High-Throughput Precision Phenotyping of Left Ventricular Hypertrophy With Cardiovascular Deep Learning
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
IMPORTANCE: Early detection and characterization of increased left ventricular (LV) wall thickness can markedly impact patient care but is limited by under-recognition of hypertrophy, measurement error and variability, and difficulty differentiating causes of increased wall thickness, such as hypertrophy, cardiomyopathy, and cardiac amyloidosis. OBJECTIVE: To assess the accuracy of a deep learning workflow in quantifying ventricular hypertrophy and predicting the cause of increased LV wall thickness. DESIGN, SETTINGS, AND PARTICIPANTS: This cohort study included physician-curated cohorts from the Stanford Amyloid Center and Cedars-Sinai Medical Center (CSMC) Advanced Heart Disease Clinic for cardiac amyloidosis and the Stanford Center for Inherited Cardiovascular Disease and the CSMC Hypertrophic Cardiomyopathy Clinic for hypertrophic cardiomyopathy from January 1, 2008, to December 31, 2020. The deep learning algorithm was trained and tested on retrospectively obtained independent echocardiogram videos from Stanford Healthcare, CSMC, and the Unity Imaging Collaborative. MAIN OUTCOMES AND MEASURES: The main outcome was the accuracy of the deep learning algorithm in measuring left ventricular dimensions and identifying patients with increased LV wall thickness diagnosed with hypertrophic cardiomyopathy and cardiac amyloidosis. RESULTS: The study included 23 745 patients: 12 001 from Stanford Health Care (6509 [54.2%] female; mean [SD] age, 61.6 [17.4] years) and 1309 from CSMC (808 [61.7%] female; mean [SD] age, 62.8 [17.2] years) with parasternal long-axis videos and 8084 from Stanford Health Care (4201 [54.0%] female; mean [SD] age, 69.1 [16.8] years) and 2351 from CSMS (6509 [54.2%] female; mean [SD] age, 69.6 [14.7] years) with apical 4-chamber videos. The deep learning algorithm accurately measured intraventricular wall thickness (mean absolute error [MAE], 1.2 mm; 95% CI, 1.1-1.3 mm), LV diameter (MAE, 2.4 mm; 95% CI, 2.2-2.6 mm), and posterior wall thickness (MAE, 1.4 mm; 95% CI, 1.2-1.5 mm) and classified cardiac amyloidosis (area under the curve [AUC], 0.83) and hypertrophic cardiomyopathy (AUC, 0.98) separately from other causes of LV hypertrophy. In external data sets from independent domestic and international health care systems, the deep learning algorithm accurately quantified ventricular parameters (domestic: R2, 0.96; international: R2, 0.90). For the domestic data set, the MAE was 1.7 mm (95% CI, 1.6-1.8 mm) for intraventricular septum thickness, 3.8 mm (95% CI, 3.5-4.0 mm) for LV internal dimension, and 1.8 mm (95% CI, 1.7-2.0 mm) for LV posterior wall thickness. For the international data set, the MAE was 1.7 mm (95% CI, 1.5-2.0 mm) for intraventricular septum thickness, 2.9 mm (95% CI, 2.4-3.3 mm) for LV internal dimension, and 2.3 mm (95% CI, 1.9-2.7 mm) for LV posterior wall thickness. The deep learning algorithm accurately detected cardiac amyloidosis (AUC, 0.79) and hypertrophic cardiomyopathy (AUC, 0.89) in the domestic external validation site. CONCLUSIONS AND RELEVANCE: In this cohort study, the deep learning model accurately identified subtle changes in LV wall geometric measurements and the causes of hypertrophy. Unlike with human experts, the deep learning workflow is fully automated, allowing for reproducible, precise measurements, and may provide a foundation for precision diagnosis of cardiac hypertrophy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2014 ESC Guidelines on diagnosis and management of hypertrophic cardiomyopathy
Authors/Task Force members, Elliott, P. M., Anastasakis, A., Borger, M. A., Borggrefe, M., Cecchi, F., Charron, P., Hagege, A. A., Lafont, A., Limongelli, G., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu284 · Cited by 4,332
A Closer Look at Spatiotemporal Convolutions for Action Recognition
Tran, D., Wang, H., Torresani, L., Ray, J., LeCun, Y., & Paluri, M. (2017) · arXiv · doi:10.48550/arxiv.1711.11248 · Cited by 3,664
A Closer Look at Spatiotemporal Convolutions for Action Recognition
Tran, D., Wang, H., Torresani, L., Ray, J., LeCun, Y., & Paluri, M. (2018) · 2018 IEEE/CVF Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2018.00675 · Cited by 3,516
