Comparative Effectiveness and Safety of Methods of Insulin Delivery and Glucose Monitoring for Diabetes Mellitus: A Systematic Review and Meta-analysis
Open accessThe DOI matches its Crossref record; 75 of the 75 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Patients with diabetes mellitus need information about the effectiveness of innovations in insulin delivery and glucose monitoring. PURPOSE: To review how intensive insulin therapy (multiple daily injections [MDI] vs. rapid-acting analogue-based continuous subcutaneous insulin infusion [CSII]) or method of monitoring (self-monitoring of blood glucose [SMBG] vs. real-time continuous glucose monitoring [rt-CGM]) affects outcomes in types 1 and 2 diabetes mellitus. DATA SOURCES: MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials through February 2012 without language restrictions. STUDY SELECTION: 33 randomized, controlled trials in children or adults that compared CSII with MDI (n=19), rt-CGM with SMBG (n=10), or sensor-augmented insulin pump use with MDI and SMBG (n=4). DATA EXTRACTION: 2 reviewers independently evaluated studies for eligibility and quality and serially abstracted data. DATA SYNTHESIS: In randomized, controlled trials, MDI and CSII showed similar effects on hemoglobin A1c (HbA1c) levels and severe hypoglycemia in children or adults with type 1 diabetes mellitus and adults with type 2 diabetes mellitus. In adults with type 1 diabetes mellitus, HbA1c levels decreased more with CSII than with MDI, but 1 study heavily influenced these results. Compared with SMBG, rt-CGM achieved a lower HbA1c level (between-group difference of change, 0.26% [95% CI, 0.33% to 0.19%]) without any difference in severe hypoglycemia. Sensor-augmented insulin pump use decreased HbA1c levels more than MDI and SMBG did in persons with type 1 diabetes mellitus (between-group difference of change, 0.68% [CI, 0.81% to 0.54%]). Little evidence was available on other outcomes. LIMITATION: Many studies were small, of short duration, and limited to white persons with type 1 diabetes mellitus. CONCLUSION: Continuous subcutaneous insulin infusion and MDI have similar effects on glycemic control and hypoglycemia, except CSII has a favorable effect on glycemic control in adults with type 1 diabetes mellitus. For glycemic control, rt-CGM is superior to SMBG and sensor-augmented insulin pumps are superior to MDI and SMBG without increasing the risk for hypoglycemia. PRIMARY FUNDING SOURCE: Agency for Healthcare Research and Quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Rates and the clinical impact of hypoglycemia are frequently underestimated,1108”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
In the citing paper
“The frequency of hypoglycemia increases with intensive insulin targets, use of SUs, decreased caloric intake, delayed meals, exercise, alcohol consumption, CKD, T2D duration, and cognitive impairment.1108”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
In the citing paper
“but about 7% to 15% of insulin-treated persons with T2D experience at least 1 episode of hypoglycemia per year,1109 and 1% to 2% have severe hypoglycemia.1106,1108”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
In the citing paper
“Hyperinsulinemia, increased alcohol intake, starvation, and organ failure may be aggravating factors.1108,1200,1201”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
In the citing paper
“In persons with DM, iatrogenic hypoglycemia stems from an imbalance among insulin and/or insulinogenic (eg, SUs, glinides) therapy and food intake, physical activity, organ function (gluconeogenesis), and counter-regulation with glucagon and/or epinephrine (hypoglycemia-associated autonomic failure).”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
6 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., & Altman, D. G. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.06.005 · Cited by 19,575
Reduction in the incidence of type 2 diabetes with lifestyle intervention or metformin
(2002) · New England Journal of Medicine · doi:10.1056/nejmoa012512 · Cited by 19,011
Turner, R. C., Fox, C., Matthews, McElroy, H. H., Cull, C. A., Holman, R. R., Neil, P., Hadden, D. R., Wright, D., Manley, E., et al. (1998) · The Lancet · Cited by 8,419
Downs, S. H., & Black, N. (1998) · Journal of Epidemiology and Community Health · doi:10.1136/jech.52.6.377 · Cited by 8,252
Research works printed but not linked: 2
- 20587584N Engl J Med. 363N Engl J Med. 2010;363:383-4. [PMID: 20587584]
- Diabetes Prevention Program Research Group. Reduction in domized treat-to-target study. W C Knowler, E Barrett-Connor, S E Fowler, R F Hamman, J M Lachin, E A Walker, 18715214Diabetes Technol Ther. 10Knowler WC, Barrett-Connor E, Fowler SE, Hamman RF, Lachin JM, Walker EA, et al; Diabetes Prevention Program Research Group. Reduction in domized treat-to-target study. Diabetes Technol Ther. 2008;10:377-83. [PMID: 18715214]
Cited by
Standards of medical care in diabetes—2014
American Diabetes Association (2014) · Diabetes Care · doi:10.2337/dc14-s014 · Cited by 4,572
Standards of medical care in diabetes—2013
American Diabetes Association (2013) · Diabetes Care · doi:10.2337/dc13-s011 · Cited by 4,369
“The technologymay be particularly useful in thosewith hypoglycemia unawareness and/or frequent episodes of hypoglycemia, although studies as yet have not shown significant reductions in severe hypoglycemia (70).”
