The DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.
Ion mobility–mass spectrometry
Abstract
This review article compares and contrasts various types of ion mobility–mass spectrometers available today and describes their advantages for application to a wide range of analytes. Ion mobility spectrometry (IMS), when coupled with mass spectrometry, offers value‐added data not possible from mass spectra alone. Separation of isomers, isobars, and conformers; reduction of chemical noise; and measurement of ion size are possible with the addition of ion mobility cells to mass spectrometers. In addition, structurally similar ions and ions of the same charge state can be separated into families of ions which appear along a unique mass‐mobility correlation line. This review describes the four methods of ion mobility separation currently used with mass spectrometry. They are (1) drift‐time ion mobility spectrometry (DTIMS), (2) aspiration ion mobility spectrometry (AIMS), (3) differential‐mobility spectrometry (DMS) which is also called field‐asymmetric waveform ion mobility spectrometry (FAIMS) and (4) traveling‐wave ion mobility spectrometry (TWIMS). DTIMS provides the highest IMS resolving power and is the only IMS method which can directly measure collision cross‐sections. AIMS is a low resolution mobility separation method but can monitor ions in a continuous manner. DMS and FAIMS offer continuous‐ion monitoring capability as well as orthogonal ion mobility separation in which high‐separation selectivity can be achieved. TWIMS is a novel method of IMS with a low resolving power but has good sensitivity and is well intergrated into a commercial mass spectrometer. One hundred and sixty references on ion mobility–mass spectrometry (IMMS) are provided. Copyright © 2008 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pringle, S. D., Giles, K., Wildgoose, J. L., Williams, J. P., Slade, S. E., Thalassinos, K., Bateman, R. H., Bowers, M. T., & Scrivens, J. H. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.07.021 · Cited by 808
Ewing, R. (2001) · Talanta · doi:10.1016/s0039-9140(00)00565-8 · Cited by 772
Theory of plasma chromatography/gaseous electrophoresis. Review
Revercomb, H. E., & Mason, E. A. (1975) · Analytical Chemistry · doi:10.1021/ac60357a043 · Cited by 755
Applications of a travelling wave‐based radio‐frequency‐only stacked ring ion guide
Giles, K., Pringle, S. D., Worthington, K. R., Little, D., Wildgoose, J. L., & Bateman, R. H. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1641 · Cited by 727
Evidence for Macromolecular Protein Rings in the Absence of Bulk Water
Ruotolo, B. T., Giles, K., Campuzano, I., Sandercock, A. M., Bateman, R. H., & Robinson, C. V. (2005) · Science · doi:10.1126/science.1120177 · Cited by 596
Carbon cluster cations with up to 84 atoms: structures, formation mechanism, and reactivity
von Helden, G., Hsu, M. T., Gotts, N., & Bowers, M. T. (1993) · The Journal of Physical Chemistry · doi:10.1021/j100133a011 · Cited by 593
Eiceman, G. A., & Karpas, Z. (2005) · CRC Press eBooks · doi:10.1201/9781420038972 · Cited by 569
Naked Protein Conformations: Cytochrome c in the Gas Phase
Clemmer, D. E., Hudgins, R. R., & Jarrold, M. F. (1995) · Journal of the American Chemical Society · doi:10.1021/ja00145a037 · Cited by 491
Buryakov, I. A., Krylov, E. V., Nazarov, E. G., & Rasulev, U. K. (1993) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(93)87062-w · Cited by 444
High-field asymmetric waveform ion mobility spectrometry: A new tool for mass spectrometry
Guevremont, R. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.08.119 · Cited by 444
von Helden, G., Gotts, N. G., & Bowers, M. T. (1993) · Nature · doi:10.1038/363060a0 · Cited by 423
Ion Mobility Spectrometry: Principles and Applications
Borsdorf, H., & Eiceman, G. A. (2006) · Applied Spectroscopy Reviews · doi:10.1080/05704920600663469 · Cited by 395
Silicon cluster ions: Evidence for a structural transition
