CoChat

Real‐time update of calibration model for better monitoring of batch processes using spectroscopy

Kornmann, Henri, Valentinotti, Sergio, Marison, Ian, Stockar, Urs von · 2004 · Biotechnology and Bioengineering
Cited by 12

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

In order to reduce the large calibration matrix usually required for calibrating multiwavelength optical sensors, a simple algorithm based on the addition in process of new standards is proposed. A small calibration model, based on 14 standards, is periodically updated by spectra collected on‐line during fermentation operation. Concentrations related to these spectra are reconciled into best‐estimated values, by considering carbon and oxygen balances. Using this method, fructose, acetate, and gluconacetan were monitored during batch fermentations of Gluconacetobacter xylinus 12281 using mid‐infrared spectroscopy. It is shown that this algorithm compensates for noncalibrated events such as production or consumption of by‐products. The standard error of prediction (SEP) values were 0.99, 0.10, and 0.90 g/L for fructose, acetate, and gluconacetan, respectively. By contrast, without an updating of the calibration model, the SEP values were 2.46, 0.92, and 1.04 g/L for fructose, acetate, and gluconacetan, respectively. Using only 14 standards, it was therefore possible to approach the performance of an 88‐standard‐based calibration model having SEP values of 1.11, 0.37, and 0.79 g/L for fructose, acetate, and gluconacetan, respectively. Therefore, the proposed algorithm is a valuable approach to reduce the calibration time of multiwavelength optical sensors. © 2004 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.20153

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 38

  1. 10.1016/S0141-0229(00)00271-4 · DOI
  2. 10.1002/bit.10383 · DOI · Paper page
  3. Beebe KR, 1987, An intoduction to multivariate calibration and analysis, Anal Chem, 59, 1007, 10.1021/ac00144a725 · doi:10.1021/ac00144a725 · Paper page
  4. Cannizzaro C, 2002, Spectroscopic monitoring of bioprocesses: a study of carotenoid production by Phaffia rhodozyma yeast
  5. 10.1023/A:1026784101162 · DOI
  6. 10.1021/bp990039b · DOI
  7. 10.1002/(SICI)1097-0290(19980520)58:4<428::AID-BIT10>3.0.CO;2-7 · DOI
  8. 10.1007/BF00172716 · DOI
  9. 10.1366/0003702963904872 · DOI
  10. 10.1016/0003-2670(86)80028-9 · DOI · Paper page
  11. 10.1016/S0958-1669(02)00295-1 · DOI
  12. 10.1002/bit.10058 · DOI · Paper page
  13. 10.1366/0003702021954421 · DOI
  14. 10.1128/AEM.69.10.6091-6098.2003 · DOI
  15. 10.1007/s00253-003-1299-2 · DOI
  16. 10.1002/bit.10618 · DOI · Paper page
  17. 10.1016/S0925-4005(98)00195-6 · DOI
  18. Luttik MAH, 1997, The low biomass yields of the acetic‐acid bacterium Acetobacter pasteurianus are due to a low stoichiometry of respiration‐coupled proton translocation, Appl Environ Microbiol, 63, 3345, 10.1128/aem.63.9.3345-3351.1997 · DOI
  19. 10.1111/j.1365-2672.1993.tb03015.x · doi:10.1111/j.1365-2672.1993.tb03015.x
  20. MadronF VerverkaV VanécékV.1977.Statistical analysis of material balance of a chemical reactor.23:482–486. · DOI
  21. Martens H, 1988, Multivariate calibration
  22. 10.1002/bit.10226 · DOI · Paper page
  23. 10.1016/0003-2670(95)00226-P · doi:10.1016/0003-2670(95)00226-p
  24. NoormanHJ RomeinB LuybenKCAM HeijnenJJ.1996.Classification error‐detection and reconciliation of process information in complex biochemical systems49:364–376. · doi:10.1002/(sici)1097-0290(19960220)49:4<364::aid-bit2>3.0.co;2-n
  25. 10.1007/s004490100226 · DOI
  26. 10.1002/bit.10093 · DOI · Paper page
  27. 10.1002/bit.10134 · DOI · Paper page
  28. Schulze U, 1995, Anaerobic physiology of Saccharomyces cerevisiae
  29. 10.1016/S0032-9592(01)00223-0 · DOI
  30. 10.1038/sj.jim.7000124 · DOI · Paper page
  31. 10.1016/S0003-2670(00)85460-4 · DOI
  32. Standard practice for qualifying spectrometers and spectrophotometers for use in multivariate analyses, calibrated using surrogate mixtures, 2000, Annual book of ASTM standards, 718
  33. Standard practice for infrared, multivariate, quantitative analysis (e 1655‐97), 1999, Annual book of ASTM standards, 844
  34. 10.1080/0738-859991229161 · DOI · Paper page
  35. 10.1002/bit.260430104 · DOI
  36. 10.1002/bit.260250906 · DOI · Paper page
  37. Wold S, 1984, Chemometrics, mathematics and statistics in chemistry, 17
  38. 10.1016/S0961-9534(02)00019-3 · DOI

Cited by

See all 12

Metadata

Authors
Kornmann, H., Valentinotti, S., Marison, I., & Stockar, U. V.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2004-08-17
Volume
87
Issue
5
Pages
593-601
ISSN
  • 0006-3592
  • 1097-0290
Cited by
12
References
5
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.