The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Modeling tracer kinetics in dynamic Gd‐DTPA MR imaging
Open accessAbstract
Three major models (from Tofts, Larsson, and Brix) for collecting and analyzing dynamic MRI gadolinium‐diethylenetriamine penta‐acetic acid (Gd‐DTPA) data are examined. All models use compartments representing the blood plasma and the abnormal extravascular extracellular space (EES), and they are intercompatible. All measure combinations of three parameters: (1) k psρ is the influx volume transfer constant (min−1), or permeability surface area product per unit volume of tissue, between plasma and EES; (2) v e is the volume of EES space per unit volume of tissue (0 < v e < 1); and (3) k ep, the efflux rate constant (min−1), is the ratio of the first two parameters (k ep = k psρ/v e). The ratio k ep is the simplest to measure, requiring only signal linearity with Gd tracer concentration or, alternatively, a measurement of T1 before injection of Gd (T 10). To measure the physiologic parameters k psρ and v e separately requires knowledge of T 10 and of the tissue relaxivity R 1 (≈︁ in vitro value).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Graphical Evaluation of Blood-to-Brain Transfer Constants from Multiple-Time Uptake Data
Patlak, C. S., Blasberg, R. G., & Fenstermacher, J. D. (1983) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1983.1 · Cited by 3,567
Tofts, P. S., & Kermode, A. G. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170208 · Cited by 1,456
Self-citationCrone, C. (1963) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1963.tb02652.x · Cited by 1,153
Passage of Molecules Through Capillary Walls
Pappenheimer, J. R. (1953) · Physiological Reviews · doi:10.1152/physrev.1953.33.3.387 · Cited by 954
Transport of potassium-42 from blood to tissue in isolated mammalian skeletal muscles
Renkin, E. M. (1959) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1959.197.6.1205 · Cited by 723
Pharmacokinetic Parameters in CNS Gd-DTPA Enhanced MR Imaging
Brix, G., Semmler, W., Port, R., Schad, L. R., Layer, G., & Lorenz, W. J. (1991) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199107000-00018 · Cited by 659
Mathematical Methods in the Physical Sciences
Boas, M. L., & Romain, J. E. (1967) · Physics Today · doi:10.1063/1.3034374 · Cited by 619
Pharmacokinetics of GdDTPA/dimeglumine after intravenous injection into healthy volunteers.
Weinmann, H., Laniado, M., & Mutzel, W. (1984) · PubMed · Cited by 462
Lower limits of cerebrovascular permeability to nonelectrolytes in the conscious rat
Ohno, K., Pettigrew, K. D., & Rapoport, S. I. (1978) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1978.235.3.h299 · Cited by 444
Larsson, H. B. W., Stubgaard, M., Frederiksen, J. L., Jensen, M., Henriksen, O., & Paulson, O. B. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160111 · Cited by 431
Quantitative Analysis of Dynamic Gd‐DTPA Enhancement in Breast Tumors Using a Permeability Model
Tofts, P. S., Berkowitz, B., & Schnall, M. D. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330416 · Cited by 399
Self-citationStudies of Gd‐DTPA relaxivity and proton exchange rates in tissue
Donahue, K. M., Burstein, D., Manning, W. J., & Gray, M. L. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320110 · Cited by 339
Cerebral blood flow: assessment with dynamic contrast-enhanced T2*-weighted MR imaging at 1.5 T.
Edelman, R. R., Mattle, H. P., Atkinson, D. J., Hill, T., Finn, J. P., Mayman, C., Ronthal, M., Hoogewoud, H. M., & Kleefield, J. (1990) · Radiology · doi:10.1148/radiology.176.1.2353094 · Cited by 304
Pharmacokinetic Mapping of the Breast: A New Method for Dynamic MR Mammography
Hoffmann, U., Brix, G., Knopp, M. V., Heβ, T., & Lorenz, W. J. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330408 · Cited by 303
Methods for quantifying the transport of drugs across brain barrier systems
Fenstermacher, J. D., Blasberg, R. G., & Patlak, C. S. (1981) · Pharmacology & Therapeutics · doi:10.1016/0163-7258(81)90062-0 · Cited by 214
Shames, D. M., Kuwatsuru, R., Vexler, V., Mühler, A., & Brasch, R. C. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290506 · Cited by 172
Flickinger, F. W., Allison, J. D., Sherry, R. M., & Wright, J. C. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90002-u · Cited by 148
Dynamic studies of gadolinium uptake in brain tumors using inversion‐recovery echo‐planar imaging
Gowland, P. A., Mansfield, P., Bullock, P. R., Stehling, M. K., Worthington, B. S., & Firth, J. L. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910260206 · Cited by 120
Simplified, noninvasive PET measurement of blood-brain barrier permeability.
Iannotti, F., Fieschi, C., Alfano, B., Picozzi, P., Mansi, L., Pozzilli, C., Punzo, A., del Vecchio, G., Lenzi, G. L., & Salvatore, M. (1987) · Journal of computer assisted tomography · doi:10.1097/00004728-198705000-00004 · Cited by 80
Larsson, H. B. W., & Tofts, P. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910240119 · Cited by 70
Self-citationSchwickert, H. C., Roberts, T. P. L., Shames, D. M., van Dijke, C. F., Disston, A. R., Mühler, A., Mann, J. S., & Brasch, R. C. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340609 · Cited by 69
Quantification of tissue plasma volume in the rat by contrast‐enhanced magnetic resonance imaging
Kuwatsuru, R., Shames, D. M., Mühler, A., Mintorovitch, J., Vexler, V. S., Mann, J. S., Cohn, F., Price, D., Huberty, J. P., & Brasch, R. C. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300112 · Cited by 64
Hackländer, T., Reichenbach, J. R., Hofer, M., & Mödder, U. (1996) · PubMed · Cited by 56
Tofts, P. (1996) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(96)00023-9 · Cited by 38
Self-citation
Cited by
Tofts, P. S., Brix, G., Buckley, D. L., Evelhoch, J. L., Henderson, E., Knopp, M. V., Larsson, H. B. W., Lee, T.-Y., Mayr, N. A., Parker, G. J. M., et al. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199909)10:3<223::aid-jmri2>3.0.co;2-s · Cited by 3,143
Self-citationLevin, V. A., Bidaut, L., Hou, P., Kumar, A. J., Wefel, J. S., Bekele, B. N., Prabhu, S., Loghin, M., Gilbert, M. R., & Jackson, E. F. (2011) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.12.061 · Cited by 729
Prostate Cancer: Multiparametric MR Imaging for Detection, Localization, and Staging
Hoeks, C. M. A., Barentsz, J. O., Hambrock, T., Yakar, D., Somford, D. M., Heijmink, S. W. T. P. J., Scheenen, T. W. J., Vos, P. C., Huisman, H., van Oort, I. M., et al. (2011) · Radiology · doi:10.1148/radiol.11091822 · Cited by 677
Parker, G. J. M., Roberts, C., Macdonald, A., Buonaccorsi, G. A., Cheung, S., Buckley, D. L., Jackson, A., Watson, Y., Davies, K., & Jayson, G. C. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21066 · Cited by 660
Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques
Calamante, F., Thomas, D. L., Pell, G. S., Wiersma, J., & Turner, R. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199907000-00001 · Cited by 638
Metadata
- Authors
- Tofts, P. S.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1997-01
- Volume
- 7
- Issue
- 1
- Pages
- 91-101
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2072626310
- Cited by
- 1,478
- References
- 24
- FWCI
- 18.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.