Abstract
BACKGROUND: Patients with diabetes mellitus need information about the effectiveness of innovations in insulin delivery and glucose monitoring. PURPOSE: To review how intensive insulin therapy (multiple daily injections [MDI] vs. rapid-acting analogue-based continuous subcutaneous insulin infusion [CSII]) or method of monitoring (self-monitoring of blood glucose [SMBG] vs. real-time continuous glucose monitoring [rt-CGM]) affects outcomes in types 1 and 2 diabetes mellitus. DATA SOURCES: MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials through February 2012 without language restrictions. STUDY SELECTION: 33 randomized, controlled trials in children or adults that compared CSII with MDI (n=19), rt-CGM with SMBG (n=10), or sensor-augmented insulin pump use with MDI and SMBG (n=4). DATA EXTRACTION: 2 reviewers independently evaluated studies for eligibility and quality and serially abstracted data. DATA SYNTHESIS: In randomized, controlled trials, MDI and CSII showed similar effects on hemoglobin A1c (HbA1c) levels and severe hypoglycemia in children or adults with type 1 diabetes mellitus and adults with type 2 diabetes mellitus. In adults with type 1 diabetes mellitus, HbA1c levels decreased more with CSII than with MDI, but 1 study heavily influenced these results. Compared with SMBG, rt-CGM achieved a lower HbA1c level (between-group difference of change, 0.26% [95% CI, 0.33% to 0.19%]) without any difference in severe hypoglycemia. Sensor-augmented insulin pump use decreased HbA1c levels more than MDI and SMBG did in persons with type 1 diabetes mellitus (between-group difference of change, 0.68% [CI, 0.81% to 0.54%]). Little evidence was available on other outcomes. LIMITATION: Many studies were small, of short duration, and limited to white persons with type 1 diabetes mellitus. CONCLUSION: Continuous subcutaneous insulin infusion and MDI have similar effects on glycemic control and hypoglycemia, except CSII has a favorable effect on glycemic control in adults with type 1 diabetes mellitus. For glycemic control, rt-CGM is superior to SMBG and sensor-augmented insulin pumps are superior to MDI and SMBG without increasing the risk for hypoglycemia. PRIMARY FUNDING SOURCE: Agency for Healthcare Research and Quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Rates and the clinical impact of hypoglycemia are frequently underestimated,1108”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
In the citing paper
“The frequency of hypoglycemia increases with intensive insulin targets, use of SUs, decreased caloric intake, delayed meals, exercise, alcohol consumption, CKD, T2D duration, and cognitive impairment.1108”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
In the citing paper
“but about 7% to 15% of insulin-treated persons with T2D experience at least 1 episode of hypoglycemia per year,1109 and 1% to 2% have severe hypoglycemia.1106,1108”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
In the citing paper
“Hyperinsulinemia, increased alcohol intake, starvation, and organ failure may be aggravating factors.1108,1200,1201”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
In the citing paper
“In persons with DM, iatrogenic hypoglycemia stems from an imbalance among insulin and/or insulinogenic (eg, SUs, glinides) therapy and food intake, physical activity, organ function (gluconeogenesis), and counter-regulation with glucagon and/or epinephrine (hypoglycemia-associated autonomic failure).”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
6 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., & Altman, D. G. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.06.005 · Cited by 19,575
Reduction in the incidence of type 2 diabetes with lifestyle intervention or metformin
(2002) · New England Journal of Medicine · doi:10.1056/nejmoa012512 · Cited by 19,011
Turner, R. C., Fox, C., Matthews, McElroy, H. H., Cull, C. A., Holman, R. R., Neil, P., Hadden, D. R., Wright, D., Manley, E., et al. (1998) · The Lancet · Cited by 8,419
Downs, S. H., & Black, N. (1998) · Journal of Epidemiology and Community Health · doi:10.1136/jech.52.6.377 · Cited by 8,252
Research works printed but not linked: 1
- Misso ML, 2010, Cochrane Database Syst Rev, CD005103
Cited by
Items 301–400 of 492
Blackberry, I., Furler, J., Ginnivan, L., Derraz, H., Jenkins, A. J., Cohen, N. D., Best, J. D., Young, D. Y. L., Liew, D., Ward, G. M., et al. (2014) · BMC Family Practice · doi:10.1186/1471-2296-15-82 · Cited by 10
Lepore, G., Bonfanti, R., Bozzetto, L., Blasi, V. D., Girelli, A., Grassi, G., Iafusco, D., Laviola, L., Rabbone, I., Schiaffini, R., et al. (2017) · Nutrition Metabolism and Cardiovascular Diseases · doi:10.1016/j.numecd.2017.12.001 · Cited by 12
Petrovski, G., Khalaf, F. A., Hussain, K., Campbell, J., & Awwa, A. E. (2018) · Diabetes Therapy · doi:10.1007/s13300-018-0510-5 · Cited by 9
“through intensive insulin therapy, to reduce the frequency of hypoglycemia, to prevent serious long-term complications, and to improve the quality of life [3, 4].”
