The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Highly Ordered Platinum‐Nanotubule Arrays for Amperometric Glucose Sensing
Abstract
Direct glucose sensing on highly ordered platinum‐nanotubule array electrodes (NTAEs) is systematically investigated. The NTAEs are fabricated by electrochemical deposition of platinum in a 3‐aminopropyltrimethoxysilane‐modified anodic alumina membrane. Their structures and morphologies are then characterized using X‐ray diffraction and scanning electron microscopy, respectively. Electrochemical results show that NTAEs with different real surface areas could be achieved by controlling the deposition time or by using anodic alumina membranes with different pore size. Electrochemical responses of the as‐synthesized NTAEs to glucose in a solutions of either 0.5 M H 2 SO 4, or phosphate‐buffered saline (PBS, pH 7.4) containing 0.1 M KCl are discussed. Based on the different electrochemical reaction mechanisms of glucose and interferents such as p‐acetamedophenol and ascorbic acid, their high roughness factor makes NTAEs sensitive, selective, and stable enough to be a kind of biosensor for the non‐enzymatic detection of glucose. Such a glucose sensor allows the determination of glucose in the linear range 2–14 mM, with a sensitivity of 0.1 μA cm–2 mM–1 (correlation coefficient 0.999), and a detection limit of 1.0 μM glucose, with neglectable interference from physiological levels of 0.1 mM p‐acetamedophenol, 0.1 mM ascorbic acid, and 0.02 mM uric acid.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanomaterials: A Membrane-Based Synthetic Approach
Martin, C. R. (1994) · Science · doi:10.1126/science.266.5193.1961 · Cited by 4,060
Structural Features of Oxide Coatings on Aluminum
Keller, F., Hunter, M. S., & Robinson, D. L. (1953) · Journal of The Electrochemical Society · doi:10.1149/1.2781142 · Cited by 1,367
Fabrication and Magnetic Properties of Arrays of Metallic Nanowires
Whitney, T. M., Searson, P. C., Jiang, J. S., & Chien, C. L. (1993) · Science · doi:10.1126/science.261.5126.1316 · Cited by 1,207
Anodic oxide films on aluminum
Diggle, J. W., Downie, T. C., & Goulding, C. W. (1969) · Chemical Reviews · doi:10.1021/cr60259a005 · Cited by 1,200
Real surface area measurements in electrochemistry
Trasatti, S., & Petrii, O. A. (1992) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(92)80162-w · Cited by 1,130
Template Synthesis of Electronically Conductive Polymer Nanostructures
Martin, C. R. (1995) · Accounts of Chemical Research · doi:10.1021/ar00050a002 · Cited by 924
Nonenzymatic Glucose Detection Using Mesoporous Platinum
Park, S., Chung, T. D., & Kim, H. C. (2003) · Analytical Chemistry · doi:10.1021/ac0263465 · Cited by 594
Kinetics and mechanism of glucose electrooxidation on different electrode-catalysts
Vassilyev, Y. B., Khazova, O. A., & Nikolaeva, N. N. (1985) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/0022-0728(85)85084-1 · Cited by 422
Shoji, E., & Freund, M. S. (2001) · Journal of the American Chemical Society · doi:10.1021/ja005906j · Cited by 343
Synthesis of polymeric microcapsule arrays and their use for enzyme immobilization
Parthasarathy, R. V., & Martin, C. R. (1994) · Nature · doi:10.1038/369298a0 · Cited by 326
Cited by
Platinum-Based Nanostructured Materials: Synthesis, Properties, and Applications
Chen, A., & Holt-Hindle, P. (2010) · Chemical Reviews · doi:10.1021/cr9003902 · Cited by 1,390
Peng, Z., & Yang, H. (2009) · Nano Today · doi:10.1016/j.nantod.2008.10.010 · Cited by 1,085
Electrochemical Non-enzymatic Glucose Sensors: A Perspective and an Evaluation
Toghill, K. E., & Compton, R. G. (2010) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15359-4 · Cited by 926
Recent advances in electrochemical glucose biosensors: a review
Chen, C., Xie, Q., Yang, D., Xiao, H., Fu, Y., Tan, Y., & Yao, S. (2013) · RSC Advances · doi:10.1039/c2ra22351a · Cited by 807
Jiang, L.-C., & Zhang, W.-D. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.10.038 · Cited by 667
Chemical sensors based on nanostructured materials
Huang, X.-J., & Choi, Y.-K. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.06.022 · Cited by 662
Nonenzymatic Electrochemical Glucose Sensor Based on Nanoporous PtPb Networks
Wang, J., Thomas, D. F., & Chen, A. (2008) · Analytical Chemistry · doi:10.1021/ac701790z · Cited by 534
Non-enzymatic electrochemical sensing of glucose
Wang, G., He, X., Wang, L., Gu, A., Huang, Y., Fang, B., Geng, B., & Zhang, X. (2013) · Microchimica Acta · doi:10.1007/s00604-012-0923-1 · Cited by 522
