Evaluation of orthogonal mechanical properties and density of human trabecular bone from the major metaphyseal regions with materials testing and computed tomography
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
We evaluated the orthogonal mechanical properties of human trabecular bone from the major metaphyseal regions with materials testing and quantitative computed tomography (CT). The proximal tibia, distal femur, proximal femur, distal radius, and proximal humerus from fresh cadaver specimens between the ages of 55 and 70 years were excised and prepared for experimentation. The bones were embedded and scanned at 1 or 1.5 mm intervals on a Technicare HPS 1440 and GE 9800 CT scanner. After scanning, the bones were sectioned, producing 8‐mm cubes of trabecular bone which were mechanically tested in uniaxial compression at a strain rate of 1%/s. The testing sequence consisted of preyield tests in two of the three orthogonal directions and failure in the third. After testing, the cubes were evaluated for apparent density and ash weight. The results of the study show that the strength and stiffness of trabecular bone varies significantly within metaphyseal regions and from metaphysis to metaphysis. The power and significance of relationships between density and modulus varied as a function of metaphyseal location. Both linear and nonlinear models were significant, suggesting that trabecular deformation occurs in response to both axial and bending loads. Finally, the need for architectural measures of trabecular bone to predict mechanical properties is emphasized.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.1–30 MPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [89]
In the citing paper
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.1–30 MPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [89]
In the citing paper
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.1–30 MPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [89]
In the citing paper
“The anisotropy that trabecular bone exhibits in microstructure is also present in elastic modulus (89) and strength (92).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [89]
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
The mechanics of three-dimensional cellular materials
Gibson, I. J., & Ashby, M. F. (1982) · Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences · doi:10.1098/rspa.1982.0088 · Cited by 1,885
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
The mechanical properties of trabecular bone: Dependence on anatomic location and function
Goldstein, S. A. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90023-6 · Cited by 687
Self-citationPrediction of vertebral body compressive fracture using quantitative computed tomography.
McBroom, R. J., Hayes, W. C., Edwards, W. T., Goldberg, R. P., & White, A. A. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567080-00010 · Cited by 432
Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial Epiphysis
Williams, J. L., & Lewis, J. L. (1982) · Journal of Biomechanical Engineering · doi:10.1115/1.3138303 · Cited by 415
Physical properties of trabecular bone
Galante, J., Rostoker, W., & Ray, R. D. (1970) · Calcified Tissue Research · doi:10.1007/bf02017552 · Cited by 302
The mechanical properties of human tibial trabecular bone as a function of metaphyseal location
Goldstein, S. A., Wilson, D. L., Sonstegard, D. A., & Matthews, L. S. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90097-0 · Cited by 292
Self-citationMechanical Properties of Trabecular Bone from the Proximal Femur: A Quantitative CT Study
Lotz, J. C., Gerhart, T. N., & Hayes, W. C. (1990) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199001000-00020 · Cited by 284
Research works printed but not linked: 4
- Evans FG, 1961, Biomechanical Studies of the Musculoskeletal System, 49
- Wolff J, 1892, Das Gestez der Transformation der Knochen
- Yokoo S, 1952, Compression test of the cancellous bone, J Kyoto Pref Med Univ, 51, 273
- Arnold JS, 1960, Quantitation of mineralization of bone as an orgen and tissue in osteoporosis, Clin Orthop, 17, 167
Cited by
Items 101–200 of 400
Tommasini, S. M., Kwaczala, A. T., Acerbo, A. S., Carlo, F. D., Miller, L. M., & Judex, S. (2011) · Bone · doi:10.1016/j.bone.2011.12.012 · Cited by 70
“treatments formusculoskeletal diseasesmay influence not only bone's quantity but also its quality, ultimately improving (or compromising) bone's ability to resist load [5,6].”
Krone, R., & Schuster, P. (2006) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2006-01-0064 · Cited by 67
“Much work has also been done to ascertain the femur bone tissue constituents' (cortical and cancellous) linear and non-linear material properties by methods ranging from mechanical and acoustic testing to more theoretical means [7, 8, 9, 10, 11, 12, 13, 15, 16, 17].”
