Evaluation of orthogonal mechanical properties and density of human trabecular bone from the major metaphyseal regions with materials testing and computed tomography
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
We evaluated the orthogonal mechanical properties of human trabecular bone from the major metaphyseal regions with materials testing and quantitative computed tomography (CT). The proximal tibia, distal femur, proximal femur, distal radius, and proximal humerus from fresh cadaver specimens between the ages of 55 and 70 years were excised and prepared for experimentation. The bones were embedded and scanned at 1 or 1.5 mm intervals on a Technicare HPS 1440 and GE 9800 CT scanner. After scanning, the bones were sectioned, producing 8‐mm cubes of trabecular bone which were mechanically tested in uniaxial compression at a strain rate of 1%/s. The testing sequence consisted of preyield tests in two of the three orthogonal directions and failure in the third. After testing, the cubes were evaluated for apparent density and ash weight. The results of the study show that the strength and stiffness of trabecular bone varies significantly within metaphyseal regions and from metaphysis to metaphysis. The power and significance of relationships between density and modulus varied as a function of metaphyseal location. Both linear and nonlinear models were significant, suggesting that trabecular deformation occurs in response to both axial and bending loads. Finally, the need for architectural measures of trabecular bone to predict mechanical properties is emphasized.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.1–30 MPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [89]
In the citing paper
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.1–30 MPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [89]
In the citing paper
“Typically, the modulus of human trabecular bone ranges between 10 and 3,000 MPa, whereas strength, which is linearly and strongly correlated with modulus (82, 89), is generally two orders of magnitude smaller, in the range 0.1–30 MPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [89]
In the citing paper
“The anisotropy that trabecular bone exhibits in microstructure is also present in elastic modulus (89) and strength (92).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [89]
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
The mechanics of three-dimensional cellular materials
Gibson, I. J., & Ashby, M. F. (1982) · Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences · doi:10.1098/rspa.1982.0088 · Cited by 1,885
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
The mechanical properties of trabecular bone: Dependence on anatomic location and function
Goldstein, S. A. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90023-6 · Cited by 687
Self-citationPrediction of vertebral body compressive fracture using quantitative computed tomography.
McBroom, R. J., Hayes, W. C., Edwards, W. T., Goldberg, R. P., & White, A. A. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567080-00010 · Cited by 432
Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial Epiphysis
Williams, J. L., & Lewis, J. L. (1982) · Journal of Biomechanical Engineering · doi:10.1115/1.3138303 · Cited by 415
Physical properties of trabecular bone
Galante, J., Rostoker, W., & Ray, R. D. (1970) · Calcified Tissue Research · doi:10.1007/bf02017552 · Cited by 302
The mechanical properties of human tibial trabecular bone as a function of metaphyseal location
Goldstein, S. A., Wilson, D. L., Sonstegard, D. A., & Matthews, L. S. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90097-0 · Cited by 292
Self-citationMechanical Properties of Trabecular Bone from the Proximal Femur: A Quantitative CT Study
Lotz, J. C., Gerhart, T. N., & Hayes, W. C. (1990) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199001000-00020 · Cited by 284
Research works printed but not linked: 4
- Evans FG, 1961, Biomechanical Studies of the Musculoskeletal System, 49
- Wolff J, 1892, Das Gestez der Transformation der Knochen
- Yokoo S, 1952, Compression test of the cancellous bone, J Kyoto Pref Med Univ, 51, 273
- Arnold JS, 1960, Quantitation of mineralization of bone as an orgen and tissue in osteoporosis, Clin Orthop, 17, 167
Cited by
Items 201–300 of 400
El-Gizawy, A. S., Ma, X., Pfeiffer, F. M., Schiffbauer, J. D., & Selly, T. (2023) · BioMed · doi:10.3390/biomed3010007 · Cited by 18
“Clinical CT and micro-CT images are a pixel map of the linear X-ray attenuation coefficient of scanned material that reflects the level of beam attenuation due to sample density [1,11,12,15,16].”
