Evaluation of orthogonal mechanical properties and density of human trabecular bone from the major metaphyseal regions with materials testing and computed tomography
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
We evaluated the orthogonal mechanical properties of human trabecular bone from the major metaphyseal regions with materials testing and quantitative computed tomography (CT). The proximal tibia, distal femur, proximal femur, distal radius, and proximal humerus from fresh cadaver specimens between the ages of 55 and 70 years were excised and prepared for experimentation. The bones were embedded and scanned at 1 or 1.5 mm intervals on a Technicare HPS 1440 and GE 9800 CT scanner. After scanning, the bones were sectioned, producing 8‐mm cubes of trabecular bone which were mechanically tested in uniaxial compression at a strain rate of 1%/s. The testing sequence consisted of preyield tests in two of the three orthogonal directions and failure in the third. After testing, the cubes were evaluated for apparent density and ash weight. The results of the study show that the strength and stiffness of trabecular bone varies significantly within metaphyseal regions and from metaphysis to metaphysis. The power and significance of relationships between density and modulus varied as a function of metaphyseal location. Both linear and nonlinear models were significant, suggesting that trabecular deformation occurs in response to both axial and bending loads. Finally, the need for architectural measures of trabecular bone to predict mechanical properties is emphasized.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.1–30 MPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [89]
In the citing paper
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.1–30 MPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [89]
In the citing paper
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.1–30 MPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [89]
In the citing paper
“The anisotropy that trabecular bone exhibits in microstructure is also present in elastic modulus (89) and strength (92).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [89]
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
The mechanics of three-dimensional cellular materials
Gibson, I. J., & Ashby, M. F. (1982) · Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences · doi:10.1098/rspa.1982.0088 · Cited by 1,885
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
The mechanical properties of trabecular bone: Dependence on anatomic location and function
Goldstein, S. A. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90023-6 · Cited by 687
Self-citationPrediction of vertebral body compressive fracture using quantitative computed tomography.
McBroom, R. J., Hayes, W. C., Edwards, W. T., Goldberg, R. P., & White, A. A. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567080-00010 · Cited by 432
Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial Epiphysis
Williams, J. L., & Lewis, J. L. (1982) · Journal of Biomechanical Engineering · doi:10.1115/1.3138303 · Cited by 415
Physical properties of trabecular bone
Galante, J., Rostoker, W., & Ray, R. D. (1970) · Calcified Tissue Research · doi:10.1007/bf02017552 · Cited by 302
The mechanical properties of human tibial trabecular bone as a function of metaphyseal location
Goldstein, S. A., Wilson, D. L., Sonstegard, D. A., & Matthews, L. S. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90097-0 · Cited by 292
Self-citationMechanical Properties of Trabecular Bone from the Proximal Femur: A Quantitative CT Study
Lotz, J. C., Gerhart, T. N., & Hayes, W. C. (1990) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199001000-00020 · Cited by 284
Research works printed but not linked: 4
- Evans FG, 1961, Biomechanical Studies of the Musculoskeletal System, 49
- Wolff J, 1892, Das Gestez der Transformation der Knochen
- Yokoo S, 1952, Compression test of the cancellous bone, J Kyoto Pref Med Univ, 51, 273
- Arnold JS, 1960, Quantitation of mineralization of bone as an orgen and tissue in osteoporosis, Clin Orthop, 17, 167
Cited by
Items 301–400 of 400
Sadighi, A., Taheri, M., Black, N., Stolle, J. T., Taghvaei, M., Boyes, M. S., Siegler, S., Schaer, T. P., & Najafi, A. R. (2025) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-025-02001-1 · Cited by 3
“The bone mineral density and elastic modulus of the vertebrae were approximately related to the CT value in a linear manner (Ciarelli et al. 1991; Rho et al. 1995; Zhang et al. 2017; Stolle et al. 2024), and were calculated using the following empirical formulas: where HU denotes the Hounsfield…”
Teng, H., Shao, B., & Liu, Z. (2023) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2023.2216825 · Cited by 3
“The elastic modulus was determined according to the empirical formula (1 – 2) (Carter and Hayes 1977; Ciarelli et al. 1991; Rho et al. 1995; Kopperdahl et al. 2002; Teng et al. 2021). where q is the bone density, Gv is the gravy value, E is Young ’ s modulus, and all the parameters were in SI units.”
