The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Soft Actuators and Robots that Are Resistant to Mechanical Damage
Open accessAbstract
This paper characterizes the ability of soft pneumatic actuators and robots to resist mechanical insults that would irreversibly damage or destroy hard robotic systems—systems fabricated in metals and structural polymers, and actuated mechanically—of comparable sizes. The pneumatic networks that actuate these soft machines are formed by bonding two layers of elastomeric or polymeric materials that have different moduli on application of strain by pneumatic inflation; this difference in strain between an extensible top layer and an inextensible, strain‐limiting, bottom layer causes the pneumatic network to expand anisotropically. While all the soft machines described here are, to some extent, more resistant to damage by compressive forces, blunt impacts, and severe bending than most corresponding hard systems, the composition of the strain‐limiting layers confers on them very different tensile and compressive strengths.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Xia, Y., & Whitesides, G. M. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.153 · Cited by 4,611
Self-citationHigh-Speed Electrically Actuated Elastomers with Strain Greater Than 100%
Pelrine, R., Kornbluh, R., Pei, Q., & Joseph, J. (2000) · Science · doi:10.1126/science.287.5454.836 · Cited by 3,283
Shepherd, R. F., Ilievski, F., Choi, W., Morin, S. A., Stokes, A. A., Mazzeo, A. D., Chen, X., Wang, M., & Whitesides, G. M. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1116564108 · Cited by 2,111
Self-citationStretchable, Transparent, Ionic Conductors
Keplinger, C., Sun, J.-Y., Foo, C. C., Rothemund, P., Whitesides, G. M., & Suo, Z. (2013) · Science · doi:10.1126/science.1240228 · Cited by 1,754
Self-citationUniversal robotic gripper based on the jamming of granular material
Brown, E., Rodenberg, N., Amend, J., Mozeika, A., Steltz, E., Zakin, M. R., Lipson, H., & Jaeger, H. M. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1003250107 · Cited by 1,603
Shahinpoor, M., Bar-Cohen, Y., Simpson, J. O., & Smith, J. (1998) · Smart Materials and Structures · doi:10.1088/0964-1726/7/6/001 · Cited by 1,021
Modeling and control of McKibben artificial muscle robot actuators
(2000) · IEEE Control Systems · doi:10.1109/37.833638 · Cited by 924
Foundations of Materials Science and Engineering
Smith, W. F. (1993) · Cited by 906
Biomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 801
Camouflage and Display for Soft Machines
Morin, S. A., Shepherd, R. F., Kwok, S. W., Stokes, A. A., Nemiroski, A., & Whitesides, G. M. (2012) · Science · doi:10.1126/science.1222149 · Cited by 768
Self-citationRobotic Tentacles with Three‐Dimensional Mobility Based on Flexible Elastomers
Martinez, R. V., Branch, J. L., Fish, C. R., Jin, L., Shepherd, R. F., Nunes, R. M. D., Suo, Z., & Whitesides, G. M. (2013) · Advanced Materials · doi:10.1002/adma.201203002 · Cited by 718
Self-citationGoQBot: a caterpillar-inspired soft-bodied rolling robot
Lin, H.-T., Leisk, G. G., & Trimmer, B. (2011) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/6/2/026007 · Cited by 690
Ilievski, F., Mazzeo, A. D., Shepherd, R. F., Chen, X., & Whitesides, G. M. (2011) · Angewandte Chemie · doi:10.1002/ange.201006464 · Cited by 665
Self-citationElastomeric Origami: Programmable Paper‐Elastomer Composites as Pneumatic Actuators
Martinez, R. V., Fish, C. R., Chen, X., & Whitesides, G. M. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201102978 · Cited by 651
Self-citationLarge-scale failure modes of dielectric elastomer actuators
Plante, J.-S., & Dubowsky, S. (2006) · International Journal of Solids and Structures · doi:10.1016/j.ijsolstr.2006.03.026 · Cited by 618
Stretching Dielectric Elastomer Performance
Carpi, F., Bauer, S., & De Rossi, D. (2010) · Science · doi:10.1126/science.1194773 · Cited by 523
Albu-Schaffer, A., Eiberger, O., Grebenstein, M., Haddadin, S., Ott, C., Wimbock, T., Wolf, S., & Hirzinger, G. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927979 · Cited by 506
Keplinger, C., Li, T., Baumgartner, R., Suo, Z., & Bauer, S. (2012) · Soft Matter · doi:10.1039/c1sm06736b · Cited by 435
Self-citationMechanical properties of silicones for MEMS
Schneider, F., Fellner, T., Wilde, J., & Wallrabe, U. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/6/065008 · Cited by 435
Using Explosions to Power a Soft Robot
Shepherd, R. F., Stokes, A. A., Freake, J., Barber, J., Snyder, P. W., Mazzeo, A. D., Cademartiri, L., Morin, S. A., & Whitesides, G. M. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201209540 · Cited by 332
Self-citationBone Strength in Small Mammals and Bipedal Birds: Do Safety Factors Change With Body Size?
