Comparative Effectiveness and Safety of Methods of Insulin Delivery and Glucose Monitoring for Diabetes Mellitus: A Systematic Review and Meta-analysis
Open accessThe DOI matches its Crossref record; 75 of the 75 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Patients with diabetes mellitus need information about the effectiveness of innovations in insulin delivery and glucose monitoring. PURPOSE: To review how intensive insulin therapy (multiple daily injections [MDI] vs. rapid-acting analogue-based continuous subcutaneous insulin infusion [CSII]) or method of monitoring (self-monitoring of blood glucose [SMBG] vs. real-time continuous glucose monitoring [rt-CGM]) affects outcomes in types 1 and 2 diabetes mellitus. DATA SOURCES: MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials through February 2012 without language restrictions. STUDY SELECTION: 33 randomized, controlled trials in children or adults that compared CSII with MDI (n=19), rt-CGM with SMBG (n=10), or sensor-augmented insulin pump use with MDI and SMBG (n=4). DATA EXTRACTION: 2 reviewers independently evaluated studies for eligibility and quality and serially abstracted data. DATA SYNTHESIS: In randomized, controlled trials, MDI and CSII showed similar effects on hemoglobin A1c (HbA1c) levels and severe hypoglycemia in children or adults with type 1 diabetes mellitus and adults with type 2 diabetes mellitus. In adults with type 1 diabetes mellitus, HbA1c levels decreased more with CSII than with MDI, but 1 study heavily influenced these results. Compared with SMBG, rt-CGM achieved a lower HbA1c level (between-group difference of change, 0.26% [95% CI, 0.33% to 0.19%]) without any difference in severe hypoglycemia. Sensor-augmented insulin pump use decreased HbA1c levels more than MDI and SMBG did in persons with type 1 diabetes mellitus (between-group difference of change, 0.68% [CI, 0.81% to 0.54%]). Little evidence was available on other outcomes. LIMITATION: Many studies were small, of short duration, and limited to white persons with type 1 diabetes mellitus. CONCLUSION: Continuous subcutaneous insulin infusion and MDI have similar effects on glycemic control and hypoglycemia, except CSII has a favorable effect on glycemic control in adults with type 1 diabetes mellitus. For glycemic control, rt-CGM is superior to SMBG and sensor-augmented insulin pumps are superior to MDI and SMBG without increasing the risk for hypoglycemia. PRIMARY FUNDING SOURCE: Agency for Healthcare Research and Quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Rates and the clinical impact of hypoglycemia are frequently underestimated,1108”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
In the citing paper
“The frequency of hypoglycemia increases with intensive insulin targets, use of SUs, decreased caloric intake, delayed meals, exercise, alcohol consumption, CKD, T2D duration, and cognitive impairment.1108”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
In the citing paper
“but about 7% to 15% of insulin-treated persons with T2D experience at least 1 episode of hypoglycemia per year,1109 and 1% to 2% have severe hypoglycemia.1106,1108”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
In the citing paper
“Hyperinsulinemia, increased alcohol intake, starvation, and organ failure may be aggravating factors.1108,1200,1201”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
In the citing paper