MethodLuo, H., Teng, H., Shao, B., & Liu, Z. (2023) · Journal of Stomatology Oral and Maxillofacial Surgery · doi:10.1016/j.jormas.2023.101642 · Cited by 3
Araujo-Monsalvo, V. M., Toledo-Romo, M. F., Rodríguez-Castro, G. A., Vázquez-Escamilla, J., Domínguez‐Hernández, V. M., Meneses-Amador, A., Cortés-García, J. R., & Martínez-Coria, E. (2024) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119231221191 · Cited by 3
Zheng, C., Shu, J., Shao, B., & Liu, Z. (2024) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2024.2361778 · Cited by 3
“The Young’s modulus was calculated according to empirical formulas (Carter and Hayes 1977; Ciarelli et al. 1991; Harp et al. 1994; Rho et al. 1995).”
Hybrid additive manufacturing for Zn-Mg casting for biomedical application
Shahed, K. S., Fainor, M., Gullbrand, S. E., Hast, M. W., & Manogharan, G. P. (2024) · In vitro models · doi:10.1007/s44164-024-00077-0 · Cited by 3
“Young’s modulus of human bones ranges from 0.01 to 30 GPa [97, 98] which is lower when compared to Young’s modulus of Fe implant materials.”
InfluentialGersie, T., Bitter, T., Wolfson, D., Freeman, R., Verdonschot, N. J. J., & Janssen, D. W. (2025) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2025.104324 · Cited by 3
Finite Element Analysis of Human Tibia Modeled as a Functionally Graded Material
Tiwari, A., Wahi, P., & Sinha, N. (2019) · Journal of Engineering and Science in Medical Diagnostics and Therapy · doi:10.1115/1.4044054 · Cited by 3
Schneider, R. (2010) · Springer eBooks · doi:10.1007/978-3-642-11851-7_11 · Cited by 3
Mechanical Behavior of Trabecular Bone
Mostakhdemin, M. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-804634-0.00003-3 · Cited by 3
Heterogeneous modelling and finite element analysis of the femur
Zhang, B., Wang, X., Yu, Y., & Zheng, J. (2017) · MATEC Web of Conferences · doi:10.1051/matecconf/201713900055 · Cited by 3
Quantification of the microstructural anisotropy of distraction osteogenesis in the rabbit tibia.
Jones, K. B., Inoue, N., Tis, J. E., McCarthy, E. F., McHale, K. A., & Chao, E. Y. S. (2005) · Europe PMC (PubMed Central) · Cited by 3
Multi-scale Modelling of Orthotropic Properties of Trabecular Bone in Nanoscale
Khaterchi, H., Chamekh, A., & Belhadjsalah, H. (2013) · Lecture notes in mechanical engineering · doi:10.1007/978-3-642-37143-1_67 · Cited by 4
“3 Orthotropic Material Behaviour Many studies, for example (Ciarelli et al. 1991; Pithioux et al. 2002; Buskirk et al. 1981), show that the material properties of bone can be represented by an orthotropic material formulation.”