BackgroundResultAtkinson, M. A., Eisenbarth, G. S., & Michels, A. W. (2014) · The Lancet · doi:10.1016/s0140-6736(13)60591-7 · Cited by 2,931
9. Pharmacologic Approaches to Glycemic Treatment: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s009 · Cited by 1,555
9. Pharmacologic Approaches to Glycemic Treatment: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s009 · Cited by 972
Type 1 Diabetes Through the Life Span: A Position Statement of the American Diabetes Association
Chiang, J. L., Kirkman, M. S., Laffel, L. M. B., Peters, A. L., & Authors, O. B. O. T. T. 1. D. S. (2014) · Diabetes Care · doi:10.2337/dc14-1140 · Cited by 965
9. Pharmacologic Approaches to Glycemic Treatment: Standards of Medical Care in Diabetes—2020
American Diabetes Association (2020) · Diabetes Care · doi:10.2337/dc20-s009 · Cited by 914
9. Pharmacologic Approaches to Glycemic Treatment: Standards of Care in Diabetes—2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s009 · Cited by 851
Differentiation of diabetes by pathophysiology, natural history, and prognosis
Skyler, J. S., Bakris, G. L., Bonifacio, E., Darsow, T., Eckel, R. H., Groop, L., Groop, P.-H., Handelsman, Y., Insel, R. A., Mathieu, C., et al. (2017) · Diabetes · doi:10.2337/db16-0806 · Cited by 823
“There are no significant generalizable differences in efficacy or safety between the two approaches (123).”
Background6. Glycemic Targets: Standards of Medical Care in Diabetes—2018
American Diabetes Association (2018) · Diabetes Care · doi:10.2337/dc18-s006 · Cited by 762
9. Pharmacologic Approaches to Glycemic Treatment: Standards of Medical Care in Diabetes—2019
American Diabetes Association (2019) · Diabetes Care · doi:10.2337/dc19-s009 · Cited by 739
9. Pharmacologic Approaches to Glycemic Treatment: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Bajaj, M., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s009 · Cited by 728
8. Pharmacologic Approaches to Glycemic Treatment: Standards of Medical Care in Diabetes—2018
American Diabetes Association (2018) · Diabetes Care · doi:10.2337/dc18-s008 · Cited by 699
9. Pharmacologic Approaches to Glycemic Treatment: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Gaglia, J. L., Hilliard, M. E., Johnson, E. L., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s009 · Cited by 662
Hering, B. J., Clarke, W. R., Bridges, N. D., Eggerman, T. L., Alejandro, R., Bellin, M. D., Chaloner, K., Czarniecki, C. W., Goldstein, J. S., Hunsicker, L. G., et al. (2016) · Diabetes Care · doi:10.2337/dc15-1988 · Cited by 645
Beck, R. W., Riddlesworth, T. D., Ruedy, K., Ahmann, A., Haller, S., Kruger, D., McGill, J. B., Polonsky, W., Price, D., Aronoff, S., et al. (2017) · Annals of Internal Medicine · doi:10.7326/m16-2855 · Cited by 635
Chamberlain, J. J., Rhinehart, A. S., Shaefer, C. F., & Neuman, A. (2016) · Annals of Internal Medicine · doi:10.7326/m15-3016 · Cited by 631
Heinemann, L., Freckmann, G., Ehrmann, D., Faber-Heinemann, G., Guerra, S., Waldenmaier, D., & Hermanns, N. (2018) · The Lancet · doi:10.1016/s0140-6736(18)30297-6 · Cited by 522
Chiang, J. L., Maahs, D. M., Garvey, K. C., Hood, K. K., Laffel, L. M., Weinzimer, S. A., Wolfsdorf, J. I., & Schatz, D. (2018) · Diabetes Care · doi:10.2337/dci18-0023 · Cited by 509
Blonde, L., Umpierrez, G. E., Reddy, S. S., McGill, J. B., Berga, S. L., Bush, M., Chandrasekaran, S., DeFronzo, R. A., Einhorn, D., Galindo, R. J., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.08.002 · Cited by 507
ACOG Practice Bulletin No. 201: Pregestational Diabetes Mellitus
(2018) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000002960 · Cited by 470
8. Pharmacologic Approaches to Glycemic Treatment
American Diabetes Association (2017) · Diabetes Care · doi:10.2337/dc17-s011 · Cited by 458
Glycemic Variability: How Do We Measure It and Why Is It Important?