“In persons with DM, iatrogenic hypoglycemia stems from an imbalance among insulin and/or insulinogenic (eg, SUs, glinides) therapy and food intake, physical activity, organ function (gluconeogenesis), and counter-regulation with glucagon and/or epinephrine (hypoglycemia-associated autonomic failure).”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
6 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., & Altman, D. G. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.06.005 · Cited by 19,575
Reduction in the incidence of type 2 diabetes with lifestyle intervention or metformin
(2002) · New England Journal of Medicine · doi:10.1056/nejmoa012512 · Cited by 19,011
Turner, R. C., Fox, C., Matthews, McElroy, H. H., Cull, C. A., Holman, R. R., Neil, P., Hadden, D. R., Wright, D., Manley, E., et al. (1998) · The Lancet · Cited by 8,419
Downs, S. H., & Black, N. (1998) · Journal of Epidemiology and Community Health · doi:10.1136/jech.52.6.377 · Cited by 8,252
10-year follow-up of intensive glucose control in type 2 diabetes
Holman, R. R., Paul, S. K., Bethel, M. A., Matthews, D. R., & Neil, H. A. W. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0806470 · Cited by 7,751
Cochrane Handbook for Systematic Reviews of Interventions Version 5.0.1. The Cochrane Collaboration
Higgins, J. P. T., Green, S. R., & Higgins, J. P. T. (2008) · Cited by 7,261
Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138
Norman, G. R., Sloan, J. A., & Wyrwich, K. W. (2003) · Medical Care · doi:10.1097/01.mlr.0000062554.74615.4c · Cited by 4,700
Standards of medical care in diabetes—2011
American Diabetes Association (2011) · Diabetes Care · doi:10.2337/dc11-s011 · Cited by 2,880
Standards of Medical Care in Diabetes—2012
(2012) · Diabetes Care · doi:10.2337/dc12-s011 · Cited by 2,240
Translating the A1C assay into estimated average glucose values
Nathan, D. M., Kuenen, J., Borg, R., Zheng, H., Schoenfeld, D., Heine, R. J., & for the A1c-Derived Average Glucose (ADAG) Study Group (2008) · Diabetes Care · doi:10.2337/dc08-0545 · Cited by 1,812
What to add to nothing? Use and avoidance of continuity corrections in meta‐analysis of sparse data
J. Sweeting, M., J. Sutton, A., & C. Lambert, P. (2004) · Statistics in Medicine · doi:10.1002/sim.1761 · Cited by 1,734
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Macronutrients, P. O., Fiber, P. O. T. D. O. D., Nutrients, S. O. U. R. L. O., Intakes, S. O. I. A. U. O. D. R., Standing Committee on the Scientific Evaluation of Dietary Reference Intakes, Food and Nutrition Board, & Institute of Medicine (2005) · doi:10.17226/10490 · Cited by 1,482
Defining and Reporting Hypoglycemia in Diabetes
American Diabetes Association Workgroup on Hypoglycemia (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1245 · Cited by 1,146
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894
In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760
Pickup, J. C., & Sutton, A. J. (2008) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02486.x · Cited by 617
Pickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
Deiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
Owens, D. K., Lohr, K. N., Atkins, D., Treadwell, J. R., Reston, J. T., Bass, E. B., Chang, S., & Helfand, M. (2010) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.03.009 · Cited by 513
Self-citationOutpatient Insulin Therapy in Type 1 and Type 2 Diabetes Mellitus: Scientific Review
DeWitt, D. E., & Hirsch, I. B. (2003) · JAMA · doi:10.1001/jama.289.17.2254 · Cited by 502