BackgroundPullout strength of suture anchors: Effect of mechanical properties of trabecular bone
Poukalova, M., Yakacki, C. M., Guldberg, R. E., Lin, A., Saing, M. H., Gillogly, S. D., & Gall, K. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.12.007 · Cited by 66
“Other studies have investigated the relationships between BMD and mechanical properties such as compressive strength and modulus (Pugh et al., 1973; Hvid et al., 1989; Ciarelli et al., 1991; Goulet et al., 1994; Mimar et al., 2008).”
BackgroundMethodResultInfluentialWang, M. O., Piard, C., Melchiorri, A. J., Dreher, M. L., & Fisher, J. P. (2015) · Tissue Engineering Part A · doi:10.1089/ten.tea.2014.0495 · Cited by 68
Human Brown Fat Radiodensity Indicates Underlying Tissue Composition and Systemic Metabolic Health
U-Din, M., Raiko, J. R. H., Saari, T., Saunavaara, V., Kudomi, N., Solin, O. H., Parkkola, R. K., Nuutila, P., & Virtanen, K. A. (2017) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2016-2698 · Cited by 88
In vivo characterization of glenoid with use of computed tomography
Couteau, B., Mansat, P., Mansat, M., Darmana, R., & Egan, J. (2001) · Journal of Shoulder and Elbow Surgery · doi:10.1067/mse.2001.112884 · Cited by 66
Majumdar, S. (1998) · Technology and Health Care · doi:10.3233/thc-1998-65-605 · Cited by 63
“This results in trabecular bone micro-architecture being dependent on the anatomic site, as well as having a directional anisotropy of the mechanical properties and architecture [6–10].”
BackgroundWachter, N. J., Augat, P., Mentzel, M., Sarkar, M. R., Krischak, G. D., Kinzl, L., & Claes, L. (2001) · Bone · doi:10.1016/s8756-3282(00)00455-5 · Cited by 58
The Zürich Experience: One Decade of Three-Dimensional High-Resolution Computed Tomography
Müller, R. (2002) · Topics in Magnetic Resonance Imaging · doi:10.1097/00002142-200210000-00003 · Cited by 59
“This new method uses sequential structural images from stepwise microcompression testing to (1) align all images from the different steps; (2) identify local anatomic features (nodes) in the structure that can be followed directly in the structure throughout all the steps; (3) create a network of connections between t…”
BackgroundMethodChanges in mean trabecular orientation in the medial condyle of the proximal tibia in osteoarthritis
Kamibayashi, L., WYSS, U. P., Cooke, T. D. V., & Zee, B. C.-Y. (1995) · Calcified Tissue International · doi:10.1007/bf00299000 · Cited by 56
Keaveny, T. M., & Bartel, D. L. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90087-u · Cited by 56
Cancellous Bone Strains Indicate Efficacy of Stem Augmentation in Constrained Condylar Knees
Rawlinson, J., Peters, L. E., Campbell, D. A., Windsor, R. E., Wright, T. M., & Bartel, D. L. (2005) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000187340.10003.68 · Cited by 55
“four studies of cancellous bone alone in the human proximal tibia were used.(1,3,9,13) Because mechanical testing can underes-”
BackgroundDevelopment of the fetal ilium – challenging concepts of bipedality
Cunningham, C. A., & Black, S. M. (2008) · Journal of Anatomy · doi:10.1111/j.1469-7580.2008.01005.x · Cited by 59
“In recent studies, and indeed in the historical literature, much work has concentrated on the investigation of trabecular bone architecture with the aim of elucidating its mechanical role within the skeletal system (Evans, 1973; Lanyon, 1974; Carter & Hayes, 1977; Gibson, 1985; Goldstein, 1987; Frost, 1990; Ciarelli e…”
BackgroundSpeed of sound reflects Young’s modulus as assessed by microstructural finite element analysis
van den Bergh, J. P., van Lenthe, H., Hermus, A. R. M. M., Corstens, F. H. M., SMALS, A. G. H., & Huiskes, R. (2000) · Bone · doi:10.1016/s8756-3282(00)00249-0 · Cited by 57
Bone density does not reflect mechanical properties in early-stage arthrosis
Ding, M. L., Danielsen, C. C., & Hvid, I. (2001) · Acta Orthopaedica Scandinavica · doi:10.1080/000164701317323444 · Cited by 54
“In normal cancellous bone, the variation in mechanical properties can be reliably predicted by bone density (Ciarelli et al. 1991).”
