111/pedi.12366 · Cited by 28
Gomes, M. B., Rodacki, M., Pavin, E. J., Cobas, R. A., Felicio, J. S., Zajdenverg, L., & Negrato, C. A. (2017) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2017.09.013 · Cited by 26
Schuster, K. M., Barre, K., Inzucchi, S. E., Udelsman, R., & Davis, K. A. (2014) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0000000000000127 · Cited by 29
“CGM is now a well-established adjunct to self-monitored blood glucose in the outpatient care of diabetic patients, where it has been shown to reduce hemoglobin A1C levels but not necessarily impact the incidence of hypoglycemia.(8) In the critical care setting, subcutaneous CGM has been shown to be accurate in medical…”
BackgroundSchiaffini, R., Tagliente, I., Carducci, C., Ullmann, N., Ciampalini, P., Lorubbio, A., & Cappa, M. (2015) · Journal of Telemedicine and Telecare · doi:10.1177/1357633x15598425 · Cited by 25
Taleb, N., Messier, V., Ott-Braschi, S., Ardilouze, J.-L., & Rabasa-Lhoret, R. (2018) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2018.07.035 · Cited by 25
A clinical review of the t:slim X2 insulin pump
Berget, C., Lange, S. L., Messer, L. H., & Forlenza, G. P. (2020) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2020.1814734 · Cited by 27
Leblanc, V., Hamroun, A., Bentegeac, R., Guellec, B. L., Lenain, R., & Chazard, E. (2024) · Journal of Medical Internet Research · doi:10.2196/53781 · Cited by 32
Gill, M., Zhu, C., Shah, M., & Chhabra, H. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818777265 · Cited by 27
“A meta-analysis comparing the effectiveness of rtCGM and SMBG supported the superiority of rtCGM in lowering glycated hemoglobin (A1C) levels in patients with type 1 diabetes mellitus (T1DM), without increasing the risk of severe hypoglycemia.(11) More recently, two randomized clinical trials comparing the use of rtCG…”
BackgroundKamusheva, M., Tachkov, K., Dimitrova, M. J., Mitkova, Z. E., García-Sáez, G., Hernando, M. E., Goettsch, W., & Petrova, G. I. (2021) · Frontiers in Endocrinology · doi:10.3389/fendo.2021.636959 · Cited by 32
2021 Clinical Practice Guidelines for Diabetes Mellitus in Korea
Ko, S. (2021) · Journal of Korean Diabetes · doi:10.4093/jkd.2021.22.4.244 · Cited by 23
Serné, E. H., Roze, S., Buompensiere, M. I., Valentine, W. J., de Portu, S., & de Valk, H. W. (2022) · Advances in Therapy · doi:10.1007/s12325-022-02058-9 · Cited by 28
Mezquita‐Raya, P., Reyes‐García, R., Moreno, Ó., Muñoz‐Torres, M., Merino-Torres, J. F., Martínez, J. J. G., Jódar-Gimeno, E., Escalada, J., Gargallo-Fernández, M., Soto-González, A., et al. (2013) · Endocrinología y Nutrición · doi:10.1016/j.endonu.2013.04.005 · Cited by 32
Crenier, L., Abou-Elias, C., & Corvilain, B. (2013) · Diabetes Care · doi:10.2337/dc12-2058 · Cited by 27
“While some trials or meta-analyses showed a reduction in severe (requiring third-party assistance) (11) and nonsevere (5) hypoglycemic episodes on CSII compared with MDI, others did not (6,7,10,12) or even reported a higher rate of mild hypoglycemic events compared with MDI (13).”
BackgroundClosed-loop insulin delivery: current status of diabetes technologies and future prospects
Majeed, W., & Thabit, H. (2018) · Expert Review of Medical Devices · doi:10.1080/17434440.2018.1503530 · Cited by 27
“options include multiple daily injections (MDI) of insulin or continuous subcutaneous insulin infusion (CSII), also known as the ‘insulin pump’ [5].”
BackgroundSelf-measurement of Blood Glucose and Continuous Glucose Monitoring – Is There Only One Future?