Suh, S., & Kim, J. H. (2015) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2015.39.4.273 · Cited by 439
Bekiari, E., Kitsios, K., Thabit, H., Tauschmann, M., Athanasiadou, E., Karagiannis, T., Haidich, A.-B., Hovorka, R., & Tsapas, A. (2018) · BMJ · doi:10.1136/bmj.k1310 · Cited by 437
Diabetes: Advances in Diagnosis and Treatment
Nathan, D. M. (2015) · JAMA · doi:10.1001/jama.2015.9536 · Cited by 384
Maiorino, M. I., Signoriello, S., Maio, A., Chiodini, P., Bellastella, G., Scappaticcio, L., Longo, M., Giugliano, D., & Esposito, K. (2020) · Diabetes Care · doi:10.2337/dc19-1459 · Cited by 364
7. Diabetes Technology: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358
“02]) and for reducing severe hypoglycemia rates in children and adults (133).”
Background7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348
4D printing and stimuli-responsive materials in biomedical aspects
Lui, Y. S., Sow, W. T., Tan, L. P., Wu, Y., Lai, Y., & Li, H. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.05.005 · Cited by 333
Aleppo, G., Ruedy, K. J., Riddlesworth, T. D., Kruger, D. F., Peters, A. L., Hirsch, I., Bergenstal, R. M., Toschi, E., Ahmann, A. J., Shah, V. N., et al. (2017) · Diabetes Care · doi:10.2337/dc16-2482 · Cited by 329
Real-time continuous glucose monitoring among participants in the T1D Exchange clinic registry
Wong, J. C., Foster, N. C., Maahs, D. M., Raghinaru, D., Bergenstal, R. M., Ahmann, A. J., Peters, A. L., Bode, B. W., Aleppo, G., Hirsch, I. B., et al. (2014) · Diabetes Care · doi:10.2337/dc14-0303 · Cited by 318
Bergenstal, R. M., Ahmann, A. J., Bailey, T., Beck, R. W., Bissen, J., Buckingham, B., Deeb, L., Dolin, R. H., Garg, S. K., Goland, R., et al. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0051 · Cited by 307
7. Diabetes Technology: Standards of Care in Diabetes — 2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301
Intensive glucose control versus conventional glucose control for type 1 diabetes mellitus
Fullerton, B., Jeitler, K., Seitz, M., Horvath, K., Berghold, A., & Siebenhofer, A. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009122.pub2 · Cited by 299
7. Diabetes Technology: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281
American Diabetes Association (2017) · Diabetes Care · doi:10.2337/dc17-s009 · Cited by 271
9. pharmacologic approaches to glycemic treatment: standards of care in diabetes—2026
American Diabetes Association Professional Practice Committee for Diabetes*, Bajaj, M., McCoy, R. G., Balapattabi, K., Bannuru, R. R., Bellini, N. J., Bennett, A. K., Beverly, E. A., Briggs Early, K., ChallaSivaKanaka, S., et al. (2026) · Diabetes Care · doi:10.2337/dc26-s009 · Cited by 263
(2015) · doi:10.1136/bmj.h3234 · Cited by 258
Peters, A. L., Ahmann, A. J., Battelino, T., Evert, A., Hirsch, I. B., Murad, M. H., Winter, W. E., & Wolpert, H. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2016-2534 · Cited by 250
7. Diabetes Technology: Standards of Medical Care in Diabetes—2020
American Diabetes Association (2020) · Diabetes Care · doi:10.2337/dc20-s007 · Cited by 250
Reutrakul, S., Thakkinstian, A., Anothaisintawee, T., Chontong, S., Borel, A.-L., Perfect, M. M., Janovsky, C. C. P. S., Kessler, R., Schultes, B., Harsch, I. A., et al. (2016) · Sleep Medicine · doi:10.1016/j.sleep.2016.03.019 · Cited by 238
“[57] Yeh HC, Brown TT, Maruthur N et al.”