BackgroundAnderson, D. D., Mosqueda, T., Thomas, T. P., Hermanson, E. L., Brown, T. D., & Marsh, J. L. (2008) · Journal of Orthopaedic Research® · doi:10.1002/jor.20550 · Cited by 56
Wu, Y., Adeeb, S., & Doschak, M. R. (2015) · Frontiers in Endocrinology · doi:10.3389/fendo.2015.00080 · Cited by 63
“The Young’s modulus in each trabecula can be correlated to values of HU (26).”
BackgroundDiederichs, G., Korner, J., Goldhahn, J., & Linke, B. (2006) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-006-0103-z · Cited by 53
“In this study bone density was determined by pQCT, which is not suitable for measurement in the clinical setting.”
BackgroundInfluentialWang, L., Zhang, H., & Fan, Y. (2011) · Science China Life Sciences · doi:10.1007/s11427-011-4242-2 · Cited by 49
Fölsch, C., Goost, H., Figiel, J. H., Paletta, J. R. J., Schultz, W., & Lakemeier, S. (2012) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2012-0012 · Cited by 49
Patient‐specific finite element models of the human mandible: Lack of consensus on current set‐ups
Merema, B. B. J., Kraeima, J., Glas, H. H., Spijkervet, F. K. L., & Witjes, M. J. H. (2020) · Oral Diseases · doi:10.1111/odi.13381 · Cited by 48
A review of mouse critical size defect models in weight bearing bones
Harris, J. S., Bemenderfer, T. B., Wessel, A. R., & Kacena, M. A. (2013) · Bone · doi:10.1016/j.bone.2013.02.002 · Cited by 53
“This is largely based off the fact that the attenuation coefficient values (Hounsfield values) can predict the Young’s modulus of bone tissue [39].”
BackgroundMechanical properties of glenoid cancellous bone
Kalouche, I., Crépin, J., Abdelmoumen, S., Mitton, D., Guillot, G., & Gagey, O. (2010) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2009.12.009 · Cited by 46
“This anisotropy varies significantly within metaphyseal regions and in different metaphysis of the human body (Ciarelli et al., 1991).”
BackgroundEffect of load on the bone around bone-anchored amputation prostheses
Stenlund, P., Trobos, M., Lausmaa, J., Brånemark, R., Thomsen, P., & Palmquist, A. (2016) · Journal of Orthopaedic Research® · doi:10.1002/jor.23352 · Cited by 47
Design and implementation of a novel mechanical testing system for cellular solids
Nazarian, A., Stauber, M., & Müller, R. (2005) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.30232 · Cited by 49
“shown that changes in trabecular microarchitecture lead to disproportionate changes in trabecular bone strength.(19)”
BackgroundHu, J.-P., Ding, M. L., Søballé, K., Bechtold, J. E., Danielsen, C. C., Day, J. S., & Hvid, I. (2002) · Bone · doi:10.1016/s8756-3282(02)00870-0 · Cited by 45
Mapping anisotropy of the proximal femur for enhanced image based finite element analysis
Enns-Bray, W. S., Owoc, J. S., Nishiyama, K. K., & Boyd, S. K. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.08.020 · Cited by 52
Permeability study of cancellous bone and its idealised structures
Syahrom, A., Kadir, M. R. A., Harun, M. N., & Öchsner, A. Ö. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.11.001 · Cited by 47
Shu, J., Yao, J., Zhang, Y., Chong, D. Y. R., & Liu, Z. (2018) · Medicine · doi:10.1097/md.0000000000011204 · Cited by 43
Les, C. M., STOVER, S. M., Keyak, J. H., Taylor, K. T., & Willits, N. H. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(96)00157-1 · Cited by 43
“Researchers investigating trabecular bone material properties have been able to demonstrate significant regional variation of material properties, and to relate patterns of architecture and/or density to the functional demands placed on the structure in vim, for both humans (Ashman et al., 1989; Ciarelli et al., 1991;…”
BackgroundThe assessment of vertebral bone macroarchitecture with x-ray computed tomography
Flynn, M. J., & CODY, D. D. (1993) · Calcified Tissue International · doi:10.1007/bf01673430 · Cited by 46
