Cell patterning using magnetite nanoparticles and magnetic force
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Technologies for fabricating functional tissue architectures by patterning cells precisely are highly desirable for tissue engineering. Although several cell patterning methods such as microcontact printing and lithography have been developed, these methods require specialized surfaces to be used as substrates, the fabrication of which is time consuming. In the present study, we demonstrated a simple and rapid cell patterning technique, using magnetite nanoparticles and magnetic force, which enables us to allocate cells on arbitrary surfaces. Magnetite cationic liposomes (MCLs) developed in our previous study were used to magnetically label the target cells. When steel plates placed on a magnet were positioned under a cell culture surface, the magnetically labeled cells lined on the surface where the steel plate was positioned. Patterned lines of single cells were achieved by adjusting the number of cells seeded, and complex cell patterns (curved, parallel, or crossing patterns) were successfully fabricated. Since cell patterning using magnetic force may not limit the property of culture surfaces, human umbilical vein endothelial cells (HUVECs) were patterned on Matrigel, thereby forming patterned capillaries. These results suggest that the novel cell patterning methodology, which uses MCLs, is a promising approach for tissue engineering and studying cell–cell interactions in vitro. Biotechnol. Bioeng. 2007; 97: 1309–1317. © 2007 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Creation of long-lasting blood vessels
Koike, N., Fukumura, D., Gralla, O., Au, P., Schechner, J. S., & Jain, R. K. (2004) · Nature · doi:10.1038/428138a · Cited by 701
Analysis of Cell Mechanics in Single Vinculin-Deficient Cells Using a Magnetic Tweezer
Alenghat, F. J., Fabry, B., Tsai, K. Y., Goldmann, W. H., & Ingber, D. E. (2000) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2000.3636 · Cited by 216
Cited by
Recent advances in three‐dimensional multicellular spheroid culture for biomedical research
Lin, R., & Chang, H. (2008) · Biotechnology Journal · doi:10.1002/biot.200700228 · Cited by 1,264
Advances in multicellular spheroids formation
Cui, X., Hartanto, Y., & Zhang, H. (2017) · Journal of The Royal Society Interface · doi:10.1098/rsif.2016.0877 · Cited by 508
Nanoparticles in tissue engineering: applications, challenges and prospects
Hasan, A., Morshed, M., Memic, A., Hassan, S., Webster, T., & Marei, H. (2018) · International Journal of Nanomedicine · doi:10.2147/ijn.s153758 · Cited by 496
Nanotechnology in bone tissue engineering
Walmsley, G. G., McArdle, A., Tevlin, R., Momeni, A., Atashroo, D., Hu, M. S., Feroze, A. H., Wong, V. W., Lorenz, P. H., Longaker, M. T., et al. (2015) · Nanomedicine: Nanotechnology, Biology and Medicine · doi:10.1016/j.nano.2015.02.013 · Cited by 290
The use of electric fields in tissue engineering: A review
Markx, G. H. (2008) · Organogenesis · doi:10.4161/org.5799 · Cited by 92
A microfluidic co-culture system to monitor tumor-stromal interactions on a chip
Menon, N. V., Chuah, Y. J., Cao, B., Lim, M., & Kang, Y. (2014) · Biomicrofluidics · doi:10.1063/1.4903762 · Cited by 53
Roles of Spheroid Formation of Hepatocytes in Liver Tissue Engineering
Jiang, H.-L., Kim, Y.-K., Cho, K.-H., Jang, Y.-C., Choi, Y.-J., Chung, J.-H., & Cho, C.-S. (2010) · International Journal of Stem Cells · doi:10.15283/ijsc.2010.3.2.69 · Cited by 22
“fields (36) and ultrasound trap (37, 38) were used to en-”
Method
Metadata
- Authors
- Ino, K., Ito, A., & Honda, H.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2007-01-10
- Volume
- 97
- Issue
- 5
- Pages
- 1309-1317
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2149219233
- Cited by
- 151
- References
- 2
- FWCI
- 8.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.