Effect of Continuous Glucose Monitoring on Hypoglycemia in Type 1 Diabetes
Battelino, T., Phillip, M., Bratina, N., Nimri, R., Oskarsson, P., & Bolinder, J. (2011) · Diabetes Care · doi:10.2337/dc10-1989 · Cited by 490 · cited 27×
“No difference Low‡ General QOL No difference Low§ Favors CSII Low‡§ Cannot conclude Insufficient No difference Low ** Cannot conclude Insufficient Diabetes mellitus– specific QOL Favors CSII Low§ Favors CSII Low‡§ Cannot conclude Insufficient No difference Low¶ – – Diabetes mellitus treatment– related QOL Favors CSII…”
BackgroundInfluentialMisso, M. L., Egberts, K. J., Page, M., O'Connor, D., & Shaw, J. (2010) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005103.pub2 · Cited by 406
The effect of continuous glucose monitoring in well-controlled type 1 diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0108 · Cited by 399
Jeitler, K., Horvath, K., Berghold, A., Gratzer, T. W., Neeser, K., Pieber, T. R., & Siebenhofer, A. (2008) · Diabetologia · doi:10.1007/s00125-008-0974-3 · Cited by 375
Doyle (Boland), E. A., Weinzimer, S. A., Steffen, A. T., Ahern, J. A. H., Vincent, M., & Tamborlane, W. V. (2004) · Diabetes Care · doi:10.2337/diacare.27.7.1554 · Cited by 373 · cited 28×
“No difference Low‡ General QOL No difference Low§ Favors CSII Low‡§ Cannot conclude Insufficient No difference Low ** Cannot conclude Insufficient Diabetes mellitus– specific QOL Favors CSII Low§ Favors CSII Low‡§ Cannot conclude Insufficient No difference Low¶ – – Diabetes mellitus treatment– related QOL Favors CSII…”
BackgroundInfluentialCummins, E., Royle, P., Snaith, A., Greene, A., Robertson, L., McIntyre, L., & Waugh, N. (2010) · Health Technology Assessment · doi:10.3310/hta14110 · Cited by 335
Sensor-Augmented Insulin Pump Therapy: Results of the First Randomized Treat-to-Target Study
Hirsch, I. B., Abelseth, J., Bode, B. W., Fischer, J. S., Kaufman, F. R., Mastrototaro, J., Parkin, C. G., Wolpert, H. A., & Buckingham, B. A. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0068 · Cited by 297 · cited 10×
“Continued on following page W-94 4 September 2012 Annals of Internal Medicine Volume 157 • Number 5 www.annals.org Downloaded From: http://annals.org/pdfaccess.ashx?url=/data/journals/aim/24808/ on 07/07/2017 Appendix Table 5—Continued Outcome Risk of Bias Strength of Evidence Studies/Studies of Good Quality, N/n Main…”
BackgroundInfluentialHerman, W. H., Ilag, L. L., Johnson, S. L., Martin, C. L., Sinding, J., Al Harthi, A., Plunkett, C. D., LaPorte, F. B., Burke, R., Brown, M. B., et al. (2005) · Diabetes Care · doi:10.2337/diacare.28.7.1568 · Cited by 265 · cited 4×
“…Unclear No Unclear Unable to determine Unable to determine Poor Herman et al, 2005 (48) Unclear Yes Unclear Unclear Yes Unable to determine Fair Herman et al, 2005 (48) Yes No No No Yes Unable to determine Fair Raskin et al, 2003 (49) Yes Unclear Unclear No Yes Unable to determine Poor Raskin…”
BackgroundInfluentialHoogma, R. P. L. M., Hammond, P. J., Gomis, R., Kerr, D., Bruttomesso, D., Bouter, K. P., Wiefels, K. J., De La Calle, H., Schweitzer, D. H., Pfohl, M., et al. (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01738.x · Cited by 255 · cited 3×
“Study Quality and Risk of Bias Assessment of Clinical Trials Comparing Methods of Insulin Delivery or Glucose Monitoring for Diabetes Mellitus* Study, Year (Reference) Sequence Generation Allocation Concealment Blinding, Personnel, Outcome Incomplete Outcome Data Device Company Support Device Company Involvement Overa…”