“overall structural characteristics of small volumes of vertebral cancellous bone are experimentally well correlated with its bulk density [40, 41] as predicted by a theoretical model”
BackgroundSelf-citationLengsfeld, M., Burchard, R., Günther, D., Pressel, T., Schmitt, J., Leppek, R., & GRISS, P. (2005) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.12.016 · Cited by 40
Biomechanism of impact resistance in the woodpecker’s head and its application
Wang, L., Lu, S., Liu, X., Niu, X., Wang, C., Ni, Y., Zhao, M., Feng, C., Zhang, M., & Fan, Y. (2013) · Science China Life Sciences · doi:10.1007/s11427-013-4523-z · Cited by 45
Tuncer, M., Hansen, U. N., & Amis, A. A. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.04.006 · Cited by 49
Kowalczyk, P. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00065-4 · Cited by 46
The Effect of Trabecular Structure on DXA-based Predictions of Bovine Bone Failure
Oden, Z. M., Selvitelli, D. M., Hayes, W. C., & Myers, E. R. (1998) · Calcified Tissue International · doi:10.1007/s002239900491 · Cited by 47
“Unlike the current study, however, many of these studies collected samples in anatomical orientations and did not differentiate between orientations of the trabeculae within their sample [32, 33].”
ResultBurchard, R., Graw, J. A., Soost, C., & Schmitt, J. (2023) · International Orthopaedics · doi:10.1007/s00264-023-05825-7 · Cited by 41
“Since FE models provide consistent bony strain patterns and are independent from the density-modulus relationship, it was possible to use a linear relationship according to studies from Ciarelli and colleagues [27].”
ResultShu, J., Ma, H., Jia, L., Fang, H., Chong, D. Y. R., Zheng, T., Yao, J., & Liu, Z. (2020) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3373 · Cited by 42
Validation of a finite element model of the human metacarpal
Barker, D. S., Netherway, D. J., Krishnan, J., & Hearn, T. C. (2004) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.10.001 · Cited by 40
Biavati, A. S., Tecco, S., Migliorati, M., Festa, F., Marzo, G., Gherlone, E. F., & Tetè, S. (2011) · Orthodontics and Craniofacial Research · doi:10.1111/j.1601-6343.2011.01512.x · Cited by 39
“(22) reported that screw stability was most closely related to cortical bone thickness and bone density.”
BackgroundInterfragmentary surface area as an index of comminution severity in cortical bone impact
Beardsley, C. L., Anderson, D. D., Marsh, J. L., & Brown, T. D. (2005) · Journal of Orthopaedic Research® · doi:10.1016/j.orthres.2004.09.008 · Cited by 44
“Over the range of densities found in biological tissues, for all practical purposes, the Hounsfield value varies linearly with tissue density [6,9,10,15].”
BackgroundMethodSyahrom, A., Kadir, M. R. A., Abdullah, J. B., & Öchsner, A. Ö. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0833-0 · Cited by 38
“analysed through either computational [5, 8, 10, 11, 32, 36, 38, 49, 58–60] or experimental means [1, 2, 4, 13, 16, 18, 25, 31, 35, 46, 47, 61–66].”
MethodIn vitro evidence of the structural optimization of the human skeletal bones
Cristofolini, L. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.12.010 · Cited by 38
Pineda, L. M., B�sing, M., Meinig, R. P., & Gogolewski, S. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199607)31:3<421::aid-jbm17>3.0.co;2-l · Cited by 106
Zhang, M., Grégory, T., Hansen, U., & Cheng, C. (2020) · Journal of Orthopaedic Research® · doi:10.1002/jor.24711 · Cited by 36
“In this study, the bone material property on each element in the model was constant, while the real bone is anisotropic and may have a considerable variation in Young's modulus in different directions.(32,33) Another possible reason for the difference in results is the accuracy of the measurement tools.”