BackgroundBlumenfeld, J., Studholme, C., Carballido‐Gamio, J., Carpenter, R. D., Link, T. M., & Majumdar, S. (2008) · Medical Physics · doi:10.1118/1.2977764 · Cited by 18
Rho, J. Y., Zerwekh, J. E., & ASHMAN, R. B. (1994) · Clinical Biomechanics · doi:10.1016/0268-0033(94)90026-4 · Cited by 19
Li, A., Shao, B., & Liu, Z. (2021) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2021.1939316 · Cited by 17
“According to previous research, the density and Young’s elastic modulus were calculated based on the empirical formulas using Hounsfield units (Ciarelli et al. 1991; Harp et al. 1994; Rho 1995; Kopperdahl et al. 2010; Shu et al. 2018).”
MethodSmith, A. N., Ulsh, J. B., Gupta, R., Tang, M. M., Peredo, A. P., Teinturier, T. D., Mauck, R. L., Gullbrand, S. E., & Hast, M. W. (2023) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2024.106457 · Cited by 21
Biomechanics of the Human Osteochondral Unit: A Systematic Review
Berni, M., Marchiori, G., Baleani, M., Giavaresi, G., & Lopomo, N. F. (2024) · Materials · doi:10.3390/ma17071698 · Cited by 27
“A great effect of the angle between the testing direction and the main direction of the bone structure on the compressive behaviour is highlighted, suggesting that the anisotropy exhibited by the microstructure of the TB reflects on its elastic response [158,159].”
BackgroundSoodmand, I., Becker, A.-K., Saß, J., Jabs, C., Kebbach, M., Wanke, G., Dau, M., & Bader, R. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e40668 · Cited by 22
Vivanco, J. F., Burgers, T., García-Rodríguez, S., Crookshank, M. C., Kunz, M., MacIntyre, N. J., Harrison, M. M., Bryant, J. T., Sellens, R., & Ploeg, H. (2014) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411914540285 · Cited by 22
“7, b = 61–88 mg/cm(3)).(16,30,33) Strong correlations between rash and rCT for human trabecular bone have been found by several research groups (R(2) = 0.”
BackgroundBiswas, J. K., Dey, S., Karmakar, S. K., Chowdhury, A. R., & Datta, S. (2018) · Current Medical Imaging Formerly Current Medical Imaging Reviews · doi:10.2174/1573405614666181018122538 · Cited by 17
Pairwise strength relationships of cortical and cancellous bone in human femur: an autopsy study
Alho, A. V., Str�ms�e, K., & H�iseth, A. (1995) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/bf00444265 · Cited by 17
Correlation of quantitative computed tomographic subchondral bone density and ash density in horses
DRUM, M. G., Les, C. M., Park, R. D., Norrdin, R. W., McIlwraith, C. W., & Kawcak, C. E. (2008) · Bone · doi:10.1016/j.bone.2008.08.129 · Cited by 17
“Although there has been a report of good correlations with precut QCT bone density values to apparent ash density [1], it was unknown if this relationship existed with equine subchondral bone.”
BackgroundLo, I. K. Y., King, G. J. W., PATTERSON, S. D., Johnson, J. A., & Chess, D. G. (2001) · Journal of Hand Surgery (European Volume) · doi:10.1054/jhsb.2000.0481 · Cited by 16
“We measured the elastic modulus of trabecular bone from the waist (osteotomy wafer) of each scaphoid using an established technique (Ciarelli et al., 1991; Lo et al., 1998).”
MethodEmadi, N., Safi, Y., Baghban, A. A., & Asgary, S. (2014) · Iranian endodontic Journal/Iranian endodontic journal. · doi:10.22037/iej.v9i4.5644 · Cited by 16
“The technology was introduced in 1978 for bone density [7].”