Jarrold, M. F., & Constant, V. A. (1991) · Physical Review Letters · doi:10.1103/physrevlett.67.2994 · Cited by 380
Plasma Chromatography --A New Dimension for Gas Chromatography and Mass Spectrometry
Cohen, M. J., & Karasek, F. W. (1970) · Journal of Chromatographic Science · doi:10.1093/chromsci/8.6.330 · Cited by 365
Kolakowski, B. M., & Mester, Z. (2007) · The Analyst · doi:10.1039/b706039d · Cited by 351
Ion mobility–mass spectrometry: a new paradigm for proteomics
McLean, J. A., Ruotolo, B. T., Gillig, K. J., & Russell, D. H. (2005) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2004.10.003 · Cited by 309
High-resolution ion mobility measurements
Dugourd, P., Hudgins, R. R., Clemmer, D. E., & Jarrold, M. F. (1997) · Review of Scientific Instruments · doi:10.1063/1.1147873 · Cited by 299
Gas-Phase Ion Chromatography: Transition Metal State Selection and Carbon Cluster Formation
Bowers, M. T., Kemper, P. R., von Helden, G., & van Koppen, P. A. M. (1993) · Science · doi:10.1126/science.260.5113.1446 · Cited by 289
Secondary Electrospray Ionization Ion Mobility Spectrometry/Mass Spectrometry of Illicit Drugs
Wu, C., Siems, W. F., & Hill, H. H. (2000) · Analytical Chemistry · doi:10.1021/ac9907235 · Cited by 278
Self-citationMass spectrometric characterization of a high-field asymmetric waveform ion mobility spectrometer
Purves, R. W., Guevremont, R., Day, S., Pipich, C. W., & Matyjaszczyk, M. S. (1998) · Review of Scientific Instruments · doi:10.1063/1.1149255 · Cited by 265
Ion mobility spectrometry: a review. Part 1. Structural analysis by mobility measurement
Creaser, C. S., Griffiths, J. R., Bramwell, C. J., Noreen, S., Hill, C. A., & Thomas, C. L. P. (2004) · The Analyst · doi:10.1039/b404531a · Cited by 235
Valentine, S. J., Anderson, J. G., Ellington, A. D., & Clemmer, D. E. (1997) · The Journal of Physical Chemistry B · doi:10.1021/jp970217o · Cited by 234
Steiner, W. E., Klopsch, S. J., English, W. A., Clowers, B. H., & Hill, H. H. (2005) · Analytical Chemistry · doi:10.1021/ac050278f · Cited by 228
Self-citationProfiling and imaging of tissues by imaging ion mobility‐mass spectrometry
McLean, J. A., Ridenour, W. B., & Caprioli, R. M. (2007) · Journal of Mass Spectrometry · doi:10.1002/jms.1254 · Cited by 209
Wu, C., Siems, W. F., Klasmeier, J., & Hill, H. H. (2000) · Analytical Chemistry · doi:10.1021/ac990601c · Cited by 207
Self-citationShelimov, K. B., & Jarrold, M. F. (1997) · Journal of the American Chemical Society · doi:10.1021/ja962914k · Cited by 205
IMS−IMS and IMS−IMS−IMS/MS for Separating Peptide and Protein Fragment Ions
Merenbloom, S. I., Koeniger, S. L., Valentine, S. J., Plasencia, M. D., & Clemmer, D. E. (2006) · Analytical Chemistry · doi:10.1021/ac052208e · Cited by 200
Unfolding, Refolding, and Hydration of Proteins in the Gas Phase
Jarrold, M. F. (1999) · Accounts of Chemical Research · doi:10.1021/ar960081x · Cited by 185
Isomers of Small Carbon Cluster Anions: Linear Chains with up to 20 Atoms
von Helden, G., Kemper, P. R., Gotts, N. G., & Bowers, M. T. (1993) · Science · doi:10.1126/science.259.5099.1300 · Cited by 179
Clowers, B. H., Dwivedi, P., Steiner, W. E., Hill, H. H., & Bendiak, B. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.01.010 · Cited by 177
Self-citationDwivedi, P., Bendiak, B., Clowers, B. H., & Hill, H. H. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.04.007 · Cited by 174
Self-citationDirect tissue analysis of phospholipids in rat brain using MALDI-TOFMS and MALDI-ion mobility-TOFMS
Jackson, S. N., Wang, H.-Y. J., Woods, A. S., Ugarov, M., Egan, T., & Schultz, J. A. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2004.10.002 · Cited by 167
Evidence for Many Resolvable Structures within Conformation Types of Electrosprayed Ubiquitin Ions
Koeniger, S. L., Merenbloom, S. I., & Clemmer, D. E. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp056165h · Cited by 165
Coupling High-Pressure MALDI with Ion Mobility/Orthogonal Time-of-Flight Mass Spectrometry