BackgroundRücker, G., Schwarzer, G., Carpenter, J., & Olkin, I. (2009) · Statistics in Medicine · doi:10.1002/sim.3511 · Cited by 252
Raskin, P., Bode, B. W., Marks, J. B., Hirsch, I. B., Weinstein, R. L., McGill, J. B., Peterson, G. E., Mudaliar, S. R., & Reinhardt, R. R. (2003) · Diabetes Care · doi:10.2337/diacare.26.9.2598 · Cited by 249 · cited 4×
“…Herman et al, 2005 (48) Unclear Yes Unclear Unclear Yes Unable to determine Fair Herman et al, 2005 (48) Yes No No No Yes Unable to determine Fair Raskin et al, 2003 (49) Yes Unclear Unclear No Yes Unable to determine Poor Raskin et al, 2003 (49) Yes Yes No Yes Yes Unable to determine Fair…”
BackgroundInfluentialRaccah, D., Sulmont, V., Reznik, Y., Guerci, B., Renard, E., Hanaire, H., Jeandidier, N., & Nicolino, M. (2009) · Diabetes Care · doi:10.2337/dc09-0750 · Cited by 237 · cited 6×
“Favors rt-CGM Mean Between-Group Difference in Time Spent in Hyperglycemic Range, min/d Favors SMBG –200 –150 –100 –50 0 50 Study, Year (Reference) Raccah et al, 2009 (53) Tamborlane et al, 2008 (56)* Tamborlane et al, 2008 (56)† Battelino et al, 2011 (59) Tamborlane et al, 2008 (56)‡ O’Connell et…”
BackgroundInfluentialWeintrob, N., Benzaquen, H., Galatzer, A., Shalitin, S., Lazar, L., Fayman, G., Lilos, P., Dickerman, Z., & Phillip, M. (2003) · Pediatrics · doi:10.1542/peds.112.3.559 · Cited by 236 · cited 5×
“…al, 2004 (32) Schiaffini et al, 2007 (35) Cohen et al, 2003 (31) Nuboer et al, 2008 (33) Opipari-Arrigan et al, 2007 (34) Skogsberg et al, 2008 (36) Weintrob et al, 2003 (37) Subtotal (I2 = 0.0%; P = 0.561) Adults with T1DM DeVries et al, 2002 (40) Thomas et al, 2007 (44) Bolli et al, 2009…”
BackgroundInfluentialComing of age: the artificial pancreas for type 1 diabetes
Thabit, H., & Hovorka, R. (2016) · Diabetologia · doi:10.1007/s00125-016-4022-4 · Cited by 223
Fatourechi, M. M., Kudva, Y. C., Murad, M. H., Elamin, M. B., Tabini, C. C., & Montori, V. M. (2009) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2008-1415 · Cited by 221
Continuous glucose monitoring: an Endocrine Society Clinical Practice Guideline
Klonoff, D. C., Buckingham, B., Christiansen, J. S., Montori, V. M., Tamborlane, W. V., Vigersky, R. A., & Wolpert, H. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2756 · Cited by 211
O’Connell, M. A., Donath, S., O’Neal, D. N., Colman, P. G., Ambler, G. R., Jones, T. W., Davis, E. A., & Cameron, F. J. (2009) · Diabetologia · doi:10.1007/s00125-009-1365-0 · Cited by 211 · cited 12×
“Continued on following page W-94 4 September 2012 Annals of Internal Medicine Volume 157 • Number 5 www.annals.org Downloaded From: http://annals.org/pdfaccess.ashx?url=/data/journals/aim/24808/ on 07/07/2017 Appendix Table 5—Continued Outcome Risk of Bias Strength of Evidence Studies/Studies of Good Quality, N/n Main…”
BackgroundInfluentialPańkowska, E., Błazik, M., Dziechciarz, P., Szypowska, A., & Szajewska, H. (2009) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2008.00440.x · Cited by 209
Mauras, N., Beck, R., Xing, D., Ruedy, K., Buckingham, B., Tansey, M., White, N. H., Weinzimer, S. A., Tamborlane, W., Kollman, C., et al. (2012) · Diabetes Care · doi:10.2337/dc11-1746 · Cited by 204 · cited 10×
“Continued on following page W-94 4 September 2012 Annals of Internal Medicine Volume 157 • Number 5 www.annals.org Downloaded From: http://annals.org/pdfaccess.ashx?url=/data/journals/aim/24808/ on 07/07/2017 Appendix Table 5—Continued Outcome Risk of Bias Strength of Evidence Studies/Studies of Good Quality, N/n Main…”
