The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Temporal profiling of cytokines in passively expressed sweat for detection of infection using wearable device
Abstract
This work presents the viability of passive eccrine sweat as a functional biofluid toward tracking the human body's inflammatory response. Cytokines are biomarkers that orchestrate the manifestation and progression of an infection/inflammatory event. Hence, noninvasive, real‐time monitoring of cytokines can be pivotal in assessing the progression of infection/inflammatory event, which may be feasible through monitoring of host immune markers in eccrine sweat. This work is the first experimental proof demonstrating the ability to detect inflammation/infection such as fever, FLU directly from passively expressed sweat in human subjects using a wearable “SWEATSENSER” device. The developed SWEATSENSER device demonstrates stable, real‐time monitoring of inflammatory cytokines in passive sweat. An accuracy of >90% and specificity >95% was achieved using SWEATSENSER for a panel of cytokines (interleukin‐6, interleukin‐8, interleukin‐10, and tumor necrosis factor‐α) over an analytical range of 0.2–200 pg mL −1 . The SWEATSENSER demonstrated a correlation of Pearson's r > 0.98 for the study biomarkers in a cohort of 26 subjects when correlated with standard reference method. Comparable IL‐8 levels (2–15 pg mL −1 ) between systemic circulation (serum) and eccrine sweat through clinical studies in a cohort of 15 subjects, and the ability to distinguish healthy and sick (infection) cohort using inflammatory cytokines in sweat provides pioneering evidence of the SWEATSENSER technology for noninvasive tracking of host immune response biomarkers. Such a wearable device can offer significant strides in improving prognosis and provide personalized therapeutic treatment for several inflammatory/infectious diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Sweat might also provide a useful avenue for wearable monitoring of pathogenic states such as viral infections86, cystic fibrosis87 or chronic inflammatory diseases, including gout8 or inflammatory bowel disease88.”
From End-to-end design of wearable sensors (2022) · cites this paper as [86]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An inflammatory cytokine signature predicts COVID-19 severity and survival
Del Valle, D. M., Kim-Schulze, S., Huang, H.-H., Beckmann, N. D., Nirenberg, S., Wang, B., Lavin, Y., Swartz, T. H., Madduri, D., Stock, A., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-1051-9 · Cited by 2,605
Reduction and Functional Exhaustion of T Cells in Patients With Coronavirus Disease 2019 (COVID-19)
Diao, B., Wang, C., Tan, Y., Chen, X., Liu, Y., Ning, L., Chen, L., Li, M., Liu, Y., Wang, G., et al. (2020) · Frontiers in Immunology · doi:10.3389/fimmu.2020.00827 · Cited by 2,475
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
Coperchini, F., Chiovato, L., Croce, L., Magri, F., & Rotondi, M. (2020) · Cytokine & Growth Factor Reviews · doi:10.1016/j.cytogfr.2020.05.003 · Cited by 1,288
Pedersen, S. F., & Ho, Y.-C. (2020) · Journal of Clinical Investigation · doi:10.1172/jci137647 · Cited by 1,137
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
The immunological anatomy of the skin
Kabashima, K., Honda, T., Ginhoux, F., & Egawa, G. (2019) · Nature Reviews Immunology · doi:10.1038/s41577-018-0084-5 · Cited by 650 · cited 1×
“The adherent intercellular junctions get diminished, causing immunoglobulins, cytokines, and water to move into the dermal interstitium.(17) These cytokines and other protein molecules then diffuse into eccrine sweat gland and reach the skin surface by hydrostatic pressure.”
BackgroundCytokine release syndrome with novel therapeutics for acute lymphoblastic leukemia
Frey, N. V., & Porter, D. L. (2016) · Hematology · doi:10.1182/asheducation-2016.1.567 · Cited by 222
Cizza, G., Marques, A. H., Eskandari, F., Christie, I. C., Torvik, S., Silverman, M. N., Phillips, T. M., & Sternberg, E. M. (2008) · Biological Psychiatry · doi:10.1016/j.biopsych.2008.05.035 · Cited by 208 · cited 2×
“Cizza et al.(18) and Marques-Deak et al.”
