The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Multiecho reconstruction for simultaneous water‐fat decomposition and T2* estimation
Open accessAbstract
Purpose: To describe and demonstrate the feasibility of a novel multiecho reconstruction technique that achieves simultaneous water‐fat decomposition and T2* estimation. The method removes interference of water‐fat separation with iron‐induced T2* effects and therefore has potential for the simultaneous characterization of hepatic steatosis (fatty infiltration) and iron overload. Materials and Methods: The algorithm called “T2*‐IDEAL” is based on the IDEAL water‐fat decomposition method. A novel “complex field map” construct is used to estimate both R2* (1/T2*) and local B 0 field inhomogeneities using an iterative least‐squares estimation method. Water and fat are then decomposed from source images that are corrected for both T2* and B 0 field inhomogeneity. Results: It was found that a six‐echo multiecho acquisition using the shortest possible echo times achieves an excellent balance of short scan and reliable R2* measurement. Phantom experiments demonstrate the feasibility with high accuracy in R2* measurement. Promising preliminary in vivo results are also shown. Conclusion: The T2*‐IDEAL technique has potential applications in imaging of diffuse liver disease for evaluation of both hepatic steatosis and iron overload in a single breath‐hold. J. Magn. Reson. Imaging 2007;26:1153–1161. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276
Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload
Anderson, L. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2822 · Cited by 1,682
Wood, J. C., Enriquez, C., Ghugre, N., Tyzka, J. M., Carson, S., Nelson, M. D., & Coates, T. D. (2005) · Blood · doi:10.1182/blood-2004-10-3982 · Cited by 1,045
Reeder, S. B., Pineda, A. R., Wen, Z., Shimakawa, A., Yu, H., Brittain, J. H., Gold, G. E., Beaulieu, C. H., & Pelc, N. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20624 · Cited by 706
Self-citationThree‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction
Glover, G. H., & Schneider, E. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180211 · Cited by 687
Non-invasive assessment of hepatic iron stores by MRI
Gandon, Y., Olivié, D., Guyader, D., Aubé, C., Oberti, F., Sebille, V, & Deugnier, Y. (2004) · The Lancet · doi:10.1016/s0140-6736(04)15436-6 · Cited by 671
George, D. K., Goldwurm, S., Macdonald, G. A., Cowley, L. L., Walker, N. I., Ward, P. J., Jazwinska, E. C., & Powell, L. W. (1998) · Gastroenterology · doi:10.1016/s0016-5085(98)70482-2 · Cited by 659
Multicoil Dixon chemical species separation with an iterative least‐squares estimation method
Reeder, S. B., Wen, Z., Yu, H., Pineda, A. R., Gold, G. E., Markl, M., & Pelc, N. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10675 · Cited by 508
Self-citationBugianesi, E., Manzini, P., D'Antico, S., Vanni, E., Longo, F., Leone, N., Massarenti, P., Piga, A., Marchesini, G., & Rizzetto, M. (2004) · Hepatology · doi:10.1002/hep.20023 · Cited by 440
Multipoint dixon technique for water and fat proton and susceptibility imaging
Glover, G. H. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010504 · Cited by 405
Westwood, M., Anderson, L. J., Firmin, D. N., Gatehouse, P. D., Charrier, C. C., Wonke, B., & Pennell, D. J. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10332 · Cited by 379
Bonkovsky, H. L., Jawaid, Q., Tortorelli, K., LeClair, P., Cobb, J., Lambrecht, R. W., & Banner, B. F. (1999) · Journal of Hepatology · doi:10.1016/s0168-8278(99)80032-4 · Cited by 360
Quantification of liver fat using magnetic resonance spectroscopy
Thomsen, C., Becker, U., Winkler, K., Christoffersen, P., Jensen, M., & Henriksen, O. (1994) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)92543-7 · Cited by 332
Update on Nonalcoholic Fatty Liver Disease
McCullough, A. J. (2002) · Journal of Clinical Gastroenterology · doi:10.1097/00004836-200203000-00013 · Cited by 315
Hepatic Fat Fraction: MR Imaging for Quantitative Measurement and Display—Early Experience
Hussain, H. K., Chenevert, T. L., Londy, F. J., Gulani, V., Swanson, S. D., McKenna, B. J., Appelman, H. D., Adusumilli, S., Greenson, J. K., & Conjeevaram, H. S. (2005) · Radiology · doi:10.1148/radiol.2373041639 · Cited by 277
Chitturi, S., Weltman, M., Farrell, G. C., McDonald, D., Liddle, C., Samarasinghe, D., Lin, R., Abeygunasekera, S., & George, J. (2002) · Hepatology · doi:10.1053/jhep.2002.33892 · Cited by 247
Hemochromatosis: diagnosis and quantification of liver iron with gradient-echo MR imaging.