BackgroundChristou, M., Christou, P. A., Katsarou, D. N., Georga, E. I., Kyriakopoulos, C., Markozannes, G., Christou, G. A., Fotiadis, D. I., & Tigas, S. K. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13175303 · Cited by 9
“However, some other studies found no such difference in weight gain between CSII and MDI-treated patients [36–40].”
ResultNimri, R., Murray, N., Ochs, A., Pinsker, J. E., & Dassau, E. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.2504 · Cited by 8
Achievement of metabolic control among children and adolescents with type 1 diabetes in Spain
Rica, I., Delgado, A. M., Gómez-Gila, A. L., Clemente, M., González, I. P., Caimari, M., Cuartero, B. G., & Barrio, R. (2017) · Acta Diabetologica · doi:10.1007/s00592-017-0991-0 · Cited by 9
“Most children and adolescents diagnosed with diabetes presented with only one isolated episode of severe hypoglycaemia; however, a minor group of patients suffered from repeated severe hypoglycaemias [40].”
BackgroundComparative effectiveness and costs of insulin pump therapy for diabetes.
Ackermann, R. T., Wallia, A., Kang, R. H., Cooper, A., Prospect, T. A., Sandy, L. G., & Vojta, D. D. (2017) · The American Journal of Managed Care · Cited by 12
Couples Managing Type 1 Diabetes Using Diabetes Technology
Allen, N. A., Litchman, M. L., Neller, S. A., Tracy, E. L., de Grey, R. G. K., Grigorian, E. G., Helgeson, V. S., & Berg, C. A. (2021) · Diabetes Spectrum · doi:10.2337/ds20-0045 · Cited by 9
Petrovski, G., Živković, M., Stratrova, S. S., & Todorova, B. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0227 · Cited by 7
O’Connell, M. A., NORTHAM, E. A., Brown, A. M., Papoutsis, J., Schuster, T., Skinner, T. C., Jenkins, A. J., Ambler, G. R., & Cameron, F. J. (2024) · Archives of Disease in Childhood · doi:10.1136/archdischild-2023-326007 · Cited by 8
What Is New in Diabetes Technology?