2021 Clinical Practice Guidelines for Diabetes Mellitus of the Korean Diabetes Association
Hur, K. Y., Moon, M. K., Park, J. S., Kim, S.-K., Lee, S.-H., Yun, J.-S., Baek, J. H., Noh, J., Lee, B.-W., Oh, T. J., et al. (2021) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2021.0156 · Cited by 226
Ruedy, K. J., Parkin, C. G., Riddlesworth, T. D., & Graham, C. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817704445 · Cited by 225
“Diabetes & Glandular Disease Clinic, San Antonio, TX (16): Mark Kipnes (I); Stacie Haller (C); Terri Ryan (C) Rocky Mountain Diabetes and Osteoporosis Center, Idaho Falls, ID (9): David Liljenquist (I); Heather Judge (C); Jean Halford (C) Research Institute of Dallas, Dallas, TX (8): Stephen Aronoff (I); Satanya Brook…”
7. Approaches to Glycemic Treatment
American Diabetes Association (2016) · Diabetes Care · doi:10.2337/dc16-s010 · Cited by 225
American Diabetes Association (2016) · Diabetes Care · doi:10.2337/dc16-s008 · Cited by 215
Minimizing Hypoglycemia in Diabetes
International Hypoglycaemia Study Group (2015) · Diabetes Care · doi:10.2337/dc15-0279 · Cited by 209
Zhou, W., Qiao, Z., Nazarzadeh Zare, E., Huang, J., Zheng, X., Sun, X., Shao, M., Wang, H., Wang, X., Chen, D., et al. (2020) · Journal of Medicinal Chemistry · doi:10.1021/acs.jmedchem.9b02115 · Cited by 209
American Diabetes Association (2015) · Diabetes Care · doi:10.2337/dc15-s009 · Cited by 205
7. Diabetes Technology: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s007 · Cited by 202
ISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
“A meta-analysis by Yeh et al found no difference between insulin pump therapy and MDI in regards to glycemic control attained or rates of severe hypoglycemia.(46) As these metanalyses are based on clinical trial data obtained prior to 2008, the pumps utilized are at least 10-years older than current technology availab…”
MethodFonseca, V. A., Grunberger, G., Anhalt, H., Bailey, T. S., Blevins, T., Garg, S. K., Handelsman, Y., Hirsch, I. B., Orzeck, E. A., Roberts, V. L., et al. (2016) · Endocrine Practice · doi:10.4158/ep161392.cs · Cited by 195
7. Approaches to Glycemic Treatment
American Diabetes Association (2015) · Diabetes Care · doi:10.2337/dc15-s010 · Cited by 181
7. Diabetes Technology: Standards of Medical Care in Diabetes—2019
American Diabetes Association (2019) · Diabetes Care · doi:10.2337/dc19-s007 · Cited by 179
Insulin Therapy in Adults with Type 1 Diabetes Mellitus: a Narrative Review
Janež, A., Guja, C., Mitrakou, A., Lalic, N., Tankova, T., Czupryniak, L., Tabák, A. G., Prazny, M., Martinka, E., & Smircic-Duvnjak, L. (2020) · Diabetes Therapy · doi:10.1007/s13300-019-00743-7 · Cited by 177
Bergenstal, R. M., Ahmann, A. J., Bailey, T., Beck, R. W., Bissen, J., Buckingham, B., Deeb, L., Dolin, R. H., Garg, S. K., Goland, R., et al. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700234 · Cited by 166
Hypoglycemia in diabetes: An update on pathophysiology, treatment, and prevention
Nakhleh, A., & Shehadeh, N. (2021) · World Journal of Diabetes · doi:10.4239/wjd.v12.i12.2036 · Cited by 154
Technology in the management of type 1 diabetes mellitus — current status and future prospects
Tauschmann, M., & Hovorka, R. (2018) · Nature Reviews Endocrinology · doi:10.1038/s41574-018-0044-y · Cited by 185