Gandon, Y., Guyader, D., Heautot, J. F., Reda, M. I., Yaouanq, J., Buhé, T., Brissot, P., Carsin, M., & Deugnier, Y. (1994) · Radiology · doi:10.1148/radiology.193.2.7972774 · Cited by 225
Cramér–Rao bounds for three‐point decomposition of water and fat
Pineda, A. R., Reeder, S. B., Wen, Z., & Pelc, N. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20623 · Cited by 215
Self-citationLiver Fat: Effect of Hepatic Iron Deposition on Evaluation with Opposed-Phase MR Imaging
Westphalen, A. C. A., Qayyum, A., Yeh, B. M., Merriman, R. B., Lee, J. A., Lamba, A., Lu, Y., & Coakley, F. V. (2007) · Radiology · doi:10.1148/radiol.2422052024 · Cited by 165
Single spin‐echo proton transverse relaxometry of iron‐loaded liver
Pierre, T. G. S., Clark, P. R., & Chua‐anusorn, W. (2004) · NMR in Biomedicine · doi:10.1002/nbm.905 · Cited by 125
Interaction of iron, insulin resistance, and nonalcoholic steatohepatitis
Chitturi, S., & George, J. (2003) · Current Gastroenterology Reports · doi:10.1007/s11894-003-0005-y · Cited by 88
Fatty infiltration of the liver
Pilleul, F., Chave, G., Dumortier, J., Scoazec, J., & Valette, P. (2005) · Gastroentérologie Clinique et Biologique · doi:10.1016/s0399-8320(05)82179-7 · Cited by 56
Cited by
Quantitative assessment of liver fat with magnetic resonance imaging and spectroscopy
Reeder, S. B., Cruite, I., Hamilton, G., & Sirlin, C. B. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22580 · Cited by 822
Self-citationYu, H., Shimakawa, A., McKenzie, C. A., Brodsky, E., Brittain, J. H., & Reeder, S. B. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21737 · Cited by 694
Self-citationDixon techniques for water and fat imaging
Ma, J. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21492 · Cited by 610
Noninvasive, Quantitative Assessment of Liver Fat by MRI‐PDFF as an Endpoint in NASH Trials
Caussy, C., Reeder, S. B., Sirlin, C. B., & Loomba, R. (2018) · Hepatology · doi:10.1002/hep.29797 · Cited by 563
Self-citationNoureddin, M., Lam, J., Peterson, M. R., Middleton, M., Hamilton, G., Le, T.-A., Bettencourt, R., Changchien, C., Brenner, D. A., Sirlin, C., et al. (2013) · Hepatology · doi:10.1002/hep.26455 · Cited by 550
Metadata
- Authors
- Yu, H., McKenzie, C. A., Shimakawa, A., Vu, A. T., Brau, A. C. S., Beatty, P. J., Pineda, A. R., Brittain, J. H., & Reeder, S. B.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2007-09-25
- Volume
- 26
- Issue
- 4
- Pages
- 1153-1161
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2076910504
- Cited by
- 437
- References
- 22
- FWCI
- 14.14
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.