Contact Lens Sensors in Ocular Diagnostics
Abstract
Contact lenses as a minimally invasive platform for diagnostics and drug delivery have emerged in recent years. Contact lens sensors have been developed for analyzing the glucose composition of tears as a surrogate for blood glucose monitoring and for the diagnosis of glaucoma by measuring intraocular pressure. However, the eye offers a wider diagnostic potential as a sensing site and therefore contact lens sensors have the potential to improve the diagnosis and treatment of many diseases and conditions. With advances in polymer synthesis, electronics and micro/nanofabrication, contact lens sensors can be produced to quantify the concentrations of many biomolecules in ocular fluids. Non‐ or minimally invasive contact lens sensors can be used directly in a clinical or point‐of‐care setting to monitor a disease state continuously. This article reviews the state‐of‐the‐art in contact lens sensor fabrication, their detection, wireless powering, and readout mechanisms, and integration with mobile devices and smartphones. High‐volume manufacturing considerations of contact lenses are also covered and a case study of an intraocular pressure contact lens sensor is provided as an example of a successful product. This Review further analyzes the contact lens market and the FDA regulatory requirements for commercialization of contact lens sensors.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Blood and tear fluid have a compositional difference due to the blood–tear barrier; however, the concentrations of analytes in both fluids have a relationship as a result of plasma leakage.57”
From Wearables in Medicine (2018) · cites this paper as [57]
In the citing paper
“Not only do biomarker molecules in tears diffuse directly from the blood and exhibit close tear–blood concentration correlations, but also tear analysis presents opportunities for the diagnosis of ocular disease.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [94]
In the citing paper
“Not only do biomarker molecules in tears diffuse directly from the blood and exhibit close tear–blood concentration correlations, but also tear analysis presents opportunities for the diagnosis of ocular disease.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [94]
In the citing paper
“In particular, tear glucose concentrations have been demonstrated to exhibit good correlation with blood glucose levels, reflecting the diffusion from the lachrymal artery when the tears are sampled without any eye irritation or stimulation, which can compromise the relationship94, 95, 99-101.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [94]
In the citing paper
“Given this background, a smart contact lens is a promising example of a wearable, health monitoring device (13, 14).”
From Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays (2018) · cites this paper as [13]
In the citing paper
“By considering the correlation between the tear glucose level and blood glucose level (15), a glucose sensor fitted on a contact lens can provide the noninvasive monitoring of user’s glucose levels from tear fluids with a consideration of the lag time between tear glucose level and blood glucose level in the range of 10 to 20 min (13–16).”
From Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays (2018) · cites this paper as [13]
In the citing paper
“In addition, the user’s tears can be collected in the contact lens by completely natural means, such as normal secretion and blinking, and used to assess various biomarkers found in the blood, such as glucose, cholesterol, sodium ions, and potassium ions (13).”
From Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays (2018) · cites this paper as [13]
Citations
Cites
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Fluorescence Spectroscopy of Single Biomolecules
Weiss, S. (1999) · Science · doi:10.1126/science.283.5408.1676 · Cited by 2,060
Clinical Methods: The History, Physical, and Laboratory Examinations
Kruse, J. A. (1990) · JAMA · doi:10.1001/jama.1990.03450210108045 · Cited by 2,040
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 2,017
Self-citationClinical Methods: The History, Physical, and Laboratory Examinations
(1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-113-7-563_2 · Cited by 1,408
Geigy, J. R. (1981) · Medical Entomology and Zoology · Cited by 1,221
The renaissance of fluorescence resonance energy transfer.
Selvin, P. R. (2000) · Nature Structural Biology · doi:10.1038/78948 · Cited by 998
Functional aspects of the tear film lipid layer
Bron, A. J., Tiffany, J. M., Gouveia, S. M., Yokoi, N., & Voon, L. W. (2003) · Experimental Eye Research · doi:10.1016/j.exer.2003.09.019 · Cited by 784
Solomon, A., Dursun, D., Liu, Z., Xie, Y., Macrì, A., & Pflugfelder, S. C. (2001) · PubMed · Cited by 721
Pflugfelder, S. C., Jones, D., Ji, Z., Afonso, A. A., & Monroy, D. C. (1999) · Current Eye Research · doi:10.1076/ceyr.19.3.201.5309 · Cited by 618
Research works printed but not linked: 22
- Novartis International AG Press Release “Novartis to license Google “smart lens” technology” 2014 1.
