Mechanical behavior of human trabecular bone after overloading
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
With the etiology of osteoporotic fractures as motivation, the goal of this study was to characterize the mechanical behavior of human trabecular bone after overloading. Specifically, we quantified the reductions in modulus and strength and the development of residual deformations and determined the dependence of these parameters on the applied strain and apparent density. Forty cylindrical specimens of human L1 vertebral trabecular bone were destructively loaded in compression at 0.5% strain per second to strains of up to 3.0% and then immediately unloaded to zero stress and reloaded. (An ancillary experiment on more readily available bovine bone had been performed previously to develop this testing protocol.) In general, the reloading stress‐strain curve had a short initial nonlinear region with a tangent modulus similar to Young's modulus. This was followed by an approximately linear region spanning to 0.7% strain, with a reduced residual modulus. The reloading curve always approached the extrapolated envelope of the original loading curve. Percent modulus reduction (between Young's and residual), a quantitative measure of mechanical damage, ranged from 5.2 to 91.0% across the specimens. It increased with increasing plastic strain (r 2 = 0.97) but was not related to modulus or apparent density. Percent strength reduction, in the range of 3.6–63.8%, increased with increasing plastic strain (r 2 = 0.61) and decreasing apparent density (r 2 = 0.23). The residual strains of up to 1.05% depended strongly on applied strain (r 2 = 0.96). Statistical comparisons with previous data for bovine tibial bone lend substantial generality to these trends and provide an envelope of expected behavior for other sites. In addition to providing a basis for biomechanical analysis of the effects of damage in trabecular bone at the organ level, these findings support the concept that occasional overloads may increase the risk of fracture by substantially degrading the mechanical properties of the underlying trabecular bone.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“If a specimen is compressed beyond yield (not exceeding 5% strain), unloaded, and reloaded, permanent residual strains and a loss of stiffness (as quantified by a comparison of the slope of the unloading curve to the initial elastic modulus) and strength occur (Figure 1d) (80).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [80]
Citations
Cites
Risk Factors for Hip Fracture in White Women
Cummings, S. R., Nevitt, M. C., Browner, W. S., Stone, K., Fox, K. M., Ensrud, K. E., Cauley, J., Black, D., & Vogt, T. M. (1995) · New England Journal of Medicine · doi:10.1056/nejm199503233321202 · Cited by 3,595
Cooper, C., Atkinson, E. J., MichaelO'Fallon, W., & Dr. Melton, J. L. (1992) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650070214 · Cited by 1,528 · cited 1×
“Although not yet known, this might also apply to the spine because as many as 50% of these fractures are associated with falls (5,30), and destructive loads can also occur with heavy lifting (31).”
BackgroundIn vivo measurement of human tibial strains during vigorous activity
Burr, D. B., Milgrom, C., Fyhrie, D., Forwood, M., Nyska, M., Finestone, A., Hoshaw, S., Saiag, E., & Simkin, A. (1996) · Bone · doi:10.1016/8756-3282(96)00028-2 · Cited by 712 · cited 1×
“2% (2); however, this does not imply that strains cannot be higher in situations when the bone is loaded close to but not beyond the point of overt fracture.”
BackgroundMcCalden, R. W., McGeough, J. A., Barker, M. B., & Court-Brown, C. M. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199308000-00009 · Cited by 709 · cited 1×
“ductile than younger bone (4,27), damages more easily than younger tissue when subjected to the same strain (6).”
BackgroundBone Microdamage and Skeletal Fragility in Osteoporotic and Stress Fractures
Burr, D. B., Forwood, M. R., Fyhrie, D. P., Martin, R. B., Schaffler, M. B., & Turner, C. H. (1997) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1997.12.1.6 · Cited by 686 · cited 2×
“Damage and repair of individual trabeculae is a normal physiologic process (3,15) that increases with age (10,14,28).”