Nielsen, E. J. B., Yoshida, S., Kamei, N., Iwamae, R., Khafagy, E., Olsen, J., Rahbek, U. L., Pedersen, B. L., Takayama, K., & Takeda‐Morishita, M. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.06.022 · Cited by 151
Glucose-responsive microneedle patch for closed-loop dual-hormone delivery in mice and pigs
Yang, C., Sheng, T., Hou, W., Zhang, J., Cheng, L., Wang, H., Liu, W., Wang, S., Yu, X., Zhang, Y., et al. (2022) · Science Advances · doi:10.1126/sciadv.add3197 · Cited by 156
Improving the clinical value and utility of CGM systems: issues and recommendations
Petrie, J. R., Peters, A. L., Bergenstal, R. M., Holl, R. W., Fleming, G. A., & Heinemann, L. (2017) · Diabetologia · doi:10.1007/s00125-017-4463-4 · Cited by 149
Recent advances in optical sensors for continuous glucose monitoring
Ahmed, I., Jiang, N., Shao, X., Elsherif, M., Alam, F., Salih, A. E., Butt, H., & Yetisen, A. K. (2022) · Sensors & Diagnostics · doi:10.1039/d1sd00030f · Cited by 152
Neuronal damage and cognitive impairment associated with hypoglycemia: An integrated view
Languren, G., Montiel, T., Julio-Amilpas, A., & Massieu, L. (2013) · Neurochemistry International · doi:10.1016/j.neuint.2013.06.018 · Cited by 156
“…levels and to optimize the delivery of insulin or insulin analogues have not succeeded in completely preventing the occurrence of repeated episodes of hypoglycemia, despite their success in reducing hyperglycemia (Fatourechi et al., 2009; Yeh et al., 2012, see Section 5 in the present review).”
Recent progress in design and preparation of glucose-responsive insulin delivery systems
Shen, D., Yu, H., Wang, L., Khan, A., Haq, F., Chen, X., Huang, Q. Y., & Teng, L. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.02.014 · Cited by 146
Improving the Clinical Value and Utility of CGM Systems: Issues and Recommendations
Petrie, J. R., Peters, A. L., Bergenstal, R. M., Holl, R. W., Fleming, G. A., & Heinemann, L. (2017) · Diabetes Care · doi:10.2337/dci17-0043 · Cited by 135
Therapies for Type 1 Diabetes: Current Scenario and Future Perspectives
Pathak, V., Pathak, N., O’Neill, C. L., Guduric‐Fuchs, J., & Medina, R. J. (2019) · Clinical Medicine Insights Endocrinology and Diabetes · doi:10.1177/1179551419844521 · Cited by 174
Bailey, T. S., Grunberger, G., Bode, B. W., Handelsman, Y., Hirsch, I. B., Jovanovič, L., Roberts, V. L., Rodbard, D., Tamborlane, W. V., & Walsh, J. S. A. (2016) · Endocrine Practice · doi:10.4158/ep151124.cs · Cited by 151
Telemedicine in the Management of Type 1 Diabetes
Xu, T., Pujara, S., Sutton, S., & Rhee, M. (2018) · Preventing Chronic Disease · doi:10.5888/pcd15.170168 · Cited by 124
Continuous Glucose Monitoring: A Brief Review for Primary Care Practitioners
Ajjan, R., Slattery, D., & Wright, E. (2019) · Advances in Therapy · doi:10.1007/s12325-019-0870-x · Cited by 120
Wan, W., Skandari, M. R., Minc, A., Nathan, A. G., Winn, A., Zarei, P., O’Grady, M., & Huang, E. S. (2018) · Diabetes Care · doi:10.2337/dc17-1821 · Cited by 118
Leow, Z. Z. X., Guelfi, K. J., Davis, E. A., Jones, T. W., & Fournier, P. A. (2018) · Diabetic Medicine · doi:10.1111/dme.13663 · Cited by 115
Pala, L., Dicembrini, I., & Mannucci, E. (2019) · Acta Diabetologica · doi:10.1007/s00592-019-01326-5 · Cited by 112
