The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Principles of cerebral perfusion imaging by bolus tracking
Open accessAbstract
The principles of cerebral perfusion imaging by the method of dynamic susceptibility contrast magnetic resonance imaging (DSC‐MRI) (bolus tracking) are described. The MRI signals underlying DSC‐MRI are discussed. Tracer kinetics procedures are defined to calculate images of cerebral blood volume (CBV), cerebral blood flow (CBF), and mean transit time (MTT). Two general categories of numerical procedures are reviewed for deriving CBF from the residue function. Procedures that involve deconvolution, such as Fourier deconvolution or singular value decomposition (SVD), are classified as model‐independent methods because they do not require a model of the microvascular hemodynamics. Those methods in principle also yield a measure of the tissue impulse response function and the residue function, from which microvascular hemodynamics can be characterized. The second category of methods is the model‐dependent methods, which use models of tracer transport and retention in the microvasculature. These methods do not yield independent measures of the residue function and may introduce bias when the physiology does not follow the model. Statistical methods are sometimes used, which involve treating the residue function as a deconvolution kernel and optimizing (fitting) the kernel from the experimental data using procedures such as maximum likelihood. Finally, other hemodynamic indices that can be measured from DSC‐MRI data are described. J. Magn. Reson. Imaging 2005. © 2005 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Østergaard, L., Weisskoff, R. M., Chesler, D. A., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360510 · Cited by 1,512
Self-citationOn the Theory of the Indicator-Dilution Method for Measurement of Blood Flow and Volume
Meier, P., & Zierler, K. L. (1954) · Journal of Applied Physiology · doi:10.1152/jappl.1954.6.12.731 · Cited by 1,274
Crone, C. (1963) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1963.tb02652.x · Cited by 1,153
Perfusion imaging with NMR contrast agents
Rosen, B. R., Belliveau, J. W., Vevea, J. M., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140211 · Cited by 1,151
Mr contrast due to intravascular magnetic susceptibility perturbations
Boxerman, J. L., Hamberg, L. M., Rosen, B. R., & Weisskoff, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340412 · Cited by 1,008
Equations for Measuring Blood Flow by External Monitoring of Radioisotopes
ZIERLER, K. L. (1965) · Circulation Research · doi:10.1161/01.res.16.4.309 · Cited by 786
Microscopic susceptibility variation and transverse relaxation: Theory and experiment
Weisskoff, R., Zuo, C. S., Boxerman, J. L., & Rosen, B. R. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310605 · Cited by 715
Villringer, A., Rosen, B. R., Belliveau, J. W., Ackerman, J. L., Lauffer, R. B., Buxton, R. B., Chao, Y., Wedeenand, V. J., & Brady, T. J. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910060205 · Cited by 706
Rempp, K. A., Brix, G., Wenz, F., Becker, C. R., Gückel, F., & Lorenz, W. J. (1994) · Radiology · doi:10.1148/radiology.193.3.7972800 · Cited by 639
Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques
Calamante, F., Thomas, D. L., Pell, G. S., Wiersma, J., & Turner, R. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199907000-00001 · Cited by 638
Wu, O., Østergaard, L., Weisskoff, R. M., Benner, T., Rosen, B. R., & Sorensen, A. G. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10522 · Cited by 604
Self-citationIndicator Transit Time Considered as a Gamma Variate
THOMPSON, H. K., STARMER, C. F., WHALEN, R. E., & MCINTOSH, H. D. (1964) · Circulation Research · doi:10.1161/01.res.14.6.502 · Cited by 583
Theoretical Basis of Indicator-Dilution Methods For Measuring Flow and Volume
Zierler, K. L. (1962) · Circulation Research · doi:10.1161/01.res.10.3.393 · Cited by 510
Calamante, F., Gadian, D. G., & Connelly, A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200009)44:3<466::aid-mrm18>3.0.co;2-m · Cited by 458
Fisel, C. R., Ackerman, J. L., Buxton, R. B., Garrido, L., Belliveau, J. W., Rosen, B. R., & Brady, T. J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170206 · Cited by 356
Pitfalls in MR measurement of tissue blood flow with intravascular tracers: Which mean transit time?
