The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Molecular sieving characteristics of the cultured endothelial monolayer
Abstract
We examined the selectivity of the bovine pulmonary artery endothelial monolayer in vitro to molecules of different sizes. The cultured bovine pulmonary endothelial monolayer was grown on a gelatinized filter and the transendothelial transport was studied by determining the permeability of molecules ranging from 182 to 340,000 daltons under diffusion conditions. The permeabilities across the cultured bovine endothelium were modeled according to cylindrical pore theory. The data were best fit by a two‐pore model with radii 65 Å and 304 Å and a ratio of small to large pores of 160:1. The results indicate that the cultured endothelial monolayer is a selective barrier to molecules of different sizes and that the molecular selectivity is consistent with a diffusional pathway through endothelial pore equivalents. The cultured endothelial monolayer is a useful system for studying the permeability characteristics of the endothelial barrier.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermodynamic analysis of the permeability of biological membranes to non-electrolytes
Kedem, O., & Katchalsky, A. (1958) · Biochimica et Biophysica Acta · doi:10.1016/0006-3002(58)90330-5 · Cited by 2,231
On the Absorption of Fluids from the Connective Tissue Spaces
Starling, E. H. (1896) · The Journal of Physiology · doi:10.1113/jphysiol.1896.sp000596 · Cited by 2,148
Parameter Estimation in Engineering and Science
de Oliveira, J. T., Beck, J. V., & Arnold, K. J. (1979) · International Statistical Review / Revue Internationale de Statistique · doi:10.2307/1403212 · Cited by 1,480
Filtration, diffusion, and molecular sieving through porous cellulose membranes.
Renkin, E. M. (1954) · PubMed Central · Cited by 1,084
Pappenheimer, J. R., Renkin, E. M., & Borrero, L. M. (1951) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1951.167.1.13 · Cited by 977
Parameter Estimation in Engineering and Science.
Folks, J. L., Beck, J. V., & Arnold, K. J. (1978) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2344460 · Cited by 610
Effects of unstirred layers on membrane phenomena.
Barry, P. H., & Diamond, J. M. (1984) · Physiological Reviews · doi:10.1152/physrev.1984.64.3.763 · Cited by 464
The chemotactic attraction of human fibroblasts to a lymphocyte-derived factor.
Postlethwaite, A. E., Snyderman, R., & Kang, A. H. (1976) · The Journal of experimental medicine · doi:10.1084/jem.144.5.1188 · Cited by 353
Passage of dextran molecules across the blood-lymph barrier.
Grotte, G. (1956) · PubMed · Cited by 353
Multiple pathways of capillary permeability.
Renkin, E. M. (1977) · Circulation Research · doi:10.1161/01.res.41.6.735 · Cited by 308
Cited by
Signaling Mechanisms Regulating Endothelial Permeability
Mehta, D., & Malik, A. B. (2006) · Physiological Reviews · doi:10.1152/physrev.00012.2005 · Cited by 1,720
Self-citationThe Hedgehog Pathway Promotes Blood-Brain Barrier Integrity and CNS Immune Quiescence
Alvarez, J. I., Dodelet-Devillers, A., Kebir, H., Ifergan, I., Fabre, P. J., Terouz, S., Sabbagh, M., Wosik, K., Bourbonnière, L., Bernard, M., et al. (2011) · Science · doi:10.1126/science.1206936 · Cited by 845
Transcytosis: Crossing Cellular Barriers
TUMA, P. L., & HUBBARD, A. L. (2003) · Physiological Reviews · doi:10.1152/physrev.00001.2003 · Cited by 681
The blood-brain barrier: an engineering perspective
Wong, A. D., Ye, M., Levy, A. F., Rothstein, J. D., Bergles, D. E., & Searson, P. C. (2013) · Frontiers in Neuroengineering · doi:10.3389/fneng.2013.00007 · Cited by 662
Komarova, Y. A., Kruse, K., Mehta, D., & Malik, A. B. (2017) · Circulation Research · doi:10.1161/circresaha.116.306534 · Cited by 503