Virk, S. A., Donaghue, K. C., Cho, Y. H., Benitez-Aguirre, P., Hing, S., Pryke, A., Chan, A., & Craig, M. E. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2015-3604 · Cited by 109
Insulin Pump Therapy Is Associated with Lower Rates of Retinopathy and Peripheral Nerve Abnormality
Zabeen, B., Craig, M. E., Virk, S. A., Pryke, A., Chan, A. K. F., Cho, Y. H., Benitez-Aguirre, P. Z., Hing, S., & Donaghue, K. C. (2016) · PLOS ONE · doi:10.1371/journal.pone.0153033 · Cited by 106
Tumminia, A., Crimi, S., Sciacca, L., Buscema, M., Frittitta, L., Squatrito, S., Vigneri, R., & Tomaselli, L. (2015) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.2557 · Cited by 100
Addala, A., Hanes, S., Naranjo, D., Maahs, D. M., & Hood, K. K. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211006476 · Cited by 100
Current Advances of Artificial Pancreas Systems: A Comprehensive Review of the Clinical Evidence
Moon, S. J., Jung, I., & Park, C.-Y. (2021) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2021.0177 · Cited by 98
How Can We Realize the Clinical Benefits of Continuous Glucose Monitoring?
Ajjan, R. A. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0021 · Cited by 97
Clinical review: insulin pump-associated adverse events in adults and children
Ross, P., Milburn, J., Reith, D. M., Wiltshire, E. J., & Wheeler, B. J. (2015) · Acta Diabetologica · doi:10.1007/s00592-015-0784-2 · Cited by 108
Chontong, S., Saetung, S., & Reutrakul, S. (2016) · Journal of Sleep Research · doi:10.1111/jsr.12393 · Cited by 98
“For example, carbohydrate counting was shown to reduce HbA1c by 0.35% compared with usual care (Bell et al., 2014), and the use of continuous subcutaneous insulin infusion was associated with 0.3% HbA1c reduction compared with multiple daily insulin injections (Yeh et al., 2012).”
MethodInfluentialCastellana, M., Parisi, C., Di Molfetta, S., Di Gioia, L., Natalicchio, A., Perrini, S., Cignarelli, A., Laviola, L., & Giorgino, F. (2020) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2019-001092 · Cited by 84
Pease, A., Lo, C., Earnest, A., Kiriakova, V., Liew, D., & Zoungas, S. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0417 · Cited by 83
Insulin Therapy in Children and Adolescents with Type 1 Diabetes
Malik, F. S., & Taplin, C. E. (2014) · Pediatric Drugs · doi:10.1007/s40272-014-0064-6 · Cited by 110
Matteucci, E., Giampietro, O., Covolan, V., Giustarini, D., Fanti, P., & Rossi, R. (2015) · Drug Design, Development and Therapy · doi:10.2147/dddt.s79322 · Cited by 81
Bratina, N., Forsander, G., Annan, F., Wysocki, T., Pierce, J. S., Calliari, L. E., Pacaud, D., Adolfsson, P., Dovč, K., Middlehurst, A., et al. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12743 · Cited by 96
Microneedle-array patch with pH-sensitive formulation for glucose-responsive insulin delivery
Luo, F., Chen, G., Xu, W., Zhou, D. R., Li, J.-X., Huang, Y., Lin, R., Gu, Z., & Du, J. (2021) · Nano Research · doi:10.1007/s12274-020-3273-z · Cited by 78
Heise, T., Zijlstra, E., Nosek, L., Rikte, T., & Haahr, H. (2017) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.12803 · Cited by 78
Current Eligibility Requirements for CGM Coverage Are Harmful, Costly, and Unjustified
Anderson, J. E., Gavin, J. R., & Kruger, D. F. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0303 · Cited by 77
Is insulin pump therapy effective in Type 1 diabetes?
