The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Thin, Soft, Skin‐Mounted Microfluidic Networks with Capillary Bursting Valves for Chrono‐Sampling of Sweat
Abstract
Systems for time sequential capture of microliter volumes of sweat released from targeted regions of the skin offer the potential to enable analysis of temporal variations in electrolyte balance and biomarker concentration throughout a period of interest. Current methods that rely on absorbent pads taped to the skin do not offer the ease of use in sweat capture needed for quantitative tracking; emerging classes of electronic wearable sweat analysis systems do not directly manage sweat‐induced fluid flows for sample isolation. Here, a thin, soft, “skin‐like” microfluidic platform is introduced that bonds to the skin to allow for collection and storage of sweat in an interconnected set of microreservoirs. Pressure induced by the sweat glands drives flow through a network of microchannels that incorporates capillary bursting valves designed to open at different pressures, for the purpose of passively guiding sweat through the system in sequential fashion. A representative device recovers 1.8 µL volumes of sweat each from 0.8 min of sweating into a set of separate microreservoirs, collected from 0.03 cm 2 area of skin with approximately five glands, corresponding to a sweat rate of 0.60 µL min−1 per gland. Human studies demonstrate applications in the accurate chemical analysis of lactate, sodium, and potassium concentrations and their temporal variations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Calculation of percentage changes in volumes of blood, plasma, and red cells in dehydration.
Dill, D. B., & Costill, D. L. (1974) · Journal of Applied Physiology · doi:10.1152/jappl.1974.37.2.247 · Cited by 3,384
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
A Stretchable Form of Single-Crystal Silicon for High-Performance Electronics on Rubber Substrates
Khang, D.-Y., Jiang, H., Huang, Y., & Rogers, J. A. (2006) · Science · doi:10.1126/science.1121401 · Cited by 1,689
Self-citationGibson, L. E., & Cooke, R. E. (1959) · Pediatrics · doi:10.1542/peds.23.3.545 · Cited by 1,434
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Self-citationAdvantages and challenges of microfluidic cell culture in polydimethylsiloxane devices
Halldorsson, S., Lucumi, E., Gómez-Sjöberg, R., & Fleming, R. M. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.029 · Cited by 1,027
Imani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861
The mechanical properties of the rubber elastic polymer polydimethylsiloxane for sensor applications
Lötters, J. C., Olthuis, W., Veltink, P. H., & Bergveld, P. (1997) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/7/3/017 · Cited by 827
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
Cited by
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Self-citationBio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Self-citationWearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
Rich, S. I., Wood, R. J., & Majidi, C. (2018) · Nature Electronics · doi:10.1038/s41928-018-0024-1 · Cited by 1,022
Lim, H., Kim, H. S., Qazi, R., Kwon, Y., Jeong, J., & Yeo, W. (2020) · Advanced Materials · doi:10.1002/adma.201901924 · Cited by 1,002
Device integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 895
Enzyme‐Based Glucose Sensor: From Invasive to Wearable Device
Lee, H., Hong, Y. J., Baik, S., Hyeon, T., & Kim, D. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701150 · Cited by 778
Bandodkar, A. J., Gutruf, P., Choi, J., Lee, K., Sekine, Y., Reeder, J. T., Jeang, W. J., Aranyosi, A. J., Lee, S. P., Model, J. B., et al. (2019) · Science Advances · doi:10.1126/sciadv.aav3294 · Cited by 761
Self-citationAdvances in healthcare wearable devices
Iqbal, S. M. A., Mahgoub, I., Du, E., Leavitt, M. A., & Asghar, W. (2021) · npj Flexible Electronics · doi:10.1038/s41528-021-00107-x · Cited by 714
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
Shrivastava, S., Trung, T. Q., & Lee, N.-E. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00319c · Cited by 497
Martín, A., Kim, J., Kurniawan, J. F., Sempionatto, J. R., Moreto, J. R., Tang, G., Campbell, A. S., Shin, A., Lee, M. Y., Liu, X., et al. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00729 · Cited by 475
A wearable aptamer nanobiosensor for non-invasive female hormone monitoring
Ye, C., Wang, M., Min, J., Tay, R. Y., Lukas, H., Sempionatto, J. R., Li, J., Xu, C., & Gao, W. (2024) · Nature Nanotechnology · doi:10.1038/s41565-023-01513-0 · Cited by 466
Capillary microfluidics in microchannels: from microfluidic networks to capillaric circuits
Olanrewaju, A., Beaugrand, M., Yafia, M., & Juncker, D. (2018) · Lab on a Chip · doi:10.1039/c8lc00458g · Cited by 451