- Google Press Release “What is Google doing with a smart contact lens?”2014.
- Yan J., 2011, Conf. Proc. IEEE Eng. Med. Biol. Soc
- Brusini P., 2014, Atlas of Glaucoma
- Mochizuki M., 2004, Yamagata Med. J., 22, 9
- Daum K. M., 1982, Invest. Ophthalmol. Vis. Sci., 22, 509
- Green‐Church K. B., 2008, Mol. Vis., 14, 456
- Solomon A., 2001, Invest. Ophthalmol. Vis. Sci., 42, 2283
- Grus F. H., 2002, BMC Ophthalmol., 6, 2
- Tsuji F., 2012, Metabolomics, 2, 1
- McEwen W. K., 1969, Eye, 3, 34
- Chen R., 1996, J. Capillary Electrophor., 3, 243
- Sfuchell R. N., 1984, Invest. Ophthalmol. Vis. Sci., 25, 374
- Fullard R. J., 1990, Invest. Ophthalmol. Vis. Sci., 31, 1119
- Geddes C. D., 2006, Topics in Fluoresence Spectroscopy: Glucose Sensing
- Bennett E. S., 2005, Clinical Contact Lens Practice
- Tseng C.‐K., 2012, 2012 IEEE Sensors
- Domschke A., 2004, Proc. IEEE Sensors 2004
- Newlove D., 1981, Journal of the British Contact Lens Association
- Moezzi A. M., 2014, J. Optom, 1
- Barr J. T., 2005, Clinical Contact Lens Practice
- Schifrin L. G., 1984, The Contact Lens Industry: Structure, Competition and Public Policy (Health Technology Case Study 31)
Cited by
Sorted by citations
Items 301–400 of 462
Yetisen, A. K. (2014) · Springer theses · doi:10.1007/978-3-319-13584-7_4 · Cited by 12
Self-citationStructural Coloration in Caloenas Nicobarica Pigeons and Refractive Index Modulated Sensing
Rashid, I., Hassan, M. U., Khandwalla, A., Ameen, R. M., Yetisen, A. K., Dai, Q., & Butt, H. (2018) · Advanced Optical Materials · doi:10.1002/adom.201701218 · Cited by 12
Self-citationElectrochemical (bio-)sensors operating in human physiological fluids
Psotta, C. (2023) · doi:10.24834/isbn.9789178773992 · Cited by 12
Optically Transparent Antenna Arrays for the Next Generation of Mobile Networks
Green, R. B., Ding, K., Avrutin, V. S., Özgür, Ü., & Topsakal, E. (2022) · IEEE Open Journal of Antennas and Propagation · doi:10.1109/ojap.2022.3171322 · Cited by 11
Memon, R. S., Ali, M. M., Zafar, M., & Shaikh, A. J. (2019) · Journal of Global Health Reports · doi:10.29392//001c.11969 · Cited by 11
Electrochemical miniaturized devices
Dei, M., & Muñoz, F. X. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-823727-4.00014-6 · Cited by 11
Transparent and Capacitive Bioanode Based on Specifically Engineered Glucose Oxidase
González‐Arribas, E., Pankratov, D., Gounel, S., Mano, N., Blum, Z., & Shleev, S. (2016) · Electroanalysis · doi:10.1002/elan.201600096 · Cited by 11
Study on Injection Molding of Shell Mold for Aspheric Contact Lens Fabrication
Chen, C. A., Lien, V. T., & Qiu, Y. (2017) · Procedia Engineering · doi:10.1016/j.proeng.2017.04.104 · Cited by 11
Parametric Simulations of Slanted 1D Photonic Crystal Sensors
Breuer-Weil, A., Almasoud, N. N., Abbasi, B., Yetisen, A. K., Yun, S.-H., & Butt, H. (2016) · Nanoscale Research Letters · doi:10.1186/s11671-016-1321-0 · Cited by 11
Self-citationArafat, Y., Dutta, I., & Panat, R. P. (2016) · Journal of Applied Physics · doi:10.1063/1.4962453 · Cited by 11
Yadav, K. S., Tripathi, S., Vyas, J., Singhal, D., Joshi, G., & Soni, G. (2024) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2024.105949 · Cited by 10
Comprehensive Review on the Synthesis, Properties and Applications of Nanocomposite Contact Lenses
Sakr, A., Kamal, A., Jacob, L., Homsi, R., & Butt, H. (2024) · Journal of macromolecular science. Part C, Reviews in macromolecular chemistry and physics/Journal of macromolecular science. Reviews in macromolecular chemistry and physics · doi:10.1080/15583724.2024.2400961 · Cited by 10