Marvicsin, D. J., Jennings, P., & Ziegler-Bezaire, D. (2017) · The Journal for Nurse Practitioners · doi:10.1016/j.nurpra.2016.12.025 · Cited by 6
Coronel-Restrepo, N., Blanco, V. M., Palacio, A., Rincón, A. R., Arbeláez, S., Duque, V., Pino, J. J., Carvajal, J. A., Bedoya, J., Cuesta, D., et al. (2020) · Endocrinología Diabetes y Nutrición · doi:10.1016/j.endinu.2020.07.012 · Cited by 6
Encapsulation Strategies for Pancreatic Islet Transplantation without Immune Suppression
Sittadjody, S., & Opara, E. C. (2021) · Current Stem Cell Reports · doi:10.1007/s40778-021-00190-w · Cited by 7
Almazrouei, R. A., Sharma, C., Afandi, B. O., Aldahmani, K. M., Aburawi, E. H., Beshyah, S., ElGhazali, G. E., Yafei, Z. A., Al‐Rifai, R. H., & Alkaabi, J. (2022) · PLoS ONE · doi:10.1371/journal.pone.0264545 · Cited by 7
“25%) [7], or there is no statistically significant difference in the frequency of severe hypoglycemia between the two treatments in either adults or children with T1D [29].”
BackgroundKurdi, S. M., Alamer, A., Wali, H., Badr, A. F., Pendergrass, M., Ahmed, N. J., Abraham, I. L., & Fazel, M. T. (2023) · Endocrine Practice · doi:10.1016/j.eprac.2023.03.002 · Cited by 11
Ribeiro, M. E. B., Liberatore, R. D. R., Custódio, R. J., & Martinelli, C. E. (2016) · Revista Paulista de Pediatria · doi:10.1016/j.rpped.2015.06.011 · Cited by 8
Practical Implementation of Diabetes Technology: Real‐World Use
Messer, L. H., & WEINZIMER, S. A. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.2509 · Cited by 7
An up-to-date evaluation of sotagliflozin for the treatment of type 1 diabetes
Chatzopoulos, G., & Τζιόμαλος, Κ. (2020) · Expert Opinion on Pharmacotherapy · doi:10.1080/14656566.2020.1793961 · Cited by 7
Ribeiro, M. E. B., Liberatore, R. D. R., Custódio, R. J., & Martinelli, C. E. (2015) · Revista Paulista de Pediatria (English Edition) · doi:10.1016/j.rppede.2015.06.019 · Cited by 6
NUEVAS TECNOLOGÿAS EN DIABETES
Apablaza, P., Néstor Soto, I., Román, R., & Ethel Codner, D. (2016) · Revista Médica Clínica Las Condes · doi:10.1016/j.rmclc.2016.04.011 · Cited by 13
Yoshimura, K., Hirota, Y., Saito, S., Nishikage, S., Yamamoto, A., Takayoshi, T., Urai, S., & Ogawa, W. (2024) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgae863 · Cited by 6
Sathishkumar, M., Dhorajiwala, M. M., Kumar, M. S., Gaba, S., Vignesh, M., & Anbuchezhiyan, G. (2025) · Materials Today Communications · doi:10.1016/j.mtcomm.2025.114490 · Cited by 12
Insulin delivery and nocturnal glucose control in children and adolescents with type 1 diabetes
Tauschmann, M., & Hovorka, R. (2017) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2017.1360866 · Cited by 6
“Clinical benefits of continuous glucose monitoring including combined use of insulin pump are conditioned on high regular use [16,17].”