ResultA digital model of trabecular bone
Engelke, K., Song, S. M., Glüer, C.-C., & Genant, H. K. (1996) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650110409 · Cited by 36
Feng, Y., Shu, J., Liu, Y., Zheng, T., Shao, B., & Liu, Z. (2021) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2021.106299 · Cited by 37
Schneider, R., Faust, G., Hindenlang, U., & Helwig, P. (2009) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2009.02.010 · Cited by 43
Wang, L., Niu, X., Ni, Y., Xu, P., Liu, X., Lu, S., Zhang, M., & Fan, Y. (2013) · Journal of Nanomaterials · doi:10.1155/2013/924564 · Cited by 34
Analysis of titanium induced CT artifacts in the development of biomechanical finite element models
Zannoni, C., Viceconti, M., Pierotti, L., & Cappello, A. (1998) · Medical Engineering & Physics · doi:10.1016/s1350-4533(98)00076-9 · Cited by 34
Shu, J., Teng, H., Shao, B., Zheng, T., Liu, Y., & Liu, Z. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2020.105671 · Cited by 35
Winsor, C., Li, X., Qasim, M., Henak, C. R., Pickhardt, P. J., Ploeg, H., & Viceconti, M. (2020) · Bone · doi:10.1016/j.bone.2020.115759 · Cited by 39
Cody, D. C., McCubbrey, D. A., Divine, G., Gross, G. J., & Goldstein, S. A. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00133-6 · Cited by 41
“There has been disagreement regarding the usefulness of power functions to relate bone apparent density to mechanical properties vs a more simple linear regression approach (Carter and Hayes, 1977; Ciarelli et al., 1991; Ducheyne et al., 1977; Esses et al., 1989; Gibson, 1985; Keller, 1994; Lotz et al., 1990; Rice et…”
BackgroundResultSelf-citationCreep of trabecular bone from the human proximal tibia
Novitskaya, E. E., Zin, C., Chang, N., Cory, E., Chen, P., DʼLima, D. D., Sah, R. L., & McKittrick, J. M. (2014) · Materials Science and Engineering C · doi:10.1016/j.msec.2014.03.057 · Cited by 31
“Creep in bone is a complex phenomenon and varies with type of loading and local mechanical properties [19,24,25].”
BackgroundBonaretti, S., Seiler, C., Boichon, C., Reyes, M., & Büchler, P. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.09.006 · Cited by 31
Mechanical Properties of Subchondral Cancellous Bone of the Radial Head
Gordon, K., Duck, T. R., King, G. J. W., & Johnson, J. A. (2003) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-200304000-00007 · Cited by 30
“Ciarelli et al (4) tested bone properties of the distal Figure 3.”
BackgroundInfluentialBiomechanics of Bone and Age-Related Fractures
Morgan, E. F., & Bouxsein, M. (2008) · Elsevier eBooks · doi:10.1016/b978-0-12-373884-4.00024-0 · Cited by 40
Modeling Modulus Reduction in Bovine Trabecular Bone Damaged in Compression
Moore, T. L. A., & Gibson, L. J. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1407828 · Cited by 34
Separate effects of osteoporosis and density on the strength and stiffness of human cancellous bone
Hodgskinson, R., & Currey, J. D. (1993) · Clinical Biomechanics · doi:10.1016/0268-0033(93)90036-h · Cited by 36
Bone Density Measurement Using Computed Tomography
Çelenk, Ç., & Çelenk, P. (2012) · InTech eBooks · doi:10.5772/22884 · Cited by 28
“, Hounsfield units, HU) are strongly related to biological tissues density (Ciarelli et al., 1991; McB- room et al., 1985).”
BackgroundValidation of multiple subject-specific finite element models of unicompartmental knee replacement
Tuncer, M., Cobb, J. P., Hansen, U. N., & Amis, A. A. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.03.020 · Cited by 34
Load-bearing capacity of corticocancellous bone grafts in the spine.