Gillig, K. J., Ruotolo, B., Stone, E. G., Russell, D. H., Fuhrer, K., Gonin, M., & Schultz, A. J. (2000) · Analytical Chemistry · doi:10.1021/ac0005619 · Cited by 162
Metabolic profiling by ion mobility mass spectrometry (IMMS)
Dwivedi, P., Wu, P., Klopsch, S. J., Puzon, G. J., Xun, L., & Hill, H. H. (2008) · Metabolomics · doi:10.1007/s11306-007-0093-z · Cited by 160
Self-citationUsing Different Drift Gases To Change Separation Factors (α) in Ion Mobility Spectrometry
Asbury, G. R., & Hill, H. H. (2000) · Analytical Chemistry · doi:10.1021/ac9908952 · Cited by 158
Self-citationToward Plasma Proteome Profiling with Ion Mobility-Mass Spectrometry
Valentine, S. J., Plasencia, M. D., Liu, X., Krishnan, M. R., Naylor, S., Udseth, H. R., Smith, R. D., & Clemmer, D. E. (2006) · Journal of Proteome Research · doi:10.1021/pr060232i · Cited by 156
Baker, E. S., Clowers, B. H., Li, F., Tang, K., Tolmachev, A. V., Prior, D. C., Belov, M. E., & Smith, R. D. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.03.031 · Cited by 143
Two-Dimensional Gas-Phase Separations Coupled to Mass Spectrometry for Analysis of Complex Mixtures
Tang, K., Li, F., Shvartsburg, A. A., Strittmatter, E. F., & Smith, R. D. (2005) · Analytical Chemistry · doi:10.1021/ac050871x · Cited by 141
Hadamard Transform Ion Mobility Spectrometry
Clowers, B. H., Siems, W. F., Hill, H. H., et al. (2005) · Analytical Chemistry · doi:10.1021/ac050615k · Cited by 138
Self-citationAdvances in Ion Mobility Spectrometry: 1980–1990
Eiceman, G. A. (1991) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408349108055024 · Cited by 135
Hadamard Transform Ion Mobility Spectrometry
Szumlas, A. W., Ray, S. J., & Hieftje, G. M. (2006) · Analytical Chemistry · doi:10.1021/ac051743b · Cited by 134
Gabryelski, W., & Froese, K. L. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00002-3 · Cited by 134
Smith, D. P., Giles, K., Bateman, R. H., Radford, S. E., & Ashcroft, A. E. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.09.017 · Cited by 134
Evidence for unfolding and refolding of gas-phase cytochrome c ions in a Paul trap
Badman, E. R., Myung, S., & Clemmer, D. E. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.04.013 · Cited by 130
Myung, S., Wiseman, J. M., Valentine, S. J., Takáts, Z., Cooks, R. G., & Clemmer, D. E. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp052663e · Cited by 126
Capabilities and limitations of ion mobility spectrometry for field screening applications
Hill, H. H., & Simpson, G. (1997) · Field Analytical Chemistry & Technology · doi:10.1002/(sici)1520-6521(1997)1:3<119::aid-fact2>3.0.co;2-s · Cited by 121
Self-citationRobinson, E. W., & Williams, E. R. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.04.007 · Cited by 120
Hudgins, R. R., Woenckhaus, J., & Jarrold, M. F. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00182-1 · Cited by 118
Steiner, W. E., Clowers, B. H., Haigh, P. E., & Hill, H. H. (2003) · Analytical Chemistry · doi:10.1021/ac034349r · Cited by 118
Self-citationAn Ion Trap Interface for ESI−Ion Mobility Experiments
Hoaglund‐Hyzer, C. S., Valentine, S. J., & Clemmer, D. E. (1997) · Analytical Chemistry · doi:10.1021/ac970526a · Cited by 117
Drift Tube-Mass Spectrometer for Studies of Low-Energy Ion-Molecule Reactions
McDaniel, E. W., Martin, D. W., & Barnes, W. S. (1962) · Review of Scientific Instruments · doi:10.1063/1.1717656 · Cited by 111
Shvartsburg, A. A., Li, F., Tang, K., & Smith, R. D. (2006) · Analytical Chemistry · doi:10.1021/ac060283z · Cited by 104
Steiner, W. E., Clowers, B. H., Matz, L. M., Siems, W. F., & Hill, H. H. (2002) · Analytical Chemistry · doi:10.1021/ac025687f · Cited by 103
Self-citationBarnes, C. A. S., Hilderbrand, A. E., Valentine, S. J., & Clemmer, D. E. (2001) · Analytical Chemistry · doi:10.1021/ac0108562 · Cited by 91
Gas phase structures of sodiated oligosaccharides by ion mobility/ion chromatography methods
Lee, S., Wyttenbach, T., & Bowers, M. T. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00105-5 · Cited by 88