BackgroundAgarwal, S., Khokhar, A., Castells, S., Marwa, A., Hagerty, D., Dunkley, L., Cooper, J., Chin, V. L., Umpaichitra, V., & Perez-Colon, S. (2018) · Journal of the National Medical Association · doi:10.1016/j.jnma.2018.05.002 · Cited by 7
Martyn-Nemeth, P. A., Duffecy, J. L., Quinn, L., Reutrakul, S., Steffen, A. D., Burke, L., Withington, M. H. C., Irsheed, G. A., Perez, R., Park, M., et al. (2022) · Trials · doi:10.1186/s13063-022-06565-6 · Cited by 8
Hypoglycemia in Type 1 Diabetes Mellitus
Şakar, K., & Çınar, N. (2024) · IntechOpen eBooks · doi:10.5772/intechopen.1004108 · Cited by 9
Suboptimally Controlled Diabetes in Pregnancy: A Review to Guide Antepartum and Delivery Management
Cate, J. J. M., Bloom, E. A., Chu, A., Bauer, S., Kuller, J. A., & Dotters-Katz, S. K. (2024) · Obstetrical & Gynecological Survey · doi:10.1097/ogx.0000000000001270 · Cited by 7
Continuous Glucose Monitoring in 2012
Bode, B. W., & Battelino, T. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.1502 · Cited by 6
Supporting patients with type 1 diabetes
Phillips, A. (2016) · British Journal of Nursing · doi:10.12968/bjon.2016.25.6.330 · Cited by 10
Cavalcante, R. B. D. M., Matheus, A. S. D. M., Zanette, A., Braga, B., Duarte, B. P., Würdig, B., Maieron, D., Sorio, J. S., Bagatini, L., Cherit, M., et al. (2019) · Diabetology & Metabolic Syndrome · doi:10.1186/s13098-019-0443-9 · Cited by 6
Glucose monitoring in diabetes: A suggested algorithm to choice the best treatment option
Longo, M., Petrizzo, M., Esposito, K., & Maiorino, M. I. (2020) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2020.108242 · Cited by 6
Morrison, A., Senior, P. A., Bubela, T. M., Farnsworth, K., Witteman, H. O., & Lam, A. P. (2022) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2022.06.003 · Cited by 8
CYRANKA, K. M., Juza, A., Kwiendacz, H., Nabrdalik, K., Gumprecht, J., Malecki, M. T., Klupa, T., & Matejko, B. (2023) · JMIR Formative Research · doi:10.2196/46513 · Cited by 26
Diabetestechnologie (Update 2023)
Schütz-Fuhrmann, I., Rami-Merhar, B. M., Fröhlich-Reiterer, E. E., Hofer, S. E., Tauschmann, M., Mader, J. K., Resl, M., Kautzky‐Willer, A., Winhofer-Stöckl, Y., Laimer, M., et al. (2023) · Wiener klinische Wochenschrift · doi:10.1007/s00508-023-02165-9 · Cited by 5
Thrasher, J. R., Bhargava, A., Rees, T. M., Wang, T., Guzmán, C. B., & Glass, L. C. (2014) · Endocrine Practice · doi:10.4158/ep14242.or · Cited by 5
Psychopathology and Continuous Subcutaneous Insulin Infusion in Type 1 Diabetes
Rotella, F., Lamanna, C., Dicembrini, I., Faravelli, C., Calasso, C., & Mannucci, E. (2013) · The Scientific World JOURNAL · doi:10.1155/2013/672729 · Cited by 6
Insulin pump therapy: education and its goals
Štechová, K. (2019) · Vnitřní lékařství · doi:10.36290/vnl.2019.042 · Cited by 9
Predictive Low Glucose Suspend Algorithm in Real Life: A Five-Year Follow-Up Retrospective Analysis
Tubili, C., Pollakova, D., Nardone, M. R., & Folco, U. D. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820952107 · Cited by 5
Moreno-Fernández, J., Gómez, F. J., Moreno, M. Á. G., & Castano, J. P. (2016) · Journal of Diabetes Research · doi:10.1155/2016/4171789 · Cited by 5
Insulin Pump Therapy in Children with Type 1 Diabetes: The Dark Side of the Moon
Scaramuzza, A. E., Dell'Acqua, M., Macedoni, M., & Zuccotti, G. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700435 · Cited by 5