Zhang, K., Han, L., Cai, H., Xue, X., Song, Y., Xin, W., Wang, Y., Liu, P., & Liu, J. (2025) · BMEMat · doi:10.1002/bmm2.70047 · Cited by 10
Siripongpreda, T., Pongsachareonnont, P. F., Chanajaree, R., & Rodthongkum, N. (2023) · Cellulose · doi:10.1007/s10570-023-05327-0 · Cited by 10
Yuan, W., Zhao, F., Liu, X., & Xu, J. (2023) · Biointerphases · doi:10.1116/6.0002618 · Cited by 10
Jaques, L. L., Malheiro, W. C., Jensen, A. T., & Machado, F. (2023) · Journal of environmental chemical engineering · doi:10.1016/j.jece.2023.111811 · Cited by 10
Exploring polymeric nanotextile devices: progress and outlook
Idumah, C. I., Odera, R. S., & Ezeani, E. O. (2024) · International Journal of Clothing Science and Technology · doi:10.1108/ijcst-06-2023-0087 · Cited by 10
Li, X., Li, H., Wang, Z., Wang, X., Zhang, J., Bin, F., Chen, W., Li, H., Huo, D., & Xiao, D. (2024) · Advanced Science · doi:10.1002/advs.202412630 · Cited by 10
Capillary flow in microchannel circuitry of scleral lenses
Yetisen, A. K., Soylemezoglu, B., Dong, J., Montelongo, Y., Butt, H., Jakobi, M., & Koch, A. W. (2019) · RSC Advances · doi:10.1039/c9ra01094g · Cited by 9
Self-citationNayak, K., Choudhari, M. V., Bagul, S., Chavan, T. A., & Misra, M. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819838-4.00006-7 · Cited by 10
Expert Views on Innovative Future Uses for Contact Lenses
Jones, L., Chauhan, A., Girolamo, N. D., Sheedy, J., & Smith, E. L., III (2015) · Optometry and Vision Science · doi:10.1097/opx.0000000000000700 · Cited by 9
Application of IoT-Based Smart Devices in Health Care Using Fog Computing
Mahapatra, S., & Singh, A. P. (2020) · Studies in big data · doi:10.1007/978-981-15-6044-6_11 · Cited by 9
Lai, C., & Shiau, F.-J. (2023) · Nanomaterials · doi:10.3390/nano13172441 · Cited by 8
Adhesion Mechanism, Applications, and Challenges of Ocular Tissue Adhesives
Hu, Z., He, X., Teng, L., Zeng, X., Zhu, S., Dong, Y., Zeng, Z., Zheng, Q., & Sun, X. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms26020486 · Cited by 8
Munaweera, R., Quinn, A., Morrow, L., Morris, R. A., & O’Mara, M. L. (2025) · Journal of Chemical Information and Modeling · doi:10.1021/acs.jcim.4c02375 · Cited by 8
Modeling of Cornea Applanation When Measuring Eye Pressure
Hučko, B., Kučera, Ľ., Ďuriš, S., Pavlasek, P., Rybář, J., & Hodál, J. (2019) · Lecture notes in mechanical engineering · doi:10.1007/978-3-030-33146-7_33 · Cited by 8
Nanoparticle-based biomedical sensors
Tricoli, A., & Bo, R. (2020) · Frontiers of nanoscience · doi:10.1016/b978-0-08-102515-4.00009-x · Cited by 8
Yetisen, A. K. (2014) · Springer theses · doi:10.1007/978-3-319-13584-7_5 · Cited by 8
Self-citationXiao, T., Zhang, H., Takamatsu, T., Ashimori, A., Azhari, S., Kimura, K., & Miyake, T. (2026) · npj Flexible Electronics · doi:10.1038/s41528-025-00507-3 · Cited by 8
Lahcen, A. A., & Amine, A. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-821661-3.00011-2 · Cited by 7
Sandaruwan, H. H. P. B., Manatunga, D. C., Liyanage, R. N., Costha, N. P., Dassanayake, R. S., Wijesinghe, R. E., Zhou, Y., & Liu, Y. (2024) · Analytical Methods · doi:10.1039/d4ay01178c · Cited by 7
Nanotechnology in Smart Contact Lenses: Highlights on Sensor Technologies and Future Prospects
Jino Affrald, R. (2022) · Current Nanomaterials · doi:10.2174/2405461508666221118153823 · Cited by 7
