The DOI matches its Crossref record; 65 of the 68 references it cites were found in a registry or an index.
Tear Based Bioelectronics
Abstract
This work provides an overview of the recent advances in the field of tear‐based wearable electrochemical biodevices, including non‐invasive biosensors, biological fuel cells and biosupercapacitors. Contact lenses are attractive platforms for fabricating non‐invasive self‐contained gadgets for different applications, starting from devices with casual or mundane purposes only, like personalized smart lenses with direct (invisible for others) displays, and ending with biomedical devices for continuous fitness status and/or health care monitoring. Key requirements and challenges that confront researchers in this exciting area are discussed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“As the concentration of the glucose increases, the phenylboronic acid functionalized hydrogel swells due to Donnan osmotic pressure changes.71”
From Wearables in Medicine (2018) · cites this paper as [71]
In the citing paper
“Not only do biomarker molecules in tears diffuse directly from the blood and exhibit close tear–blood concentration correlations, but also tear analysis presents opportunities for the diagnosis of ocular disease.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [98]
In the citing paper
“Not only do biomarker molecules in tears diffuse directly from the blood and exhibit close tear–blood concentration correlations, but also tear analysis presents opportunities for the diagnosis of ocular disease.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [98]
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics
Kim, J., Imani, S., de Araujo, W. R., Warchall, J., Valdés-Ramírez, G., Paixão, T. R. L. C., Mercier, P. P., & Wang, J. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.039 · Cited by 678
Biofouling: lessons from nature
Bixler, G. D., & Bhushan, B. (2012) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2011.0502 · Cited by 589
A contact lens with embedded sensor for monitoring tear glucose level
Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., & Parviz, B. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.042 · Cited by 513
Berman, E. R. (1991) · Springer eBooks · doi:10.1007/978-1-4757-9441-0 · Cited by 482
Contact Lens Sensors in Ocular Diagnostics
Farandos, N. M., Yetisen, A. K., Monteiro, M. J., Lowe, C. R., & Yun, S. H. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400504 · Cited by 466
Clinical biochemistry of tears
Haeringen, N. J. V. (1981) · Survey of Ophthalmology · doi:10.1016/0039-6257(81)90145-4 · Cited by 445
Tattoo-based potentiometric ion-selective sensors for epidermal pH monitoring
Bandodkar, A. J., Hung, V. W. S., Jia, W., Valdés-Ramírez, G., Windmiller, J. R., Martinez, A. G., Ramírez, J., Chan, G., Kerman, K., & Wang, J. (2013) · The Analyst · doi:10.1039/c2an36422k · Cited by 379
A 3-$\mu\hbox{W}$ CMOS Glucose Sensor for Wireless Contact-Lens Tear Glucose Monitoring
Liao, Y.-T., Yao, H., Lingley, A., Parviz, B., & Otis, B. P. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2170633 · Cited by 372
Research works printed but not linked: 9
- Willner I., 2000, Angew. Chem., Int. Ed., 39, 1181
- Agarwal S., 2002, Textbook of ophthalmology, 1st ed
- Nichols B. A., 1985, Invest. Ophthalmol. Vis. Sci., 26, 464
- Carney L. G., 1989, Invest. Ophthalmol. Vis. Sci., 30, 747
- Benjamin W. J., 1983, Invest. Ophthalmol. Vis. Sci., 24, 1624
- Phillips A., 2007, Contact lenses
- Choy C. K. M., 2003, Curr. Eye Res., 27
- Green‐Church K. B., 2008, Mol. Vision, 14, 456
- N. Efron Contact lens practice 1st ed. Elsevier Butterworth‐Heinemann 2002.
