CoChat

Ultrathin and Wearable Microtubular Epidermal Sensor for Real‐Time Physiological Pulse Monitoring

Xi, Wang, Yeo, Joo Chuan, Yu, Longteng, Zhang, Shuai, Lim, Chwee Teck · 2017 · Advanced Materials Technologies
Cited by 78

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

A flexible, stretchable, soft, and ultrathin wearable microtubular sensor that is highly sensitive to mechanical perturbations is developed. The sensor comprises a unique architecture consisting of a liquid‐state conductive element core within a soft silicone elastomer microtube. The microtubular sensor can distinguish forces as small as 5 mN and possesses a high force sensitivity of 68 N−1. The microtubular sensor occupies a tiny footprint of 120 µm in diameter, approximately the cross‐section of a strand of hair. Superior sensing capabilities of the sensor are reported to detect perturbations from pulsatile air flows and demonstrate its applicability in continuous and imperceptible real‐time monitoring of arterial pulse waves.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/admt.201700016

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

Metadata

Authors
Xi, W., Yeo, J. C., Yu, L., Zhang, S., & Lim, C. T.
Venue
Advanced Materials Technologies
Publisher
Wiley
Published
2017-04-10
Volume
2
Issue
5
ISSN
2365-709X (ISSN-L)
OpenAlex
W2606331555
Cited by
78
References
13
FWCI
4.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.