The Bionic Pancreas: Novel Perspectives on Insulin Replacement Therapies
Denecke, C. (2015) · Transplantation · doi:10.1097/tp.0000000000000544 · Cited by 7
A guide for the pharmacist's role in insulin pump management during transitions of care
Clements, J. N., Castelli, G., Meade, L. T., & ODOM, J. M. (2020) · JACCP JOURNAL OF THE AMERICAN COLLEGE OF CLINICAL PHARMACY · doi:10.1002/jac5.1352 · Cited by 4
Yang, Z., Chan, Y., Chan, D. S., Wu, C., Wang, Z., Jiang, Y., Liu, D., Xia, Z., Zhang, L., Cai, Y., et al. (2024) · Small Methods · doi:10.1002/smtd.202400159 · Cited by 4
An electrochemical continuous glucose monitoring sensor utilizing ferrocene-derivative as a mediator
Nayak, K. K., Dorai, V. K., Pradhan, R. K., Jhunjhunwala, S., & Bhat, N. (2025) · Microchemical Journal · doi:10.1016/j.microc.2025.113795 · Cited by 4
de Jong, L. A., Li, X., Emamipour, S., van der Werf, S., Postma, M. J., van Dijk, P. R., & Feenstra, T. (2024) · PharmacoEconomics · doi:10.1007/s40273-024-01388-6 · Cited by 7
Glucose monitoring in diabetes: from clinical studies to real‐world practice
Sagar, R. C., Abbas, A., & Ajjan, R. (2019) · Practical Diabetes · doi:10.1002/pdi.2215 · Cited by 5
A general view of epidemiology of hypoglycemia in type 1 and type 2 diabetes mellitus
Brož, J., & Urbanová, J. (2019) · Vnitřní lékařství · doi:10.36290/vnl.2019.050 · Cited by 5
Haddadi, D., Rosolowsky, E. T., Pacaud, D., McKeen, J. A., Young, K., Madrick, B., Domaschuk, L., Sargious, P. M., Conroy, S., & Senior, P. A. (2020) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2020.08.097 · Cited by 5
Lal, R., & Leelarathna, L. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.2502 · Cited by 5
Yap, P. X. C., Koh, L., Gallagher, P., & Lum, Z. K. (2021) · Journal of Diabetology · doi:10.4103/jod.jod_49_21 · Cited by 5
Insulin Pump Alarms During Adverse Events: A Qualitative Descriptive Study
Estock, J. L., Codario, R. A., Zupa, M. F., Keddem, S., & Rodriguez, K. L. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231209999 · Cited by 4
Borges, L. P., de Jesus, P. C., de Souza, J. B., Silva, D. M. R. R., Moura, P. H. M., Santos, R. S., Barreto, M. D. S., Guimarães, A. G., Santana, L. A. D. M., Fonseca, D. L. M., et al. (2024) · Life · doi:10.3390/life14030320 · Cited by 6
Georga, E. I., Fotiadis, D. I., & Tigas, S. K. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-804831-3.00001-7 · Cited by 4
Cameron, F. J., Moore, B., & Gillam, L. H. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12786 · Cited by 6
The Future of the Artificial Pancreas
Thabit, H., & Hovorka, R. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0297 · Cited by 6
Eleftheriadou, I., Didangelos, T., Pappas, A. C., Anastasiou, E., Vasilopoulos, C., Zoupas, C., Manes, C., Tsatsoulis, A. A., Benroubi, M., Pangalos, E., et al. (2019) · HORMONES · doi:10.1007/s42000-019-00153-1 · Cited by 5
Melidonis, A. J., Kamaratos, A. V., Angelidi, A. M., Thomakos, P., Vrakas, S., Bakalis, J., Fousteris, E., & Iraklianou, S. A. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0309 · Cited by 6
Pedone, E., Laurenzi, A., Allora, A., Bolla, A. M., & Caretto, A. (2020) · Exploration of Medicine · doi:10.37349/emed.2020.00021 · Cited by 3
“RCTs of T2D patients treated with CSII have shown conflicting results [14], and subsequent meta-analyses have failed to show significant reductions of HbA1c or hypoglycemia [62].”