Skin-interfaced systems for sweat collection and analytics
Choi, J., Ghaffari, R., Baker, L. B., & Rogers, J. A. (2018) · Science Advances · doi:10.1126/sciadv.aar3921 · Cited by 433
Self-citationRoll-to-Roll Gravure Printed Electrochemical Sensors for Wearable and Medical Devices
Bariya, M., Shahpar, Z., Park, H., Sun, J., Jung, Y., Gao, W., Nyein, H. Y. Y., Liaw, T. S., Tai, L.-C., Ngo, Q. P., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b02505 · Cited by 417
Wearable Sensors for Biochemical Sweat Analysis
Bandodkar, A. J., Jeang, W. J., Ghaffari, R., & Rogers, J. A. (2019) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061318-114910 · Cited by 387
Self-citationChoi, J., Bandodkar, A. J., Reeder, J. T., Ray, T. R., Turnquist, A., Kim, S. B., Nyberg, N., Hourlier-Fargette, A., Model, J. B., Aranyosi, A. J., et al. (2019) · ACS Sensors · doi:10.1021/acssensors.8b01218 · Cited by 365
Self-citationDevice-assisted transdermal drug delivery
Lee, H., Song, C., Baik, S., Kim, D., Hyeon, T., & Kim, D.-H. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2017.08.009 · Cited by 343
Skin bioelectronics towards long-term, continuous health monitoring
Wang, Y., Haick, H., Guo, S., Wang, C., Lee, S., Yokota, T., & Someya, T. (2022) · Chemical Society Reviews · doi:10.1039/d2cs00207h · Cited by 318
Reeder, J. T., Choi, J., Xue, Y., Gutruf, P., Hanson, J., Liu, M., Ray, T., Bandodkar, A. J., Avila, R., Xia, W., et al. (2019) · Science Advances · doi:10.1126/sciadv.aau6356 · Cited by 308
Self-citationBioinspired Adhesive Architectures: From Skin Patch to Integrated Bioelectronics
Baik, S., Lee, H. J., Kim, D. W., Kim, J. W., Lee, Y., & Pang, C. (2019) · Advanced Materials · doi:10.1002/adma.201803309 · Cited by 302
Wearable electrochemical biosensors in North America
Min, J., Sempionatto, J. R., Teymourian, H., Wang, J., & Gao, W. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112750 · Cited by 278
Sekine, Y., Kim, S. B., Zhang, Y., Bandodkar, A. J., Xu, S., Choi, J., Irie, M., Ray, T. R., Kohli, P., Kozai, N., et al. (2018) · Lab on a Chip · doi:10.1039/c8lc00530c · Cited by 242
Self-citationBaker, L. B., Model, J. B., Barnes, K. A., Anderson, M. L., Lee, S. P., Lee, K. A., Brown, S. D., Reimel, A. J., Roberts, T. J., Nuccio, R. P., et al. (2020) · Science Advances · doi:10.1126/sciadv.abe3929 · Cited by 243
Self-citationHong, Y. J., Lee, H., Kim, J., Lee, M., Choi, H. J., Hyeon, T., & Kim, D. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201805754 · Cited by 229
Wearable Biosensors for Non-Invasive Sweat Diagnostics
Xu, J., Fang, Y., & Chen, J. (2021) · Biosensors · doi:10.3390/bios11080245 · Cited by 208
Khoshmanesh, F., Thurgood, P., Pirogova, E., Nahavandi, S., & Baratchi, S. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112946 · Cited by 204
A wearable patch for continuous monitoring of sweat electrolytes during exertion
Alizadeh, A., Burns, A., Lenigk, R., Gettings, R., Ashe, J., Porter, A., McCaul, M., Barrett, R., Diamond, D., White, P., et al. (2018) · Lab on a Chip · doi:10.1039/c8lc00510a · Cited by 180
Flexible Electrochemical Biosensors for Health Monitoring
Yang, A., & Yan, F. (2021) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.0c00534 · Cited by 122
Tear Glucose Measurement by Reflectance Spectrum of a Nanoparticle Embedded Contact Lens
Kim, S., Jeon, H.-J., Park, S., Lee, D. Y., & Chung, E. (2020) · Scientific Reports · doi:10.1038/s41598-020-65103-z · Cited by 83
Self-citationA review of sampling, energy supply and intelligent monitoring for long-term sweat sensors
Yang, P., Wei, G., Liu, A., Huo, F., & Zhang, Z. (2022) · npj Flexible Electronics · doi:10.1038/s41528-022-00165-9 · Cited by 77
Choi, J., Chen, S., Deng, Y., Xue, Y., Reeder, J. T., Franklin, D., Oh, Y. S., Model, J. B., Aranyosi, A. J., Lee, S. P., et al. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202000722 · Cited by 67
Liu, S., Yang, D. S., Wang, S., Luan, H., Sekine, Y., Model, J. B., Aranyosi, A. J., Ghaffari, R., & Rogers, J. A. (2023) · EcoMat · doi:10.1002/eom2.12270 · Cited by 60
Self-citationShajari, S., Salahandish, R., Zare, A., Hassani, M., Moossavi, S., Munro, E., Rashid, R., Rosenegger, D., Bains, J. S., & Sanati Nezhad, A. (2023) · Advanced Science · doi:10.1002/advs.202204171 · Cited by 55
Wearable Microfluidics for Continuous Assay
Lin, P.-H., Nien, H.-H., & Li, B.-R. (2023) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-091322-082930 · Cited by 28
Metadata
- Authors
- Choi, J., Kang, D., Han, S., Kim, S. B., & Rogers, J. A.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2017-01-20
- Volume
- 6
- Issue
- 5
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2579323355
- Cited by
- 315
- References
- 56
- FWCI
- 11.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.