The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Organic ion imaging of biological tissue with secondary ion mass spectrometry and matrix‐assisted laser desorption/ionization
Abstract
Organic secondary ion mass spectrometry (SIMS) and matrix‐assisted laser desorption/ionization (MALDI) mass spectrometry can be used to produce molecular images of samples. This is achieved through ionization from a clearly identified point on a flat sample, and performing a raster of the sample by moving the point of ionization over the sample surface. The unique analytical capabilities of mass spectrometry for mapping a variety of biological samples at the tissue level are discussed. SIMS provides information on the spatial distribution of the elements and low molecular mass compounds as well as molecular structures on these compounds, while MALDI yields spatial information about higher molecular mass compounds, including their distributions in tissues at very low levels, as well as information on the molecular structures of these compounds. Application of these methods to analytical problems requires appropriate instrumentation, sample preparation methodology, and a data presentation usually in a three‐coordinate plot where x and y are physical dimensions of the sample and z is the signal amplitude. The use of imaging mass spectrometry is illustrated with several biological systems. Copyright © 2001 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Emmert-Buck, M. R., Bonner, R. F., Smith, P. D., Chuaqui, R. F., Zhuang, Z., Goldstein, S. R., Weiss, R. A., & Liotta, L. A. (1996) · Science · doi:10.1126/science.274.5289.998 · Cited by 2,534
Molecular Imaging of Biological Samples: Localization of Peptides and Proteins Using MALDI-TOF MS
Caprioli, R. M., Farmer, T. B., & Gile, J. (1997) · Analytical Chemistry · doi:10.1021/ac970888i · Cited by 2,234
Self-citationMatrix-assisted ultraviolet laser desorption of non-volatile compounds
Karas, M., Bachmann, D., Bahr, U., & Hillenkamp, F. (1987) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(87)87041-6 · Cited by 1,953
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
Laser Capture Microdissection: Molecular Analysis of Tissue
Bonner, R. F., Emmert-Buck, M., Cole, K., Pohida, T., Chuaqui, R., Goldstein, S., & Liotta, L. A. (1997) · Science · doi:10.1126/science.278.5342.1481 · Cited by 874
Secondary Ion Mass Spectrometry: Basic Concepts, Instrumental Aspects, Applications and Trends
Benninghoven, A., Ruedenauer, F. G., & Werner, H. W. (1987) · Cited by 601
Covey, T. R., Huang, E. C., & Henion, J. D. (1991) · Analytical Chemistry · doi:10.1021/ac00013a003 · Cited by 446
Morris, H. R., Paxton, T., Dell, A., Langhorne, J., Berg, M., Bordoli, R. S., Hoyes, J., & Bateman, R. H. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19960610)10:8<889::aid-rcm615>3.0.co;2-f · Cited by 446
Brown, R. S., & Lennon, J. J. (1995) · Analytical Chemistry · doi:10.1021/ac00109a015 · Cited by 371
Principles and Techniques of Electron Microscopy
Hayat, M. A. (1989) · doi:10.1007/978-1-349-09857-6 · Cited by 323
Cited by
Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray Ionization
Takáts, Z., Wiseman, J. M., Gologan, B., & Cooks, R. G. (2004) · Science · doi:10.1126/science.1104404 · Cited by 3,324
Cooks, R. G., Ouyang, Z., Takats, Z., & Wiseman, J. M. (2006) · Science · doi:10.1126/science.1119426 · Cited by 1,474
McDonnell, L. A., & Heeren, R. M. A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20124 · Cited by 1,082
Takáts, Z., Wiseman, J. M., & Cooks, R. G. (2005) · Journal of Mass Spectrometry · doi:10.1002/jms.922 · Cited by 880
Sphingolipid and Glycosphingolipid Metabolic Pathways in the Era of Sphingolipidomics
Merrill, A. H. (2011) · Chemical Reviews · doi:10.1021/cr2002917 · Cited by 785
Low-Temperature Plasma Probe for Ambient Desorption Ionization
Harper, J. D., Charipar, N. A., Mulligan, C. C., Zhang, X., Cooks, R. G., & Ouyang, Z. (2008) · Analytical Chemistry · doi:10.1021/ac801641a · Cited by 730
The Desorption Process in MALDI
Dreisewerd, K. (2003) · Chemical Reviews · doi:10.1021/cr010375i · Cited by 709
Mass Spectrometric Imaging for Biomedical Tissue Analysis
Chughtai, K., & Heeren, R. M. A. (2010) · Chemical Reviews · doi:10.1021/cr100012c · Cited by 652
Schwartz, S. A., Reyzer, M. L., & Caprioli, R. M. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.505 · Cited by 646
Self-citationWiseman, J. M., Ifa, D. R., Song, Q., & Cooks, R. G. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200602449 · Cited by 626
Intraoperative Tissue Identification Using Rapid Evaporative Ionization Mass Spectrometry
Balog, J., Sasi-Szabó, L., Kinross, J., Lewis, M. R., Muirhead, L. J., Veselkov, K., Mirnezami, R., Dezső, B., Damjanovich, L., Darzi, A., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3005623 · Cited by 608
A concise review of mass spectrometry imaging
Amstalden van Hove, E. R., Smith, D. F., & Heeren, R. M. A. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.01.033 · Cited by 416
Reyzer, M. L., Hsieh, Y., Ng, K., Korfmacher, W. A., & Caprioli, R. M. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.525 · Cited by 371
Self-citationTouboul, D., Kollmer, F., Niehuis, E., Brunelle, A., & Laprévote, O. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.06.005 · Cited by 364
Mass Spectral Analysis in Proteomics
Yates, J. R. (2004) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.33.111502.082538 · Cited by 326
Van Berkel, G. J., Pasilis, S. P., & Ovchinnikova, O. (2008) · Journal of Mass Spectrometry · doi:10.1002/jms.1440 · Cited by 299
Spengler, B., & Hubert, M. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00376-8 · Cited by 292
Bioimaging of metals by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS)
Becker, J. S., Zoriy, M., Matusch, A., Wu, B., Salber, D., Palm, C., & Becker, J. S. (2010) · Mass Spectrometry Reviews · doi:10.1002/mas.20239 · Cited by 287
MALDI-MS imaging of features smaller than the size of the laser beam
Jurchen, J. C., Rubakhin, S. S., & Sweedler, J. V. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.06.006 · Cited by 285
Ifa, D. R., Wiseman, J. M., Song, Q., & Cooks, R. G. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.08.003 · Cited by 261
Tissue Profiling by Mass Spectrometry
Caldwell, R. L., & Caprioli, R. M. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r500006-mcp200 · Cited by 259
Self-citationMass Spectrometric Profiling of Intact Biological Tissue by Using Desorption Electrospray Ionization
Wiseman, J. M., Puolitaival, S. M., Takáts, Z., Cooks, R. G., & Caprioli, R. M. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200502362 · Cited by 255
Self-citationProteomics in Diagnostic Pathology
Chaurand, P., Sanders, M. E., Jensen, R. A., & Caprioli, R. M. (2004) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)63367-6 · Cited by 253
Self-citation
Metadata
- Authors
- Todd, P. J., Schaaff, T. G., Chaurand, P., & Caprioli, R. M.
- Venue
- Journal of Mass Spectrometry
- Publisher
- Wiley
- Published
- 2001-04
- Volume
- 36
- Issue
- 4
- Pages
- 355-369
- ISSN
- 1076-5174 (ISSN-L)
- 1096-9888
- OpenAlex
- W2047127389
- Cited by
- 298
- References
- 25
- FWCI
- 7.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.