The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
A Hydrogel Microneedle Patch for Point‐of‐Care Testing Based on Skin Interstitial Fluid
Abstract
Skin interstitial fluid (ISF) holds great potential as a highly desirable sample resource for point‐of‐care testing (POCT), where the key is to effectively collect target biomarkers from ISF. Hydrogel microneedle patch has great promise for ISF extraction. However, it is challenging to recover target biomarkers from the extracted skin ISF in hydrogel microneedle patches in an easy‐administrated, fast, and bulky instrument‐free manner. Herein, a hydrogel microneedle patch made of polyvinyl alcohol (PVA) and chitosan (CS) for POCT based on the ISF is developed. The phase transition property of PVA/CS hydrogel makes the microneedles stiff when dry, which is beneficial to easily penetrate into skin. Meanwhile, the highly porous microstructure of hydrogel offers good swelling ability for extraction of ISF and the thermal degradation property of PVA makes it convenient to quickly and efficiently recover target biomarkers from microneedle patch. The capability of this platform for POCT applications is further demonstrated by successful detections of typical biomarkers collected from the mimetic skin and monitoring the glucose level in rabbit skins during a day. The developed hydrogel microneedle patch holds the advantages of extraction of skin ISF and recovery of biomarkers, thus presenting as a powerful platform for skin ISF‐based POCT applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Martinez, A. W., Phillips, S. T., Carrilho, E., Thomas, S. W., Sindi, H., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac800112r · Cited by 1,443
Hassan, C. M., & Peppas, N. A. (2007) · Advances in Polymer Science · doi:10.1007/3-540-46414-x_2 · Cited by 1,356
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Gyles, D. A., Castro, L. D., Silva, J. O. C., & Ribeiro-Costa, R. M. (2017) · European Polymer Journal · doi:10.1016/j.eurpolymj.2017.01.027 · Cited by 527
Rapidly separable microneedle patch for the sustained release of a contraceptive
Li, W., Terry, R. N., Tang, J., Feng, M. R., Schwendeman, S. P., & Prausnitz, M. R. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0337-4 · Cited by 492
Chang, H., Zheng, M., Yu, X., Than, A., Seeni, R. Z., Kang, R., Tian, J., Khanh, D. P., Liu, L., Chen, P., et al. (2017) · Advanced Materials · doi:10.1002/adma.201702243 · Cited by 462
Yokoyama, F., Masada, I., Shimamura, K., Ikawa, T., & Monobe, K. (1986) · Colloid & Polymer Science · doi:10.1007/bf01412597 · Cited by 375
Lipani, L., Dupont, B. G. R., Doungmene, F., Marken, F., Tyrrell, R. M., Guy, R. H., & Ilie, A. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0112-4 · Cited by 340
Composition of interstitial fluid
Fogh-Andersen, N., Altura, B. M., Altura, B. T., & Siggaard-Andersen, O. (1995) · Clinical Chemistry · doi:10.1093/clinchem/41.10.1522 · Cited by 309
Sung, J. H., Hwang, M.-R., Kim, J. O., Lee, J. H., Kim, Y. I., Kim, J. H., Chang, S. W., Jin, S. G., Kim, J. A., & Lyoo, W. S. (2010) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.03.024 · Cited by 299
Kang, D.-K., Ali, M. M., Zhang, K., Huang, S. S., Peterson, E., Digman, M. A., Gratton, E., & Zhao, W. (2014) · Nature Communications · doi:10.1038/ncomms6427 · Cited by 297
Olatunji, O., Das, D. B., Garland, M. J., Belaid, L., & Donnelly, R. F. (2013) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.23439 · Cited by 277
Minimally Invasive Extraction of Dermal Interstitial Fluid for Glucose Monitoring Using Microneedles
Wang, P. M., Cornwell, M., & Prausnitz, M. R. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.131 · Cited by 267
Extraction and biomolecular analysis of dermal interstitial fluid collected with hollow microneedles
Miller, P. R., Taylor, R. M., Tran, B. Q., Boyd, G., Glaros, T., Chavez, V. H., Krishnakumar, R., Sinha, A., Poorey, K., Williams, K. P., et al. (2018) · Communications Biology · doi:10.1038/s42003-018-0170-z · Cited by 258
Physiological Differences Between Interstitial Glucose and Blood Glucose Measured in Human Subjects
Kulcu, E., Tamada, J. A., Reach, G., Potts, R. O., & Lesho, M. J. (2003) · Diabetes Care · doi:10.2337/diacare.26.8.2405 · Cited by 251
Al Sulaiman, D., Chang, J. Y. H., Bennett, N. R., Topouzi, H., Higgins, C. A., Irvine, D. J., & Ladame, S. (2019) · ACS Nano · doi:10.1021/acsnano.9b04783 · Cited by 233
Interstitial fluid lipoproteins.
