An experimental investigation on frosting characteristics of a microchannel outdoor heat exchanger in an air conditioning heat pump system for electric vehicles

Li, Kang, Luo, Shuxian, Yu, Jun, Tang, Qitian, Su, Lin, Fang, Yidong·2020·International Journal of Energy Research

Abstract

To increase the driving range of electric vehicles in cold climate, air conditioning heat pump (ACHP) system is supposed to be the most effective solution. Working near 0°C with high humidity, the microchannel outdoor heat exchanger (OHX) in system would experience badly frosting process, like traditional residential heat pump system. It would lead to a significant reduction of system performance without defrosting in time. In this article, experimental investigation has been implemented on the frosting process of ACHP system of electric vehicles which is with a microchannel OHX. The phenomenon of frosting distribution was observed, the frosted part on surface shows uneven with various flows paths. The typical frosting characteristics of an outdoor microchannel heat exchanger were also obtained. In a self-designed three-heat exchanger ACHP system, the inlet and outlet refrigerant temperature of OHX as well as the outlet air temperature of system decrease with increasing frosting coverage rate. The frosting phenomenon was analyzed with variation of ambient temperature and humidity. System influence by frosting was also studied with under different ambient conditions. When OHX begins to frost, the heating capacity reduction of system under different ambient conditions were both increased but the differences in the coefficient of performance (COP) variations under different ambient conditions were small as frosting progressed.

Integrity signals

Registry

Crossref · 10.1002/er.5519

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Li, K., Luo, S., Yu, J., Tang, Q., Su, L., & Fang, Y.
Affiliations
  • University of Shanghai for Science and Technology (CN)
  • SAIC Motor (China) (CN)
Corresponding author
Yu, Jun
Venue
International Journal of Energy Research
Publisher
Wiley
Published
2020-05-05
Volume
44
Issue
9
Pages
7807-7819
ISSN
  • 0363-907X (ISSN-L)
  • 1099-114X
OpenAlex
W3022173272
Cited by
13
References
32
Citations by year
2026: 1 · 2025: 2 · 2024: 1 · 2023: 3 · 2022: 2 · 2021: 3 · 2020: 1
FWCI
1.11
Type
journal article
Language
en
Open access
closed
Locations
International Journal of Energy Research (publishedVersion)
Funders
  • Capacity Building Plan for some Non-military Universities and Colleges of Shanghai Scientific Committee (18060502600)
  • National Nature Science Foundation of China (51876130, 51906158)
  • Shanghai Sailing Program (18YF1417900)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
  • Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
Keywords
frost formation, microchannel heat exchangers, outdoor heat exchanger, electric vehicles, coefficient of performance, air humidity, ambient temperature, thawing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review