Nonbiopsy Diagnosis of Cardiac Transthyretin Amyloidosis
Gillmore, J. D., Maurer, M. S., Falk, R. H., Merlini, G., Damy, T., Dispenzieri, A., Wechalekar, A. D., Berk, J. L., Quarta, C. C., Grogan, M., et al. (2016) · Circulation · doi:10.1161/circulationaha.116.021612 · Cited by 2,081
Prediction of cardiovascular risk factors from retinal fundus photographs via deep learning
Poplin, R., Varadarajan, A. V., Blumer, K., Liu, Y., McConnell, M. V., Corrado, G. S., Peng, L., & Webster, D. R. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0195-0 · Cited by 1,865
Dataset Shift in Machine Learning
(2008) · doi:10.7551/mitpress/9780262170055.001.0001 · Cited by 1,553
Phenomapping for Novel Classification of Heart Failure With Preserved Ejection Fraction
Shah, S. J., Katz, D. H., Selvaraj, S., Burke, M. A., Yancy, C. W., Gheorghiade, M., Bonow, R. O., Huang, C.-C., & Deo, R. C. (2015) · Circulation · doi:10.1161/circulationaha.114.010637 · Cited by 1,157
Video-based AI for beat-to-beat assessment of cardiac function
Ouyang, D., He, B., Ghorbani, A., Yuan, N., Ebinger, J., Langlotz, C. P., Heidenreich, P. A., Harrington, R. A., Liang, D. H., Ashley, E. A., et al. (2020) · Nature · doi:10.1038/s41586-020-2145-8 · Cited by 1,153
Self-citationZhang, J., Gajjala, S., Agrawal, P., Tison, G. H., Hallock, L. A., Beussink-Nelson, L., Lassen, M. H., Fan, E., Aras, M. A., Jordan, C., et al. (2018) · Circulation · doi:10.1161/circulationaha.118.034338 · Cited by 1,006
A decade’s perspective on DNA sequencing technology
Mardis, E. R. (2011) · Nature · doi:10.1038/nature09796 · Cited by 916
Castaño, A., Narotsky, D. L., Hamid, N., Khalique, O. K., Morgenstern, R., DeLuca, A., Rubin, J., Chiuzan, C., Nazif, T., Vahl, T., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx350 · Cited by 726
Head-to-Head Comparison of Global Longitudinal Strain Measurements among Nine Different Vendors
Farsalinos, K. E., Daraban, A. M., Ünlü, S., Thomas, J. D., Badano, L. P., & Voigt, J.-U. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2015.06.011 · Cited by 698
Tanskanen, M., Peuralinna, T., Polvikoski, T., Notkola, I., Sulkava, R., Hardy, J., Singleton, A., Kiuru‐Enari, S., Paetau, A., Tienari, P. J., et al. (2008) · Annals of Medicine · doi:10.1080/07853890701842988 · Cited by 591
Deep learning interpretation of echocardiograms
Ghorbani, A., Ouyang, D., Abid, A., He, B., Chen, J. H., Harrington, R. A., Liang, D. H., Ashley, E. A., & Zou, J. Y. (2020) · npj Digital Medicine · doi:10.1038/s41746-019-0216-8 · Cited by 518
Self-citationACCF/ASE/AHA/ASNC/HFSA/HRS/SCAI/SCCM/SCCT/SCMR 2011 Appropriate Use Criteria for Echocardiography
(2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.12.008 · Cited by 515
Wu, E., Wu, K., Daneshjou, R., Ouyang, D., Ho, D. E., & Zou, J. (2021) · Nature Medicine · doi:10.1038/s41591-021-01312-x · Cited by 494
Self-citationShah, S. J., Borlaug, B. A., Kitzman, D. W., McCulloch, A. D., Blaxall, B. C., Agarwal, R., Chirinos, J. A., Collins, S., Deo, R. C., Gladwin, M. T., et al. (2020) · Circulation · doi:10.1161/circulationaha.119.041886 · Cited by 436
Prediction of mortality from 12-lead electrocardiogram voltage data using a deep neural network
Raghunath, S., Ulloa Cerna, A. E., Jing, L., vanMaanen, D. P., Stough, J., Hartzel, D. N., Leader, J. B., Kirchner, H. L., Stumpe, M. C., Hafez, A., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0870-z · Cited by 314
Pagourelias, E. D., Mirea, O., Duchenne, J., Van Cleemput, J., Delforge, M., Bogaert, J., Kuznetsova, T., & Voigt, J.-U. (2017) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.116.005588 · Cited by 306
Goto, S., Mahara, K., Beussink-Nelson, L., Ikura, H., Katsumata, Y., Endo, J., Gaggin, H. K., Shah, S. J., Itabashi, Y., MacRae, C. A., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-22877-8 · Cited by 245
Vasan, R. S., Glazer, N. L., Felix, J. F., Lieb, W., Wild, P. S., Felix, S. B., Watzinger, N., Larson, M. G., Smith, N. L., Dehghan, A., et al. (2009) · JAMA · doi:10.1001/jama.2009.978-a · Cited by 223
Leibundgut, G., Rohner, A., Grize, L., Bernheim, A., Kessel-Schaefer, A., Bremerich, J., Zellweger, M., Buser, P., & Handke, M. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2009.11.016 · Cited by 215