BackgroundInfluentialHirsch, I. B., Bode, B. W., Garg, S., Lane, W. S., Sussman, A., Hu, P., Santiago, O. M., Kolaczynski, J. W., & for the Insulin Aspart CSII/MDI Comparison Study Group (2005) · Diabetes Care · doi:10.2337/diacare.28.3.533 · Cited by 197 · cited 8×
“Continued on following page W-94 4 September 2012 Annals of Internal Medicine Volume 157 • Number 5 www.annals.org Downloaded From: http://annals.org/pdfaccess.ashx?url=/data/journals/aim/24808/ on 07/07/2017 Appendix Table 5—Continued Outcome Risk of Bias Strength of Evidence Studies/Studies of Good Quality, N/n Main…”
BackgroundInfluentialDeVries, J. H., Snoek, F. J., Kostense, P. J., Masurel, N., Heine, R. J., & On behalf of the Dutch Insulin Pump Study Group (2002) · Diabetes Care · doi:10.2337/diacare.25.11.2074 · Cited by 187
Hanaire-Broutin, H., Melki, V, Bessières-Lacombe, S., & Tauber, J. P. (2000) · Diabetes Care · doi:10.2337/diacare.23.9.1232 · Cited by 174 · cited 3×
“Study Quality and Risk of Bias Assessment of Clinical Trials Comparing Methods of Insulin Delivery or Glucose Monitoring for Diabetes Mellitus* Study, Year (Reference) Sequence Generation Allocation Concealment Blinding, Personnel, Outcome Incomplete Outcome Data Device Company Support Device Company Involvement Overa…”
BackgroundHermanides, J., Nørgaard, K., Bruttomesso, D., Mathieu, C., Frid, A., Dayan, C. M., Diem, P., Fermon, C., Wentholt, I. M. E., Hoekstra, J. B. L., et al. (2011) · Diabetic Medicine · doi:10.1111/j.1464-5491.2011.03256.x · Cited by 169 · cited 3×
“…et al, 2008 (56)† Hirsch et al, 2008 (57) Mauras et al, 2012 (60) Tamborlane et al, 2008 (56)‡ Subtotal (I2 = 69.9%; P = 0.000) SAP vs. MDI plus SMBG Hermanides et al, 2011 (66) Lee et al, 2007 (65) Peyrot and Rubin, 2009 (64) Bergenstal et al, 2010 (63) Subtotal (I2 = 53.7%; P = 0.091) SMBG,…”
BackgroundInfluentialTamborlane, W. V., Bode, B. W., Buckingham, B. A., Chase, H. P., Clemons, R. D., Fox, L. A., Gilliam, L. K., Hirsch, I. B., Huang, E. S., Kollman, C., et al. (2008) · Cited by 167
Insulin pump therapy vs. multiple daily injections in obese Type 2 diabetic patients
Wainstein, J., Metzger, M., Boaz, M., Minuchin, O., Cohen, Y., Yaffe, A., Yerushalmy, Y., Raz, I., & Harman‐Boehm, I. (2005) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01597.x · Cited by 136 · cited 4×
“…(49) Yes Yes No Yes Yes Unable to determine Fair Wainstein et al, 2005 (50) Unclear Unclear Unclear No Unable to determine Unable to determine Fair Wainstein et al, 2005 (50) Unclear No No Yes Unable to determine Unable to determine Fair rt-CGM vs. SMBG in children and adults with T1DM Battelino…”
BackgroundInfluentialBruttomesso, D., Crazzolara, D., Maran, A., Costa, S., Dal Pos, M., Girelli, A., Lepore, G., Aragona, M., Iori, E., Valentini, U., et al. (2008) · Diabetic Medicine · doi:10.1111/j.1464-5491.2007.02365.x · Cited by 136 · cited 3×
“Study Quality and Risk of Bias Assessment of Clinical Trials Comparing Methods of Insulin Delivery or Glucose Monitoring for Diabetes Mellitus* Study, Year (Reference) Sequence Generation Allocation Concealment Blinding, Personnel, Outcome Incomplete Outcome Data Device Company Support Device Company Involvement Overa…”
BackgroundKordonouri, O., Pańkowska, E., Rami-Merhar, B. M., Kapellen, T. M., Coutant, R., Hartmann, R., Lange, K., Knip, M., & Danne, T. (2010) · Diabetologia · doi:10.1007/s00125-010-1878-6 · Cited by 133 · cited 9×