BackgroundUpper bill bending as an adaptation for nectar feeding in hummingbirdsPreprint
Rico‐Guevara, A., Sustaita, D., Hurme, K., Hannah, J. E., Jung, S., & Field, D. J. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.10.01.615288 · Cited by 3
Multiscale quantitative imaging of human femoral heads using X-ray microtomography
Ahmed, F. (2011) · OpenGrey (Institut de l'Information Scientifique et Technique) · Cited by 3
The Application of Advanced Bone Imaging Technologies in Sports Medicine
Tadros, S., Epsley, S., Mehta, S., Jones, B. C., Rajapakse, H. I., Madi, R., Alecxih, A. G., Kargilis, D., & Rajapakse, C. S. (2023) · Radiology Research and Practice · doi:10.1155/2023/7412540 · Cited by 4
“By assuming the material properties of bone, such as the elastic modulus, which has been shown to be related to voxel-specifc image intensities [41], the model can simulate how each of these constitutive elements would respond to a simulated loading condition, thereby enabling computation of the…”
MethodZuo, Q., Teng, H., Zhang, Y., Shao, B., & Liu, Z. P. (2026) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2025.2610676 · Cited by 2
Optimization of 3D printing parameters for PLGA/HA scaffolds using the Taguchi method
Gautam, K., Jimenez, H. G., Dikici, Y., Bensusan, J. S., Wnek, G. E., Rimnac, C. M., & Akkuş, O. (2026) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2026.107385 · Cited by 2
Correlation of elastic modulus and x-ray bone density in the area of the ankle joint
Omelchenko, T. M., Buryanov, О., Лябах, А. П., Mazevich, V., Shidlovsky, M., & Musienko, O. (2018) · ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS · doi:10.15674/0030-59872018380-84 · Cited by 2
Boyd, S. K., & Müller, R. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814841-9.00079-8 · Cited by 3
Evolution of implant placement in narrow alveolar ridge using Versah Drills
(2019) · Al-Azhar Journal of Dental Science · doi:10.21608/ajdsm.2019.108451 · Cited by 2
“Cancellous bone stiffness and strength are proportional to bone mineral density (14).”
BackgroundZeng, Y., Meng, Q., Chen, Y., Zou, D., & Tao, L. (2022) · Applied Sciences · doi:10.3390/app12146911 · Cited by 2
Owen, D. H., Wang, D., Xu, C., Mowbray, C., Perriman, D. M., Roberts, C. J., Smith, P. N., Drobetz, H., & Ackland, D. C. (2023) · Hand · doi:10.1177/15589447231198263 · Cited by 2
Zhang, H., Lv, J., Xü, X., Mei, J., & Liu, Y. (2024) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2024.104222 · Cited by 2
Kim, M.-S., Lee, H.-A., Kim, O., & Sohn, C. (2011) · Journal of Nutrition and Health · doi:10.4163/kjn.2011.44.6.481 · Cited by 2
Microstructural Assessment of Cancellous Bone Using 3D Microtomography
Silva, A. M. H., Alves, J. M., Silva, O. L. D., da Silva, N. F., Gazziro, M., Pereira, J. C., Lasso, P. R. O., Vaz, C. M. P., Pereira, C. A. M., Leiva, T. P., et al. (2011) · Journal of Physics Conference Series · doi:10.1088/1742-6596/313/1/012008 · Cited by 2
Moghaddam, A. O., Mahjoob, M. J., & Nazarian, A. (2016) · Cited by 2
Knörr, P., Schmittenbecher, P. P., Dietz, H.-G., Weinberg, A., & Castellani, C. (2006) · Springer eBooks · doi:10.1007/3-540-36006-9_13 · Cited by 2
The mechanical behavior of bone
Karim, L., Hussein, A. I., Vaidya, R., Morgan, E. F., & Bouxsein, M. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-813073-5.00013-7 · Cited by 4
(2019) · Ain Shams Dental Journal · doi:10.21608/asdj.2019.164505 · Cited by 2
Luo, H., Teng, H., Chong, D. Y. R., & Liu, Z. (2024) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3810 · Cited by 2
Automated Three Dimensional Finite Element Modeling Techniques of Bone and Bone Implant Systems
Merz, B. R., Müller, R., & Lengsfeld, M. (2003) · Springer eBooks · doi:10.1007/0-306-48329-7_10 · Cited by 2
Correlation between bone histomorphometry and bone strength
Jindal, M., Lakhwani, O. P., Kapoor, S., Chandoke, R., Kaur, O., Arora, B., & Garg, K. (2017) · Tropical Journal of Medical Research · doi:10.4103/1119-0388.198107 · Cited by 2