(1996) · New England Journal of Medicine · doi:10.1056/nejm199610033351417 · Cited by 213
Kupari, M., Hautanen, A., Lankinen, L., Koskinen, P., Virolainen, J., Nikkila, H., & White, P. C. (1998) · Circulation · doi:10.1161/01.cir.97.6.569 · Cited by 211
Semantic Segmentation with Extended DeepLabv3 Architecture
Yurtkulu, S. C., Şahin, Y. H., & Unal, G. (2019) · 2019 27th Signal Processing and Communications Applications Conference (SIU) · doi:10.1109/siu.2019.8806244 · Cited by 189
Lindpaintner, K., Lee, M., Larson, M. G., Rao, V. S., Pfeffer, M. A., Ordovas, J. M., Schaefer, E. J., Wilson, A. F., Wilson, P. W. F., Vasan, R. S., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199604183341604 · Cited by 180
Augusto, J. B., Davies, R. H., Bhuva, A., Knott, K. D., Seraphim, A., Alfarih, M., Lau, C. W. Z., Hughes, R. K., Lopes, L. R., Shiwani, H., et al. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30267-3 · Cited by 133
Wild, P. S., Felix, J. F., Schillert, A., Teumer, A., Chen, M.-H., Leening, M. J. G., Völker, U., Großmann, V., Brody, J. A., Irvin, M. R., et al. (2017) · Journal of Clinical Investigation · doi:10.1172/jci84840 · Cited by 129
Self-citationHuda, A., Castaño, A., Niyogi, A., Schumacher, J., Stewart, M., Bruno, M., Hu, M., Ahmad, F. S., Deo, R. C., & Shah, S. J. (2021) · Nature Communications · doi:10.1038/s41467-021-22876-9 · Cited by 114
Howard, J. P., Stowell, C. C., Cole, G. D., Ananthan, K., Demetrescu, C. D., Pearce, K., Rajani, R., Sehmi, J., Vimalesvaran, K., Kanaganayagam, G. S., et al. (2021) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.120.011951 · Cited by 58
Self-citationPhelan, D. M. J., Sperry, B. W., Thavendiranathan, P., Collier, P. H., Popović, Z., Lever, H. M., Smedira, N. G., & Desai, M. Y. (2017) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2017.02.009 · Cited by 28
Gómez-Angelats, E., Sierra, À., Enjuto, M., et al. (2000) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000941 · Cited by 21
Beslagic, E. K., & Damianova, A. J. (2014) · Cited by 14
Ranking the risk of heart disease
Eisenstein, M. S. (2021) · Nature · doi:10.1038/d41586-021-01452-7 · Cited by 3
Cited by
Transforming Cardiovascular Care With Artificial Intelligence: From Discovery to Practice
Khera, R., Oikonomou, E. K., Nadkarni, G. N., Morley, J. R., Wiens, J., Butte, A. J., & Topol, E. J. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2024.05.003 · Cited by 264
Blinded, randomized trial of sonographer versus AI cardiac function assessment
He, B., Kwan, A. C., Cho, J. H., Yuan, N., Pollick, C., Shiota, T., Ebinger, J., Bello, N. A., Wei, J., Josan, K., et al. (2023) · Nature · doi:10.1038/s41586-023-05947-3 · Cited by 256
Self-citationThe Integration of Artificial Intelligence into Clinical Practice
Karalis, V. D. (2024) · Applied Biosciences · doi:10.3390/applbiosci3010002 · Cited by 255
“In imaging, AI is utilized to automatically evaluate the thickness and properties of the myocardium to distinguish between different types of cardiomy-opathies [39,40].”
BackgroundMethodVision–language foundation model for echocardiogram interpretation
Christensen, M., Vukadinovic, M., Yuan, N., & Ouyang, D. (2024) · Nature Medicine · doi:10.1038/s41591-024-02959-y · Cited by 231
Self-citationSchepart, A., Burton, A., Durkin, L., Fuller, A., Charap, E., Bhambri, R., & Ahmad, F. S. (2023) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2023.04.003 · Cited by 40
“Cardiologists and IT administrators identified several potential opportunities for using AI in cardiovascular care, including (1) faster diagnosis of rare or commonly missed conditions; (2) faster and more reliable risk stratification; (3) rapid data integration of diverse, longitudinal data with clinical decision ale…”
Background
Metadata
- Authors
- Duffy, G., Cheng, P. P., Yuan, N., He, B., Kwan, A. C., Shun-Shin, M. J., Alexander, K. M., Ebinger, J., Lungren, M. P., Rader, F., Liang, D. H., Schnittger, I., Ashley, E. A., Zou, J. Y., Patel, J., Witteles, R., Cheng, S., & Ouyang, D.
- Venue
- JAMA Cardiology
- Publisher
- American Medical Association (AMA)
- Published
- 2022-04-01
- Volume
- 7
- Issue
- 4
- Pages
- 386
- ISSN
- 2380-6583 (ISSN-L)
- OpenAlex
- W3174416962
- Cited by
- 236
- References
- 34
- FWCI
- 9.79
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.