The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Parallel MR imaging
Open accessAbstract
Parallel imaging is a robust method for accelerating the acquisition of magnetic resonance imaging (MRI) data, and has made possible many new applications of MR imaging. Parallel imaging works by acquiring a reduced amount of k‐space data with an array of receiver coils. These undersampled data can be acquired more quickly, but the undersampling leads to aliased images. One of several parallel imaging algorithms can then be used to reconstruct artifact‐free images from either the aliased images (SENSE‐type reconstruction) or from the undersampled data (GRAPPA‐type reconstruction). The advantages of parallel imaging in a clinical setting include faster image acquisition, which can be used, for instance, to shorten breath‐hold times resulting in fewer motion‐corrupted examinations. In this article the basic concepts behind parallel imaging are introduced. The relationship between undersampling and aliasing is discussed and two commonly used parallel imaging methods, SENSE and GRAPPA, are explained in detail. Examples of artifacts arising from parallel imaging are shown and ways to detect and mitigate these artifacts are described. Finally, several current applications of parallel imaging are presented and recent advancements and promising research in parallel imaging are briefly reviewed. J. Magn. Reson. Imaging 2012;36:55–72. © 2012 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Self-citationRoemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322
Advances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211
Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging
Pipe, J. G. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<963::aid-mrm17>3.0.co;2-l · Cited by 928
k‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
Tsao, J., Boesiger, P., & Pruessmann, K. P. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10611 · Cited by 794
Breuer, F. A., Blaimer, M., Heidemann, R. M., Mueller, M. F., Griswold, M. A., & Jakob, P. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20401 · Cited by 633
Self-citationMarkl, M., Kilner, P. J., & Ebbers, T. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-7 · Cited by 463
Real‐time MRI at a resolution of 20 ms
Uecker, M., Zhang, S., Voit, D., Karaus, A., Merboldt, K., & Frahm, J. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1585 · Cited by 434
Controlled aliasing in volumetric parallel imaging (2D CAIPIRINHA)
Breuer, F. A., Blaimer, M., Mueller, M. F., Seiberlich, N., Heidemann, R. M., Griswold, M. A., & Jakob, P. M. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20787 · Cited by 413
Self-citationPartially parallel imaging with localized sensitivities (PILS)
Griswold, M. A., Jakob, P. M., Nittka, M., Goldfarb, J. W., & Haase, A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200010)44:4<602::aid-mrm14>3.0.co;2-5 · Cited by 329
Self-citation96‐Channel receive‐only head coil for 3 Tesla: Design optimization and evaluation
Wiggins, G. C., Polimeni, J. R., Potthast, A., Schmitt, M., Alagappan, V., & Wald, L. L. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22028 · Cited by 274
Parallel imaging reconstruction using automatic regularization
Lin, F., Kwong, K. K., Belliveau, J. W., & Wald, L. L. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10718 · Cited by 266
General formulation for quantitative G‐factor calculation in GRAPPA reconstructions
Breuer, F. A., Kannengiesser, S. A. R., Blaimer, M., Seiberlich, N., Jakob, P. M., & Griswold, M. A. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22066 · Cited by 218
Self-citationVolume imaging with MR phased arrays
Hayes, C. E., Hattes, N., & Roemer, P. B. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180206 · Cited by 178
Sensory stimulation by time‐varying magnetic fields
Cohen, M. S., Weisskoff, R. M., Rzedzian, R. R., et al. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140226 · Cited by 151
Field‐of‐view limitations in parallel imaging
Griswold, M. A., Kannengießer, S., Heidemann, R. M., et al. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20249 · Cited by 146
Self-citationPeripheral nerve stimulation during MRI: Effects of high gradient amplitudes and switching rates
Ham, C. L. G., Engels, J. M. L., van de Wiel, G. T., & Machielsen, A. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070524 · Cited by 129
Paschal, C. B., & Morris, H. D. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10451 · Cited by 107
Improved radial GRAPPA calibration for real‐time free‐breathing cardiac imaging
Seiberlich, N., Ehses, P., Duerk, J. L., Gilkeson, R., & Griswold, M. A. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22618 · Cited by 105
Self-citationDirect parallel image reconstructions for spiral trajectories using GRAPPA
Heidemann, R. M., Griswold, M. A., Seiberlich, N., Krüger, G., Kannengießer, S., Kiefer, B., Wiggins, G. C., Wald, L. L., & Jakob, P. M. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20951 · Cited by 95
Self-citationKoike, N., Cho, A., Nasu, K., Seto, K., Nagaya, S., Ohshima, Y., & Ohkohchi, N. (2009) · World Journal of Gastroenterology · doi:10.3748/wjg.15.5805 · Cited by 86
