Abstract
The goal of human‐on‐a‐chip systems is to capture multiorgan complexity and predict the human response to compounds within physiologically relevant platforms. The generation and characterization of such systems is currently a focal point of research given the long‐standing inadequacies of conventional techniques for predicting human outcome. Functional systems can measure and quantify key cellular mechanisms that correlate with the physiological status of a tissue, and can be used to evaluate therapeutic challenges utilizing many of the same endpoints used in animal experiments or clinical trials. Culturing multiple organ compartments in a platform creates a more physiologic environment (organ–organ communication). Here is reported a human 4‐organ system composed of heart, liver, skeletal muscle, and nervous system modules that maintains cellular viability and function over 28 days in serum‐free conditions using a pumpless system. The integration of noninvasive electrical evaluation of neurons and cardiac cells and mechanical determination of cardiac and skeletal muscle contraction allows the monitoring of cellular function, especially for chronic toxicity studies in vitro. The 28‐day period is the minimum timeframe for animal studies to evaluate repeat dose toxicity. This technology can be a relevant alternative to animal testing by monitoring multiorgan function upon long‐term chemical exposure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
WITHDRAWN—a resource for withdrawn and discontinued drugs
Siramshetty, V. B., Nickel, J., Omieczynski, C., Gohlke, B.-O., Drwal, M. N., & Preissner, R. (2016) · Nucleic Acids Research · doi:10.1093/nar/gkv1192 · Cited by 286
RetractedLessons learned from the fate of AstraZeneca's drug pipeline: a five-dimensional framework
Cook, D., Brown, D., Alexander, R., March, R., Morgan, P., Satterthwaite, G., & Pangalos, M. N. (2014) · Nature Reviews Drug Discovery · doi:10.1038/nrd4309 · Cited by 1,344
Maschmeyer, I., Lorenz, A. K., Schimek, K., Hasenberg, T., Ramme, A. P., Hübner, J., Lindner, M., Drewell, C., Bauer, S., Thomas, A., et al. (2015) · Lab on a Chip · doi:10.1039/c5lc00392j · Cited by 861
Multi-Organ toxicity demonstration in a functional human in vitro system composed of four organs
Oleaga, C., Bernabini, C., Smith, A. S. T., Srinivasan, B., Jackson, M., McLamb, W., Platt, V., Bridges, R., Cai, Y., Santhanam, N., et al. (2016) · Scientific Reports · doi:10.1038/srep20030 · Cited by 442
Self-citationMarx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
Esch, M. B., Mahler, G. J., Stokol, T., & Shuler, M. L. (2014) · Lab Chip · doi:10.1039/c4lc00371c · Cited by 281
Multi-cellular 3D human primary liver cell culture elevates metabolic activity under fluidic flow
Esch, M. B., Prot, J.-M., Wang, Y. I., Miller, P., Llamas-Vidales, J. R., Naughton, B. A., Applegate, D. R., & Shuler, M. L. (2015) · Lab on a Chip · doi:10.1039/c5lc00237k · Cited by 173
Cardiovascular organ-on-a-chip platforms for drug discovery and development
Ribas, J., Sadeghi, H., Manbachi, A., Leijten, J., Brinegar, K., Zhang, Y. S., Ferreira, L., & Khademhosseini, A. (2016) · Applied In Vitro Toxicology · doi:10.1089/aivt.2016.0002 · Cited by 161
Self-contained, low-cost Body-on-a-Chip systems for drug development
Wang, Y. I., Oleaga, C., Long, C. J., Esch, M. B., McAleer, C. W., Miller, P. G., Hickman, J. J., & Shuler, M. L. (2017) · Experimental Biology and Medicine · doi:10.1177/1535370217694101 · Cited by 59