Smith, M. D., & CODY, D. D. (1993) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199308000-00010 · Cited by 27
Self-citationAnatomic and Directional Variation in the Mechanical Properties of the Mandibular Condyle in Pigs
Teng, S., & Herring, S. W. (1996) · Journal of Dental Research · doi:10.1177/00220345960750110501 · Cited by 33
“, 1990; Fiala and Hert, 1993; Teng and Herring, 1995), as do the mechanical properties (Brown and Ferguson, 1980; Goldstein, 1987; Vahey et al., 1987; Ciarelli et al., 1991; Goulet et al., 1994).”
BackgroundPreparation of On-Axis Cylindrical Trabecular Bone Specimens Using Micro-CT Imaging
Wang, X., Liu, A. X., & Niebur, G. L. (2004) · Journal of Biomechanical Engineering · doi:10.1115/1.1645866 · Cited by 29
Hohn, B., Preuschoft, H., Witzel, U., & Distler-Hoffmann, C. (2013) · Historical Biology · doi:10.1080/08912963.2012.755677 · Cited by 33
“Therefore, the material properties chosen for the whole FE model, such as Young’s modulus (10GPa) and Poisson’s ratio (0.3), are based on an average value for cortical (Rho et al. 1995) and cancellous bone (Ciarelli et al. 1991).”
MethodInfluentialOrthotropic properties of cancellous bone modelled as parameterized cellular material
Kowalczyk, P. (2006) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840600751473 · Cited by 29
“Mechanical tests of bone specimens (see e.g. Goldstein et al. 1983, Martens et al. 1983, Ashman et al. 1989, Ciarelli et al. 1991, Hobatho et al. 1997, Giesen et al. 2001) have numerous limitations (see discussion in Kowalczyk 2003), let us only mention their fragmentary character (limited number…”
Backgroundvan Lenthe, H., van den Bergh, J. P., Hermus, A. R. M. M., & Huiskes, R. (2001) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2001.16.3.550 · Cited by 28
“((1,10,11))At least part of the variation can be explained by taking the anisotropy of the specimens into account.”
BackgroundRho, J. Y., Flaitz, D. J., Swarnakar, V., & Acharya, R. S. (1997) · Bone · doi:10.1016/s8756-3282(97)00022-7 · Cited by 26
Two and three-dimensional morphometric analysis of trabecular bone using X-ray microtomography (µCT)
da Silva, A. M. H., Alves, J. M., da Silva, O. L., & da Silva, N. F. (2014) · Research on Biomedical Engineering · doi:10.1590/rbeb.2014.011 · Cited by 34
“The bone density of cancellous bone was related to strength and was observed a strong positive correlation between the density and the maximum breakdown stress and between density and stiffness (Carter and Hayes, 1977; Ciarelli et al., 1991; Currey, 1969; Rice et al., 1988).”
BackgroundCampbell‐Malone, R. (2007) · Open Access Server of the Woods Hole Scientific Community (Woods Hole Scientific Community) · doi:10.1575/1912/1817 · Cited by 27
Trabecular bone failure at the microstructural level
Müller, R., & van Lenthe, H. (2006) · Current Osteoporosis Reports · doi:10.1007/s11914-006-0007-4 · Cited by 31
“This mechanical anisotropy is expressed as the ratio of the stiffness in the strongest direction to the stiffness in the weakest direction, and can range from basically 1 (no preferential orientation) to over 10 for both stiffness and strength [43–45].”
BackgroundBiology and Biomechanics in Osteosynthesis of Proximal Humerus Fractures
Hepp, P., & Josten, C. (2007) · European Journal of Trauma and Emergency Surgery · doi:10.1007/s00068-007-7089-2 · Cited by 25
Gomez, M. A., & Nahum, A. M. (2002) · Springer eBooks · doi:10.1007/978-0-387-21787-1_10 · Cited by 25
Assessment of bone formation in a porcine mandibular distraction wound by computed tomography
Zimmermann, C. E., Harris, G. J., Thurmüller, P., Troulis, M. J., Perrott, D. H., Rahn, B. A., & Kaban, L. B. (2004) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2004.01.022 · Cited by 25
Finite Element Modeling in Musculoskeletal Biomechanics
Brown, T. D. (2004) · Journal of Applied Biomechanics · doi:10.1123/jab.20.4.336 · Cited by 24
Femoral head necrosis: A finite element analysis of common and novel surgical techniques
Cilla, M., Checa, S., Preininger, B., Winkler, T., Perka, C., Duda, G. N., & Pumberger, M. (2017) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2017.07.005 · Cited by 29
“This phantom was recorded at the same time as the acquisition of the patient-specific CT (Ciarelli et al., 1991; McBroom et al., 1985).”