The Prospects for Holographic Sensors
Yetisen, A. K. (2014) · Springer theses · doi:10.1007/978-3-319-13584-7_7 · Cited by 7
Self-citationContact Lenses: Clinical Evaluation, Associated Challenges and Perspectives
ElShaer, A. (2017) · Pharmacy & Pharmacology International Journal · doi:10.15406/ppij.2017.05.00119 · Cited by 7
Effect of capillary bridges on the interfacial adhesion of wearable electronics to epidermis
Wang, Q., Chen, W. T., & Wu, J. C. (2019) · International Journal of Solids and Structures · doi:10.1016/j.ijsolstr.2019.05.029 · Cited by 7
Recent advances in I/E-skin: mechanism, signal processing, and applications
Wen, J., Xiang, C., Zhang, L., Shi, X., Zhou, S., Fan, T., Ning, H., Wang, S., Huang, K., Lee, A., et al. (2025) · Nano Materials Science · doi:10.1016/j.nanoms.2025.05.003 · Cited by 6
Chen, X., Zeng, Q., Chen, J. Y., Zhang, H., Chen, X., Jin, L., Wang, Q., & Tang, Z. (2025) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2025.126279 · Cited by 6
Remote Measurements of Tear Electrolyte Concentrations on Both Sides of an Inserted Contact Lens
Lakowicz, J. R., Badugu, R., Sivashanmugan, K., & Reece, A. E. (2023) · Chemosensors · doi:10.3390/chemosensors11080463 · Cited by 6
Zhang, F., Xu, W., Deng, Z., & Huang, J. (2025) · Frontiers in Medicine · doi:10.3389/fmed.2024.1487981 · Cited by 6
Healthcare with smart contact lenses: innovations, challenges, and future perspectives
Zhang, J., Dai, Y., & Lee, C. H. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-24790-3.00031-4 · Cited by 6
Self-moisturizing contact lens employing capillary flow
Aravind, M., Chidangil, S., & George, S. D. (2022) · Additive manufacturing · doi:10.1016/j.addma.2022.102842 · Cited by 6
NanoLC-timsTOF-Assisted Analysis of Glycated Albumin in Diabetes-Affected Plasma and Tears
Tan, Y., Toba, E. A. D. L., Rubakhin, S. S., Labriola, L. T., Canfield, C., Pan, D., & Sweedler, J. V. (2023) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.3c00331 · Cited by 6
Review—Recent Progress, Challenges, and Trends in Polymer-Based Wearable Sensors
Saxena, P., & Shukla, P. (2024) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ad3a18 · Cited by 6
Predictive Power of Polygenic Risk Scores for Intraocular Pressure or Vertical Cup-Disc Ratio
He, W., Lee, S. S., Díaz‐Torres, S., Han, X., Gharahkhani, P., Hunter, M. L., Balartnasingam, C., Craig, J. E., Hewitt, A. W., Mackey, D. A., et al. (2024) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2024.4856 · Cited by 6
Yetisen, A. K. (2014) · Springer theses · doi:10.1007/978-3-319-13584-7_3 · Cited by 6
Self-citation3.34 Biomaterials Challenges in Continuous Glucose Monitors In Vivo
Rao, A. N., Avula, M., & Grainger, D. W. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.09314-0 · Cited by 7
Miki, A., Kumoi, M., Maeda, N., Koh, S., Matsushita, K., & Nishida, K. (2020) · Japanese Journal of Ophthalmology · doi:10.1007/s10384-020-00723-6 · Cited by 6
Change in the geometry of positive- and negative-powered soft contact lenses during wear
Kałużny, B. J., Stachura, J., Mlyniuk, P., Villar, A. J., Wietlicka-Piszcz, M., & Grulkowski, I. (2020) · PLoS ONE · doi:10.1371/journal.pone.0242095 · Cited by 6
Coatable strain sensors for nonplanar surfaces
Park, C., Kim, J., Kang, J., Lee, B., Lee, H., Park, C., Yoon, J., Song, C., Kim, H., Yeo, W., et al. (2024) · Nanoscale · doi:10.1039/d4nr01324g · Cited by 5
Non-Invasive Wearable Sweat and Tear-Based Biosensors for Continuous Health Monitoring