Pickup, J. C. (2019) · Diabetic Medicine · doi:10.1111/dme.13793 · Cited by 77
Moon, J. S., Kang, S., Choi, J. H., Lee, K. A., Moon, J. H., Chon, S., Kim, D. J., Kim, H. J., Seo, J. A., Kim, M. K., et al. (2024) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2024.0249 · Cited by 90
Closed-Loop System in the Management of Diabetes: Past, Present, and Future
Shah, V. N., Shoskes, A., Tawfik, B., & Garg, S. K. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0193 · Cited by 86
Nimri, R., Nir, J., & Phillip, M. (2019) · American Journal of Therapeutics · doi:10.1097/mjt.0000000000001097 · Cited by 97
Mueller‐Godeffroy, E., Vonthein, R., Ludwig‐Seibold, C., Heidtmann, B., Boettcher, C., Kramer, M., Hessler, N., Hilgard, D., Lilienthal, E., Ziegler, A., et al. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12777 · Cited by 69
Evaluation of Pump Discontinuation and Associated Factors in the T1D Exchange Clinic Registry
Wong, J. C., Boyle, C., DiMeglio, L. A., Mastrandrea, L. D., Abel, K.-L., Cengiz, E., Cemeroglu, P. A., Aleppo, G., Largay, J. F., Foster, N. C., et al. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816663963 · Cited by 69
Rayan, M. N., Reddy, N., Verma, N., & Dungan, K. M. (2026) · PubMed · Cited by 110
Gomes, M. B., & Negrato, C. A. (2016) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2016.07.011 · Cited by 70
Neinstein, A., Wong, J., Look, H., Arbiter, B., Quirk, K., McCanne, S., Sun, Y., Blum, M., & Adi, S. (2016) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocv104 · Cited by 66
Benkhadra, K., Alahdab, F., Tamhane, S., Wang, Z., Prokop, L. J., Hirsch, I. B., Raccah, D., Riveline, J.-P., Kordonouri, O., & Murad, M. H. (2017) · Clinical Endocrinology · doi:10.1111/cen.13290 · Cited by 66
Continuous Glucose Monitoring and Global Reimbursement: An Update
Graham, C. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0096 · Cited by 62
Jones, C. W., Keil, L. G., Weaver, M. A., & Platts-Mills, T. F. (2014) · Systematic Reviews · doi:10.1186/2046-4053-3-126 · Cited by 61
Boscari, F., & Avogaro, A. (2021) · Reviews in Endocrine and Metabolic Disorders · doi:10.1007/s11154-021-09635-3 · Cited by 80
Metadata
- Authors
- Yeh, H.-C., Brown, T. T., Maruthur, N., Ranasinghe, P., Berger, Z., Suh, Y. D., Wilson, L. M., Haberl, E. B., Brick, J., Bass, E. B., & Golden, S. H.
- Affiliations
- Johns Hopkins University (US)
- Harvard University (US)
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2012-09-04
- Volume
- 157
- Issue
- 5
- Pages
- 336-347
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2035018400
- Semantic Scholar
- 6a9836e0bc9a84e7b30be275ad35b904df13faab
- Cited by
- 493
- References
- 72
- Citations by year
- 2026: 14 · 2025: 15 · 2024: 27 · 2023: 19 · 2022: 31 · 2021: 38 · 2020: 45 · 2019: 44 · 2018: 48 · 2017: 36 · 2016: 48 · 2015: 46 · 2014: 48 · 2013: 32 · 2012: 2
- FWCI
- 5.63
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by-nc-nd
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Repositorio UTB (submittedVersion, cc-by-nc-nd)
- Funders
- National Institute of Diabetes and Digestive and Kidney Diseases (P30DK079637)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- diabetes mellitus, insulin delivery, insulin pump therapy, multiple daily insulin injections, sensor-augmented pump, continuous glucose monitoring, self-monitoring of blood glucose, glycemic control, HbA1c, hypoglycemia, type 1 diabetes, type 2 diabetes, intensive insulin therapy, rapid-acting insulin analogs, children and adults, comparative effectiveness
- MeSH terms
- Blood Glucose, Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2, Glycated Hemoglobin, Humans, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Monitoring, Physiologic, Blood Glucose Self-Monitoring, Treatment Outcome, Comparative Effectiveness Research
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.