“Continued on following page W-94 4 September 2012 Annals of Internal Medicine Volume 157 • Number 5 www.annals.org Downloaded From: http://annals.org/pdfaccess.ashx?url=/data/journals/aim/24808/ on 07/07/2017 Appendix Table 5—Continued Outcome Risk of Bias Strength of Evidence Studies/Studies of Good Quality, N/n Main…”
BackgroundInfluentialIntensive Insulin Therapy With Insulin Lispro
Tsui, E., Barnie, A., Ross, S., Parkes, R., & Zinman, B. (2001) · Diabetes Care · doi:10.2337/diacare.24.10.1722 · Cited by 131 · cited 10×
“…Unclear Yes No Fair Thomas et al, 2007 (44) Unclear Unclear No Yes Yes No Fair Tsui et al, 2001 (45) Yes Yes Unclear Yes Yes Unable to determine Good Tsui et al, 2001 (45) Yes Yes No Unclear Yes Unable to determine Fair CSII vs. MDI in adults with T2DM Derosa et al, 2009 (47) Unclear Unclear…”
BackgroundInfluentialMonami, M., Lamanna, C., Marchionni, N., & Mannucci, E. (2009) · Acta Diabetologica · doi:10.1007/s00592-009-0132-5 · Cited by 123
Use of continuous glucose monitoring in children and adolescents *
Phillip, M., Danne, T., Shalitin, S., Buckingham, B. A., Laffel, L. M., Tamborlane, W. V., Battelino, T., & Participants, F. T. C. F. (2012) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2011.00849.x · Cited by 122
Bolli, G. B., Kerr, D., Thomas, R., Torlone, E., Sola-Gazagnes, A., Vitacolonna, E., Selam, J. L., & Home, P. D. (2009) · Diabetes Care · doi:10.2337/dc08-1874 · Cited by 119 · cited 26×
“No difference Low‡ General QOL No difference Low§ Favors CSII Low‡§ Cannot conclude Insufficient No difference Low ** Cannot conclude Insufficient Diabetes mellitus– specific QOL Favors CSII Low§ Favors CSII Low‡§ Cannot conclude Insufficient No difference Low¶ – – Diabetes mellitus treatment– related QOL Favors CSII…”
BackgroundInfluentialQuality-of-Life Measures in Children and Adults With Type 1 Diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc10-0331 · Cited by 101
Skogsberg, L., Fors, H., Hanas, R., Chaplin, J., Lindman, E., & Skogsberg, J. (2008) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2008.00390.x · Cited by 90 · cited 6×
“1 events] [36]; mean between-group difference in the change from baseline to 24 wk in the number of blood glucose measurements 3.”
BackgroundInfluentialRubin, R. R., & Peyrot, M. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0162 · Cited by 82
Nuboer, R., Borsboom, G. J., Zoethout, J. A., Koot, H. M., & Bruining, J. (2008) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2008.00396.x · Cited by 79 · cited 9×
“Continued on following page W-94 4 September 2012 Annals of Internal Medicine Volume 157 • Number 5 www.annals.org Downloaded From: http://annals.org/pdfaccess.ashx?url=/data/journals/aim/24808/ on 07/07/2017 Appendix Table 5—Continued Outcome Risk of Bias Strength of Evidence Studies/Studies of Good Quality, N/n Main…”
BackgroundInfluentialPeyrot, M., & Rubin, R. R. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0002 · Cited by 68 · cited 3×
“…2007 (65) Unclear Unclear Unclear Unclear Unable to determine Unable to determine Fair Peyrot and Rubin, 2009 (64) Unclear Unclear Unclear Yes Yes No Poor Peyrot and Rubin, 2009 (64) Unclear No Unclear Yes Yes No Poor CSII continuous subcutaneous insulin infusion; MDI multiple daily injections;…”