BackgroundAutomatic Prospective Registration of High-Resolution Trabecular Bone Images of the Tibia
Blumenfeld, J., Carballido‐Gamio, J., Krug, R., Blezek, D. J., Hancu, I., & Majumdar, S. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9365-z · Cited by 16
Factores determinantes de la resistencia ósea
Rey, J. R. C., Robleda, S. D., Vaquero-Cervino, E., Ruiz, L. R., & Ramos, M. Á. B. (2005) · Revista Española de Enfermedades Metabólicas Óseas · doi:10.1016/s1132-8460(05)72686-6 · Cited by 15
Sun, T., Chong, D. Y. R., Shao, B., & Liu, Z. (2023) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2023.107336 · Cited by 15
Storlino, G., Dicarlo, M., Zerlotin, R., Pignataro, P., Sanesi, L., Suriano, C., Oranger, A., Mori, G., Passeri, G., Colucci, S. C., et al. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24129896 · Cited by 17
“However, new evidence has highlighted that mechanical properties may also be predicted using architectural measures of trabecular bone [47,48].”
BackgroundO’Leary, M. A., Patel, B. A., & Coleman, M. N. (2011) · Journal of Paleontology · doi:10.1666/10-091.1 · Cited by 15
“Radiographic techniques such as CT, however, can be applied to estimate relative (or apparent) density within and between individuals (Ciarelli et al., 1991; Snyder and Schneider, 1991; Patel and Carlson, 2007; Drum et al., 2009) without damaging original material.”
BackgroundThe Mechanical Behavior of Bone
Karim, L., Hussein, A. I., Morgan, E. F., & Bouxsein, M. (2013) · Elsevier eBooks · doi:10.1016/b978-0-12-415853-5.00019-4 · Cited by 22
A Biomechanical Analysis of Intrascaphoid Compression Using the Herbert Scaphoid Screw System
Lo, I. K. Y., King, G. J. W., Milne, A. D., Johnson, J. A., & CHESS, D. C. (1998) · Journal of Hand Surgery (European Volume) · doi:10.1016/s0266-7681(98)80176-9 · Cited by 15
Goldstein, S. A., Frankenburg, E. P., & Kuhn, J. L. (1993) · Springer eBooks · doi:10.1007/978-1-4757-2264-2_9 · Cited by 15
Self-citationNew architectural parameters derived from micro-MRI for the prediction of trabecular bone strength
Wehrli, F. W., Hwang, S. N., & Song, H. K. (1998) · Technology and Health Care · doi:10.3233/thc-1998-65-604 · Cited by 23
“There is theoretical [1], experimental (e.g., [2,3]) and clinical evidence [4,5] for the role of architecture as a significant determinant of bone strength.”
Grottoli, C. F., Cingolani, A., Zambon, F., Ferracini, R., Villa, T. M. T., & Perale, G. (2019) · Journal of Functional Biomaterials · doi:10.3390/jfb10040053 · Cited by 14
“These values were obtained through the following equations [56]:”
MethodHow do Cats Resist Landing Injury: Insights into the Multi-level Buffering Mechanism
Wu, X., Pei, B., Pei, Y., Wang, W., Yan, H., & Zhou, K. (2020) · Journal of Bionic Engineering · doi:10.1007/s42235-020-0048-x · Cited by 14
Adamu, M. A., Sumaila, M., Dauda, M., & Ause, T. (2023) · Scientific African · doi:10.1016/j.sciaf.2023.e01563 · Cited by 14
Computational Nanomechanics of Noncollagenous Interfibrillar Interface in Bone
Wang, Y., Morsali, S. R., Dai, Z., Minary‐Jolandan, M., & Qian, D. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c01613 · Cited by 16
Kagan, J. (1998) · Disease Markers · doi:10.1155/1998/698239 · Cited by 23
Teng, H., Shu, J., Wang, Q., Shao, B., Zheng, T., & Liu, Z. (2021) · Medicine · doi:10.1097/md.0000000000024540 · Cited by 13
An Innovative CCD-Based High-Resolution CT System for Analysis of Trabecular Bone Tissue
Baruffaldi, F., Bettuzzi, M., Bianconi, D., Brancaccio, R., Cornacchia, S., Lanconelli, N., Mancini, L., Morigi, M. P., Pasini, A., Perilli, E., et al. (2006) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2006.876047 · Cited by 13
“bone to be correlated to the trabecular microstructure [12]–[14].”