Wu, C. (2023) · Highlights in Science Engineering and Technology · doi:10.54097/hset.v55i.9959 · Cited by 5
A surface-engineered contact lens for tear fluid biomolecule sensing
Aravind, M., & George, S. D. (2024) · Lab on a Chip · doi:10.1039/d4lc00176a · Cited by 5
Commercially available and recently approved hydrogels for clinical applications
Ovatlarnporn, C., & Basit, A. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-16168-1.00020-9 · Cited by 5
Maron, J. L., & Jones, G. B. (2018) · Clinical Therapeutics · doi:10.1016/j.clinthera.2018.01.004 · Cited by 5
Han, S. J., Park, H., Lee, J. O., & Choo, H. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.4.047002 · Cited by 5
Knowledge and attitude of youth towards contact lenses in Karachi, Pakistan
Irfan, R., Memon, R. S., Shaikh, M. Y., Khalid, I., Shakeel, N., & Tariq, E. (2019) · Journal of Global Health Reports · doi:10.29392//001c.11983 · Cited by 5
Introductory Chapter: Wearable Technologies for Healthcare Monitoring
Nasiri, N. (2019) · IntechOpen eBooks · doi:10.5772/intechopen.89297 · Cited by 6
Ion concentration measurement using synthetic microfluidic papers
Kamiya, H., Yasuga, H., & Miki, N. (2020) · PLoS ONE · doi:10.1371/journal.pone.0242188 · Cited by 5
Non-invasive wearable electrochemical biosensors for personalized applications in health management
Kang, X., Luo, A., Khan, N. A., Zhang, T., Ma, X., Zhao, Z., Tang, Y., Wang, W., Dai, K., Liang, A., et al. (2026) · Sensors International · doi:10.1016/j.sintl.2026.100381 · Cited by 4
Rath, R. J., Brasier, N., Quesada-González, D., Talebian, S., Langley, D., Sanli, A., Sempionatto, J. R., Greene, G. W., Beuschlein, F., Merkoçi, A., et al. (2026) · Device · doi:10.1016/j.device.2026.101214 · Cited by 4
Li, Z., Miao, X., Li, J., Lee, J., Li, X., Ahn, H., Wu, A., Zhao, W., Yun, J., & Lee, S. W. (2025) · ACS Nano · doi:10.1021/acsnano.5c05610 · Cited by 4
Muluneh, M. W., & Gebremichael, S. G. (2021) · Advances in Public Health · doi:10.1155/2021/5308376 · Cited by 4
Nano-inspired Point-of-Care Enzyme-Based Wearable Biosensors for Global Health Care
Kumar, V., & Arora, K. (2023) · Springer eBooks · doi:10.1007/978-981-15-6982-1_13 · Cited by 4
Hanstock, H. G., Edwards, J. P., Roberts, R., & Walsh, N. P. (2018) · Biological Psychology · doi:10.1016/j.biopsycho.2018.02.002 · Cited by 4
Central-to-peripheral corneal edema during wear of embedded-component contact lenses
Kim, Y. H., Lin, M. C., & Radke, C. J. (2021) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2021.101443 · Cited by 5
Special Types of Contact Lenses and Their Uses
Morris, J. A. (2018) · Elsevier eBooks · doi:10.1016/b978-0-7020-7168-3.00027-1 · Cited by 4
Min, G., Manjakkal, L., Mulvihill, D. M., & Dahiya, R. (2018) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2018.8589631 · Cited by 4
Tunable Contact of Epidermal Electronics With Skin Based on Ionic Polymer–Metal Composite Material
Chen, W., Ren, X., Wang, Q., & Wu, J. C. (2019) · Journal of Applied Mechanics · doi:10.1115/1.4042895 · Cited by 4
O’Donnell, C. (2017) · Elsevier eBooks · doi:10.1016/b978-0-7020-6660-3.00034-4 · Cited by 4
Wearable noninvasive glucose sensors based on graphene and other carbon materials
Antonova, I. V., & Ivanov, A. I. (2023) · Uspekhi Fizicheskih Nauk · doi:10.3367/ufnr.2023.08.039541 · Cited by 3
Recent Advancements in Flexible Biosensors for Continuous Glucose Monitoring
