CoChat

The sintered microsphere matrix for bone tissue engineering: In vitro osteoconductivity studies

Borden, Mark, Attawia, Mohamed, Laurencin, Cato T. · 2002 · Journal of Biomedical Materials Research
Cited by 154

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

A tissue engineering approach has been used to design three‐dimensional synthetic matrices for bone repair. The osteoconductivity and degradation profile of a novel polymeric bone‐graft substitute was evaluated in an in vitro setting. Using the copolymer poly(lactide‐co‐glycolide) [PLAGA], a sintering technique based on microsphere technology was used to fabricate three‐dimensional porous scaffolds for bone regeneration. Osteoblasts and fibroblasts were seeded onto a 50:50 PLAGA scaffold. Morphologic evaluation through scanning electron microscopy demonstrated that both cell types attached and spread over the scaffold. Cells migrated through the matrix using cytoplasmic extensions to bridge the structure. Cross‐sectional images indicated that cellular proliferation had penetrated into the matrix approximately 700 μm from the surface. Examination of the surfaces of cell/matrix constructs demonstrated that cellular proliferation had encompassed the pores of the matrix by 14 days of cell culture. With the aim of optimizing polymer composition and polymer molecular weight, a degradation study was conducted utilizing the matrix. The results demonstrate that degradation of the sintered matrix is dependent on molecular weight, copolymer ratio, and pore volume. From this data, it was determined that 75:25 PLAGA with an initial molecular weight of 100,000 has an optimal degradation profile. These studies show that the sintered microsphere matrix has an osteoconductive structure capable of functioning as a cellular scaffold with a degradation profile suitable for bone regeneration. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 61: 421–429, 2002

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.10201

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 154

Metadata

Authors
Borden, M., Attawia, M., & Laurencin, C. T.
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
2002-05-15
Volume
61
Issue
3
Pages
421-429
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W2160478451
Cited by
154
References
4
FWCI
5.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The sintered microsphere matrix for bone tissue engineering: In vitro osteoconductivity studies. https://app.cochat.ai/papers/10.1002/jbm.10201
The paper
Borden, M., Attawia, M., & Laurencin, C. T. (2002). The sintered microsphere matrix for bone tissue engineering: In vitro osteoconductivity studies. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.10201

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.