BackgroundBiomechanics of Age-Related Fractures
Bouxsein, M. (2008) · Elsevier eBooks · doi:10.1016/b978-012370544-0.50025-2 · Cited by 25
Park, T. H., Woo, S. H., Lee, S. J., Sohn, D. M., Chung, C. K., Kim, Y. J., & Sohn, S. (2019) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2019.04.036 · Cited by 12
Optimal Principle of Bone Structure
Fan, Y., Fan, Y., Li, Z., Loan, M., Lv, C., & Bo, Z. (2011) · PLoS ONE · doi:10.1371/journal.pone.0028868 · Cited by 12
“Following [24, 25], we separate foot bone to calculate the volume, surface area and average bone density (Table 1).”
MethodTomography of human trabecular bone with a laser-wakefield driven x-ray source
Cole, J. M., Wood, J. C., Lopes, N., Põder, K., Abel, R. L., Alatabi, S., Bryant, J., Jin, A., Kneip, S., Mecseki, K., et al. (2015) · Plasma Physics and Controlled Fusion · doi:10.1088/0741-3335/58/1/014008 · Cited by 10
Dibbern, K. N., Kempton, L. B., Higgins, T. F., Morshed, S., McKinley, T. O., Marsh, J. L., & Anderson, D. D. (2016) · Journal of Orthopaedic Research® · doi:10.1002/jor.23359 · Cited by 11
“Bone densities were estimated from the CT Hounsfield intensities at each CT scan pixel using previously established relationships.(18,19) The location-specific bone density was then used to appropriately scale fracture-liberated surface areas by density-dependent energy release rates to obtain the fracture energy.”
Andrade, N. N., Aggrawal, N., Jadhav, G., Sahu, V., & Mathai, P. C. (2018) · Journal of Oral Biology and Craniofacial Research · doi:10.1016/j.jobcr.2018.04.005 · Cited by 11
Inacio, J. V., Malige, A., Schroeder, J. T., Nwachuku, C. O., & Dailey, H. L. (2019) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2019.04.014 · Cited by 11
Wang, G., Fu, Y., Shea, S. M., Hegde, S. S., & Kraitchman, D. L. (2018) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-018-0728-2 · Cited by 11
Engelke, K., & Kalender, W. A. (1998) · Springer eBooks · doi:10.1007/978-3-642-80440-3_21 · Cited by 11
Representation of bone heterogeneity in subject-specific finite element models for knee
Au, A. G., Liggins, A. B., Raso, V. J., Carey, J. P., & Amirfazli, A. (2009) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2009.11.009 · Cited by 10
“The mechanical properties of bone tissue in the knee are widely recognized as being anisotropic rather than isotropic [5,16].”
BackgroundAdamu, M. A., Sumaila, M., Dauda, M., & Ause, T. (2023) · Iranian Polymer Journal · doi:10.1007/s13726-023-01248-8 · Cited by 11
“The density reported in the work is near to the human bone density reported by Ciarelli et al. [24].”
Drum, M. G., Les, C. M., Park, R. D., McIlwraith, C. W., & Kawcak, C. E. (2008) · American Journal of Veterinary Research · doi:10.2460/ajvr.69.7.891 · Cited by 10
Yan, Y., QI, W., Qiu, T.-X., Teo, E.-C., & Lei, W. (2012) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519412500923 · Cited by 10
Ghouchani, A., Rouhi, G., & Ebrahimzadeh, M. A. (2019) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2019.103360 · Cited by 10
Biswas, J. K., Kalita, K., & Roychowdhury, A. (2020) · Engineering With Computers · doi:10.1007/s00366-020-01090-z · Cited by 10
Sensitivity analysis of a cemented hip stem to implant position and cement mantle thickness
Shi, J., Browne, M., Strickland, M. A., Flivik, G., & Taylor, M. (2013) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2012.761693 · Cited by 10
“Both cancellous and cortical bone were modelled as elastic and isotropic, as opposed to anisotropic (Ciarelli et al. 1991; Keaveny et al. 2001), and the failure-criterion is not well-defined for these materials.”