Cho, J., Jang, Y., Kim, J., Lee, I., & Lee, W. (2024) · Journal of Flexible and Printed Electronics · doi:10.56767/jfpe.2024.3.1.47 · Cited by 3
Design of transparent and flexible antenna for smart contact lenses
Rabhi, R., Gahgouh, S., Ribero, J., & Gharsallah, A. (2019) · Mediterranean Microwave Symposium · doi:10.1109/mms48040.2019.9157285 · Cited by 3
Wearable noninvasive glucose sensors based on graphene and other carbon materials
Antonova, I. V., & Ivanov, A. I. (2023) · Physics-Uspekhi · doi:10.3367/ufne.2023.08.039541 · Cited by 3
Nanotechnology Carriers for the Management, Electrochemical Detection and Diagnosis of Glaucoma
Gautam, D., Talwan, P., Chaurasia, H., Kumar, S., & Singh, R. (2024) · Springer eBooks · doi:10.1007/978-3-031-65902-7_15 · Cited by 3
Automation of Pick and Place Operation in Contact Lens Manufacturing
Wahab, N. A., & Thangaraj, J. (2018) · ELEKTRIKA- Journal of Electrical Engineering · doi:10.11113/elektrika.v17n2.95 · Cited by 3
Muluneh, M. W., & Tegegne, A. S. (2021) · Cancer Informatics · doi:10.1177/11769351211045975 · Cited by 3
Organic Electronics and Their Applications as Sensors
Raj, R., Singh, K. R., Verma, R., Singh, J., & Singh, R. P. (2023) · Wiley eBooks · doi:10.1002/9783527834266.ch15 · Cited by 3
Zhang, P., Nie, Y. G., Wang, X., Zhang, X., & Liu, L. (2025) · Bioactive Materials · doi:10.1016/j.bioactmat.2025.10.037 · Cited by 3
Sempionatto, J. R., & Gao, W. F. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-821661-3.00010-0 · Cited by 2
Shamaev, D. M., Zayats, V. V., Иомдина, Е. Н., Luzhnov, P. V., & Nikitin, O. I. (2022) · Russian Ophthalmological Journal · doi:10.21516/2072-0076-2022-15-2-177-185 · Cited by 2
Yuan, M. (2024) · Analog circuits and signal processing/Analog circuits and signal processing series · doi:10.1007/978-3-031-52834-7_7 · Cited by 2
Eye power and pressure detection using MEMS sensor
Nalini, M., Gayathiri, R., Ajitha, K., & Kirthika, S. (2021) · Materials Today Proceedings · doi:10.1016/j.matpr.2021.02.019 · Cited by 2
Chen, Y., Wang, J., Zhao, Y., Liu, X., Zhang, H., Murdoch, I., Hull, C. C., Barbur, J. L., Sun, T. S., & Grattan, K. T. V. (2019) · Measurement Sensors · doi:10.1016/j.measen.2019.100001 · Cited by 2
Nie, L., Hu, X., Zhao, Y., Wu, F., Wang, Y., Chen, L., Wang, Y., & Liu, Y. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.04.11.536356 · Cited by 2
Horiuchi, Y., Miyazeki, Y., Noh, J.-H., HONMA, H., Takai, O., & Cordonier, C. E. J. (2017) · Transactions of the IMF · doi:10.1080/00202967.2017.1256104 · Cited by 1
Advanced strategies in organoids for metabolic monitoring and metabolic disease modeling
Ma, W., Xu, Y., Gu, Z., & Li, D. (2025) · Nano Research · doi:10.26599/nr.2025.94907988 · Cited by 1
Artificial substitutes for Descemet's membrane - corneal endothelium complex: state of the art
Chalitangkoon, J., Giovannetti, F., Yousefi, S., Sun, Y., Fontana, L., Yeung, S. N., Ghaemi, R. V., Foster, E. J., & Iovieno, A. (2025) · Experimental Eye Research · doi:10.1016/j.exer.2025.110711 · Cited by 1
Synergizing technology and optics: Exploring the wonders of bioelectronics contact lenses
Abdulamiery, A. A., Shaker, L. M., & Al‐Amiery, A. A. (2025) · Next Materials · doi:10.1016/j.nxmate.2025.101399 · Cited by 1
Gao, L., Dong, J., & Wang, Y. (2026) · Chemosensors · doi:10.3390/chemosensors14060140 · Cited by 1
Khaldi, A., Menez, H., Murat, Q., Sallenave, X., Vidal, F., Aubert, P., Dupont, L., & Tocnaye, J.-L. D. B. D. L. (2024) · AIP Advances · doi:10.1063/5.0201708 · Cited by 1
