The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Osteointegration of biomimetic apatite coating applied onto dense and porous metal implants in femurs of goats
Abstract
Biomimetic calcium phosphate (Ca‐P) coatings were applied onto dense titanium alloy (Ti6Al4V) and porous tantalum (Ta) cylinders by immersion into simulated body fluid at 37 °C and then at 50 °C for 24 h. As a result, a homogeneous bone‐like carbonated apatitic (BCA) coating, 30 μm thick was deposited on the entire surface of the dense and porous implants. Noncoated and BCA‐coated implants were press‐fit implanted in the femoral diaphysis of 14 adult female goats. Bone contact was measured after implantation for 6, 12, and 24 weeks, and investigated by histology and backscattered electron microscopy (BSEM). After 6 weeks, bone contact of the BCA‐coated Ti6Al4V implants was about 50%. After 12 and 24 weeks, bone contact was lower in comparison with the 6‐week implantations at, respectively 24 and 39%. Regarding the BCA‐coated porous Ta implants, bone contacts were 17, 30, and 18% after 6, 12, and 24 weeks, respectively. However, bone contact was always found significantly higher for BCA‐coated dense Ti6Al4V and porous Ta cylinders than the corresponding noncoated implants. The results of this study show that the BCA coating enhances the bone integration as compared to the noncoated implants. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 67B: 655–665, 2003
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solutions able to reproduce in vivo surface‐structure changes in bioactive glass‐ceramic A‐W3
Kokubo, T., Kushitani, H., Sakka, S., Kitsugi, T., & Yamamuro, T. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240607 · Cited by 3,836
Biomimetic Hydroxyapatite Coating on Metal Implants
Habibovic, P., Barrère, F., Van Blitterswijk, C. A., de Groot, K., & Layrolle, P. (2002) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.2002.tb00126.x · Cited by 548
Self-citationBonding of bone to apatite-coated implants
Geesink, R., de Groot, K., & Klein, C. (1988) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.70b1.2828374 · Cited by 537
Self-citationInfluence of ionic strength and carbonate on the Ca-P coating formation from SBF×5 solution
Barrere, F., van Blitterswijk, C. A., de Groot, K., & Layrolle, P. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00318-0 · Cited by 301
Self-citationOsteogenecity of octacalcium phosphate coatings applied on porous metal implants
Barrère, F., van der Valk, C. M., Dalmeijer, R. A. J., Meijer, G., van Blitterswijk, C. A., de Groot, K., & Layrolle, P. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10454 · Cited by 248
Self-citationBone biology. II: Formation, form, modeling, remodeling, and regulation of cell function.
Buckwalter, J. A., Glimcher, M. J., Cooper, R. R., & Recker, R. R. (1996) · PubMed · Cited by 239
Barrère, F., van der Valk, C. M., Dalmeijer, R. A. J., van Blitterswijk, C. A., de Groot, K., & Layrolle, P. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10291 · Cited by 200
Self-citationDhert, W. J. A., Klein, C. P. A. T., Jansen, J. A., van der Velde, E. A., Vriesde, R. C., Rozing, P. M., & de Groot, K. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270116 · Cited by 179
Self-citationOsteolysis from a press-fit hydroxyapatite-coated implant
Bloebaum, R. D., & Dupont, J. A. (1993) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(09)80013-2 · Cited by 164
Osteoclastic resorption of biomimetic calcium phosphate coatingsin vitro
Leeuwenburgh, S., Layrolle, P., Barr�re, F., de Bruijn, J., Schoonman, J., van Blitterswijk, C. A., & de Groot, K. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200108)56:2<208::aid-jbm1085>3.0.co;2-r · Cited by 161
Self-citation
Cited by
Surface treatments of titanium dental implants for rapid osseointegration
Le Guéhennec, L., Soueidan, A., Layrolle, P., & Amouriq, Y. (2007) · Dental Materials · doi:10.1016/j.dental.2006.06.025 · Cited by 2,406
Self-citationScaffold Design for Bone Regeneration
Polo-Corrales, L., Latorre-Esteves, M., & Ramirez-Vick, J. E. (2014) · Journal of Nanoscience and Nanotechnology · doi:10.1166/jnn.2014.9127 · Cited by 945
Biomaterial strategies for engineering implants for enhanced osseointegration and bone repair
Agarwal, R., & García, A. J. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.03.013 · Cited by 789
Engineering biocompatible implant surfaces
Bauer, S., Schmuki, P., von der Mark, K., & Park, J. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2012.09.001 · Cited by 780
Significance of calcium phosphate coatings for the enhancement of new bone osteogenesis – A review
Surmenev, R. A., Surmeneva, M. A., & Ivanova, A. A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.10.036 · Cited by 712
Effects of implant surface coatings and composition on bone integration: a systematic review
Junker, R., Dimakis, A., Thoneick, M., & Jansen, J. A. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01777.x · Cited by 535
Metallic Scaffolds for Bone Regeneration
Alvarez, K., & Nakajima, H. (2009) · Materials · doi:10.3390/ma2030790 · Cited by 505
Improving biocompatibility for next generation of metallic implants
Bandyopadhyay, A., Mitra, I., Goodman, S. B., Kumar, M., & Bose, S. (2023) · Progress in Materials Science · doi:10.1016/j.pmatsci.2022.101053 · Cited by 463
Current trends in dental implants
Gaviria, L., Salcido, J. P., Guda, T., & Ong, J. L. (2014) · Journal of the Korean Association of Oral and Maxillofacial Surgeons · doi:10.5125/jkaoms.2014.40.2.50 · Cited by 407
Organic–Inorganic Surface Modifications for Titanium Implant Surfaces
de Jonge, L. T., Leeuwenburgh, S. C. G., Wolke, J. G. C., & Jansen, J. A. (2008) · Pharmaceutical Research · doi:10.1007/s11095-008-9617-0 · Cited by 361
Advanced biomaterials for skeletal tissue regeneration: Instructive and smart functions
Barrère, F., Mahmood, T. A., de Groot, K., & van Blitterswijk, C. A. (2008) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2007.12.001 · Cited by 303
Self-citationSurface Engineering for Bone Implants: A Trend from Passive to Active Surfaces
Bosco, R., Van Den Beucken, J., Leeuwenburgh, S., & Jansen, J. (2012) · Coatings · doi:10.3390/coatings2030095 · Cited by 265
Metadata
- Authors
- Barrère, F., van der Valk, C. M., Meijer, G., Dalmeijer, R. A. J., de Groot, K., & Layrolle, P.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2003-09-12
- Volume
- 67B
- Issue
- 1
- Pages
- 655-665
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W2223724969
- Cited by
- 274
- References
- 13
- FWCI
- 4.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.