Computer-aided, pre-surgical analysis for oral rehabilitation
Cleynenbreugel, J. V., Puers, B., Naert, I. E., Sloten, J. V., Duyck, J. A. J., & Oosterwyck, H. V. (2003) · CRC Press eBooks · doi:10.1201/9780203514849.ch4 · Cited by 2
van Lenthe, H., & Huiskes, R. (1999) · Solid mechanics and its applications · doi:10.1007/0-306-46939-1_30 · Cited by 3
Kurata, K., HIGAKI, H., Miura, H., Mawatari, T., MURAKAMI, T., & Iwamoto, Y. (1999) · JSME International Journal Series C · doi:10.1299/jsmec.42.492 · Cited by 2
Anderson, D. (2005) · VTechWorks (Virginia Tech) · Cited by 2
Mirzaei, M., Jafari, R., Allaveisi, F., Jafari, H., & Alavi, F. (2022) · Journal of Orthopaedic Research® · doi:10.1002/jor.25404 · Cited by 1
A generalized objective CT-based method for quantifying articular fracture severity
Dibbern, K. N., Kern, A., & Anderson, D. D. (2024) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2024.112432 · Cited by 1
Seo, J., Jung, W.-S., Park, T. H., Lee, S.-J., Kwon, J.-W., Suk, K., & Lee, B. H. (2026) · Neurospine · doi:10.14245/ns.2551470.735 · Cited by 1
“29 It was assumed that the density was related to the Hounsfield units, us-ing the expression obtained from Rho et al. 30 Eq(1) ρ =-13.4+1017 HU (Hounsfield unit) (g/cm 3 ) The material properties were applied on the FE mesh, using the Mimics software where an average Young modulus was calculated…”
InfluentialBiomechanical evaluation of individual 3D-printed vertebrae
Metzner, F., Schleifenbaum, S., Heyde, C.-E., & von der Höh, N. H. (2026) · BMC Biomedical Engineering · doi:10.1186/s42490-026-00107-w · Cited by 1
“The exponent of the power equation lies within 1.3 and 1.5 which corresponds well with experimental findings comparing HU and compressive mechanical properties of human bone from various anatomical sites [43].”
InfluentialOverview of bone structure and strength
Unal, M., Jóhannesdóttir, F., & Bouxsein, M. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-13683-2.00046-3 · Cited by 1
Bone Mineral Density and Fracture Risk Assessment for Patients Undergoing Total Hip Replacement
Pétursson, Þ. (2014) · Cited by 1
王, 超., 樊, 瑜., 刘, 笑., 牛, 旭., 卢, 珊., 王, 丽., & 倪, 义. (2013) · Scientia Sinica Vitae · doi:10.1360/zc2013-43-8-626 · Cited by 1
Xing, H., Zou, R., Tang, X., Yi, M., Xie, Z., You, S., Liu, J., Zhang, Q., & Qin, Y. (2024) · Scientific Reports · doi:10.1038/s41598-024-55300-5 · Cited by 3
“The material values of the femur were assigned according to the following formula 45–48 : The final material parameters of the femur are shown in Table 1.”
MethodGarcía, J. S. J., del Olmo, N. S., Hutchinson, D. J., & Malkoch, M. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c09626 · Cited by 2
Magnetic Resonance of Bone Microstructure and Chemistry
Wehrli, F. W. (2011) · Elsevier eBooks · doi:10.1016/b978-0-08-055294-1.00108-2 · Cited by 1
Liefeith, K., Kaufhold, S., & Rost, J. (1998) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1998.43.6.179 · Cited by 1
Bonaretti, S., Seiler, C., Boichon, C., Büchler, P., & Reyes, M. (2011) · doi:10.7892/boris.4643 · Cited by 1
“In fact CT information and bone mechanical properties are strictly linked [22]: CT image grey levels represent the bone mineral density [8], which is related to the Young’s modulus through empirical relationships [12].”
BackgroundMoon, Y. L., Jung, S., Park, S. H., & Choi, G. Y. (2015) · Clinics in Shoulder and Elbow · doi:10.5397/cise.2015.18.2.86 · Cited by 1
Evaluation of local alterations in femoral bone mineral density measured via quantitative CT
Sitzer, A., Aulmann, L. F., Wendlandt, R., Heinz Handels, A., Weyers, I., Schulz, A., & Buzug, T. M. (2015) · Current Directions in Biomedical Engineering · doi:10.1515/cdbme-2015-0081 · Cited by 1
“For qCT-based BMD determination, most authors use machined bone samples or dissected bones without soft tissue [7, 8].”