Liquid plasters (skin glues) as a modern promising means for the treatment of wounds
Roik, O. M. (2024) · Gaceta Médica de Caracas · doi:10.47307/gmc.2024.132.4.27 · Cited by 1
Sun, L., Jia, H., Zhang, Y., Zhang, F., Qu, X., & Liang, J. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5c14938 · Cited by 1
Recent advances in smart contact lenses
Adibag, Z., Ghanbarzadeh, M., Salati, M. A., Rad, M. E., Ansari, R., Ta, C. N., Fadel, D., Mofidfar, M., & Abbasi, F. (2025) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2025.100734 · Cited by 1
2D material-based smart sensors for efficient and non-invasive glucose monitoring
Nisar, S., Dastgeer, G., Zulfiqar, M. W., Ghazanfar, H., Ahmad, M., Rabeel, M., Rasheed, A., Imran, M., & Kim, D. (2026) · Materials Today Physics · doi:10.1016/j.mtphys.2026.102028 · Cited by 2
MEMS enabled technologies for ocular monitoring and therapy
Meng, E. F., Yoon, E. J., & Gutierrez, C. A. (2017) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2017.7994066 · Cited by 1
Gürses, C., Melek, U. Y. A. N., Kuruçay, A., & Paşahan, A. (2021) · İnönü Üniversitesi Sağlık Hizmetleri Meslek Yüksek Okulu Dergisi · doi:10.33715/inonusaglik.986409 · Cited by 1
Rehmani, A., Shrivastava, V., Khan, S., & Parveen, N. (2022) · International Journal of Scientific Research in Science and Technology · doi:10.32628/ijsrst229453 · Cited by 1
Updates of Wearing Devices (WDs) In Healthcare, And Disease Monitoring
Naser, M., Nasr, M., & Shehata, L. H. (2023) · International Journal of Progressive Sciences and Technologies · doi:10.52155/ijpsat.v39.1.5361 · Cited by 1
Enzymatic Biosensor Platforms for Early Diagnosis of Diabetes
Singh, P., Pandey, S. K., & Wangoo, N. (2023) · Springer eBooks · doi:10.1007/978-981-15-6982-1_5 · Cited by 1
Ocular Abnormality Prevention System Using Machine learning
Dembele, N. G., & Dr Kamalraj, R. (2024) · International Journal of Research Publication and Reviews · doi:10.55248/gengpi.5.0324.0647 · Cited by 1
Nanosensors in Wearable Health Devices
Kumar, S., Gupta, S., Poria, R., & Kaushal, A. (2025) · Smart nanomaterials technology · doi:10.1007/978-981-96-6091-9_9 · Cited by 1
Metadata
- Authors
- Farandos, N. M., Yetisen, A. K., Monteiro, M. J., Lowe, C. R., & Yun, S. H.
- Affiliations
- Imperial College London (GB)
- University of Cambridge (GB)
- The University of Queensland (AU)
- Harvard University (US)
- Corresponding author
- Yetisen, Ali K.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2014-11-17
- Volume
- 4
- Issue
- 6
- Pages
- 792-810
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2055793978
- Cited by
- 466
- References
- 133
- Citations by year
- 2026: 16 · 2025: 29 · 2024: 42 · 2023: 48 · 2022: 47 · 2021: 51 · 2020: 52 · 2019: 50 · 2018: 44 · 2017: 37 · 2016: 24 · 2015: 18 · 2014: 8
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Advanced Healthcare Materials (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Health Sciences › Medicine › Ophthalmology › Ocular Surface and Contact Lens
- Keywords
- contact lens sensor, ocular diagnostics, glucose monitoring, tear glucose, glaucoma diagnosis, intraocular pressure, minimally invasive diagnosis, point-of-care monitoring, wireless power transfer, smartphone integration, contact lens manufacturing, FDA regulation, ocular drug delivery
- MeSH terms
- Contact Lenses, Electronics, Glaucoma, Humans, Intraocular Pressure, Biosensing Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review