The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Pitfalls in MR measurement of tissue blood flow with intravascular tracers: Which mean transit time?
Abstract
Measuring tissue blood flow with NMR imaging of intravascular tracers is more difficult than measurements of tissue blood volume. One major obstacle to the application of the Central Volume Principle is the direct measurement of the mean transit time. In this note, we demonstrate that mean transit time (MTT), which relates tissue blood volume to blood flow via the Central Volume Principle, is not the first moment of the concentration‐time curve for MR or CT imaging of purely intravascular tracers. However, while first moment methods cannot be used by themselves to determine absolute flow, we show that transit curves may provide a useful relative measure of flow, for example, by considering ratios of the first moments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Self-citationOn the Theory of the Indicator-Dilution Method for Measurement of Blood Flow and Volume
Meier, P., & Zierler, K. L. (1954) · Journal of Applied Physiology · doi:10.1152/jappl.1954.6.12.731 · Cited by 1,274
Equations for Measuring Blood Flow by External Monitoring of Radioisotopes
ZIERLER, K. L. (1965) · Circulation Research · doi:10.1161/01.res.16.4.309 · Cited by 786
Cerebral blood flow determination by rapid-sequence computed tomography: theoretical analysis.
Axel, L. (1980) · Radiology · doi:10.1148/radiology.137.3.7003648 · Cited by 625
Indicator Transit Time Considered as a Gamma Variate
THOMPSON, H. K., STARMER, C. F., WHALEN, R. E., & MCINTOSH, H. D. (1964) · Circulation Research · doi:10.1161/01.res.14.6.502 · Cited by 583
Functional cerebral imaging by susceptibility‐contrast NMR
Belliveau, J. W., Rosen, B. R., Kantor, H. L., Rzedzian, R. R., Kennedy, D. N., McKinstry, R. C., Vevea, J. M., Cohen, M. S., Pykett, I. L., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140311 · Cited by 570
Self-citationTracer kinetic methods in medical physiology
Lassen, N. A., & Perl, W. (1979) · Raven Press eBooks · Cited by 495
Fisel, C. R., Ackerman, J. L., Buxton, R. B., Garrido, L., Belliveau, J. W., Rosen, B. R., & Brady, T. J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170206 · Cited by 356
Self-citationCerebral blood flow: assessment with dynamic contrast-enhanced T2*-weighted MR imaging at 1.5 T.
Edelman, R. R., Mattle, H. P., Atkinson, D. J., Hill, T., Finn, J. P., Mayman, C., Ronthal, M., Hoogewoud, H. M., & Kleefield, J. (1990) · Radiology · doi:10.1148/radiology.176.1.2353094 · Cited by 304
Contrast agents and cerebral hemodynamics
Rosen, B. R., Belliveau, J. W., Buchbinder, B. R., McKinstry, R. C., Porkka, L. M., Kennedy, D. N., Neuder, M. S., Fisel, C. R., Aronen, H. J., Kwong, K. K., et al. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910190216 · Cited by 290
Self-citation
Cited by
Østergaard, L., Weisskoff, R. M., Chesler, D. A., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360510 · Cited by 1,512
Self-citationMr contrast due to intravascular magnetic susceptibility perturbations
Boxerman, J. L., Hamberg, L. M., Rosen, B. R., & Weisskoff, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340412 · Cited by 1,008
Self-citationAlsop, D. C., & Detre, J. A. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199611000-00019 · Cited by 754
The ischemic penumbra: Operationally defined by diffusion and perfusion MRI
Schlaug, G., Benfield, A., Baird, A. E., Siewert, B., Lövblad, K. O., Parker, R. A., Edelman, R. R., & Warach, S. (1999) · Neurology · doi:10.1212/wnl.53.7.1528 · Cited by 663
Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques
Calamante, F., Thomas, D. L., Pell, G. S., Wiersma, J., & Turner, R. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199907000-00001 · Cited by 638
Metadata
- Authors
- Weisskoff, R. M., Chesler, D., Boxerman, J. L., & Rosen, B. R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1993-04
- Volume
- 29
- Issue
- 4
- Pages
- 553-558
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1974774291
- Cited by
- 335
- References
- 16
- FWCI
- 14.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pitfalls in MR measurement of tissue blood flow with intravascular tracers: Which mean transit time? https://app.cochat.ai/papers/10.1002/mrm.1910290420
- The paper
- Weisskoff, R. M., Chesler, D., Boxerman, J. L., & Rosen, B. R. (1993). Pitfalls in MR measurement of tissue blood flow with intravascular tracers: Which mean transit time? Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910290420
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.