BackgroundVirtual trabecular bone models and their mechanical response
Donaldson, F. E., Pankaj, P., Law, A., & Simpson, H. (2008) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim408 · Cited by 15
Barth, J. R. H., Akritopoulos, P., Graveleau, N., Barthélémy, R., Toanen, C., & Saffarini, M. (2016) · Orthopaedic Journal of Sports Medicine · doi:10.1177/2325967116647724 · Cited by 10
“0227 None, unchanged 15 (100) 11 (92) 7 (58) 2 (13) Figure-of-8 0 (0) 1 (8) 2 (17) 10 (67) Enlarged at some levels 0 (0) 0 (0) 1 (8) 1 (7) Wide at all levels 0 (0) 0 (0) 2 (17) 2 (13) Cortical formation NS <.”
Kaminsky, J., Rodt, T., Gharabaghi, A., Forster, J., Brand, G., & Samii, M. (2005) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.10.004 · Cited by 10
Bone Quality: The Mechanical Effects of Microarchitecture and Matrix Properties
Day, J. S. (2005) · EUR Research Repository (Erasmus University Rotterdam) · Cited by 16
Moosabeiki, V., Winter, N., Saldívar, M. C., Leeflang, M. A., Witbreuk, M. M. E. H., Lagerburg, V., Mirzaali, M. J., & ZADPOOR, A. A. (2023) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2023.106173 · Cited by 9
Kechagias, S., Munford, M. J., Masure, F. C. H., van Arkel, R. J., & Oosterbeek, R. N. (2026) · Advanced Materials Technologies · doi:10.1002/admt.202501885 · Cited by 15
Shu, J., Xiong, X., Chong, D. Y. R., Liu, Y., & Liu, Z. (2020) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411920962392 · Cited by 9
A novel method of estimating structure model index from gray-level images
Tabor, Z. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.10.005 · Cited by 10
“It follows from experimental studies that only 0–80% of the variance of trabecular bone strength measured in itro can be explained by bone density alone while the remainer is attributed to the properties of trabecular bone architecture nd material properties [3].”
BackgroundBone Density versus Bone Quality as a Predictor of Bone Strength
Jindal, M. (2018) · Orthopedics and Rheumatology Open Access Journal · doi:10.19080/oroaj.2018.12.555830 · Cited by 8
Gupta, A., Rana, M., Mondal, N., Das, A., Karmakar, A., & Chowdhury, A. R. (2022) · International Journal for Multiscale Computational Engineering · doi:10.1615/intjmultcompeng.2022043461 · Cited by 9
Kubo, Y., Gonzalez, J. A. H., Beckmann, R., Weiler, M., Pahlavani, H., Saldívar, M. C., Szymanski, K., Rosenhain, S., Fragoulis, A., Leeflang, M. A., et al. (2022) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-022-05942-1 · Cited by 10
Wehrli, F. W., Hwang, S. N., Song, H. K., & Gomberg, B. R. (2001) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-0651-5_16 · Cited by 9
Novel techniques for high-resolution functional imaging of trabecular bone
Thurner, P. J., Müller, R., Kindt, J. H., Schitter, G., Fantner, G. E., Wyss, P., Sennhauser, U. J., & Hansma, P. K. (2005) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.595799 · Cited by 9
Initial fixation of a femoral knee component: an in vitro and finite element study
Burgers, T., Mason, J., & Ploeg, H. (2009) · International Journal of Experimental and Computational Biomechanics · doi:10.1504/ijecb.2009.022857 · Cited by 10
“…provided by Rho et al. (1.79) (Rho et al., 1995) is similar to that reported by Ciarelli et al. (1.78) in the AP direction of the distal femur (Ciarelli et al., 1991) and Morgan et al. (1.49-1.93) in the principal trabecular orientation at different anatomical sites (Morgan et al., 2003).”
