CoChat

Alignment‐Free Liquid‐Capsule Pressure Sensor for Cardiovascular Monitoring

Fan, Xiangyu, Huang, Yan, Ding, Xiaorong, Luo, Ningqi, Li, Chenglin, Zhao, Ni, Chen, Shih‐Chi · 2018 · Advanced Functional Materials
Cited by 70

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

Wearable pressure sensors enable long‐term real‐time health monitoring in a noninvasive and power‐efficient way; however, the sensors are often required to be precisely applied at the optimal measurement spot, e.g., nearby radial artery, for signal acquisition, causing inconvenience for untrained users or the elders. In this paper, a wearable liquid‐capsule sensor platform embedded with a piezo‐resistive pressure sensor is presented for continuous, accurate, and alignment‐relaxed physiological monitoring, i.e., heart rate (HR) and blood pressure (BP) tracking. The flexible capsule design ensures comfort and good device conformation to any skin regions. For HR and BP measurements, experiments are performed on 12 human subjects. The results show that the capsuled sensor can continuously track: 1) HR with a mean absolute difference (MAD) of 0.88 beats per minute (bpm) and 2) BP with a MAD<3 mmHg for both diastolic and systolic blood pressure. The new liquid‐capsule‐based sensor platform may help to realize an accurate, flexible, robust, and low‐power solution for next‐generation wearable health monitoring devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adfm.201805045

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 70

Metadata

Authors
Fan, X., Huang, Y., Ding, X., Luo, N., Li, C., Zhao, N., & Chen, S.
Venue
Advanced Functional Materials
Publisher
Wiley
Published
2018-09-19
Volume
28
Issue
44
ISSN
  • 1616-301X (ISSN-L)
  • 1616-3028
OpenAlex
W2890493040
Cited by
70
References
13
FWCI
3.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.