Self-citationRegulation of vascular endothelial barrier function
Lum, H., & Malik, A. B. (1994) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.1994.267.3.l223 · Cited by 470
Self-citationKreuter, J., Ramge, P., Petrov, V., Hamm, S., Gelperina, S. E., Engelhardt, B., Alyautdin, R., von Briesen, H., & Begley, D. J. (2003) · Pharmaceutical Research · doi:10.1023/a:1022604120952 · Cited by 469
Gasche, Y., Fujimura, M., Morita-Fujimura, Y., Copin, J.-C., Kawase, M., Massengale, J., & Chan, P. H. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199909000-00010 · Cited by 400
Tiruppathi, C., Song, W., Bergenfeldt, M., Sass, P., & Malik, A. B. (1997) · Journal of Biological Chemistry · doi:10.1074/jbc.272.41.25968 · Cited by 391
Self-citationGasche, Y., Copin, J.-C., Sugawara, T., Fujimura, M., & Chan, P. H. (2001) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200112000-00003 · Cited by 390
In vitro model for evaluating drug transport across the blood–brain barrier
Cecchelli, R., Dehouck, B., Descamps, L., Fenart, L., Buée-Scherrer, V, Duhem, C., Lundquist, S., Rentfel, M., Torpier, G., & Dehouck, M. P. (1999) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(98)00083-0 · Cited by 383
Advanced Drug Delivery Systems of Curcumin for Cancer Chemoprevention
Bansal, S. S., Goel, M., Aqil, F., Vadhanam, M. V., & Gupta, R. C. (2011) · Cancer Prevention Research · doi:10.1158/1940-6207.capr-10-0006 · Cited by 353
A Stable and Reproducible Human Blood-Brain Barrier Model Derived from Hematopoietic Stem Cells
Cecchelli, R., Aday, S., Sevin, E., Almeida, C., Culot, M., Dehouck, L., Coisne, C., Engelhardt, B., Dehouck, M.-P., & Ferreira, L. (2014) · PLoS ONE · doi:10.1371/journal.pone.0099733 · Cited by 349
Drug Transfer Across the Blood‐Brain Barrier: Correlation Between In Vitro and In Vivo Models
Dehouck, M., Jolliet‐Riant, P., Brée, F., Fruchart, J., Cecchelli, R., & Tillement, J. (1992) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1992.tb10055.x · Cited by 286
Passing the Vascular Barrier: Endothelial Signaling Processes Controlling Extravasation
Wettschureck, N., Strilic, B., & Offermanns, S. (2019) · Physiological Reviews · doi:10.1152/physrev.00037.2018 · Cited by 286
Olivier, J.-C., Fenart, L., Chauvet, R., Pariat, C., Cecchelli, R., & Couet, W. (1999) · Pharmaceutical Research · doi:10.1023/a:1018947208597 · Cited by 213
Netrin 1 regulates blood–brain barrier function and neuroinflammation
Podjaski, C., Alvarez, J. I., Bourbonniere, L., Larouche, S., Terouz, S., Bin, J. M., Lécuyer, M.-A., Saint-Laurent, O., Larochelle, C., Darlington, P. J., et al. (2015) · Brain · doi:10.1093/brain/awv092 · Cited by 185
Antohe, F., Rădulescu, L., Gafencu, A., Gheţie, V., & Simionescu, M. (2001) · Human Immunology · doi:10.1016/s0198-8859(00)00244-5 · Cited by 175
Pinzón‐Daza, M., Garzón, R., Couraud, P., Romero, I., Weksler, B., Ghigo, D., Bosia, A., & Riganti, C. (2012) · British Journal of Pharmacology · doi:10.1111/j.1476-5381.2012.02103.x · Cited by 84
Use of the MicroSiM (µSiM) Barrier Tissue Platform for Modeling the Blood-Brain Barrier
McCloskey, M. C., Kasap, P., Trempel, M., Widom, L. P., Kuebel, J., Chen, K., Gaborski, T. R., Engelhardt, B., & McGrath, J. L. (2024) · Journal of Visualized Experiments · doi:10.3791/65258 · Cited by 8
Metadata
- Authors
- Siflinger‐Birnboim, A., del Vecchio, P. J., Cooper, J. A., Blumenstock, F. A., Shepard, J. M., & Malik, A. B.
- Venue
- Journal of Cellular Physiology
- Publisher
- Wiley
- Published
- 1987-07
- Volume
- 132
- Issue
- 1
- Pages
- 111-117
- ISSN
- 0021-9541 (ISSN-L)
- 1097-4652
- OpenAlex
- W2027568211
- Cited by
- 256
- References
- 22
- FWCI
- 2.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.