Accuracy of Positron Emission Tomography for Diagnosis of Pulmonary Nodules and Mass Lesions: A Meta-analysis
The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
CONTEXT: Focal pulmonary lesions are commonly encountered in clinical practice, and positron emission tomography (PET) with the glucose analog 18-fluorodeoxyglucose (FDG) may be an accurate test for identifying malignant lesions. OBJECTIVE: To estimate the diagnostic accuracy of FDG-PET for malignant focal pulmonary lesions. DATA SOURCES: Studies published between January 1966 and September 2000 in the MEDLINE and CANCERLIT databases; reference lists of identified studies; abstracts from recent conference proceedings; and direct contact with investigators. STUDY SELECTION: Studies that examined FDG-PET or FDG with a modified gamma camera in coincidence mode for diagnosis of focal pulmonary lesions; enrolled at least 10 participants with pulmonary nodules or masses, including at least 5 participants with malignant lesions; and presented sufficient data to permit calculation of sensitivity and specificity were included in the analysis. DATA EXTRACTION: Two reviewers independently assessed study quality and abstracted data regarding prevalence of malignancy and sensitivity and specificity of the imaging test. Disagreements were resolved by discussion. DATA SYNTHESIS: We used a meta-analytic method to construct summary receiver operating characteristic curves. Forty studies met inclusion criteria. Study methodological quality was fair. Sample sizes were small and blinding was often incomplete. For 1474 focal pulmonary lesions of any size, the maximum joint sensitivity and specificity (the upper left point on the receiver operating characteristic curve at which sensitivity and specificity are equal) of FDG-PET was 91.2% (95% confidence interval, 89.1%-92.9%). In current practice, FDG-PET operates at a point on the summary receiver operating characteristic curve that corresponds approximately to a sensitivity and specificity of 96.8% and 77.8%, respectively. There was no difference in diagnostic accuracy for pulmonary nodules compared with lesions of any size (P =.43), for semiquantitative methods of image interpretation compared with qualitative methods (P =.52), or for FDG-PET compared with FDG imaging with a modified gamma camera in coincidence mode (P =.19). CONCLUSIONS: Positron emission tomography with 18-fluorodeoxyglucose is an accurate noninvasive imaging test for diagnosis of pulmonary nodules and larger mass lesions, although few data exist for nodules smaller than 1 cm in diameter. In current practice, FDG-PET has high sensitivity and intermediate specificity for malignancy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical Methods for Rates and Proportions
Fleiss, J. L., Levin, B., & Paik, M. C. (2003) · Wiley Series in Probability and Statistics · doi:10.1002/0471445428 · Cited by 18,646
Warburg, O. (1956) · Science · doi:10.1126/science.123.3191.309 · Cited by 13,425
Quantitative Synthesis in Systematic Reviews
Lau, J., Ioannidis, J. P. A., & Schmid, C. H. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-127-9-199711010-00008 · Cited by 2,517
Moses, L. E., Shapiro, D., & Littenberg, B. (1993) · Statistics in Medicine · doi:10.1002/sim.4780121403 · Cited by 1,405
Methods in Observational Epidemiology
Kelsey, J. L. (1986) · Cited by 1,307
Swensen, S. J. (1997) · Archives of Internal Medicine · doi:10.1001/archinte.1997.00440290031002 · Cited by 810
Dwamena, B. A., Sonnad, S. S., Angobaldo, J. O., & Wahl, R. L. (1999) · Radiology · doi:10.1148/radiology.213.2.r99nv46530 · Cited by 649
Prospective investigation of positron emission tomography in lung nodules.
Lowe, V. J., Fletcher, J. W., Gobar, L., Lawson, M., Kirchner, P., Valk, P., Karis, J., Hubner, K., Delbeke, D., Heiberg, E. V., et al. (1998) · Journal of Clinical Oncology · doi:10.1200/jco.1998.16.3.1075 · Cited by 552
Focal pulmonary abnormalities: evaluation with F-18 fluorodeoxyglucose PET scanning.