ResultKişioğlu, S. V., Demır, A. S., Tüfekçi, D., Günay, Y., Coşkun, H., Üçüncü, Ö., Nuhoğlu, İ., Koçak, M., Karakullukçu, S., & Ersöz, H. Ö. (2021) · Archives of Medical Science - Atherosclerotic Diseases · doi:10.5114/amsad.2021.105562 · Cited by 5
Simmons, K., & Riddley, S. (2022) · Primary Care Clinics in Office Practice · doi:10.1016/j.pop.2021.11.005 · Cited by 15
Ghaffar, A., Munir, B., Jahangeer, M., Ashiq, M., Qamar, S. A., & Ahmad, B. M. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-99291-6.00020-7 · Cited by 4
Pros and cons of continous glucose monitoring
Ciechański, M., Witkowska, E., Ostańska, A., Szafran, A., Wiśniewska, K., Piasek, L., Godek, G., Więcław, K., Stańko, K., & Terelak, W. (2023) · Journal of Medical Science · doi:10.20883/medical.e873 · Cited by 4
Tremamunno, S., Tartaglione, L., Telesca, A., Rizzi, A., Felici, T., Mazzotta, F. A., Vita, A. D., Rizzo, E., Cambise, N., Belmusto, A., et al. (2024) · Endocrine · doi:10.1007/s12020-023-03651-w · Cited by 5
Li, S., Tao, Y., Yang, M., Zhao, H., Si, M., Cui, W., & Wang, H. (2024) · Frontiers in Endocrinology · doi:10.3389/fendo.2024.1286736 · Cited by 4
Yeşil, F., & Özçelik, Ç. Ç. (2024) · Balkan Medical Journal · doi:10.4274/balkanmedj.galenos.2024.2024-2-115 · Cited by 9
Insulin delivery devices in diabetes management: Applications and advancements
Yang, R., Yang, Z., Chi, J., & Ya, Z. (2025) · Intelligent Pharmacy · doi:10.1016/j.ipha.2025.02.002 · Cited by 8
Aristizábal, N., Ramírez, Á., Hincapié-García, J. A., Laiton, E., Aristizábal, C., Cuesta, D., Monsalve, C., Hincapié, G. M. S., Zapata, E., Abad, V., et al. (2015) · Endocrinología y Nutrición · doi:10.1016/j.endonu.2015.05.014 · Cited by 5
Insulin Pump in Difficult to Control Type 2 Diabetes: A Single Center, Five Years' Experience
Singh, P., Pandey, D., & Trivedi, N. (2018) · Cureus · doi:10.7759/cureus.3240 · Cited by 3
Lepore, G., & Tomaselli, L. G. (2014) · Frontiers in diabetes · doi:10.1159/000363486 · Cited by 3
Maurizi, A. R., SURACI, C., Pitocco, D., Schiaffini, R., Tubili, C., Morviducci, L., Giordano, R., Manfrini, S., Lauro, D., Frontoni, S., et al. (2015) · Journal of Diabetes · doi:10.1111/1753-0407.12321 · Cited by 5
“Several studies have shown improved glycemic control with CSII; however, its effectiveness regarding other outcomes remains contentious.(5,6)”
BackgroundGjessing, H. J., Jørgensen, U. L., Møller, C. C., Pedersen, J., Grodum, E., & Schousboe, K. (2014) · Journal of Diabetes Mellitus · doi:10.4236/jdm.2014.44042 · Cited by 4
Update on Treatment of Type 1 Diabetes in Childhood
Ludvigsson, J. (2013) · Current Pediatrics Reports · doi:10.1007/s40124-013-0012-x · Cited by 4
Bioengineering the Pancreas: Cell-on-Scaffold Technology
Peloso, A., Citro, A., Oldani, G., Brambilla, S., Piemonti, L., & Cobianchi, L. (2017) · InTech eBooks · doi:10.5772/intechopen.70990 · Cited by 5
Mooney, S. P., Booth, G. L., Shulman, R. M., Na, Y., Weisman, A., Shah, B. R., Perkins, B. A., & Lipscombe, L. L. (2021) · Diabetic Medicine · doi:10.1111/dme.14618 · Cited by 4
Pregestational Diabetes Mellitus
Zajdenverg, L., & Negrato, C. A. (2021) · Springer eBooks · doi:10.1007/978-3-030-83434-0_22 · Cited by 3
(2012) · Drug and Therapeutics Bulletin · doi:10.1136/dtb.2012.09.0130 · Cited by 3