BackgroundMethod3.24 Magnetic Resonance of Bone Microstructure and Chemistry ☆
Wehrli, F. W. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.10128-6 · Cited by 1
Simple anisotropic model of Bone Adaptation - SAMBA
Lipiński, P., Wroński, S., Tarasiuk, J., & Bonnet, A.-S. (2022) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2022.105217 · Cited by 1
Quantitative image processing of 3D biological structures
Müller, R. (2003) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2002.1029275 · Cited by 1
Wehrli, F. W. (1996) · doi:10.1002/9780470034590.emrstm0227 · Cited by 1
Alteration of Mechanical Properties of Remodeling Bone Adapted to Mechanical Stimuli.
Kurata, K., HIGAKI, H., Miura, H., MURAKAMI, T., & Iwamoto, Y. (2000) · JSME International Journal Series C · doi:10.1299/jsmec.43.822 · Cited by 1
Dynamic Finite Element Analysis of Cancellous Bone Micro Structure
Schneider, R., Hindenlang, U., & Copf, P. (2011) · Notes on numerical fluid mechanics and multidisciplinary design · doi:10.1007/978-3-642-17770-5_25 · Cited by 1
Computer-aided, pre-surgical analysis for oral rehabilitation
Oosterwyck, H. V., Sloten, J. V., Duyck, J. A. J., Cleynenbreugel, J. V., Puers, B., & Naert, I. (2003) · CRC Press eBooks · doi:10.1201/9780203514849-7 · Cited by 1
Maciel, J. G. (2022) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.17.2022.tde-06052022-162050 · Cited by 1
Gersie, T., Bitter, T., Wolfson, D., Freeman, R., Verdonschot, N. J. J., & Janssen, D. W. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4706264 · Cited by 1
Kurata, K., HIGAKI, H., Miura, H., Mawatari, T., MURAKAMI, T., & Iwamoto, Y. (2002) · JSME International Journal Series C · doi:10.1299/jsmec.45.558
Correlating mechanical properties of cancellous bone in the rat with various density measures
Ramaswamy, R. (2004) · OakTrust (Texas A&M University Libraries)
Ultrasonografia ossea quantitativa
Albanese, C. V. (2009) · Springer eBooks · doi:10.1007/978-88-470-1357-5_42
Computational Problems in Orthopaedic Biomechanics
Taylor, D. L. (1993) · MRS Proceedings · doi:10.1557/proc-323-221
Schneider, P., Voide, R., Stampanoni, M., & Müller, R. (2008) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.772668 · Cited by 1
Pressel, T. (2010) · Orthopedic Research and Reviews · doi:10.2147/orr.s8265
Cristiana, R., & Tanasoca, M. (2006)
Bone Strength Multi-axial Behavior - Volume Fraction, Anisotropy and Microarchitecture
Sanyal, A. (2013) · eScholarship (California Digital Library)
Prevalencia de fractura vertebral en la población prehispánica de El Hierro.
Reimers, E. G., de la Rosa, M. M. A., & Pascual, A. M. (2008) · Acceda (Universidad de Las Palmas de Gran Canaria)
Anderson, J. C., & Paulos, L. E. (2008) · Elsevier eBooks · doi:10.1016/b978-1-4160-3834-4.10037-x
QUANTITATIVE MAPPING IN MAGNETIC RESONANCE IMAGING
Wang, G. (2016)
Kinematics of the Anterior Cruciate Ligament (ACL) and ACL Graft
Zhu, J. (2018) · D-Scholarship@Pitt (University of Pittsburgh) · Cited by 1
Mechanics of Biosolids and Computational Analysis
Tanaka, M., Wada, S., & Nakamura, M. (2012) · Springer eBooks · doi:10.1007/978-4-431-54073-1_2
Monotonic and cyclic behaviour of trabecular bone under uniaxial and multiaxial loading
Januddi, M. S., & Januddi, M. A. F. M. S. (2015)
Long, E. B., Barak, M. M., & Frost, V. J. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.105000
Engbretson, A. C. (2010) · QSpace (Queen's University Library)
Study of DXA-derived cortical bone thickness in assessing hip fracture risk
Long, Y. (2014) · Mspace (University of Manitoba) · Cited by 1
A biomechanical study of a novel biomimetic hip implant
Khurshid, S. (2021) · doi:10.32920/ryerson.14647719.v1 · Cited by 1