Patz, E. F., Lowe, V. J., Hoffman, J. M., Paine, S. S., Burrowes, P., Coleman, R. E., & Goodman, P. C. (1993) · Radiology · doi:10.1148/radiology.188.2.8327702 · Cited by 511
Formulating Questions and Locating Primary Studies for Inclusion in Systematic Reviews
Counsell, C. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-127-5-199709010-00008 · Cited by 505
Cited by
Brocken, P., van der Heijden, H. F. M., Dekhuijzen, P. N. R., Peters-Bax, L., & de Geus-Oei, L.-F. (2014) · Respiration · doi:10.1159/000347096 · Cited by 4,002
Recommendations on the Use of 18F-FDG PET in Oncology
Fletcher, J. W., Djulbegovic, B., Soares, H. P., Siegel, B. A., Lowe, V. J., Lyman, G. H., Coleman, R. E., Wahl, R., Paschold, J. C., Avril, N., et al. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.047787 · Cited by 1,101
Callister, M. E. J., Baldwin, D. R., Akram, A. R., Barnard, S., Cane, P., Draffan, J., Franks, K., Gleeson, F., Graham, R., Malhotra, P., et al. (2015) · Thorax · doi:10.1136/thoraxjnl-2015-207168 · Cited by 958
Clinical Applications of PET in Oncology
Rohren, E. M., Turkington, T. G., & Coleman, R. E. (2004) · Radiology · doi:10.1148/radiol.2312021185 · Cited by 859
Gould, M. K., Kuschner, W. G., Rydzak, C. E., Maclean, C. C., Demas, A. N., Shigemitsu, H., Chan, J. K., & Owens, D. K. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-139-11-200311180-00013 · Cited by 687
Self-citationOst, D., Fein, A. M., & Feinsilver, S. H. (2003) · New England Journal of Medicine · doi:10.1056/nejmcp012290 · Cited by 680
Progress and Promise of FDG-PET Imaging for Cancer Patient Management and Oncologic Drug Development
Kelloff, G. J., Hoffman, J. M., Johnson, B., Scher, H. I., Siegel, B. A., Cheng, E. Y., Cheson, B. D., O'Shaughnessy, J., Guyton, K. Z., Mankoff, D. A., et al. (2005) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-2626 · Cited by 671
CT Screening for Lung Cancer: Five-year Prospective Experience
Swensen, S. J., Jett, J. R., Hartman, T. E., Midthun, D. E., Mandrekar, S. J., Hillman, S. L., Sykes, A.-M., Aughenbaugh, G. L., Bungum, A. O., & Allen, K. L. (2005) · Radiology · doi:10.1148/radiol.2351041662 · Cited by 636
Evidence of bias and variation in diagnostic accuracy studies
Rutjes, A. W. S., Reitsma, J. B., Di Nisio, M., Smidt, N., van Rijn, J. C., & Bossuyt, P. M. M. (2006) · Canadian Medical Association Journal · doi:10.1503/cmaj.050090 · Cited by 611
Detection of Lung Cancer by Sensor Array Analyses of Exhaled Breath
Machado, R. F., Laskowski, D., Deffenderfer, O., Burch, T., Zheng, S., Mazzone, P. J., Mekhail, T., Jennings, C., Stoller, J. K., Pyle, J., et al. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200409-1184oc · Cited by 602
Whole-Body Dual-Modality PET/CT and Whole-Body MRI for Tumor Staging in Oncology
Antoch, G. (2003) · JAMA · doi:10.1001/jama.290.24.3199 · Cited by 551
Non–Small Cell Lung Cancer: Dual-Modality PET/CT in Preoperative Staging
Antoch, G., Stattaus, J., Nemat, A. T., Marnitz, S., Beyer, T., Kuehl, H., Bockisch, A., Debatin, J. F., & Freudenberg, L. S. (2003) · Radiology · doi:10.1148/radiol.2292021598 · Cited by 540
Variation of a test’s sensitivity and specificity with disease prevalence
Leeflang, M. M. G., Rutjes, A. W. S., Reitsma, J. B., Hooft, L., & Bossuyt, P. M. M. (2013) · Canadian Medical Association Journal · doi:10.1503/cmaj.121286 · Cited by 530
Berghmans, T., Dusart, M., Paesmans, M., Hossein-Foucher, C., Buvat, I., Castaigne, C., Scherpereel, A., Mascaux, C., Moreau, M., Roelandts, M., et al. (2008) · Journal of Thoracic Oncology · doi:10.1097/jto.0b013e31815e6d6b · Cited by 524
Evaluation of Patients With Pulmonary Nodules: When Is It Lung Cancer?