Structural and Radiological Parameters for the Nondestructive Characterization of Trabecular Bone
Pattijn, V., Cleynenbreugel, T. V., Sloten, J. V., Audekercke, R. V., der Perre, G. V., & Wevers, M. (2001) · Annals of Biomedical Engineering · doi:10.1114/1.1424922 · Cited by 25
The Effect of NaF In Vitro on the Mechanical and Material Properties of Trabecular and Cortical Bone
Thurner, P. J., Erickson, B. W., Turner, P., Jungmann, R., Lelujian, J., Proctor, A., Weaver, J. C., Schitter, G., Morse, D. E., & Hansma, P. K. (2008) · Advanced Materials · doi:10.1002/adma.200801204 · Cited by 23
Lin, Y., Yu, D., Chen, X., Wang, X., Shen, G., & Chengtao, W. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4026104 · Cited by 23
Keaveny, T. M. (1998) · Springer eBooks · doi:10.1007/978-1-4615-5801-9_2 · Cited by 31
Stubbs, C. J., Larson, R., & Cook, D. D. (2020) · Biosystems Engineering · doi:10.1016/j.biosystemseng.2020.10.008 · Cited by 22
Understanding and utilizing textile-based electrostatic flocking for biomedical applications
McCarthy, A. D., Shah, R., John, J. V., Brown, D., & Xie, J. (2021) · Applied Physics Reviews · doi:10.1063/5.0070658 · Cited by 26
An Overview of Selected Material Properties in Finite Element Modeling of the Human Femur
Bazyar, P., Baumgart, A., Altenbach, H., & Usbeck, A. K. (2023) · Biomechanics · doi:10.3390/biomechanics3010012 · Cited by 31
Field, D. J., Campbell‐Malone, R., Goldbogen, J. A., & Shadwick, R. E. (2010) · The Anatomical Record · doi:10.1002/ar.21165 · Cited by 22
Lancianese, S. L., Kwok, E., Beck, C. A., & Lerner, A. L. (2008) · Bone · doi:10.1016/j.bone.2008.07.247 · Cited by 22
“95 [33,35,36] respectively.”
Burchard, R., Braas, S., Soost, C., Graw, J. A., & Schmitt, J. (2017) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-017-1702-2 · Cited by 23
“Therefore, the CT Hounsfield values (HU) were converted linearly into elastic moduli while bone was located between 170 and 1799 HU and transferred linearly to elastic moduli between 1500 and 15,000 MPa [17, 18].”
BackgroundMethodInfluentialMicrostructure of trabecular bone in a mouse model for down syndrome
Parsons, T. E., Ryan, T. M., Reeves, R. H., & Richtsmeier, J. T. (2007) · The Anatomical Record · doi:10.1002/ar.20494 · Cited by 21
“The specific architectural qualities of trabecular bone are affected by a number of factors, including genes, environment, applied loads, nutrition, and infection (Parfitt, 1983; Currey, 1984; Lanyon and Rubin, 1985; Carter et al., 1987; Shimada et al., 1990; Hall, 2005).”
BackgroundBone Density Development of the Temporal Bone Assessed by Computed Tomography
Takahashi, K., Morita, Y., Ohshima, S., Izumi, S., Kubota, Y., & Horii, A. (2017) · Otology & Neurotology · doi:10.1097/mao.0000000000001566 · Cited by 21
“Because the CT values of most cortical bones in the extremities of adults were over 1000 HU (10), 1000 HU was considered the indicator of cortical bone maturation.”
BackgroundLeahy, P. D., Smith, B. S., Easton, K. L., Kawcak, C. E., Eickhoff, J. C., Shetye, S. S., & Puttlitz, C. M. (2010) · Bone · doi:10.1016/j.bone.2010.01.366 · Cited by 25
Tabor, Z. (2003) · Bone · doi:10.1016/j.bone.2003.10.002 · Cited by 21
“It follows from experimental studies that only 40–80% of the variance of trabecular bone strength measured in vitro can be explained by bone density alone while the remainder is attributed to the properties of trabecular bone architecture [5].”