Weisskoff, R. M., Chesler, D., Boxerman, J. L., & Rosen, B. R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290420 · Cited by 335
Susceptibility contrast imaging of cerebral blood volume: Human experience
Rosen, B. R., Belliveau, J. W., Aronen, H. J., Kennedy, D., Buchbinder, B. R., Fischman, A., Gruber, M., Glas, J., Weisskoff, R. M., Cohen, M. S., et al. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910220227 · Cited by 300
Contrast agents and cerebral hemodynamics
Rosen, B. R., Belliveau, J. W., Buchbinder, B. R., McKinstry, R. C., Porkka, L. M., Kennedy, D. N., Neuder, M. S., Fisel, C. R., Aronen, H. J., Kwong, K. K., et al. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910190216 · Cited by 290
Researches on the Circulation Time in Organs and on the Influences which affect it: Parts I.—III
Stewart, G. N. (1893) · The Journal of Physiology · doi:10.1113/jphysiol.1893.sp000462 · Cited by 275
Østergaard, L., Johannsen, P., Høst-Poulsen, P., Vestergaard-Poulsen, P., Asboe, H., Gee, A. D., Hansen, S. B., Cold, G. E., Gjedde, A., & Gyldensted, C. (1998) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199809000-00002 · Cited by 215
Self-citationKiselev, V. G., & Posse, S. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199903)41:3<499::aid-mrm12>3.0.co;2-o · Cited by 207
Østergaard, L., Smith, D. F., Vestergaard-Poulsen, P., Hansen, S., Gee, A. D., Gjedde, A., & Gyldensted, C. (1998) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199804000-00011 · Cited by 202
Self-citationShih, L. C., Saver, J. L., Alger, J. R., Starkman, S., Leary, M. C., Vinuela, F., Duckwiler, G., Gobin, Y. P., Jahan, R., Villablanca, J. P., et al. (2003) · Stroke · doi:10.1161/01.str.0000072998.70087.e9 · Cited by 195
On the theoretical basis of perfusion measurements by dynamic susceptibility contrast MRI
Kiselev, V. G. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1307 · Cited by 182
Wirestam, R., Knutsson, L., Østergaard, L., Bolling, M., Aunola, J.-P., Lindgren, A. G., Geijer, B., Holt�s, S., & St�hlberg, F. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200005)43:5<691::aid-mrm11>3.0.co;2-b · Cited by 165
Self-citationModeling Cerebral Blood Flow and Flow Heterogeneity from Magnetic Resonance Residue Data
Østergaard, L., Chesler, D. A., Weisskoff, R. M., Sorensen, A. G., & Rosen, B. R. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199906000-00013 · Cited by 140
Self-citationSchreiber, W., Gückel, F., Stritzke, P., Schmiedek, P., Schwartz, A., & Brix, G. (1998) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199810000-00011 · Cited by 122
Analytical Theory of Susceptibility Induced NMR Signal Dephasing in a Cerebrovascular Network
Kiselev, V. G., & Posse, S. (1998) · Physical Review Letters · doi:10.1103/physrevlett.81.5696 · Cited by 97
Modeling blood flow heterogeneity
King, R. B., Raymond, G. M., & Bassingthwaighte, J. B. (1996) · Annals of Biomedical Engineering · doi:10.1007/bf02660885 · Cited by 94
Maximum likelihood estimation of cerebral blood flow in dynamic susceptibility contrast MRI
Vonken, E.-J. P. A., Beekman, F. J., Bakker, C. J. G., & Viergever, M. A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199902)41:2<343::aid-mrm19>3.0.co;2-t · Cited by 89
Simonsen, C. Z., ��stergaard, L., Vestergaard‐Poulsen, P., Røhl, L., Bj�rnerud, A., & Gyldensted, C. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199902)9:2<342::aid-jmri29>3.0.co;2-b · Cited by 86
Self-citationLassen, N. A. (1984) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1984.90 · Cited by 77
Perfusion quantification using Gaussian process deconvolution
Andersen, I. K., Szymkowiak, A., Rasmussen, C. E., Hanson, L. G., Marstrand, J. R., Larsson, H. B. W., & Hansen, L. K. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10213 · Cited by 77
Regulation of renin processing and secretion: chemiosmotic control and novel secretory pathway
King, J. A., Lush, D. J., & Fray, J. C. (1993) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1993.265.2.c305 · Cited by 51
Diffusion tensor mapping of the human brain using single-shot line scan imaging
Finsterbusch, J., & Frahm, J. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200009)12:3<400::aid-jmri5>3.0.co;2-c · Cited by 15
Cited by
Chertok, B., Moffat, B. A., David, A. E., Yu, F., Bergemann, C., Ross, B. D., & Yang, V. C. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.08.050 · Cited by 900
Weinstein, J. S., Varallyay, C. G., Dosa, E., Gahramanov, S., Hamilton, B., Rooney, W. D., Muldoon, L. L., & Neuwelt, E. A. (2010) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2009.192 · Cited by 500
Fantini, S., Sassaroli, A., Tgavalekos, K. T., & Kornbluth, J. (2016) · Neurophotonics · doi:10.1117/1.nph.3.3.031411 · Cited by 397
Perfusion MRI: The Five Most Frequently Asked Technical Questions
Essig, M., Shiroishi, M. S., Nguyen, T. B., Saake, M., Provenzale, J. M., Enterline, D., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9543 · Cited by 366
Tracer kinetic modelling in MRI: estimating perfusion and capillary permeability
Sourbron, S. P., & Buckley, D. L. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/2/r1 · Cited by 361
Metadata
- Authors
- Østergaard, L.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2005-10-31
- Volume
- 22
- Issue
- 6
- Pages
- 710-717
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2019865884
- Cited by
- 289
- References
- 36
- FWCI
- 5.71
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.