Cited by
Sorted by citations
Items 101–135 of 135
Cui, Y., Zhuo, L., Nishina, Y., Azhari, S., & Miyake, T. (2025) · Advanced Intelligent Systems · doi:10.1002/aisy.202500368 · Cited by 8
Assembling a Low‐volume Biofuel Cell on a Screen‐printed Electrode for Glucose Sensing
Becker, J. M., Lielpētere, A., Szczesny, J., Ruff, A., Conzuelo, F., & Schuhmann, W. W. (2022) · Electroanalysis · doi:10.1002/elan.202200084 · Cited by 8
Lahcen, A. A., & Amine, A. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-821661-3.00011-2 · Cited by 7
Xie, B., Wang, K., Li, B., Huang, R., Xu, Z., & Li, X. (2023) · Journal of Materials Chemistry B · doi:10.1039/d3tb00034f · Cited by 6
3D-Printed Contact Lenses: Challenges Towards Translation and Commercialization
Ozdalgic, B., Yetisen, A. K., & Taşoğlu, S. (2022) · Journal of 3D Printing in Medicine · doi:10.2217/3dp-2022-0010 · Cited by 6
Ozbey, S., AKKAŞ, T., Kaplan, T. E., Polatoğlu, İ., Şen, M., & Kurbanoğlu, S. (2026) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2026.118698 · Cited by 5
Photo- and pH-dually responsive hydrogel containing spirooxazine groups
Zou, Y.-L., 邹, 钰., Gao, H., Su, C., Wang, M., & Gao, J. G. (2024) · Journal of Polymer Research · doi:10.1007/s10965-024-03877-w · Cited by 5
Noninvasive biomarker sensors using surface-enhanced Raman spectroscopy
Sunil, N., & Pullithadathil, B. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-824008-3.00002-3 · Cited by 4
Starch/methyl cellulose-based microsupercapacitors for on-chip applications
Nigam, R., & Kar, K. K. (2023) · Journal of Materials Science Materials in Electronics · doi:10.1007/s10854-023-11296-8 · Cited by 4
Introductory Chapter: Wearable Technologies for Healthcare Monitoring
Nasiri, N. (2019) · IntechOpen eBooks · doi:10.5772/intechopen.89297 · Cited by 6
A Green High‐k Dielectric from Modified Carboxymethyl Cellulose‐Based with Dextrin
Santoso, L. L., Prakoso, S. P., Bui, H., Hong, Q., Huang, S., Chiang, T., Huang, K., Nurkhamidah, S., Tristantini, D., & Chiu, Y. (2024) · Macromolecular Rapid Communications · doi:10.1002/marc.202400059 · Cited by 3
Fu, Y., Yang, A., & Yan, F. (2017) · Springer eBooks · doi:10.1007/978-3-319-69362-0_12 · Cited by 3
Nanomaterials-based flexible electrochemical sensors for health care monitoring
Mohan, A. M. V., & Starvin, A. M. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-824008-3.00010-2 · Cited by 2
Zafar, F., Shoukat, N., Sikandar, M., Akhtar, N., Mazhar, M., & Majeed, S. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-89955-0.00007-8 · Cited by 1
Applications for biofuel cells
Rao, X., Zhao, P., Yu, Y., & Dong, S. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-13835-5.00004-8 · Cited by 1
Recent advances in smart contact lenses
Adibag, Z., Ghanbarzadeh, M., Salati, M. A., Rad, M. E., Ansari, R., Ta, C. N., Fadel, D., Mofidfar, M., & Abbasi, F. (2025) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2025.100734 · Cited by 1
Zeng, X., & Bao, S. (2023) · Advanced and intelligent manufacturing in China · doi:10.1007/978-981-99-7603-4_3 · Cited by 1
Updates of Wearing Devices (WDs) In Healthcare, And Disease Monitoring
Naser, M., Nasr, M., & Shehata, L. H. (2023) · International Journal of Progressive Sciences and Technologies · doi:10.52155/ijpsat.v39.1.5361 · Cited by 1
Psoma, S. D., & Ndege, G. (2025) · EMJ Innovation · doi:10.33590/emjinnov/fgtg8403 · Cited by 2
Building An Electrochemical Contact Lens Biosensor
Jordan, C. T. (2016) · CommonKnowledge Research Repository (Pacific University Oregon)
