Alignment‐Free Liquid‐Capsule Pressure Sensor for Cardiovascular Monitoring
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Wearable pressure sensors enable long‐term real‐time health monitoring in a noninvasive and power‐efficient way; however, the sensors are often required to be precisely applied at the optimal measurement spot, e.g., nearby radial artery, for signal acquisition, causing inconvenience for untrained users or the elders. In this paper, a wearable liquid‐capsule sensor platform embedded with a piezo‐resistive pressure sensor is presented for continuous, accurate, and alignment‐relaxed physiological monitoring, i.e., heart rate (HR) and blood pressure (BP) tracking. The flexible capsule design ensures comfort and good device conformation to any skin regions. For HR and BP measurements, experiments are performed on 12 human subjects. The results show that the capsuled sensor can continuously track: 1) HR with a mean absolute difference (MAD) of 0.88 beats per minute (bpm) and 2) BP with a MAD<3 mmHg for both diastolic and systolic blood pressure. The new liquid‐capsule‐based sensor platform may help to realize an accurate, flexible, robust, and low‐power solution for next‐generation wearable health monitoring devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diabetes and Cardiovascular Disease: The Framingham Study
Kannel, W. B. (1979) · JAMA · doi:10.1001/jama.1979.03290450033020 · Cited by 2,936
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Schwartz, G., Tee, B. C.-K., Mei, J., Appleton, A. L., Kim, D. H., Wang, H., & Bao, Z. (2013) · Nature Communications · doi:10.1038/ncomms2832 · Cited by 2,042
Pan, L., Chortos, A., Yu, G., Wang, Y., Isaacson, S., Allen, R., Shi, Y., Dauskardt, R., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms4002 · Cited by 1,519
Stretchable silicon nanoribbon electronics for skin prosthesis
Kim, J., Lee, M., Shim, H. J., Ghaffari, R., Cho, H. R., Son, D., Jung, Y. H., Soh, M., Choi, C., Jung, S., et al. (2014) · Nature Communications · doi:10.1038/ncomms6747 · Cited by 1,435
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Wearable and Highly Sensitive Graphene Strain Sensors for Human Motion Monitoring
Wang, Y., Wang, L., Yang, T., Li, X., Zang, X., Zhu, M., Wang, K., Wu, D., & Zhu, H. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201400379 · Cited by 1,085
Park, J., Lee, Y., Hong, J., Ha, M., Jung, Y.-D., Lim, H., Kim, S. Y., & Ko, H. (2014) · ACS Nano · doi:10.1021/nn500441k · Cited by 915
Flexible and Stretchable Electronics for Biointegrated Devices
Kim, D.-H., Ghaffari, R., Lu, N., & Rogers, J. A. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150018 · Cited by 749
Wearable Microfluidic Diaphragm Pressure Sensor for Health and Tactile Touch Monitoring
Gao, Y., Ota, H., Schaler, E. W., Chen, K., Zhao, A., Gao, W., Fahad, H. M., Leng, Y., Zheng, A., Xiong, F., et al. (2017) · Advanced Materials · doi:10.1002/adma.201701985 · Cited by 614
Chen, W., Kobayashi, T., Ichikawa, S., Takeuchi, Y., & Togawa, T. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345755 · Cited by 425
Pulse Transit Time as an Indicator of Arterial Blood Pressure
Geddes, L. A., Voelz, M. H., Babbs, C. F., Bourland, J. D., & Tacker, W. A. (1981) · Psychophysiology · doi:10.1111/j.1469-8986.1981.tb01545.x · Cited by 293
Nitric oxide modulation of blood vessel tone identified by arterial waveform analysis
McVEIGH, G. E., ALLEN, P. B., MORGAN, D. R., HANRATTY, C. G., & SILKE, B. (2001) · Clinical Science · doi:10.1042/cs1000387 · Cited by 144
Cited by
Wearable Pressure Sensors for Pulse Wave Monitoring
Meng, K., Xiao, X., Wei, W., Chen, G., Nashalian, A., Shen, S., Xiao, X., & Chen, J. (2022) · Advanced Materials · doi:10.1002/adma.202109357 · Cited by 878
Emerging Technologies of Flexible Pressure Sensors: Materials, Modeling, Devices, and Manufacturing
Huang, Y., Fan, X., Chen, S., & Zhao, N. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808509 · Cited by 543
Self-citationFlexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
Self-citationPolymer nanocomposite meshes for flexible electronic devices
Gong, M., Zhang, L., & Wan, P. (2020) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2020.101279 · Cited by 270
Khoshmanesh, F., Thurgood, P., Pirogova, E., Nahavandi, S., & Baratchi, S. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112946 · Cited by 204
Metadata
- Authors
- Fan, X., Huang, Y., Ding, X., Luo, N., Li, C., Zhao, N., & Chen, S.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2018-09-19
- Volume
- 28
- Issue
- 44
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2890493040
- Cited by
- 70
- References
- 13
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.