The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
In vitro biodegradation behavior, mechanical properties, and cytotoxicity of biodegradable Zn–Mg alloy
Open accessAbstract
Zinc–Magnesium (Zn–Mg) alloy as a novel biodegradable metal holds great potential in biodegradable implant applications as it is more corrosion resistant than Magnesium (Mg). However, the mechanical properties, biodegradation uniformity, and cytotoxicity of Zn–Mg alloy remained as concerns. In this study, hot extrusion process was applied to Zn–1 wt % Mg (Zn–1Mg) to refine its microstructure. Effects of hot extrusion on biodegradation behavior and mechanical properties of Zn–1Mg were investigated in comparison with Mg rare earth element alloy WE43. Metallurgical analysis revealed significant grain size reduction, and immersion test found that corrosion rates of WE43 and Zn–1Mg were reduced by 35% and 57%, respectively after extrusion. Moreover, hot extrusion resulted in a much more uniform biodegradation in extruded Zn–1Mg alloy and WE43. In vitro cytotoxicity test results indicated that Zn–1Mg alloy was biocompatible. Therefore, hot extruded Zn–1Mg with homogenous microstructure, uniform as well as slow degradation, improved mechanical properties, and good biocompatibility was believed to be an excellent candidate material for load‐bearing biodegradable implant application. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 103B: 1632–1640, 2015.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
IOP Conference Series: Materials Science and Engineering
(2022) · IOP Conference Series: Materials Science and Engineering · doi:10.1088/1757-899x/1231/1/011001 · Cited by 10,357
Magnesium and its alloys as orthopedic biomaterials: A review
Staiger, M. P., Pietak, A. M., Huadmai, J., & Dias, G. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.10.003 · Cited by 4,452
Solutions able to reproduce in vivo surface‐structure changes in bioactive glass‐ceramic A‐W3
Kokubo, T., Kushitani, H., Sakka, S., Kitsugi, T., & Yamamuro, T. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240607 · Cited by 3,836
Degradable biomaterials based on magnesium corrosion
Witte, F., Hort, N., Vogt, C., Cohen, S., Kainer, K. U., Willumeit, R., & Feyerabend, F. (2008) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2009.04.001 · Cited by 1,820
Zinc Exhibits Ideal Physiological Corrosion Behavior for Bioabsorbable Stents
Bowen, P. K., Drelich, J., & Goldman, J. (2013) · Advanced Materials · doi:10.1002/adma.201300226 · Cited by 928
Vojtěch, D., Kubásek, J., Šerák, J., & Novák, P. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.05.008 · Cited by 708
Progress and Challenge for Magnesium Alloys as Biomaterials
Zeng, R., Dietzel, W., Witte, F., Hort, N., & Blawert, C. (2008) · Advanced Engineering Materials · doi:10.1002/adem.200800035 · Cited by 680
Biodegradable Metals for Cardiovascular Stent Application: Interests and New Opportunities
Moravej, M., & Mantovani, D. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12074250 · Cited by 600
Windhagen, H., Radtke, K., Weizbauer, A., Diekmann, J., Noll, Y., Kreimeyer, U., Schavan, R., Stukenborg-Colsman, C., & Waizy, H. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-62 · Cited by 521
General and Localized Corrosion of Magnesium Alloys: A Critical Review
Ghali, E., Dietzel, W., & Kainer, K.-U. (2004) · Journal of Materials Engineering and Performance · doi:10.1361/10599490417533 · Cited by 476
Cited by
Venezuela, J., & Dargusch, M. S. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.01.035 · Cited by 588
Zinc-based alloys for degradable vascular stent applications
Mostaed, E., Sikora-Jasinska, M., Drelich, J. W., & Vedani, M. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.03.005 · Cited by 565
Antibacterial metals and alloys for potential biomedical implants
Zhang, E., Zhao, X., Hu, J., Wang, R., Fu, S., & Qin, G. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.01.030 · Cited by 552
Biodegradable Metals for Cardiovascular Stents: from Clinical Concerns to Recent Zn‐Alloys
Bowen, P. K., Shearier, E. R., Zhao, S., Guillory, R. J., Zhao, F., Goldman, J., & Drelich, J. W. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201501019 · Cited by 544
Mostaed, E., Sikora-Jasinska, M., Mostaed, A., Loffredo, S., Demir, A. G., Previtali, B., Mantovani, D., Beanland, R., & Vedani, M. (2016) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2016.03.018 · Cited by 475
Kabir, H., Munir, K., Wen, C., & Li, Y. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.09.013 · Cited by 397
Potential biodegradable Zn-Cu binary alloys developed for cardiovascular implant applications
Tang, Z., Niu, J., Huang, H., Zhang, H., Pei, J., Ou, J., & Yuan, G. (2017) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2017.05.013 · Cited by 361
Kubásek, J., Vojtěch, D., Jablonská, E., Pospíšilová, I., Lipov, J., & Ruml, T. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.08.015 · Cited by 360
The Prospects of Zinc as a Structural Material for Biodegradable Implants—A Review Paper
Katarivas Levy, G., Goldman, J., & Aghion, E. (2017) · Metals · doi:10.3390/met7100402 · Cited by 340
Current status and perspectives of zinc-based absorbable alloys for biomedical applications
Hernández-Escobar, D., Champagne, S., Yilmazer, H., Dikici, B., Boehlert, C. J., & Hermawan, H. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.07.034 · Cited by 309
Mei, D., Lamaka, S. V., Lu, X., & Zheludkevich, M. L. (2020) · Corrosion Science · doi:10.1016/j.corsci.2020.108722 · Cited by 284
Biodegradable metallic bone implants
Shuai, C., Li, S., Peng, S., Feng, P., Lai, Y., & Gao, C. (2019) · Materials Chemistry Frontiers · doi:10.1039/c8qm00507a · Cited by 275
Novel high-strength, low-alloys Zn-Mg (< 0.1 wt% Mg) and their arterial biodegradation
Jin, H., Zhao, S., Guillory, R., Bowen, P. K., Yin, Z., Griebel, A., Schaffer, J., Earley, E. J., Goldman, J., & Drelich, J. W. (2018) · Materials Science and Engineering: C · doi:10.1016/j.msec.2017.11.021 · Cited by 271
Updates on the research and development of absorbable metals for biomedical applications
Hermawan, H. (2018) · Progress in Biomaterials · doi:10.1007/s40204-018-0091-4 · Cited by 260
Kannan, M. B., Moore, C., Saptarshi, S., Somasundaram, S., Rahuma, M., & Lopata, A. L. (2017) · Scientific Reports · doi:10.1038/s41598-017-15873-w · Cited by 79
Metadata
- Authors
- Gong, H., Wang, K., Strich, R., & Zhou, J. G.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2015-01-08
- Volume
- 103
- Issue
- 8
- Pages
- 1632-1640
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W1588296206
- Cited by
- 264
- References
- 20
- FWCI
- 5.51
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.