Gould, M. K., Fletcher, J., Iannettoni, M. D., Lynch, W. R., Midthun, D. E., Naidich, D. P., & Ost, D. E. (2007) · Chest · doi:10.1378/chest.07-1353 · Cited by 503
Self-citationPastorino, U., Bellomi, M., Landoni, C., De Fiori, E., Arnaldi, P., Picchio, M., Pelosi, G., Boyle, P., & Fazio, F. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14188-8 · Cited by 452
Gould, M. K., Ananth, L., & Barnett, P. G. (2007) · Chest · doi:10.1378/chest.06-1261 · Cited by 439
Self-citationInitial Diagnosis of Lung Cancer
Rivera, M. P., & Mehta, A. C. (2007) · Chest · doi:10.1378/chest.07-1357 · Cited by 422
Clinical Role of FDG PET in Evaluation of Cancer Patients
Kostakoglu, L., Agress, H., & Goldsmith, S. J. (2003) · RadioGraphics · doi:10.1148/rg.232025705 · Cited by 402
Blodgett, T. M., Meltzer, C. C., & Townsend, D. W. (2007) · Radiology · doi:10.1148/radiol.2422051113 · Cited by 387
Clinical Prediction Model To Characterize Pulmonary Nodules
Herder, G. J., van Tinteren, H., Golding, R. P., Kostense, P. J., Comans, E. F., Smit, E. F., & Hoekstra, O. S. (2005) · Chest · doi:10.1378/chest.128.4.2490 · Cited by 387
Nomori, H., Watanabe, K., Ohtsuka, T., Naruke, T., Suemasu, K., & Uno, K. (2004) · Lung Cancer · doi:10.1016/j.lungcan.2004.01.009 · Cited by 344
Positron Emission Tomography (PET) in Oncology
Gallamini, A., Zwarthoed, C., & Borra, A. (2014) · Cancers · doi:10.3390/cancers6041821 · Cited by 312
European Code Against Cancer and scientific justification: third version (2003)
Boyle, P., Autier, P., Bartelink, H., Baselga, J., Boffetta, P., Burn, J., Burns, H. J. G., Christensen, L., Denis, L., Dicato, M., et al. (2003) · Annals of Oncology · doi:10.1093/annonc/mdg305 · Cited by 308
Giesel, F. L., Adeberg, S., Syed, M., Lindner, T., Jiménez-Franco, L. D., Mavriopoulou, E., Staudinger, F., Tonndorf-Martini, E., Regnery, S., Rieken, S., et al. (2021) · Journal of Nuclear Medicine · doi:10.2967/jnumed.120.245084 · Cited by 302
Ng, B., Chu, A., & Khan, M. M. (2013) · BMJ Open · doi:10.1136/bmjopen-2012-002468 · Cited by 301
Reed, C. E., Harpole, D. H., Posther, K. E., Woolson, S. L., Downey, R. J., Meyers, B. F., Heelan, R. T., MacApinlac, H. A., Jung, S.-H., Silvestri, G. A., et al. (2003) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2003.07.030 · Cited by 300
[18F]FLT-PET in oncology: current status and opportunities
Been, L. B., Suurmeijer, A. J. H., Cobben, D. C. P., Jager, P. L., Hoekstra, H. J., & Elsinga, P. H. (2004) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-004-1687-6 · Cited by 284
Decision Making in Patients with Pulmonary Nodules
Ost, D. E., & Gould, M. K. (2012) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201104-0679ci · Cited by 244
Self-citationIsasi, C. R., Lu, P., & Blaufox, M. D. (2005) · Cancer · doi:10.1002/cncr.21253 · Cited by 208
Mori, T., Nomori, H., Ikeda, K., Kawanaka, K., Shiraishi, S., Katahira, K., & Yamashita, Y. (2008) · Journal of Thoracic Oncology · doi:10.1097/jto.0b013e318168d9ed · Cited by 188
Workman, R. B., & Coleman, R. E. (2006) · PET/CT · doi:10.1007/978-0-387-38335-4_3 · Cited by 176
Cost-Effectiveness of Alternative Management Strategies for Patients with Solitary Pulmonary Nodules
Gould, M. K., Sanders, G. D., Barnett, P. G., Rydzak, C. E., Maclean, C. C., McClellan, M. B., & Owens, D. K. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-9-200305060-00009 · Cited by 172
Self-citationYap, C. S., Czernin, J., Fishbein, M. C., Cameron, R. B., Schiepers, C., Phelps, M. E., & Weber, W. A. (2006) · Chest · doi:10.1378/chest.129.2.393 · Cited by 166
(2005) · PubMed · Cited by 156
Teoh, E. J., McGowan, D. R., Bradley, K. M., Belcher, E., Black, E., & Gleeson, F. V. (2016) · European Radiology · doi:10.1007/s00330-015-3832-y · Cited by 109
Kurita, Y., Ichikawa, Y., Nakanishi, T., Tomita, Y., Hasegawa, D., Murashima, S., Hirano, T., & Sakuma, H. (2020) · Annals of Nuclear Medicine · doi:10.1007/s12149-020-01446-x · Cited by 29
Fin, L., Bailly, P., Daouk, J., & Meyer, M. (2009) · Medical Physics · doi:10.1118/1.3152116 · Cited by 18
Metadata
- Authors
- Gould, M. K., Maclean, C. C., Kuschner, W. G., Rydzak, C. E., & Owens, D. K.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2001-02-21
- Volume
- 285
- Issue
- 7
- Pages
- 914
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2094129713
- Cited by
- 1,094
- References
- 49
- FWCI
- 40.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.