Heinemann, L., & Stuhr, A. (2018) · touchREVIEWS in Endocrinology · doi:10.17925/ee.2018.14.2.24 · Cited by 30
Aronson, R., Cohen, O., Conget, I., Runzis, S., Castañeda, J., de Portu, S., Lee, S., Reznik, Y., & for the OpT2mise Study Group (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0363 · Cited by 26
Banting Memorial Lecture 2014 Technology and diabetes care: appropriate and personalized
Pickup, J. C. (2014) · Diabetic Medicine · doi:10.1111/dme.12613 · Cited by 22
Insulin pump therapy in youth with type 1 diabetes: toward closed-loop systems
Tauschmann, M., & Hovorka, R. (2014) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2014.910192 · Cited by 24
“[28] documented no difference after 16 or more weeks of follow-up.”
BackgroundGrunberger, G., Bailey, T. S., Camacho, P. M., EINHORN, D. F., Garber, A. J., Handelsman, Y., Harrell, R. M., Lando, H. M., Law, B., Leffert, J. D., et al. (2015) · Endocrine Practice · doi:10.4158/ep15653.cs · Cited by 22
the Italian Study Group on Diffusion of CSII in Italy, Bonfanti, R., Lepore, G., Bozzetto, L., Corsi, A., Blasi, V. D., Girelli, A., Grassi, G., Iafusco, D., Rabbone, I., et al. (2015) · Acta Diabetologica · doi:10.1007/s00592-015-0810-4 · Cited by 24
Hypoglycemia During Therapy of Diabetes
Spanakis, E. K., Cryer, P. E., & Davis, S. N. (2015) · Europe PMC (PubMed Central) · Cited by 21
Wan, W., Skandari, M. R., Minc, A., Nathan, A. G., Zarei, P., Winn, A. N., O’Grady, M. J., & Huang, E. S. (2018) · Medical Decision Making · doi:10.1177/0272989x18803109 · Cited by 26
“Inappropriate insulin dosing has been found to be one of the key driving factors of suboptimal glycemic control.5 Intensive insulin therapy can be delivered by multiple daily injection (MDI) or an insulin pump with continuous subcutaneous insulin infusion (CSII).6,7 Accompanying blood glucose monitoring can be achieve…”
InfluentialYu, X., Yang, Z., Sun, X., Liu, H., Li, H., Lu, J., Zhou, J. H., & Çınar, A. (2025) · AI · doi:10.3390/ai6050087 · Cited by 31
“Moreover, AIDs have been shown to have a modest advantage in reducing the incidence of severe hypoglycemia (BGC 54 mg/dL) in children and adults [15].”
Zou, Y. L., Zhao, S., Li, G., & Zhang, C. (2022) · Journal of General Internal Medicine · doi:10.1007/s11606-022-07864-z · Cited by 27
Metadata
- Authors
- Yeh, H.-C., Brown, T. T., Maruthur, N., Ranasinghe, P., Berger, Z., Suh, Y. D., Wilson, L. M., Haberl, E. B., Brick, J., Bass, E. B., & Golden, S. H.
- Affiliations
- Johns Hopkins University (US)
- Harvard University (US)
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2012-09-04
- Volume
- 157
- Issue
- 5
- Pages
- 336-347
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2035018400
- Semantic Scholar
- 6a9836e0bc9a84e7b30be275ad35b904df13faab
- Cited by
- 493
- References
- 72
- Citations by year
- 2026: 14 · 2025: 15 · 2024: 27 · 2023: 19 · 2022: 31 · 2021: 38 · 2020: 45 · 2019: 44 · 2018: 48 · 2017: 36 · 2016: 48 · 2015: 46 · 2014: 48 · 2013: 32 · 2012: 2
- FWCI
- 5.63
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by-nc-nd
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Repositorio UTB (submittedVersion, cc-by-nc-nd)
- Funders
- National Institute of Diabetes and Digestive and Kidney Diseases (P30DK079637)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- diabetes mellitus, insulin delivery, insulin pump therapy, multiple daily insulin injections, sensor-augmented pump, continuous glucose monitoring, self-monitoring of blood glucose, glycemic control, HbA1c, hypoglycemia, type 1 diabetes, type 2 diabetes, intensive insulin therapy, rapid-acting insulin analogs, children and adults, comparative effectiveness
- MeSH terms
- Blood Glucose, Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2, Glycated Hemoglobin, Humans, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Monitoring, Physiologic, Blood Glucose Self-Monitoring, Treatment Outcome, Comparative Effectiveness Research
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.