Self-citation
Research works printed but not linked: 23
- 10.1016/j.addr.2013.12.003 · DOI · Paper page
- 10.1089/aivt.2016.0003 · DOI
- 10.1371/journal.pone.0139587 · DOI · Paper page
- 10.1002/bit.25989 · DOI · Paper page
- 10.1038/nbt.2989 · DOI · Paper page
- Marx U., 2016, ALTEX, 33, 272
- 10.1016/B978-0-12-803620-4.00005-0 · doi:10.1016/b978-0-12-803620-4.00005-0
- Materne E. M., 2015, J. Vis. Exp., 98, e52526
- 10.1038/ncomms14584 · DOI · Paper page
- 10.1016/j.biomaterials.2010.12.022 · DOI · Paper page
- 10.1016/j.biomaterials.2015.04.035 · DOI · Paper page
- 10.1021/cn300206k · DOI
- 10.1038/nprot.2007.229 · DOI
- 10.1063/1.4817939 · DOI
- 10.1371/journal.pone.0011042 · DOI · Paper page
- Oleaga C., 2017, Pharmacology and Toxicology, 229
- Smith A. S., 2014, J. Vis. Exp., 92, e51866
- 10.1016/j.biomaterials.2011.09.014 · DOI · Paper page
- 10.1039/b917763a · DOI · Paper page
- 10.1002/jbt.21469 · DOI · Paper page
- 10.14573/altex.2009.4.295 · DOI · Paper page
- 10.2133/dmpk.25.236 · DOI
- 10.1002/bit.26045 · DOI · Paper page
Cited by
Multi-organ system for the evaluation of efficacy and off-target toxicity of anticancer therapeutics
McAleer, C. W., Long, C. J., Elbrecht, D., Sasserath, T., Bridges, L. R., Rumsey, J. W., Martin, C., Schnepper, M., Wang, Y., Schuler, F., et al. (2019) · Science Translational Medicine · doi:10.1126/scitranslmed.aav1386 · Cited by 199
Self-citationRoadblocks confronting widespread dissemination and deployment of Organs on Chips
Alver, C. G., Drabbe, E., Ishahak, M., & Agarwal, A. (2024) · Nature Communications · doi:10.1038/s41467-024-48864-3 · Cited by 74
Rumsey, J. W., Lorance, C., Jackson, M., Sasserath, T., McAleer, C. W., Long, C. J., Goswami, A., Russo, M. A., Raja, S. M., Gable, K. L., et al. (2022) · Advanced Therapeutics · doi:10.1002/adtp.202200030 · Cited by 74
Self-citationSoucy, J. R., Bindas, A. J., Koppes, A. N., & Koppes, R. A. (2019) · iScience · doi:10.1016/j.isci.2019.10.052 · Cited by 62
Liver–heart on chip models for drug safety
Ferrari, E., & Rasponi, M. (2021) · APL Bioengineering · doi:10.1063/5.0048986 · Cited by 53
Metadata
- Authors
- Oleaga, C., Lavado, A., Riu, A., Rothemund, S., Carmona‐Moran, C. A., Persaud, K., Yurko, A., Lear, J., Narasimhan, N. S., Long, C. J., Sommerhage, F., Bridges, L. R., Cai, Y., Martin, C., Schnepper, M. T., Goswami, A., Note, R., Langer, J., Teissier, S., Cotovio, J., & Hickman, J. J.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2018-12-14
- Volume
- 29
- Issue
- 8
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2905380016
- Cited by
- 63
- References
- 9
- FWCI
- 2.83
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Long‐Term Electrical and Mechanical Function Monitoring of a Human‐on‐a‐Chip System. https://app.cochat.ai/papers/10.1002/adfm.201805792
- The paper
- Oleaga, C., Lavado, A., Riu, A., Rothemund, S., Carmona‐Moran, C. A., Persaud, K., Yurko, A., Lear, J., Narasimhan, N. S., Long, C. J., Sommerhage, F., Bridges, L. R., Cai, Y., Martin, C., Schnepper, M. T., Goswami, A., Note, R., Langer, J., Teissier, S., . . . Hickman, J. J. (2019). Long‐Term Electrical and Mechanical Function Monitoring of a Human‐on‐a‐Chip System. Advanced Functional Materials. https://doi.org/10.1002/adfm.201805792
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.