Biewener, A. A. (1982) · Journal of Experimental Biology · doi:10.1242/jeb.98.1.289 · Cited by 269
Mechanical and Electrical Responses of the Squid Giant Axon to Simple Elongation
Galbraith, J. A., Thibault, L. E., & Matteson, D. R. (1993) · Journal of Biomechanical Engineering · doi:10.1115/1.2895464 · Cited by 243
Röntgen’s electrode-free elastomer actuators without electromechanical pull-in instability
Keplinger, C., Kaltenbrunner, M., Arnold, N., & Bauer, S. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0913461107 · Cited by 232
Self-citationSoft Machines That are Resistant to Puncture and That Self Seal
Shepherd, R. F., Stokes, A. A., Nunes, R. M. D., & Whitesides, G. M. (2013) · Advanced Materials · doi:10.1002/adma.201303175 · Cited by 196
Self-citationThe DLR MIRO: a versatile lightweight robot for surgical applications
Hagn, U., Nickl, M., Jörg, S., Passig, G., Bahls, T., Nothhelfer, A., Hacker, F., Le‐Tien, L., Albu‐Schäffer, A., Konietschke, R., et al. (2008) · Industrial Robot: An International Journal · doi:10.1108/01439910810876427 · Cited by 188
Micro artificial muscle fiber using NiTi spring for soft robotics
Kim, S., Hawkes, E. W., Cho, K., Joldaz, M., Foleyz, J., & Wood, R. J. (2009) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2009.5354178 · Cited by 155
Advances in Composite Materials - Analysis of Natural and Man-Made Materials
Těšinová, P. (2011) · InTech eBooks · doi:10.5772/728 · Cited by 153
Martin, É., L’Archevêque, R., Gemme, S., Rekleitis, I. M., & Dupuis, É. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.929926 · Cited by 98
Control of soft machines using actuators operated by a Braille display
Mosadegh, B., Mazzeo, A. D., Shepherd, R. F., Morin, S. A., Gupta, U., Sani, I. Z., Lai, D., Takayama, S., & Whitesides, G. M. (2013) · Lab on a Chip · doi:10.1039/c3lc51083b · Cited by 81
Self-citationA Kinematic Analysis of Tentacle Extension in the Squid Loligo Pealei
Kier, W. M., & LEEUWEN, J. L. V. (1997) · Journal of Experimental Biology · doi:10.1242/jeb.200.1.41 · Cited by 72
Mori, M., Suzumori, K., Takahashi, M., & Hosoya, T. (2010) · Advanced Robotics · doi:10.1163/016918609x12586209967366 · Cited by 62
Mechatronics, robotics and components for automation and control
Ollero, A., Boverie, S., Goodall, R. M., Sąsiadek, J. Z., Erbe, H.-H., & Zuehlke, D. (2006) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2006.02.002 · Cited by 45
Hošovský, A., & Havran, M. (2012) · Cited by 42
The Direct Effects of Graded Axonal Compression on Axoplasm and Fast Axoplasmic Transport
Gallant, P. E. (1992) · Journal of Neuropathology & Experimental Neurology · doi:10.1097/00005072-199203000-00011 · Cited by 37
Marchese, A. D., Onal, C. D., & Rus, D. L. (2013) · Springer tracts in advanced robotics · doi:10.1007/978-3-319-00065-7_4 · Cited by 31
Cited by
Self-healing soft pneumatic robots
Terryn, S., Brancart, J., Lefeber, D., Van Assche, G., & Vanderborght, B. (2017) · Science Robotics · doi:10.1126/scirobotics.aan4268 · Cited by 537
50th Anniversary Perspective: Networks and Gels: Soft but Dynamic and Tough
Creton, C. (2017) · Macromolecules · doi:10.1021/acs.macromol.7b01698 · Cited by 463
Elastic Inflatable Actuators for Soft Robotic Applications
Gorissen, B., Reynaerts, D., Konishi, S., Yoshida, K., Kim, J., & De Volder, M. (2017) · Advanced Materials · doi:10.1002/adma.201604977 · Cited by 462
3D printing for soft robotics – a review
Gul, J. Z., Sajid, M., Rehman, M. M., Siddiqui, G. U., Shah, I., Kim, K.-H., Lee, J.-W., & Choi, K. H. (2018) · Science and Technology of Advanced Materials · doi:10.1080/14686996.2018.1431862 · Cited by 428
Xavier, M. S., Tawk, C. D., Zolfagharian, A., Pinskier, J., Howard, D., Young, T., Lai, J., Harrison, S. M., Yong, Y. K., Bodaghi, M., et al. (2022) · IEEE Access · doi:10.1109/access.2022.3179589 · Cited by 418
Metadata
- Authors
- Martinez, R. V., Glavan, A. C., Keplinger, C., Oyetibo, A. I., & Whitesides, G. M.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2014-02
- Volume
- 24
- Issue
- 20
- Pages
- 3003-3010
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2047184956
- Cited by
- 261
- References
- 35
- FWCI
- 10.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.