Eye-Fi: Integrating optical data communication into intraocular lenses
Vecchia, V., Silva, M. F., & Monteiro, D. W. D. L. (2018) · Global LiFi Congress (GLC) · doi:10.23919/glc.2018.8319107
Flexible and Stretchable Biointerfacing for Healthcare Diagnostics
Rajabi, M. (2019) · KTH Publication Database DiVA (KTH Royal Institute of Technology)
Blue copper proteins as bioelements for bioelectronic devices
Aleksejeva, O. (2019) · doi:10.24834/9789178770014
Soft mechanical and biochemical sensors
Koh, A. S., & Vikas, V. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819246-7.00004-8
Fabrication and Applications of Antibacterial Surfaces and Nano Biosensing Platforms
Jaggessar, A., Hasan, J., & Yarlagadda, P. K. D. V. (2022) · Lecture notes in networks and systems · doi:10.1007/978-3-030-90532-3_58
Nien, H., & Li, B. (2023) · Revista de Química · doi:10.18800/quimica.202302.003
Sample preparation using microfluidic technologies for non-invasive tests
Oksuz, C., Tarim, E. A., Ozcan, H. A., Koc, S., & Tekin, H. C. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15978-7.00038-2 · Cited by 1
Biosensor for noninvasive measurements
Gupta, M., Yadav, V. K., Sen, P., Chauhan, N., & Saini, M. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-21592-6.00017-3
Huang, X., Jiao, Y., Yang, Y., & Li, J. (2025) · Wiley eBooks · doi:10.1002/9783527845507.ch2
Functionalized nanothin films for noninvasive biosensing
Jose, J., Muhammed Ali, V. P., Uthara, K., Mk, S., Sandeep, B. S., Anagha, C., Vijay, A., Radhakrishnan, E. K., & Pereira, M. L. G. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-18929-6.00018-9
Electrode nanostructuration for enzyme electrocatalyst : towards a "green" H2/O2 fuel cell
Monsalve, K. (2016) · theses.fr (ABES) · doi:10.70675/276fd8d8z733az4cbczbe63z023e958f286d
Conception et optimisation de piles enzymatiques glucose-O2 pour la gestion de puissance
Abreu, C. (2017) · theses.fr (ABES) · doi:10.70675/1df1facbzbe5cz4c73za7e0zb231f3a986ae
Suzuki, H., & Sassa, F. (2026) · Modern aspects of electrochemistry · doi:10.1007/978-981-95-6483-5_8
Peng, Y., Huang, X., Zhang, X., Jiang, Y., Zhang, X., Zeng, X., Sun, F., Liu, P., Zhou, J., Luo, Z., et al. (2026) · Interdisciplinary medicine · doi:10.1002/inmd.70132
Next-generation wearable electrochemical sensors for personalized healthcare
Khan, W. U., Rind, S., Zhao, H., & Zhang, Q. (2026) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2026.101926
Metadata
- Authors
- Pankratov, D., González‐Arribas, E., Blum, Z., & Shleev, S.
- Affiliations
- Malmö University (SE)
- Corresponding author
- Shleev, Sergey
- Venue
- Electroanalysis
- Publisher
- Wiley
- Published
- 2016-01-20
- Volume
- 28
- Issue
- 6
- Pages
- 1250-1266
- ISSN
- 1040-0397 (ISSN-L)
- 1521-4109
- OpenAlex
- W2337816605
- Cited by
- 135
- References
- 68
- Citations by year
- 2026: 5 · 2025: 8 · 2024: 7 · 2023: 14 · 2022: 16 · 2021: 14 · 2020: 12 · 2019: 16 · 2018: 18 · 2017: 18 · 2016: 7
- FWCI
- 9.07
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Electroanalysis (publishedVersion)
- Malmö University Publications (Malmö University) (submittedVersion)
- Funders
- Samsung Electronics Co., Ltd.
- Russian Foundation for Basic Research (13-04-12063, 14-04-32235)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Keywords
- non-invasive biosensors, biofuel cells, contact lenses, smart contact lenses, health monitoring, continuous health monitoring, bioelectrochemical systems
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›