InfluentialOverview of Bone Structure and Strength
Bouxsein, M. (2012) · Elsevier eBooks · doi:10.1016/b978-0-12-387829-8.00002-0 · Cited by 12
Subchondral bone density of the radial head measured with subtraction densitometry
Koslowsky, T. C., Mader, K., Brandenburg, A., Hellmich, M., & Koebke, J. (2008) · Surgical and Radiologic Anatomy · doi:10.1007/s00276-007-0299-9 · Cited by 9
Upper bill bending as an adaptation for nectar feeding in hummingbirds
Rico‐Guevara, A., Sustaita, D., Hurme, K., Hanna, J. E., Jung, S., & Field, D. J. (2024) · Journal of The Royal Society Interface · doi:10.1098/rsif.2024.0286 · Cited by 8
“[71] to estimate E averaged across all three orthogonal directions from mineral density.”
Effects of loading rate, age, and morphology on the material properties of human rib trabecular bone
Albert, D. L., Katzenberger, M. J., Hunter, R. L., Agnew, A. M., & Kemper, A. R. (2023) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111670 · Cited by 9
Gíslason, M. K., Ingvarsson, P. E., Gargiulo, P., Yngvason, S., Gudmundsdóttir, V., Knútsdóttir, S., & Helgason, Þ. (2014) · European Journal of Translational Myology · doi:10.4081/ejtm.2014.2187 · Cited by 8
Impact of mandibular prognathism on morphology and loadings in temporomandibular joints
Shu, J., Wang, Q., Chong, D. Y. R., & Liu, Z. (2020) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2019-0298 · Cited by 8
Luo, H., Teng, H., Chong, D. Y. R., & Liu, Z. (2023) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-023-02785-3 · Cited by 7
Vale, A. C., Pereira, M. F. C., Maurício, A., Vidal, B., Rodrigues, A. M., Caetano‐Lopes, J., Nazarian, A., Fonseca, J. E., Canhão, H. M., & Vaz, M. F. (2013) · Journal of Biomedical Science and Engineering · doi:10.4236/jbise.2013.62021 · Cited by 7
“Micro-computed tomography (micro-CT) has become an important tool to the visualization and quantification of the three-dimensional (3D) structure of bone [1-15] instead of inferring the properties from 2D measurements, which is the case of histomorphometric evaluation.”
BackgroundKempton, L. B., Dibbern, K. N., Anderson, D. D., Morshed, S., Higgins, T. F., Marsh, J. L., & McKinley, T. O. (2016) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0000000000000636 · Cited by 7
Development and Application of Ultrasound Backscatter Methods for the Diagnostics of Trabecular Bone
Riekkinen, O. (2008) · Cited by 7
Letter to the Editor: On hydraulic strengthening of bones
Bryant, J. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)90563-l · Cited by 7
A validated finite element study of stress shielding in a novel hybrid knee implant
Mahboob, Z. (2021) · doi:10.32920/ryerson.14649990.v1 · Cited by 7
Ding, Z., Wang, J., Wang, Y., Zhang, X., Huan, Y., & Zhang, D. (2023) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-023-06205-3 · Cited by 6
“The HU values for each gradient were therefore converted to elastic modulus with the following linear relationship [21, 22]:”
MethodHwang, P., Kao, T.-T., Guo-Yu, T., Hsu, F., & Chang, C.-H. (2023) · Journal of Functional Foods · doi:10.1016/j.jff.2023.105882 · Cited by 7
Functional microimaging: an integrated approach for advanced bone biomechanics and failure analysis
Voide, R., van Lenthe, H., Schneider, P., Thurner, P. J., Wyss, P., Sennhauser, U. J., Stampanoni, M., Stauber, M., Snedeker, J. G., & Müller, R. (2006) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.650485 · Cited by 8
“However, changes in mass can only partially explain the variation of trabecular bone strength of individuals leaving sometimes up to 90% of the strength variation unexplained [10].”