Oftadeh, R. (2015) · Digital Repository Service (Northeastern University) · doi:10.17760/d20212379
(2018) · Elsevier eBooks · doi:10.1016/b978-3-437-22102-6.00001-9 · Cited by 1
Pandithevan, P., & Prasannavenkadesan, V. (2023) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519423500628
Towards the simulation of bone-implant systems with a stratified material model
Schnabel, B., Gebert, J., Schneider, R., & Helwig, P. (2023) · Technology and Health Care · doi:10.3233/thc-237001
“…modeling on the basis of CT data, the literature of the past decades shows a path leading from analytical approaches [18] and experimental methods [19] over material data determination via data-processing-based approaches directly applied to clinical CT data [20], to simulation-based approaches…”
Scott, J. W., Ng, K. C. G., Liddle, A. D., & Jeffers, J. R. T. (2024) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2024.106240
Processing of Silicon Nitride Bioceramics
McEntire, B. J. (2024) · Springer eBooks · doi:10.1007/978-3-031-67047-3_3
Zuo, Q., Teng, H., Chong, D. Y. R., & Liu, Z. (2025) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2025.08.004 · Cited by 1
Additive manufacturing of biomedical metal alloys
Ibrahim, P., & Attallah, M. M. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-28820-3.00009-3
Three-dimensional analysis of bone cellular tissue from SR CT Imaging
Dong, P. (2014) · theses.fr (ABES) · doi:10.70675/333ad040z2624z4a1dzad8dz8c67f8a4e581 · Cited by 2
youssef, M. (2012) · theses.fr (ABES) · doi:10.70675/14a1847fz15e6z44efz9f09z00eefea3e51d · Cited by 1
Shu, J., Zhang, S. L., & Li, L. C. (2026) · BMC Oral Health · doi:10.1186/s12903-026-08757-x
Lorenz, J. M., Molinuevo, M. S., Melluso, E. P., Kang, K. W., Gangoiti, M. V., & Peruzzo, P. J. (2026) · Polymer Engineering and Science · doi:10.1002/pen.70649
Zuo, Q., Teng, H., Zhang, Y., & Liu, Z. (2026) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2026.10.003
Relationship between BMD, apparent and ASH dunsity of human trabecular bone
Mazurkiewicz, A., & Topoliński, T. (2010) · Journal of Polish CIMAC/Journal of Polish CIMEEAC
Patellar tracking in the total knee joint replacement model with patellar retinaculum
Jansová, M., Křen, J., Pokorný, J., & Koudela, K. (2011) · Modelling and Optimization of Physical Systems
Simulazione numerica del rimodellamento osseo in un sistema bacino-cotile
Faluci, A., Bignardi, C., & Calderale, P. M. (2009) · PORTO Publications Open Repository TOrino (Politecnico di Torino)
Metadata
- Authors
- Ciarelli, M. J., Goldstein, S. A., Kuhn, J. L., Cody, D. D., & Brown, M. B.
- Affiliations
- University of Michigan (US)
- Henry Ford Health (US)
- Corresponding author
- Goldstein, S. A.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1991-09
- Volume
- 9
- Issue
- 5
- Pages
- 674-682
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2048282929
- Cited by
- 401
- References
- 28
- Citations by year
- 2026: 10 · 2025: 6 · 2024: 16 · 2023: 21 · 2022: 7 · 2021: 12 · 2020: 13 · 2019: 9 · 2018: 12 · 2017: 8 · 2016: 8 · 2015: 7 · 2014: 17 · 2013: 14 · 2012: 11
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Orthopaedic Research® (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01ar034399-12)
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR34399)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- trabecular bone, bone mineral density, elastic modulus, uniaxial compression, flexural failure, trabecular bone microarchitecture, cadaveric bone, tibia, femur, radius, humerus, bone strength
- MeSH terms
- Aged, Biomechanical Phenomena, Bone and Bones, Humans, Male, Middle Aged, Tomography, X-Ray Computed, Bone Density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.