Cited by 466Advanced Sensor and Energy Harvesting MaterialsElectrochemical sensors and biosensorsOcular Surface and Contact Lens

The DOI matches its Crossref record; 133 of the 133 references it cites were found in a registry or an index.

Contact Lens Sensors in Ocular Diagnostics

Abstract

Contact lenses as a minimally invasive platform for diagnostics and drug delivery have emerged in recent years. Contact lens sensors have been developed for analyzing the glucose composition of tears as a surrogate for blood glucose monitoring and for the diagnosis of glaucoma by measuring intraocular pressure. However, the eye offers a wider diagnostic potential as a sensing site and therefore contact lens sensors have the potential to improve the diagnosis and treatment of many diseases and conditions. With advances in polymer synthesis, electronics and micro/nanofabrication, contact lens sensors can be produced to quantify the concentrations of many biomolecules in ocular fluids. Non‐ or minimally invasive contact lens sensors can be used directly in a clinical or point‐of‐care setting to monitor a disease state continuously. This article reviews the state‐of‐the‐art in contact lens sensor fabrication, their detection, wireless powering, and readout mechanisms, and integration with mobile devices and smartphones. High‐volume manufacturing considerations of contact lenses are also covered and a case study of an intraocular pressure contact lens sensor is provided as an example of a successful product. This Review further analyzes the contact lens market and the FDA regulatory requirements for commercialization of contact lens sensors.

Overview

Integrity signals

Registry

Crossref · 10.1002/adhm.201400504

Cites

133 of 133 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Flagged first, then by citations

Show all 133 references

Research works printed but not linked: 22

  1. Novartis International AG Press Release “Novartis to license Google “smart lens” technology” 2014 1.
  2. Google Press Release “What is Google doing with a smart contact lens?”2014.
  3. Yan J., 2011, Conf. Proc. IEEE Eng. Med. Biol. Soc
  4. Brusini P., 2014, Atlas of Glaucoma
  5. Mochizuki M., 2004, Yamagata Med. J., 22, 9
  6. Daum K. M., 1982, Invest. Ophthalmol. Vis. Sci., 22, 509
  7. Green‐Church K. B., 2008, Mol. Vis., 14, 456
  8. Solomon A., 2001, Invest. Ophthalmol. Vis. Sci., 42, 2283
  9. Grus F. H., 2002, BMC Ophthalmol., 6, 2
  10. Tsuji F., 2012, Metabolomics, 2, 1
  11. McEwen W. K., 1969, Eye, 3, 34
  12. Chen R., 1996, J. Capillary Electrophor., 3, 243
  13. Sfuchell R. N., 1984, Invest. Ophthalmol. Vis. Sci., 25, 374
  14. Fullard R. J., 1990, Invest. Ophthalmol. Vis. Sci., 31, 1119
  15. Geddes C. D., 2006, Topics in Fluoresence Spectroscopy: Glucose Sensing
  16. Bennett E. S., 2005, Clinical Contact Lens Practice
  17. Tseng C.‐K., 2012, 2012 IEEE Sensors
  18. Domschke A., 2004, Proc. IEEE Sensors 2004
  19. Newlove D., 1981, Journal of the British Contact Lens Association
  20. Moezzi A. M., 2014, J. Optom, 1
  21. Barr J. T., 2005, Clinical Contact Lens Practice
  22. Schifrin L. G., 1984, The Contact Lens Industry: Structure, Competition and Public Policy (Health Technology Case Study 31)

Cited by

Sorted by citations

Items 401–462 of 462

Metadata

Authors
Farandos, N. M., Yetisen, A. K., Monteiro, M. J., Lowe, C. R., & Yun, S. H.
Affiliations
  • Imperial College London (GB)
  • University of Cambridge (GB)
  • The University of Queensland (AU)
  • Harvard University (US)
Corresponding author
Yetisen, Ali K.
Venue
Advanced Healthcare Materials
Publisher
Wiley
Published
2014-11-17
Volume
4
Issue
6
Pages
792-810
ISSN
  • 2192-2640 (ISSN-L)
  • 2192-2659
OpenAlex
W2055793978
Cited by
466
References
133
Citations by year
2026: 16 · 2025: 29 · 2024: 42 · 2023: 48 · 2022: 47 · 2021: 51 · 2020: 52 · 2019: 50 · 2018: 44 · 2017: 37 · 2016: 24 · 2015: 18 · 2014: 8
FWCI
2.48
Type
journal article
Language
en
Open access
closed
Locations
  • Advanced Healthcare Materials (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Health Sciences › Medicine › Ophthalmology › Ocular Surface and Contact Lens
Keywords
contact lens sensor, ocular diagnostics, glucose monitoring, tear glucose, glaucoma diagnosis, intraocular pressure, minimally invasive diagnosis, point-of-care monitoring, wireless power transfer, smartphone integration, contact lens manufacturing, FDA regulation, ocular drug delivery
MeSH terms
Contact Lenses, Electronics, Glaucoma, Humans, Intraocular Pressure, Biosensing Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review