BackgroundInfluentialOpipari-Arrigan, L., Fredericks, E. M., Burkhart, N., Dale, L., Hodge, M., & Foster, C. (2007) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2007.00283.x · Cited by 64
Lepore, G., Dodesini, A. R., Nosari, I., & Trevisan, R. (2003) · Diabetes Care · doi:10.2337/diacare.26.4.1321 · Cited by 55
Cohen, D., Weintrob, N., Benzaquen, H., Galatzer, A., Fayman, G., & Phillip, M. (2003) · Journal of Pediatric Endocrinology and Metabolism · doi:10.1515/jpem.2003.16.7.1047 · Cited by 54 · cited 25×
“No difference Low‡ General QOL No difference Low§ Favors CSII Low‡§ Cannot conclude Insufficient No difference Low ** Cannot conclude Insufficient Diabetes mellitus– specific QOL Favors CSII Low§ Favors CSII Low‡§ Cannot conclude Insufficient No difference Low¶ – – Diabetes mellitus treatment– related QOL Favors CSII…”
BackgroundInfluentialMonami, M., Lamanna, C., Marchionni, N., & Mannucci, E. (2009) · Experimental and Clinical Endocrinology & Diabetes · doi:10.1055/s-0028-1119405 · Cited by 48
Insulin pump therapy in adults
Didangelos, T., & Iliadis, F. S. (2011) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(11)70025-0 · Cited by 45
Thomas, R. M., Aldibbiat, A., Griffin, W., Cox, M. A. A., Leech, N. J., & Shaw, J. A. M. (2007) · Diabetic Medicine · doi:10.1111/j.1464-5491.2007.02196.x · Cited by 40 · cited 5×
“…et al, 2007 (34) Skogsberg et al, 2008 (36) Weintrob et al, 2003 (37) Subtotal (I2 = 0.0%; P = 0.561) Adults with T1DM DeVries et al, 2002 (40) Thomas et al, 2007 (44) Bolli et al, 2009 (39) Tsui et al, 2001 (45) Subtotal (I2 = 64.5%; P = 0.038) Subtotal, excluding DeVries et al (I2 = 0.0%; P…”
BackgroundInfluentialSchiaffini, R., Patera, P. I., Bizzarri, C., Ciampalini, P., & Cappa, M. (2007) · Journal of Endocrinological Investigation · doi:10.1007/bf03346351 · Cited by 28 · cited 5×
“…Unclear Unclear Unable to determine Unable to determine Poor Schiaffini et al, 2007 (35) Unclear Unclear Unclear Unclear No Unable to determine Poor Schiaffini et al, 2007 (35) Unclear Unclear No Unclear No Unable to determine Poor Skogsberg et al, 2008 (36) Unclear Unclear Unclear Unclear Unable…”
BackgroundInfluentialContinuous Glucose Monitoring — Coming of Age
Wolpert, H. A. (2010) · New England Journal of Medicine · doi:10.1056/nejme1006098 · Cited by 26
Radermecker, R. P., Remy, A. S., Scheen, A. J., Bringer, J., & Renard, É. (2010) · Diabetes & Metabolism · doi:10.1016/j.diabet.2010.08.001 · Cited by 22 · cited 2×
“…Raccah et al, 2009 (53) Unclear Unclear No No Yes Unable to determine Fair Raccah et al, 2009 (53) Unclear Unclear No No Yes Unable to determine Fair Radermecker et al, 2010 (51) Unclear Unclear No Yes No No Fair Radermecker et al, 2010 (51) Unclear Unclear No No No Unable to determine Fair…”
BackgroundLee, S. W., Sweeney, T., Clausen, D., Kolbach, C., Hassen, A., Firek, A. F., Brinegar, C. H., & PETROFSKY, J. S. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100313 · Cited by 21 · cited 3×
“…Yes Fair Hermanides et al, 2011 (66) Yes Yes No Yes Unable to determine Unable to determine Good Hermanides et al, 2011 (66) Yes Yes No Yes Yes Yes Good Lee et al, 2007 (65) Unclear Unclear No No Unable to determine Unable to determine Fair Lee et al, 2007 (65) Unclear Unclear Unclear Unclear…”
BackgroundInfluentialDerosa, G., Maffioli, P., D’Angelo, A., SALVADEO, S. A. T., Ferrari, I., Fogari, E., Mereu, R., Gravina, A., Palumbo, I., Randazzo, S., et al. (2009) · Endocrine Journal · doi:10.1507/endocrj.k08e-330 · Cited by 15 · cited 11×