Wearable Sweat Band for Noninvasive Levodopa Monitoring
Tai, L.-C., Liaw, T. S., Lin, Y., Nyein, H. Y. Y., Bariya, M., Ji, W., Hettick, M., Zhao, C., Zhao, J., Hou, L., et al. (2019) · Nano Letters · doi:10.1021/acs.nanolett.9b02478 · Cited by 177
Research works printed but not linked: 32
- 10.1016/0955-2235(90)90009-9 · DOI
- 10.3389/fimmu.2019.01154 · DOI
- 10.1093/oxfordjournals.jbchem.a022636 · doi:10.1093/oxfordjournals.jbchem.a022636
- 10.1016/S0300-483X(98)00063-8 · DOI
- 10.1038/cmi.2015.74 · DOI · Paper page
- 10.1016/S0140-6736(20)30628-0 · DOI · Paper page
- 10.1056/NEJMra052211 · DOI · Paper page
- 10.1097/AIA.0b013e318034194e · DOI · Paper page
- 10.1016/j.sna.2019.07.020 · DOI
- 10.1080/23328940.2019.1632145 · DOI · Paper page
- 10.1016/j.jim.2010.11.010 · doi:10.1016/j.jim.2010.11.010
- 10.1016/j.apsusc.2017.12.026 · DOI
- 10.1039/c7an00548b · DOI
- 10.1002/elan.200603855 · DOI · Paper page
- 10.1146/annurev.anchem.012809.102211 · DOI · Paper page
- 10.1016/j.acax.2019.100029 · DOI
- 10.1093/cid/ciaa449 · DOI · Paper page
- 10.1385/1592593097 · doi:10.1385/1592593097
- FazalN.T Cell Suppression in Burn and Septic Injuries. Immunosuppression—Role in Health and Diseases;2012. doi:https://doi.org/10.5772/26523 · DOI
- 10.3390/ijms19051442 · DOI
- 10.3390/pharmaceutics10030131 · DOI · Paper page
- McEnroe RJ, 2005, Interference Testing in Clinical Chemistry; Approved Guideline
- 10.1093/jat/bkz116 · DOI
- 10.1097/FTD.0b013e318180c83d · DOI
- 10.1016/j.jim.2017.11.003 · DOI
- 10.1007/s40820-018-0193-5 · DOI
- 10.1002/elan.201800677 · DOI
- 10.1016/j.jid.2020.05.107 · DOI
- 10.1093/ibd/izaa191 · DOI
- 10.1039/C9LC00103D · DOI · Paper page
- 10.1203/00006450-198508000-00020 · DOI
- 10.1002/adfm.201906713 · DOI · Paper page
Cited by
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
Applied body-fluid analysis by wearable devices
Brasier, N., Wang, J., Gao, W., Sempionatto, J. R., Dincer, C., Ates, H. C., Güder, F., Olenik, S., Schauwecker, I., Schaffarczyk, D., et al. (2024) · Nature · doi:10.1038/s41586-024-08249-4 · Cited by 298
Biomolecular sensors for advanced physiological monitoring
Flynn, C. D., Chang, D., Mahmud, A., Yousefi, H., Das, J., Riordan, K. T., Sargent, E. H., & Kelley, S. O. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00067-z · Cited by 226
Izmailova, E. S., Maguire, R. P., McCarthy, T. J., Müller, M. L. T. M., Murphy, P., & Stephenson, D. (2023) · Clinical and Translational Science · doi:10.1111/cts.13461 · Cited by 17
Utilizing Wearable Device Data for Syndromic Surveillance: A Fever Detection Approach
Kasl, P., Keeler Bruce, L., Hartogensis, W., Dasgupta, S., Pandya, L. S., Dilchert, S., Hecht, F. M., Gupta, A., Altintas, I., Mason, A. E., et al. (2024) · Sensors · doi:10.3390/s24061818 · Cited by 13
Metadata
- Authors
- Jagannath, B., Lin, K., Pali, M., Sankhala, D., Muthukumar, S., & Prasad, S.
- Affiliations
- Department of Bioengineering University of Texas at Dallas Richardson Texas USA
- Department of Electrical Engineering University of Texas at Dallas Richardson Texas USA
- EnLiSense LLC Allen Texas USA
- ORCID
- Prasad, Shalini
- Venue
- Bioengineering & Translational Medicine
- Publisher
- Wiley
- Published
- 2021-04
- Volume
- 6
- Issue
- 3
- ISSN
- 2380-6761
- Cited by
- 98
- References
- 15
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.