Lin, F., Chen, Y., Belliveau, J. W., et al. (2003) · Human Brain Mapping · doi:10.1002/hbm.10109 · Cited by 82
Gardener, A. G., & Francis, S. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22387 · Cited by 71
Cardiac MRI in Ischemic Heart Disease
Ishida, M., Kato, S., & Sakuma, H. (2009) · Circulation Journal · doi:10.1253/circj.cj-09-0524 · Cited by 68
Hayat, T. T. A., Nihat, A., Martínez-Biarge, M., McGuinness, A., Allsop, J. M., Hajnal, J. V., & Rutherford, M. (2010) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2295 · Cited by 58
Saam, T., Raya, J. G., Cyran, C. C., Bochmann, K., Meimarakis, G., Dietrich, O., Clevert, D., Frey, U., Yuan, C., Hatsukami, T. S., et al. (2009) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-11-41 · Cited by 56
Plathow, C., Schöebinger, M., Fink, C., Hof, H., Debus, J., Meinzer, H.-P., & Kauczor, H. (2006) · Radiology · doi:10.1148/radiol.2401050727 · Cited by 50
Quantitative BOLD: The effect of diffusion
Dickson, J. D., Ash, T., Williams, G. B., et al. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22151 · Cited by 41
Clinical Feasibility of Accelerated, High Spatial Resolution Myocardial Perfusion Imaging
Manka, R., Vitanis, V., Boesiger, P., Flammer, A. J., Plein, S., & Kozerke, S. (2010) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2010.03.009 · Cited by 39
High temporal resolution SSFP cine MRI for estimation of left ventricular diastolic parameters
Krishnamurthy, R., Pednekar, A. S., Cheong, B., & Muthupillai, R. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22123 · Cited by 32
Spatial variation inT1of healthy human articular cartilage of the knee joint
Wiener, E., Pfirrmann, C. W. A., & Hodler, J. (2010) · British Journal of Radiology · doi:10.1259/bjr/62779246 · Cited by 31
Improvements in parallel imaging accelerated functional MRI using multiecho echo-planar imaging
Schmiedeskamp, H., Newbould, R. D., Pisani, L. J., Skare, S. T., Glover, G. H., Pruessmann, K. P., & Bammer, R. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22222 · Cited by 30
Lum, D. P., Busse, R. F., François, C. J., Brau, A. C. S., Beatty, P. J., Huff, J., Brittain, J. H., & Reeder, S. B. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21964 · Cited by 30
In vivo structural analysis of articular cartilage using diffusion tensor magnetic resonance imaging
Azuma, T., Nakai, R., Takizawa, O., & Tsutsumi, S. (2009) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2009.05.012 · Cited by 27
BOLD fMRI using a modified HASTE sequence
Ye, Y., Zhuo, Y., Xue, R., & Zhou, X. J. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.07.044 · Cited by 20
Ultrafast bold fMRI using single-shot spin-echo echo planar imaging
Boujraf, S., Summers, P. E., Belahsen, F., Prüssmann, K. P., & Kollias, S. (2009) · Journal of Medical Physics · doi:10.4103/0971-6203.48719 · Cited by 18
Lindholm, T. L., Botes, L., Engman, E.-L., Frank, A., Jonsson, T., Svensson, L., & Julin, P. (2009) · BMC Medical Imaging · doi:10.1186/1471-2342-9-15 · Cited by 16
Fellner, C., Doenitz, C., Finkenzeller, T., Jung, E. M., Rennert, J., & Schlaier, J. R. (2009) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-2009-1222 · Cited by 15
Accuracy of accelerated cine MR imaging at 3 Tesla in longitudinal follow-up of cardiac function
Sandner, T. A., Houck, P. D., Runge, V. M., Sincleair, S. T., Huber, A. M. A., Theisen, D., Reiser, M. F., & Wintersperger, B. J. (2008) · European Radiology · doi:10.1007/s00330-008-0993-y · Cited by 13
Yu, J., Schär, M., Vonken, E.-J. P. A., Kelle, S., & Stuber, M. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22114 · Cited by 12
Independent slab‐phase modulation combined with parallel imaging in bilateral breast MRI
Han, M., Beatty, P. J., Daniel, B. L., et al. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22115 · Cited by 7
Breathheld autocalibrated phase‐contrast imaging
Lew, C., Alley, M. T., Spielman, D. M., Bammer, R., & Chan, F. P. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22127 · Cited by 4
Grieve (2000) · doi:10.1002/(sici)1522-2594(200005)43:5
Cited by
Yang, G., Yu, S., Dong, H., Slabaugh, G., Dragotti, P. L., Ye, X., Liu, F., Arridge, S., Keegan, J., Guo, Y., et al. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2785879 · Cited by 1,081
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Score-based diffusion models for accelerated MRI
Chung, H., & Ye, J. C. (2022) · Medical Image Analysis · doi:10.1016/j.media.2022.102479 · Cited by 421
Carlier, P. G., Marty, B., Scheidegger, O., Loureiro de Sousa, P., Baudin, P.-Y., Snezhko, E., & Vlodavets, D. (2016) · Journal of Neuromuscular Diseases · doi:10.3233/jnd-160145 · Cited by 186
Rapid Musculoskeletal MRI in 2021: Clinical Application of Advanced Accelerated Techniques
Fritz, J., Guggenberger, R., & Grande, F. D. (2021) · American Journal of Roentgenology · doi:10.2214/ajr.20.22902 · Cited by 121
Metadata
- Authors
- Deshmane, A., Gulani, V., Griswold, M. A., & Seiberlich, N.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2012-06-13
- Volume
- 36
- Issue
- 1
- Pages
- 55-72
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2014547837
- Cited by
- 606
- References
- 44
- FWCI
- 12.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.