Comparison of t2 relaxation in blood, brain, and ferritin
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
T2 was measured in samples of human blood and monkey brain over a field range of 0.02–1.5 Tesla, with variable interecho times, and was compared with previous data on ferritin solutions (taken with the same apparatus). 1/T2 in deoxygenated blood increased quadratically with field strength, as noted previously, but in brain gray matter the increase was linear, as also was the case in ferritin solution. In both deoxygenated blood and gray matter, 1/T2 increased with interecho time, but appeared to level off at times around 50 msec, as expected from the theory of diffusion through magnetic gradients. Diffusion times estimated by using the chemical exchange approximation were 3.4 msec for deoxygenated blood and 5.7 msec for the globus pallidus. The quadratic field dependence in blood is consistent with this same theory, but the linear dependence in brain tissue and in ferritin solutions remains unexplained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transition metals, ferritin, glutathione, and ascorbic acid in parkinsonian brains
Riederer, P., Sofic, E., Rausch, W., Schmidt, B., Reynolds, G. P., Jellinger, K., & Youdim, M. B. H. (1989) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1989.tb09150.x · Cited by 1,383
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
DEXTER, D. T., CARAYON, A., JAVOY-AGID, F., AGID, Y., WELLS, F. R., DANIEL, S. E., LEES, A. J., JENNER, P., & MARSDEN, C. D. (1991) · Brain · doi:10.1093/brain/114.4.1953 · Cited by 1,043
Complex I, iron, and ferritin in Parkinson's disease substantia nigra
Mann, V. M., Cooper, J. M., Daniel, S. E., Srai, K., Jenner, P., Marsden, C. D., & Schapira, A. H. V. (1994) · Annals of Neurology · doi:10.1002/ana.410360612 · Cited by 251
Cited by
Magnetic Nanoparticles: Surface Effects and Properties Related to Biomedicine Applications
Issa, B., Obaidat, I., Albiss, B., & Haik, Y. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms141121266 · Cited by 1,245
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Gelman, N., Gorell, J. M., Barker, P. B., Savage, R. M., Spickler, E. M., Windham, J. P., & Knight, R. A. (1999) · Radiology · doi:10.1148/radiology.210.3.r99fe41759 · Cited by 373
Vymazal, J., Righini, A., Brooks, R. A., Canesi, M., Mariani, C., Leonardi, M., & Pezzoli, G. (1999) · Radiology · doi:10.1148/radiology.211.2.r99ma53489 · Cited by 342
Self-citationYe, F. Q., Mattay, V. S., Jezzard, P., Frank, J. A., Weinberger, D. R., & McLaughlin, A. C. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370215 · Cited by 294
On T2‐shortening by weakly magnetized particles: The chemical exchange model†
Brooks, R. A., Moiny, F., & Gillis, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1135 · Cited by 228
“[13] may be applied to any gradient system if G(2) is the average squared gradient within the accessible space and if the echo time is short enough to justify a secondorder expansion of the phase factor (6), remembering that the correlation lengths to be considered are those for the whole system, not just for the loca…”
BackgroundSelf-citationOn the theoretical basis of perfusion measurements by dynamic susceptibility contrast MRI
Kiselev, V. G. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1307 · Cited by 182
“[24], and then f5app(Dt) is found from Eq.”
BackgroundThe relation between brain iron and NMR relaxation times: An in vitro study
Vymazal, J., Brooks, R. A., Baumgarner, C., Tran, V., Katz, D., Bulte, J. W. M., Bauminger, E. R., & Chiro, G. D. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350108 · Cited by 172
Self-citationNMR relaxation in tissues with weak magnetic inhomogeneities
Jensen, J. H., & Chandra, R. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200007)44:1<144::aid-mrm21>3.0.co;2-o · Cited by 153
Iron imaging reveals tumor and metastasis macrophage hemosiderin deposits in breast cancer
Leftin, A., Ben-Chetrit, N., Klemm, F., Joyce, J. A., & Koutcher, J. A. (2017) · PLOS ONE · doi:10.1371/journal.pone.0184765 · Cited by 36
Leftin, A., Zhao, H., Turkekul, M., de Stanchina, E., Manova, K., & Koutcher, J. A. (2017) · Scientific Reports · doi:10.1038/s41598-017-11899-2 · Cited by 33
Metadata
- Authors
- Brooks, R. A., Vymazal, J., Baumgarner, C. D., Tran, V., & Bulte, J. W. M.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1995-07
- Volume
- 5
- Issue
- 4
- Pages
- 446-450
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2016071723
- Cited by
- 76
- References
- 4
- FWCI
- 5.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.