Sloop, C. H., Dory, L., & Roheim, P. S. (1987) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)38701-0 · Cited by 228
Liu, Y., Vrana, N. E., Cahill, P. A., & McGuinness, G. B. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31310 · Cited by 206
Zu, Y., Zhang, Y., Zhao, X., Shan, C., Zu, S., Wang, K., Li, Y., & Ge, Y. (2012) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2011.10.006 · Cited by 203
Properties and swelling characteristics of cross‐linked poly(vinyl alcohol)/chitosan blend membrane
Kim, J. H., Kim, J. Y., Lee, Y. M., et al. (1992) · Journal of Applied Polymer Science · doi:10.1002/app.1992.070451004 · Cited by 193
Design, Development, and Evaluation of a Novel Microneedle Array-based Continuous Glucose Monitor
Jina, A., Tierney, M. J., Tamada, J. A., McGill, S., Desai, S., Chua, B., Chang, A., & Christiansen, M. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814526191 · Cited by 176
Caffarel-Salvador, E., Brady, A. J., Eltayib, E., Meng, T., Alonso-Vicente, A., Gonzalez-Vazquez, P., Torrisi, B. M., Vicente-Perez, E. M., Mooney, K., Jones, D. S., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0145644 · Cited by 174
Thennadil, S. N., Rennert, J. L., Wenzel, B. J., Hazen, K. H., Ruchti, T. L., & Block, M. B. (2001) · Diabetes Technology & Therapeutics · doi:10.1089/15209150152607132 · Cited by 166
Rebrin, K., Sheppard, N. F., & Steil, G. M. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400507 · Cited by 152
Bioresponsive Microneedles with a Sheath Structure for H2O2and pH Cascade‐Triggered Insulin Delivery
Zhang, Y., Wang, J., Yu, J., Wen, D., Kahkoska, A. R., Lü, Y., Zhang, X., Buse, J. B., & Gu, Z. (2018) · Small · doi:10.1002/smll.201704181 · Cited by 151
State of water in chitosan–PVA hydrogel
Wang, T., & Gunasekaran, S. (2006) · Journal of Applied Polymer Science · doi:10.1002/app.23526 · Cited by 139
Collection of Analytes from Microneedle Patches
Romanyuk, A. V., Zvezdin, V., Samant, P. P., et al. (2014) · Analytical Chemistry · doi:10.1021/ac503823p · Cited by 124
Chua, B., Desai, S. P., Tierney, M. J., Tamada, J. A., & Jina, A. N. (2013) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2013.09.026 · Cited by 111
Biagi, S., Ghimenti, S., Onor, M., & Bramanti, E. (2012) · Biomedical Chromatography · doi:10.1002/bmc.2713 · Cited by 110
Plasmonic Paper Microneedle Patch for On-Patch Detection of Molecules in Dermal Interstitial Fluid
Kolluru, C., Gupta, R., Jiang, Q., Williams, M., Derami, H. G., Cao, S., Noel, R. K., Singamaneni, S., & Prausnitz, M. R. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00258 · Cited by 86
Valdés‐Ramírez, G., Windmiller, J. R., Claussen, J. C., Martinez, A. G., Kuralay, F., Zhou, M., Zhou, N., Polsky, R., Miller, P. R., Narayan, R. J., et al. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.11.085 · Cited by 56
CancerSEEK and destroy — a blood test for early cancer detection
Killock, D. (2018) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2018.21 · Cited by 48
Sweat analysis following pressure ischaemia in a group of debilitated subjects.
Polliack, A. A., Taylor, R. P., & Bader, D. L. (1997) · PubMed · Cited by 41
Sakaguchi, K., Hirota, Y., Hashimoto, N., Ogawa, W., Sato, T., Okada, S., Hagino, K., Asakura, Y., Kikkawa, Y., Kojima, J., et al. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0255 · Cited by 35
Point-of-care tests poised to alter course of HIV treatment
Laursen, L. (2012) · Nature Medicine · doi:10.1038/nm0812-1156 · Cited by 19
Recovery Rate of Rat Skin Micropores Made by Dissolving Microneedles
Ito, Y., Hamazaki, N., Higashino, H., Miyamoto, N., Murakami, Y., Inoue, N., & Takada, K. (2013) · Journal of Drug Delivery Science and Technology · doi:10.1016/s1773-2247(13)50087-6 · Cited by 10
Kuranuki, S., Sato, T., Okada, S., Hosoya, S., Seko, A., Sugihara, K., & Nakamura, T. (2013) · Journal of Healthcare Engineering · doi:10.1260/2040-2295.4.4.529 · Cited by 8
Cited by
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
Antifouling Strategies for Selective In Vitro and In Vivo Sensing
Jiang, C., Wang, G., Hein, R., Liu, N., Luo, X., & Davis, J. J. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00739 · Cited by 598
Microneedle patch for the ultrasensitive quantification of protein biomarkers in interstitial fluid
Wang, Z., Luan, J., Seth, A., Liu, L., You, M., Gupta, P., Rathi, P., Wang, Y., Cao, S., Jiang, Q., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00672-y · Cited by 386
Chitosan-based microneedle arrays for dermal delivery of Centella asiatica
Ryall, C., Chen, S., Duarah, S., & Wen, J. (2022) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2022.122221 · Cited by 65
Microneedles: A novel clinical technology for evaluating skin characteristics
Kim, S. H., Kim, J. H., Choi, Y. M., Seo, S. M., Jang, E. Y., Lee, S. J., Cho, S., Jeong, D. H., & Lee, K. H. (2024) · Skin Research and Technology · doi:10.1111/srt.13647 · Cited by 10
Metadata
- Authors
- He, R., Niu, Y., Li, Z., Li, A., Yang, H., Xu, F., & Li, F.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2020-01-20
- Volume
- 9
- Issue
- 4
- Pages
- e1901201-e1901201
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W3001424928
- Cited by
- 257
- References
- 39
- FWCI
- 10.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.