BackgroundDEVELOPMENT OF IN-SITU TEMPERATURE PREDICTION MODELS FROM CADAVERIC HUMAN FEMUR FOR BONE DRILLING
Pandithevan, P., Pandy, N. V. M., & PALANIVEL, C. (2018) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519418500264 · Cited by 6
Shore, S. W., Unnikrishnan, G. U., Hussein, A. I., & Morgan, E. F. (2012) · CRC Press eBooks · doi:10.1201/b13733-3 · Cited by 8
Functional Micro-imaging at the Interface of Bone Mechanics and Biology
Müller, R., Nazarian, A., Schneider, P., Stauber, M., Thurner, P. J., van Lenthe, H., & Voide, R. (2006) · Springer eBooks · doi:10.1007/3-540-31184-x_34 · Cited by 6
Mechanical Behaviour of Cancellous bone: Compression and Three-Point Bending Test
Ghazali, F. A. M., & Syahrom, A. (2022) · Malaysian Journal of Fundamental and Applied Sciences · doi:10.11113/mjfas.v18n3.2274 · Cited by 5
Ibrahim, P., Jameekornkul, P., Panesar, A. S., & Attallah, M. M. (2025) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2025.106999 · Cited by 8
Saghaei, Z., & Hashemi, A. (2023) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119221144811 · Cited by 5
Gunter, T., Merz, B., Mericske‐Stern, R., Schmitt, J., Leppek, R., & Lengesfeld, M. (2000) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.2000.45.10.272 · Cited by 5
Pressel, T., Lengsfeld, M., Leppek, R., & Schmitt, J. (2000) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s004020050476 · Cited by 5
Development and Validation of an Analogue Lumbar Spine Model and its Integral Components
Domann, J. P. (2011) · KU ScholarWorks (The University of Kansas) · Cited by 9
Teng, H., Shu, J., Ma, H., Shao, B., & Liu, Z. (2024) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2024.104195 · Cited by 4
The elastic moduli and fatigue properties of canine trabecular bone tissue
Choi, K., Khang, G., & Goldstein, S. A. (2001) · KSME International Journal · doi:10.1007/bf03185280 · Cited by 5
Self-citationCornu, O., Manil, O., Godts, B., Naets, B., Tomme, J. V., Delloye, C., & Banse, X. (2004) · Acta Orthopaedica Scandinavica · doi:10.1080/00016470410001231 · Cited by 4
“Differences in the mechanical behavior and final density previously observed by us were thought to be related to the bone quality of the individual donor (Brown and Ferguson 1980, Goldstein 1987, Ciarelli et al. 1991).”
BackgroundPerilli, E., Baleani, M., Raatjes, W., Baruffaldi, F., Cappello, A., & Toni, A. (2005) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519405001473 · Cited by 4
Gíslason, M. K., Ingvarsson, P. E., Gargiulo, P., Yngvason, S., Gudmundsdóttir, V., Knútsdóttir, S., & Helgason, Þ. (2014) · European Journal of Translational Myology · doi:10.4081/bam.2014.3.187 · Cited by 4
Effect of pre-stress on dynamic finite element analysis of the temporomandibular joint
Teng, H., Shu, J., Ma, H., Shao, B., & Liu, Z. (2023) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2023.2290455 · Cited by 4
“(1)(2)), the density and elastic modulus were assigned to the maxilla and mandible to simulate the heterogeneous isotropic linear elasticity (Carter and Hayes 1977; Ciarelli et al. 1991; Harp et al. 1994; Rho et al. 1995; Kopperdahl et al. 2002; Shu et al. 2020).”