Sun, S., Cui, W., Dong, Y., & Wang, Q. (2019) · Macromolecular Research · doi:10.1007/s13233-019-7061-0 · Cited by 3
Obradovic, M. M., Sudar-Milovanovic, E. M., Gluvic, Z. M., Gojobori, T., Essack, M., & Isenović, E. R. (2020) · Springer eBooks · doi:10.1007/978-3-030-53370-0_52 · Cited by 3
Reducing Hypoglycemia in Type 1 Diabetes: An Incremental Step Forward
Hirsch, I. B. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0174 · Cited by 3
Botero, J. F., Vásquez, L. M., Blanco, V. M., Cuesta, D., Rincón, A. R., Bedoya, J., & Palacio, A. (2021) · Endocrinología Diabetes y Nutrición · doi:10.1016/j.endinu.2020.11.006 · Cited by 4
Insulin’s Legacy: A Century of Breakthroughs and Innovation
Hadid, S. A., Zhang, E., Frishman, W. H., & Brutsaert, E. F. (2024) · Cardiology in Review · doi:10.1097/crd.0000000000000680 · Cited by 4
Time to Initiation of Omnipod DASH® vs. Tubed Insulin Pump Therapy: A Time-and-Motion Study
Gordon, C., Graf, M., Hopley, C. D. J., Jennings, P. J., & Littlewood, M. (2025) · Diabetes Therapy · doi:10.1007/s13300-024-01686-4 · Cited by 3
Kapellen, T. M., Heidtmann, B., Holl, R. W., & Kiess, W. (2013) · Der Diabetologe · doi:10.1007/s11428-012-0972-4 · Cited by 2
NOCTURNAL HYPOGLYCEMIA – THE MAIN INDICATION FOR INSULIN PUMP THERAPY IN ADULTHOOD
Baretić, M., Kraljević, I., & Renar, I. P. (2016) · Acta Clinica Croatica · doi:10.20471/acc.2016.55.01.14 · Cited by 5
“4%), with a median of 7 (4-21) hypoglycemias over a period of 6 days, and a median of 50% (0-100%) nocturnal hypoglycemia events.”
BackgroundEmergency Department Ondansetron Use in Children with Type 1 Diabetes Mellitus and Vomiting
Leung, J., Perlman, K., Rumantir, M., & Freedman, S. B. (2014) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2014.10.020 · Cited by 2
Dayal, D., Sharma, S., Sachdeva, N. K., Bhalla, A., & Attri, S. V. (2014) · Journal of Diabetology · doi:10.4103/2078-7685.198299 · Cited by 2
Myers, A. K., Garnica, P., & Ling, J. (2018) · American Journal of Therapeutics · doi:10.1097/mjt.0000000000000667 · Cited by 5
Rautiainen, P., Tirkkonen, H., & Laatikainen, T. K. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0027 · Cited by 2
Insulin Pump Therapy: Patient Practices and Glycemic Outcomes
Edem, D., McCarthy, P., Ng, J. M., Stefanović-Račić, M., & Korytkowski, M. T. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818778869 · Cited by 2
Coronel-Restrepo, N., Blanco, V. M., Palacio, A., Rincón, A. R., Arbeláez, S., Duque, V., Pino, J. J., Carvajal, J. A., Bedoya, J., Cuesta, D., et al. (2021) · Endocrinología Diabetes y Nutrición (English ed ) · doi:10.1016/j.endien.2021.11.009 · Cited by 4
Pathophysiology and Management of Type 1 Diabetes
Georga, E. I., Fotiadis, D. I., & Tigas, S. K. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-804831-3.00002-9 · Cited by 4
Leal‐Lopes, C., Mantovani, M. D. C., & Sogayar, M. C. (2018) · Vigilância Sanitária em Debate · doi:10.22239/2317-269x.01056 · Cited by 2
U-500: A Convenient Insulin for a Convenience Food Nation
Tannock, L. R. (2013) · Endocrine Practice · doi:10.4158/ep12386.ed · Cited by 2
Insulin Pumps and Artificial Pancreas
Taleb, N., Gingras, V., & RABASA-LHORET, R. P. R. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.65407-7 · Cited by 3
Are We Ready to Move Beyond Capillary Glucose Testing and Insulin Injections?
