The DOI matches its OpenAlex record.
Diagnosis of central venous catheter-related sepsis. Critical level of quantitative tip cultures
Abstract
The results of a simplified quantitative broth dilution quantitative tip culture (QTC) of 331 central venous catheters were compared with clinical data prospectively recorded in critically III patients to diagnose bacteremic or nonbacteremic catheter-related sepsis (CRS) (36 catheters), as opposed to contamination (42 catheters) or simple colonization from a distant septic focus (seven catheters). Thirty-five of 36 catheters associated with CRS yielded 10(3) colony-forming units per milliliter (CFU/mL) or more, and 3.8 X 10(2) Candida organisms grew from one. In contrast, 5 X 10(2) CFU/mL or less grew from 37 of 42 contaminated catheters. A QTC of 10(3) CFU/mL or more was 97.5% sensitive and 88% specific for the diagnosis of CRS. The QTC appeared especially useful for the diagnosis of CRS secondary to blood-borne seeding of catheters, or associated with coagulase-negative staphylococci.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mermel, L. A., Allon, M., Bouza, E., Craven, D. E., Flynn, P., O'Grady, N. P., Raad, I. I., Rijnders, B. J. A., Sherertz, R. J., & Warren, D. K. (2009) · Clinical Infectious Diseases · doi:10.1086/599376 · Cited by 3,638
Guidelines for the management of intravascular catheter-related infections
Mermel, L. A., Farr, B. M., Sherertz, R. J., Raad, I. I., O'Grady, N., Harris, J. S., & Craven, D. E. (2001) · Clinical Infectious Diseases · doi:10.1086/320001 · Cited by 1,449
Merrer, J. (2001) · JAMA · doi:10.1001/jama.286.6.700 · Cited by 1,187
Calandra, T., & Cohen, J. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000168253.91200.83 · Cited by 839
Intravascular Complications of Central Venous Catheterization by Insertion Site
Parienti, J.-J., Mongardon, N., Mégarbane, B., Mira, J.-P., Kalfon, P., Gros, A., Marqué, S., Thuong, M., Pottier, V., Ramakers, M., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1500964 · Cited by 769
ESCMID∗ guideline for the diagnosis and treatment of biofilm infections 2014
Høiby, N., Bjarnsholt, T., Moser, C., Bassi, G. L., Coenye, T., Donelli, G., Hall-Stoodley, L., Holá, V., Imbert, C., Kirketerp-Møller, K., et al. (2015) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2014.10.024 · Cited by 726
Chaiyakunapruk, N., Veenstra, D. L., Lipsky, B. A., & Saint, S. (2002) · Annals of Internal Medicine · doi:10.7326/0003-4819-136-11-200206040-00007 · Cited by 610
Impact of systematic evaluation of pain and agitation in an intensive care unit*
Chanques, G., Jaber, S., Barbotte, E., Violet, S., Sebbane, M., Perrigault, P.-F., Mann, C., Lefrant, J.-Y., & Eledjam, J.-J. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000218416.62457.56 · Cited by 536
Guideline for Prevention of Intravascular-Device-Related Infections
Pearson, M. L., & The Hospital Infection Control Practices Advisory Committee (1996) · Infection Control and Hospital Epidemiology · doi:10.2307/30141155 · Cited by 531
Intravascular catheter-related infections: advances in diagnosis, prevention, and management
Raad, I., Hanna, H., & Maki, D. (2007) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(07)70235-9 · Cited by 525
Girou, E. (2000) · JAMA · doi:10.1001/jama.284.18.2361 · Cited by 506
Central Vein Catheter-Related Thrombosis in Intensive Care Patients
Timsit, J.-F., Farkas, J.-C., Boyer, J.-M., Martin, J.-B., Misset, B., Renaud, B., & Carlet, J. (1998) · Chest · doi:10.1378/chest.114.1.207 · Cited by 478
Timsit, J.-F., Schwebel, C., Bouadma, L., Geffroy, A., Garrouste-Orgeas, M., Pease, S., Herault, M.-C., Haouache, H., Calvino-Gunther, S., Gestin, B., et al. (2009) · JAMA · doi:10.1001/jama.2009.376 · Cited by 449
Infectious Complications of Indwelling Vascular Catheters
Raad, I. I., & Bodey, G. P. (1992) · Clinical Infectious Diseases · doi:10.1093/clinids/15.2.197 · Cited by 446
Eggimann, P., Harbarth, S., Constantin, M.-N., Touveneau, S., Chevrolet, J.-C., & Pittet, D. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02291-1 · Cited by 444
Mermel, L. A., McCormick, R. D., Springman, S. R., & Maki, D. G. (1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)90369-9 · Cited by 441
Blot, F., Nitenberg, G., Chachatty, E., Raynard, B., Germann, N., Antoun, S., Laplanche, A., Brun-Buisson, C., & Tancrède, C. (1999) · The Lancet · doi:10.1016/s0140-6736(98)11134-0 · Cited by 438