Oligonucleotide analysis with MALDI–ion-mobility–TOFMS
Koomen, J. M., Ruotolo, B. T., Gillig, K. J., MCLEAN, J. A. J., Russell, D. H., Kang, M., Dunbar, K. R., Führer, K., Gonin, M., & Schultz, A. J. (2002) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-002-1363-2 · Cited by 77
Steiner, W. E., Clowers, B. H., Führer, K., Gonin, M., Matz, L. M., Siems, W. F., Schultz, A. J., & Hill, H. H. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.495 · Cited by 75
Self-citationPreparation and observation of Si10 clusters on a Au(001)-(5×20) surface
Kuk, Y., Jarrold, M. F., Silvėrman, P. J., et al. (1989) · Physical review. B, Condensed matter · doi:10.1103/physrevb.39.11168 · Cited by 68
Sultan, J., & Gabryelski, W. (2006) · Analytical Chemistry · doi:10.1021/ac060384x · Cited by 64
Conformation of glycosaminoglycans by ion mobility mass spectrometry and molecular modelling
Jin, L. S., Barran, P. E., Deakin, J. A., et al. (2005) · Physical Chemistry Chemical Physics · doi:10.1039/b508644b · Cited by 62
Levin, D. S., Vouros, P., Miller, R. A., & Nazarov, E. G. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.10.008 · Cited by 59
Clowers, B. H., & Hill, H. H. (2006) · Journal of Mass Spectrometry · doi:10.1002/jms.994 · Cited by 57
Self-citationLee, D., Wu, C., & Hill, H. H. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(98)00486-5 · Cited by 56
Self-citationSielemann, S., Baumbach, J., Schmidt, H., & Pilzecker, P. (2000) · Field Analytical Chemistry & Technology · doi:10.1002/1520-6521(2000)4:4<157::aid-fact2>3.0.co;2-# · Cited by 50
Taraszka, J. A., Gao, X., Valentine, S. J., Robinson, R. A. S., Koeniger, S. L., Miller, D. F., Kaufman, T. C., & Clemmer, D. E. (2005) · Journal of Proteome Research · doi:10.1021/pr050037o · Cited by 42
An ion-focusing aspiration condenser as an ion mobility spectrometer
Zimmermann, S., Abel, N., Baether, W., & Barth, S. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.02.038 · Cited by 38
Gontarev, S. V., Shmanai, V. V., Frey, S. K., Kvach, M. V., & Schweigert�, F. J. (2006) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2793 · Cited by 38
A swept-field aspiration condenser as an ion-mobility spectrometer
Sacristán, E., & Solis, A. A. (1998) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.744345 · Cited by 35
Chirally Directed Formation of Nanometer-Scale Proline Clusters
Myung, S., Fioroni, M., Julian, R. R., Koeniger, S. L., Baik, M., & Clemmer, D. E. (2006) · Journal of the American Chemical Society · doi:10.1021/ja0622711 · Cited by 33
π-Helix Preference in Unsolvated Peptides
Sudha, R., Kohtani, M., Breaux, G. A., & Jarrold, M. F. (2004) · Journal of the American Chemical Society · doi:10.1021/ja0381353 · Cited by 20
Cited by
Supramolecular Coordination: Self-Assembly of Finite Two- and Three-Dimensional Ensembles
Chakrabarty, R., Mukherjee, P. S., & Stang, P. J. (2011) · Chemical Reviews · doi:10.1021/cr200077m · Cited by 2,926
Meier, F., Brunner, A.-D., Koch, S., Koch, H., Lubeck, M., Krause, M., Goedecke, N., Decker, J., Kosinski, T., Park, M. A., et al. (2018) · Molecular & Cellular Proteomics · doi:10.1074/mcp.tir118.000900 · Cited by 965
Bush, M. F., Hall, Z., Giles, K., Hoyes, J., Robinson, C. V., & Ruotolo, B. T. (2010) · Analytical Chemistry · doi:10.1021/ac1022953 · Cited by 796
Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rec-06-04-06 · Cited by 687
Ion Mobility Spectrometry: Fundamental Concepts, Instrumentation, Applications, and the Road Ahead
Dodds, J. N., & Baker, E. S. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02288-2 · Cited by 574
Metadata
- Authors
- Kanu, A. B., Dwivedi, P., Tam, M., Matz, L., & Hill, H. H.
- Venue
- Journal of Mass Spectrometry
- Publisher
- Wiley
- Published
- 2008-01
- Volume
- 43
- Issue
- 1
- Pages
- 1-22
- ISSN
- 1076-5174 (ISSN-L)
- 1096-9888
- OpenAlex
- W2059903043
- Cited by
- 1,154
- References
- 71
- FWCI
- 27.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.