Li, Y., Song, Y.-Y., Yang, C., & Xia, X.-H. (2007) · Electrochemistry Communications · doi:10.1016/j.elecom.2006.11.035 · Cited by 515
Self-citationXu, C. W., Wang, H., Shen, P. K., & Jiang, S. P. (2007) · Advanced Materials · doi:10.1002/adma.200602911 · Cited by 494
An improved sensitivity non-enzymatic glucose sensor based on a CuO nanowire modified Cu electrode
Zhuang, Z., Su, X., Yuan, H., Sun, Q., Xiao, D., & Choi, M. M. F. (2008) · The Analyst · doi:10.1039/b712970j · Cited by 481
Electrochemical non-enzymatic glucose sensors: recent progress and perspectives
Wei, M., Qiao, Y., Zhao, H., Liang, J., Li, T., Luo, Y., Lu, S., Shi, X., Lu, W., & Sun, X. (2020) · Chemical Communications · doi:10.1039/d0cc05650b · Cited by 467
Niu, X., Lan, M., Zhao, H., & Chen, C. (2013) · Analytical Chemistry · doi:10.1021/ac3030976 · Cited by 412
Meng, L., Jin, J., Yang, G., Lu, T., Zhang, H., & Cai, C. (2009) · Analytical Chemistry · doi:10.1021/ac901005p · Cited by 412
Liu, Y., Teng, H., Hou, H., & You, T. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.04.032 · Cited by 391
Gao, H., Xiao, F., Ching, C. B., & Duan, H. (2011) · ACS Applied Materials & Interfaces · doi:10.1021/am200563f · Cited by 383
Emerging synergy between nanotechnology and implantable biosensors: A review
Vaddiraju, S., Tomazos, I., Burgess, D. J., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.001 · Cited by 368
Nanomaterials for electrochemical non-enzymatic glucose biosensors
Si, P., Huang, Y., Wang, T., & Ma, J. (2013) · RSC Advances · doi:10.1039/c2ra22360k · Cited by 364
Superhydrophobicity of 3D Porous Copper Films Prepared Using the Hydrogen Bubble Dynamic Template
Li, Y., Jia, W.-Z., Song, Y.-Y., & Xia, X.-H. (2007) · Chemistry of Materials · doi:10.1021/cm071738j · Cited by 356
Self-citationCuO Nanospheres Based Nonenzymatic Glucose Sensor
Reitz, E., Jia, W., Gentile, M., Wang, Y., & Lei, Y. (2008) · Electroanalysis · doi:10.1002/elan.200804327 · Cited by 346
Metal oxide based non-enzymatic electrochemical sensors for glucose detection
Dong, Q., Ryu, H., & Lei, Y. (2021) · Electrochimica Acta · doi:10.1016/j.electacta.2021.137744 · Cited by 338
Ultrasensitive and selective non-enzymatic glucose detection using copper nanowires
Zhang, Y., Su, L., Manuzzi, D., de los Monteros, H. V. E., Jia, W., Huo, D., Hou, C., & Lei, Y. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.11.006 · Cited by 321
Kong, T., Chen, Y., Ye, Y., Zhang, K., Wang, Z., & Wang, X. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.01.002 · Cited by 319
Fabrication of a glucose sensor based on a novel nanocomposite electrode
Safavi, A., Maleki, N., & Farjami, E. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.08.040 · Cited by 296
Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, S., Burgess, D. J., Tomazos, I., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400632 · Cited by 285
Functionalized ceramics for biomedical, biotechnological and environmental applications
Treccani, L., Yvonne Klein, T., Meder, F., Pardun, K., & Rezwan, K. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.03.036 · Cited by 284
RONG, L., YANG, C., QIAN, Q., & XIA, X. (2007) · Talanta · doi:10.1016/j.talanta.2006.12.037 · Cited by 279
Self-citationLu, L.-M., Li, H.-B., Qu, F., Zhang, X.-B., Shen, G.-L., & Yu, R.-Q. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.01.033 · Cited by 277
Yang, J., Jiang, L.-C., Zhang, W.-D., & Gunasekaran, S. (2010) · Talanta · doi:10.1016/j.talanta.2010.03.047 · Cited by 266
Hu, Y., Zhang, H., Wu, P., Zhang, H., Zhou, B., & Cai, C. (2011) · Physical Chemistry Chemical Physics · doi:10.1039/c0cp01998d · Cited by 264
Qureshi, A., Kang, W. P., Davidson, J. L., & Gurbuz, Y. (2009) · Diamond and Related Materials · doi:10.1016/j.diamond.2009.09.008 · Cited by 261
Zou, Y., Xiang, C., Sun, L.-X., & Xu, F. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.10.009 · Cited by 260
Enzyme‐Free Amperometric Sensing of Glucose by Using Gold Nanoparticles
Jena, B. K., & Raj, C. R. (2006) · Chemistry – A European Journal · doi:10.1002/chem.200501051 · Cited by 259
Singh, B., & Dempsey, E. (2012) · ECS Journal of Solid State Science and Technology · doi:10.1149/2.003203jss · Cited by 7
Metadata
- Authors
- Yuan, J. H., Wang, K., & Xia, X. H.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2005-04-26
- Volume
- 15
- Issue
- 5
- Pages
- 803-809
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2134313088
- Cited by
- 432
- References
- 21
- FWCI
- 15.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.