Self-citationParienti, J.-J., Thirion, M., Mégarbane, B., Souweine, B., Ouchikhe, A., Polito, A., Forel, J.-M., Marqué, S., Misset, B., Airapetian, N., et al. (2008) · JAMA · doi:10.1001/jama.299.20.2413 · Cited by 419
Catheter-related bloodstream infections
Gahlot, R., Gahlot, R., Nigam, C., Kumar, V., Yadav, G., Anupurba, S., Nigam, C., Kumar, V., Yadav, G., & Anupurba, S. (2014) · International Journal of Critical Illness and Injury Science · doi:10.4103/2229-5151.134184 · Cited by 403
Brun-Buisson, C., Legrand, P., Rauss, A., Richard, C., Montravers, F., Besbes, M., Meakins, J. L., Soussy, C. J., & Lemaire, F. (1989) · Annals of Internal Medicine · doi:10.7326/0003-4819-110-11-873 · Cited by 368
Self-citationPayen, J.-F., Bosson, J.-L., Chanques, G., Mantz, J., & Labarere, J. (2009) · Anesthesiology · doi:10.1097/aln.0b013e3181c0d4f0 · Cited by 368
Selenium, systemic immune response syndrome, sepsis, and outcome in critically ill patients
Forceville, X., Vitoux, D., Gauzit, R., Combes, A., Lahilaire, P., & Chappuis, P. (1998) · Critical Care Medicine · doi:10.1097/00003246-199809000-00021 · Cited by 338
Mimoz, O., Lucet, J.-C., Kerforne, T., Pascal, J., Souweine, B., Goudet, V., Mercat, A., Bouadma, L., Lasocki, S., Alfandari, S., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)00244-5 · Cited by 332
Meta-Analysis: Methods for Diagnosing Intravascular Device–Related Bloodstream Infection
Safdar, N., Fine, J. P., & Maki, D. G. (2005) · Annals of Internal Medicine · doi:10.7326/0003-4819-142-6-200503150-00011 · Cited by 329
Central venous catheter replacement strategies: A systematic review of the literature
Cook, D., Randolph, A., Kernerman, P., Cupido, C., King, D., Soukup, C., & Brun-Buisson, C. (1997) · Critical Care Medicine · doi:10.1097/00003246-199708000-00033 · Cited by 326
Self-citationSoufir, L., Timsit, J.-F., Mahe, C., Carlet, J., Regnier, B., & Chevret, S. (1999) · Infection Control & Hospital Epidemiology · doi:10.1086/501639 · Cited by 314
Lorente, L., Henry, C., Martín, M. M., Jiménez, A., & Mora, M. L. (2005) · Critical Care · doi:10.1186/cc3824 · Cited by 307
RENAUD, B., & BRUN-BUISSON, C. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.7.9912080 · Cited by 304
Self-citationColonization of dental plaque: A source of nosocomial infections in intensive care unit patients
Fourrier, F., Duvivier, B., Boutigny, H., Roussel-Delvallez, M., & Chopin, C. (1998) · Critical Care Medicine · doi:10.1097/00003246-199802000-00032 · Cited by 293
Blot, F., Schmidt, E., Nitenberg, G., Tancrède, C., Leclercq, B., Laplanche, A., & Andremont, A. (1998) · Journal of Clinical Microbiology · doi:10.1128/jcm.36.1.105-109.1998 · Cited by 289
Timsit, J.-F., Mimoz, O., Mourvillier, B., Souweine, B., Garrouste-Orgeas, M., Alfandari, S., Plantefeve, G., Bronchard, R., Troche, G., Gauzit, R., et al. (2012) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201206-1038oc · Cited by 268
Harbarth, S., Rutschmann, O., Sudre, P., & Pittet, D. (1998) · Archives of Internal Medicine · doi:10.1001/archinte.158.2.182 · Cited by 267
Bougnoux, M.-E., Kac, G., Aegerter, P., d’Enfert, C., Fagon, J.-Y., & CandiRea Study Group (2008) · Intensive Care Medicine · doi:10.1007/s00134-007-0865-y · Cited by 224
Guía Clínica Española del Acceso Vascular para Hemodiálisis
Ibeas, J., Roca-Tey, R., Vallespín, J., Moreno, T., Moñux, G., Martí-Monrós, A., del Pozo, J. L., Gruss, E., Ramírez de Arellano, M., Fontseré, N., et al. (2017) · Nefrología · doi:10.1016/j.nefro.2017.11.004 · Cited by 214
A Prospective Study of Agitation in a Medical-Surgical ICU
Jaber, S., Chanques, G., Altairac, C., Sebbane, M., Vergne, C., Perrigault, P.-F., & Eledjam, J.-J. (2005) · Chest · doi:10.1378/chest.128.4.2749 · Cited by 154
Rijnders, B. J., Peetermans, W. E., Verwaest, C., Wilmer, A., & Wijngaerden, E. V. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2212-x · Cited by 141
Nicotine withdrawal and agitation in ventilated critically ill patients
Lucidarme, O., Seguin, A., Daubin, C., Ramakers, M., Terzi, N., Beck, P., Charbonneau, P., & du Cheyron, D. (2010) · Critical Care · doi:10.1186/cc8954 · Cited by 85
Metadata
- Authors
- Brun‐Buisson, C.
- Venue
- Archives of Internal Medicine
- Publisher
- American Medical Association
- Published
- 1987-05-01
- Volume
- 147
- Issue
- 5
- Pages
- 873-877
- ISSN
- 0003-9926 (ISSN-L)
- OpenAlex
- W4256421868
- Cited by
- 519
- References
- 0
- FWCI
- 22.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.