“No difference Low‡ General QOL No difference Low§ Favors CSII Low‡§ Cannot conclude Insufficient No difference Low ** Cannot conclude Insufficient Diabetes mellitus– specific QOL Favors CSII Low§ Favors CSII Low‡§ Cannot conclude Insufficient No difference Low¶ – – Diabetes mellitus treatment– related QOL Favors CSII…”
BackgroundInfluential
Research works printed but not linked: 2
- 20587584N Engl J Med. 363N Engl J Med. 2010;363:383-4. [PMID: 20587584]
- Diabetes Prevention Program Research Group. Reduction in domized treat-to-target study. W C Knowler, E Barrett-Connor, S E Fowler, R F Hamman, J M Lachin, E A Walker, 18715214Diabetes Technol Ther. 10Knowler WC, Barrett-Connor E, Fowler SE, Hamman RF, Lachin JM, Walker EA, et al; Diabetes Prevention Program Research Group. Reduction in domized treat-to-target study. Diabetes Technol Ther. 2008;10:377-83. [PMID: 18715214]
Cited by
Standards of medical care in diabetes—2014
American Diabetes Association (2014) · Diabetes Care · doi:10.2337/dc14-s014 · Cited by 4,572
Standards of medical care in diabetes—2013
American Diabetes Association (2013) · Diabetes Care · doi:10.2337/dc13-s011 · Cited by 4,369
“The technologymay be particularly useful in thosewith hypoglycemia unawareness and/or frequent episodes of hypoglycemia, although studies as yet have not shown significant reductions in severe hypoglycemia (70).”
BackgroundResultAtkinson, M. A., Eisenbarth, G. S., & Michels, A. W. (2014) · The Lancet · doi:10.1016/s0140-6736(13)60591-7 · Cited by 2,931
9. Pharmacologic Approaches to Glycemic Treatment: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s009 · Cited by 1,555
9. Pharmacologic Approaches to Glycemic Treatment: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s009 · Cited by 972
Metadata
- Authors
- Yeh, H.-C., Brown, T. T., Maruthur, N., Ranasinghe, P., Berger, Z., Suh, Y. D., Wilson, L. M., Haberl, E. B., Brick, J., Bass, E. B., & Golden, S. H.
- Affiliations
- Johns Hopkins University (US)
- Harvard University (US)
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2012-09-04
- Volume
- 157
- Issue
- 5
- Pages
- 336-347
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2035018400
- Semantic Scholar
- 6a9836e0bc9a84e7b30be275ad35b904df13faab
- Cited by
- 493
- References
- 72
- Citations by year
- 2026: 14 · 2025: 15 · 2024: 27 · 2023: 19 · 2022: 31 · 2021: 38 · 2020: 45 · 2019: 44 · 2018: 48 · 2017: 36 · 2016: 48 · 2015: 46 · 2014: 48 · 2013: 32 · 2012: 2
- FWCI
- 5.63
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by-nc-nd
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Repositorio UTB (submittedVersion, cc-by-nc-nd)
- Funders
- National Institute of Diabetes and Digestive and Kidney Diseases (P30DK079637)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- diabetes mellitus, insulin delivery, insulin pump therapy, multiple daily insulin injections, sensor-augmented pump, continuous glucose monitoring, self-monitoring of blood glucose, glycemic control, HbA1c, hypoglycemia, type 1 diabetes, type 2 diabetes, intensive insulin therapy, rapid-acting insulin analogs, children and adults, comparative effectiveness
- MeSH terms
- Blood Glucose, Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2, Glycated Hemoglobin, Humans, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Monitoring, Physiologic, Blood Glucose Self-Monitoring, Treatment Outcome, Comparative Effectiveness Research
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.