Overview of Bone Structure and Strength
Jóhannesdóttir, F., & Bouxsein, M. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-804182-6.00012-5 · Cited by 8
Biomechanical effects of high acceleration on the temporomandibular joint
Luo, H., Shu, J., & Liu, Z. (2021) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2021.1955105 · Cited by 4
“The material properties of the bone structures in our study were assigned according to empirical formulas between the gray values and the material properties of the bone in CT (Table 1) (Ciarelli et al. 1991; Harp et al. 1994; Rho et al. 1995; Hobatho et al. 1997; Bennison et al. 2021).”
Methodvan Staden, R., Guan, H., Loo, Y., Johnson, N., & Meredith, N. (2007) · Cited by 4
3D GRAY-LEVEL HISTOMORPHOMETRY OF TRABECULAR BONE - A METHODOLOGICAL REVIEW
Tabor, Z., & Latała, Z. (2014) · Image Analysis & Stereology · doi:10.5566/ias.v33.p1-12 · Cited by 5
Lian, Z., Gu, Y., & Zhang, H. (2008) · Multidiscipline Modeling in Materials and Structures · doi:10.1163/157361108785963019 · Cited by 4
Evaluation of CT accuracy in orthopaedic implants geometry reconstruction
Zannoni, C., Viceconti, M., Pierotti, L., & Cappello, A. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1997.757096 · Cited by 4
A high order fictitious domain method for patient specific surgery planning
Duester, A., Parvizian, J., Yang, Z., & Rank, E. (2007) · Cited by 4
Simulated aging—a novel method for estimating the risk of fracture of trabecular bone
Tabor, Z. (2003) · Bone · doi:10.1016/s8756-3282(03)00224-2 · Cited by 5
“It also follows from experimental studies that only 40–80% of the variance of trabecular bone strength measured in vitro can be explained by bone density alone, while the remainder is attributed to the trabecular bone mass distribution [4].”
BackgroundFunctional micro-imaging of soft and hard tissue using synchrotron light
Thurner, P. J., Wyss, P., Voide, R., Stauber, M., Müller, B., Stampanoni, M., Hubbell, J. A., Müller, R., & Sennhauser, U. J. (2004) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.559515 · Cited by 7
“Where strong correlations between bone density and mechanical properties of trabecular bone have been demonstrated for large populations using power-law regressions (9-15), changes in density can explain only 10% - 90% variation of trabecular bone strength on an individual basis (16), leaving sometimes up to 90% of th…”
BackgroundA validated finite element study of stress shielding in a novel hybrid knee implant
Mahboob, Z. (2021) · doi:10.32920/ryerson.14649990 · Cited by 4
Özden, S., Çiçek, O., & Sobi, E. (2025) · BMC Medical Imaging · doi:10.1186/s12880-025-01953-1 · Cited by 3
“Additionally, stiffness and load-bearing capacity of trabecular bone have also been shown to be linearly associated with its mineral density [45].”
Metadata
- Authors
- Ciarelli, M. J., Goldstein, S. A., Kuhn, J. L., Cody, D. D., & Brown, M. B.
- Affiliations
- University of Michigan (US)
- Henry Ford Health (US)
- Corresponding author
- Goldstein, S. A.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1991-09
- Volume
- 9
- Issue
- 5
- Pages
- 674-682
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2048282929
- Cited by
- 401
- References
- 28
- Citations by year
- 2026: 10 · 2025: 6 · 2024: 16 · 2023: 21 · 2022: 7 · 2021: 12 · 2020: 13 · 2019: 9 · 2018: 12 · 2017: 8 · 2016: 8 · 2015: 7 · 2014: 17 · 2013: 14 · 2012: 11
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Orthopaedic Research® (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01ar034399-12)
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR34399)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- trabecular bone, bone mineral density, elastic modulus, uniaxial compression, flexural failure, trabecular bone microarchitecture, cadaveric bone, tibia, femur, radius, humerus, bone strength
- MeSH terms
- Aged, Biomechanical Phenomena, Bone and Bones, Humans, Male, Middle Aged, Tomography, X-Ray Computed, Bone Density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.