Galindo, R. J., Migdal, A. L., & Umpierrez, G. E. (2019) · The American Journal of the Medical Sciences · doi:10.1016/j.amjms.2019.08.010 · Cited by 2
Insulin Management in Type 1 Diabetes
Crasto, W., Jarvis, J., & Davies, M. J. (2016) · Springer eBooks · doi:10.1007/978-3-319-10939-8_5 · Cited by 1
Ríos, Y. Y., García-Rodríguez, J. A., Sanchez, E. N., Alanís, A. Y., Ruiz-Velazquez, E., & PARDO-GARCIA, A. (2022) · Advances in Electrical and Computer Engineering · doi:10.4316/aece.2022.03001 · Cited by 1
Knowledge, Attitude, and Practice of Insulin Pump Among Non-Endocrinology Nurses in South China
Mo, C., Huang, X., Lü, X., Zhou, Y., Su, Y., & Zhang, H. (2023) · Diabetes Metabolic Syndrome and Obesity · doi:10.2147/dmso.s414327 · Cited by 1
Wang, W. T., & Loh, W. J. (2025) · Current Opinion in Endocrinology Diabetes and Obesity · doi:10.1097/med.0000000000000940 · Cited by 2
Li, Z., Jiang, J., Zhu, Z., Luo, C., Xu, C., Chen, C., Ren, G., Huang, R., & He, D. (2026) · Frontiers in Endocrinology · doi:10.3389/fendo.2026.1825247 · Cited by 1
Metadata
- Authors
- Yeh, H.-C., Brown, T. T., Maruthur, N., Ranasinghe, P., Berger, Z., Suh, Y. D., Wilson, L. M., Haberl, E. B., Brick, J., Bass, E. B., & Golden, S. H.
- Affiliations
- Johns Hopkins University (US)
- Harvard University (US)
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2012-09-04
- Volume
- 157
- Issue
- 5
- Pages
- 336-347
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2035018400
- Cited by
- 493
- References
- 72
- Citations by year
- 2026: 14 · 2025: 15 · 2024: 27 · 2023: 19 · 2022: 31 · 2021: 38 · 2020: 45 · 2019: 44 · 2018: 48 · 2017: 36 · 2016: 48 · 2015: 46 · 2014: 48 · 2013: 32 · 2012: 2
- FWCI
- 5.63
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by-nc-nd
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Repositorio UTB (submittedVersion, cc-by-nc-nd)
- Funders
- National Institute of Diabetes and Digestive and Kidney Diseases (P30DK079637)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- diabetes mellitus, insulin delivery, insulin pump therapy, multiple daily insulin injections, sensor-augmented pump, continuous glucose monitoring, self-monitoring of blood glucose, glycemic control, HbA1c, hypoglycemia, type 1 diabetes, type 2 diabetes, intensive insulin therapy, rapid-acting insulin analogs, children and adults, comparative effectiveness
- MeSH terms
- Blood Glucose, Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2, Glycated Hemoglobin, Humans, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Monitoring, Physiologic, Blood Glucose Self-Monitoring, Treatment Outcome, Comparative Effectiveness Research
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.