J‐Aggregation Strategy toward Potentiated NIR‐II Fluorescence Bioimaging of Molecular Fluorophores
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Molecular fluorophores emitting in the second near‐infrared (NIR‐II, 1000–1700 nm) window with strong optical harvesting and high quantum yields hold great potential for in vivo deep‐tissue bioimaging and high‐resolution biosensing. Recently, J‐aggregates are harnessed to engineer long‐wavelength NIR‐II emitters and show unique superiority in tumor detection, vessel mapping, surgical navigation, and phototheranostics due to their bathochromic‐shifted optical bands in the required slip‐stacked arrangement aggregation state. However, despite the preliminary progress of NIR‐II J‐aggregates and theoretical study of structure‐property relationships, further paradigms of NIR‐II J‐aggregates remain scarce due to the lack of study on aggregated fluorophores with slip‐stacked fashion. In this effort, how to utilize the specific molecular structure to form slip‐stacked packing motifs with J‐type aggregated exciton coupling is emphatically elucidated. First, several molecular regulating strategies to achieve NIR‐II J‐aggregates containing intermolecular interactions and external conditions are positively summarized and deeply analyzed. Then, the recent reports on J‐aggregates for NIR‐II bioimaging and theranostics are systematically summarized to provide a clear reference and direction for promoting the development of NIR‐II organic fluorophores. Eventually, the prospective efforts on ameliorating and promoting NIR‐II J‐aggregates to further clinical practices are outlined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331
BODIPY dyes in photodynamic therapy
Kamkaew, A., Lim, S. H., Lee, H. B., Kiew, L. V., Chung, L. Y., & Burgess, K. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35216h · Cited by 2,104
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
Self-citationBashkatov, A. N., Genina, E. A., Kochubey, V. I., & Tuchin, V. V. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/004 · Cited by 1,720
Hu, Z., Fang, C., Li, B., Zhang, Z., Cao, C., Cai, M., Su, S., Sun, X., Shi, X., Li, C., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0494-0 · Cited by 1,126
J -Aggregates of Cyanine Dye for NIR-II in Vivo Dynamic Vascular Imaging beyond 1500 nm
Sun, C., Li, B., Zhao, M., Wang, S., Lei, Z., Lu, L., Zhang, H., Feng, L., Dou, C., Yin, D., et al. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b10043 · Cited by 582
Donor Engineering for NIR-II Molecular Fluorophores with Enhanced Fluorescent Performance
Yang, Q., Hu, Z., Zhu, S., Ma, R., Ma, H., Ma, Z., Wan, H., Zhu, T., Jiang, Z., Liu, W., et al. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.7b10334 · Cited by 554
Sheng, Z., Guo, B., Hu, D., Xu, S., Wu, W., Liew, W. H., Yao, K., Jiang, J., Liu, C., Zheng, H., et al. (2018) · Advanced Materials · doi:10.1002/adma.201800766 · Cited by 445
J-aggregates of meso-[2.2]paracyclophanyl-BODIPY dye for NIR-II imaging
Li, K., Duan, X., Jiang, Z., Ding, D., Chen, Y., Zhang, G.-Q., & Liu, Z. (2021) · Nature Communications · doi:10.1038/s41467-021-22686-z · Cited by 301
Wu, X., Jiang, Y., Rommelfanger, N. J., Yang, F., Zhou, Q., Yin, R., Liu, J., Cai, S., Ren, W., Shin, A., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00862-w · Cited by 222
Cited by
Near-infrared II fluorescence imaging
Schmidt, E. L., Ou, Z., Ximendes, E., Cui, H., Keck, C. H. C., Jaque, D., & Hong, G. (2024) · Nature Reviews Methods Primers · doi:10.1038/s43586-024-00301-x · Cited by 331
Recent advances in near-infrared-II organic J-aggregates for bio-applications
Xu, J., Zheng, X., Ren, T.-B., Shi, L., Yin, X., Yuan, L., & Zhang, X.-B. (2025) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2024.216379 · Cited by 48
Lee, K., Gao, Y., Chou, S., Wan, Y., Hsu, A. C., Tan, J., Li, Y., Guan, Z., Chen, H., Li, S., et al. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202407317 · Cited by 27
Activatable Molecular Probes With Clinical Promise for NIR‐II Fluorescent Imaging
Chen, Z., Zhou, Y., Li, L., Ma, W., Li, Y., & Yang, Z. (2025) · Small · doi:10.1002/smll.202411787 · Cited by 26
Self-citationLiang, Y., Pan, Y., Chen, L., Li, P., Xu, M., Zhou, H., Lu, X., Hu, W., Yin, C., & Fan, Q. (2024) · Angewandte Chemie International Edition · doi:10.1002/anie.202408861 · Cited by 22
Molecularly Locked π ‐Bridge Endows AIEgen with 1064 nm Excitation for Deep Tissue Imaging
Liu, W., Xie, H., Liu, J., Zhu, N., Wang, S., Wang, R., Zhang, X., Xu, G., Genin, G. M., Xu, F., et al. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202501668 · Cited by 12
Gao, W., Liu, D., Li, H., He, Z., Liu, Y., Li, X., Ma, H., & Shi, W. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202404996 · Cited by 1
Metadata
- Authors
- Hu, X., Zhu, C., Sun, F., Chen, Z., Zou, J., Chen, X., & Yang, Z.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2023-11-07
- Volume
- 36
- Issue
- 1
- Pages
- e2304848-e2304848
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W4385454521
- Cited by
- 176
- References
- 25
- FWCI
- 12.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.