BackgroundSchmitt, J., Meiforth, J., & Lengsfeld, M. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00085-6 · Cited by 21
Praveen, A. D., De, S. D., Sun, K. K., Doshi, H. K., & Lee, T. (2013) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2013.785536 · Cited by 20
“for cancellous bone based on the average Hounsfield value (Ciarelli et al. 1991).”
MethodMapping the Multi‐Directional Mechanical Properties of Bone in the Proximal Tibia
Munford, M. J., Ng, K. C. G., & Jeffers, J. R. T. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202004323 · Cited by 19
Design and manufacturing of biomimetic porous metal implants
Rana, M., Karmakar, S. K., Pal, B., Datta, P., Chowdhury, A. R., & Bandyopadhyay, A. K. (2021) · Journal of materials research/Pratt's guide to venture capital sources · doi:10.1557/s43578-021-00307-1 · Cited by 20
Amir, E., Whyne, C. M., Freedman, O. C., Fralick, M., Kumar, R., Hardisty, M., & Clemons, M. J. (2009) · Clinical & Experimental Metastasis · doi:10.1007/s10585-009-9247-x · Cited by 20
“mechanical properties, and to the quantitative computed tomography (QCT) data of bone without metastatic disease [10, 11].”
BackgroundMicromechanical evaluation of bone microstructures under load
Müller, R., Boesch, T., Jarak, D., Stauber, M., Nazarian, A., Tantillo, M., & Boyd, S. K. (2002) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.452845 · Cited by 24
Carretero, J. M., Rodríguez, L., García‐González, R., Quam, R., & Arsuaga, J. L. (2018) · Journal of Anatomy · doi:10.1111/joa.12886 · Cited by 22
“To ensure we do not artificially add bone volume, we manually established a bone–air limit based on the standard HU fixed by medical analysis, in which Hounsfield densities of about 200 HU are considered trabecular bone (Ciarelli et al. 1991; Oliveira et al. 2008).”
MethodWood, Z., Lynn, L., Nguyen, J. T., Black, M. A., Patel, M. K., & Barak, M. M. (2019) · Bone · doi:10.1016/j.bone.2019.08.002 · Cited by 21
“This correlated well with the need of the distal femur to withstand stresses over an extended range of flexion angles [67].”
BackgroundMultiplanar variations in the structural characteristics of cancellous bone
Zhu, M., Keller, T. S., Moeljanto, E., & Spengler, D. M. (1994) · Bone · doi:10.1016/8756-3282(94)90286-0 · Cited by 22
Chatzigeorgiou, C., Piotrowski, B., Meraghni, F., & Chemisky, Y. (2025) · Results in Engineering · doi:10.1016/j.rineng.2025.103984 · Cited by 19
Metadata
- Authors
- Ciarelli, M. J., Goldstein, S. A., Kuhn, J. L., Cody, D. D., & Brown, M. B.
- Affiliations
- University of Michigan (US)
- Henry Ford Health (US)
- Corresponding author
- Goldstein, S. A.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1991-09
- Volume
- 9
- Issue
- 5
- Pages
- 674-682
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2048282929
- Cited by
- 401
- References
- 28
- Citations by year
- 2026: 10 · 2025: 6 · 2024: 16 · 2023: 21 · 2022: 7 · 2021: 12 · 2020: 13 · 2019: 9 · 2018: 12 · 2017: 8 · 2016: 8 · 2015: 7 · 2014: 17 · 2013: 14 · 2012: 11
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Orthopaedic Research® (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01ar034399-12)
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR34399)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- trabecular bone, bone mineral density, elastic modulus, uniaxial compression, flexural failure, trabecular bone microarchitecture, cadaveric bone, tibia, femur, radius, humerus, bone strength
- MeSH terms
- Aged, Biomechanical Phenomena, Bone and Bones, Humans, Male, Middle Aged, Tomography, X-Ray Computed, Bone Density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.