Cited by 24Heat Transfer and OptimizationHeat Transfer MechanismsRefrigeration and Air Conditioning Technologies

Frost behavior of a louvered fin heat exchanger with vortex-generating fins

Open access
Park, Jin-Seong, Byun, Sungjoon, Kim, Dong Rip, Lee, Kwan-Soo·2017·International Journal of Heat and Mass Transfer

Integrity signals

Registry

Crossref · 10.1016/j.ijheatmasstransfer.2017.06.090

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Park, J.-S., Byun, S., Kim, D. R., & Lee, K.-S.
Affiliations
  • Korea Institute of Nuclear Safety (KR)
  • Hanyang University (KR)
Corresponding author
Lee, Kwan-Soo
Venue
International Journal of Heat and Mass Transfer
Publisher
Elsevier BV
Published
2017-11
Volume
114
Pages
590-596
ISSN
0017-9310 (ISSN-L)
OpenAlex
W2731853584
Cited by
24
References
21
Citations by year
2026: 4 · 2025: 2 · 2024: 5 · 2023: 4 · 2022: 2 · 2021: 2 · 2020: 2 · 2019: 2 · 2017: 1
FWCI
1.06
Type
journal article
Language
en
Open access
Locations
  • International Journal of Heat and Mass Transfer (publishedVersion)
  • The Royal Society of Chemistry’s Journals, Books and Databases (The Royal Society of Chemistry) (submittedVersion, cc-by-nc-nd)
Funders
Korean government (2016R1A2B4012954)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer Mechanisms
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
Keywords
louvered fin heat exchanger, frost formation, airflow characteristics, heat transfer enhancement, air conditioning heat exchangers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review