BackgroundYield strain behavior of trabecular bone
Kopperdahl, D. L., & Keaveny, T. M. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00057-8 · Cited by 653 · cited 2×
“method has been validated Tor monotonic loading (21,23).”
BackgroundMethodSelf-citationAging of bone tissue: mechanical properties.
Burstein, A. H., Reilly, D. T., & Martens, M. A. (1976) · PubMed · Cited by 614
Classification of vertebral fractures
Eastell, R., Cedel, S. L., Wahner, H. W., Riggs, B. L., & Dr. Melton, L. J. (1991) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650060302 · Cited by 610
Aging of bone tissue: mechanical properties
Burstein, A., Reilly, D., & Martens, M. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658010-00015 · Cited by 569 · cited 1×
“ductile than younger bone (4,27), damages more easily than younger tissue when subjected to the same strain (6).”
BackgroundPrediction of vertebral body compressive fracture using quantitative computed tomography.
McBroom, R. J., Hayes, W. C., Edwards, W. T., Goldberg, R. P., & White, A. A. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567080-00010 · Cited by 432
Cited by
Items 101–157 of 157
Effects of bone damage on creep behaviours of human vertebral trabeculae
O'Callaghan, P., Szarko, M., Wang, Y., & Luo, J. (2017) · Bone · doi:10.1016/j.bone.2017.10.022 · Cited by 10
“The residual modulus was calculated as the slope of the approximately linear region in the compressive re-loading cycle [28].”
BackgroundMethodEffect of Compressive Straining on Nanoindentation Elastic Modulus of Trabecular Bone
Gan, M., Samvedi, V., Cerrone, A. R., Dubey, D. K., & Tomar, V. (2009) · Experimental Mechanics · doi:10.1007/s11340-009-9274-1 · Cited by 11
“over-loading, may not cause a significant fracture of the bone, but can indeed reduce the modulus, thus the mechanical function of the bone, Keaveny et al. [ 31 ].”
BackgroundVilana, S. G., & Sánchez‐Molina, D. (2023) · Continuum Mechanics and Thermodynamics · doi:10.1007/s00161-023-01257-1 · Cited by 8
“Some of these models use plasticity theory [1–7], continuous damage theory [8–13], rheological theories [14,15] (including nonlinear viscoelastic and viscoplastic models [16–18]), microstructural parameters and microcontinuum models [19–21], statistical models such as the random spring network…”
A nonlinear micromechanical model for progressive damage of vertebral trabecular bones
Massarwa, E., Aboudi, J., Galbusera, F., Wilke, H., & Haj-Ali, R. M. (2017) · Journal of mechanics of materials and structures · doi:10.2140/jomms.2017.12.407 · Cited by 8
Ratcheting-fatigue behavior of trabecular bone under cyclic tensile-compressive loading
Lin, X., Zhao, J., Gao, L., Zhang, C., & Gao, H. X. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.104003 · Cited by 8
McMorran, J. G., & Gregory, D. E. (2021) · Journal of Biomechanical Engineering · doi:10.1115/1.4049749 · Cited by 9
McNamara, I., Rayment, A. W., Brooks, R. A., Best, S. M., & Rushton, N. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.08.027 · Cited by 7
Mesh‐independent damage model for trabecular bone fracture simulation and experimental validation
Do, X. N., Hambli, R., & Ganghoffer, J. (2021) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3468 · Cited by 7
Li, S., Kim, Y.-W., Choi, M.-S., & Nam, T.-H. (2020) · Intermetallics · doi:10.1016/j.intermet.2020.107015 · Cited by 7
Shore, S. W., Unnikrishnan, G. U., Hussein, A. I., & Morgan, E. F. (2012) · CRC Press eBooks · doi:10.1201/b13733-3 · Cited by 8
Trabecular Bone Strain Changes Associated with Subchondral Comminution of the Distal Tibia
McKinley, T. O., Callendar, P. W., & Bay, B. K. (2002) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-200211000-00005 · Cited by 6
“Trabecular bone subjected to consistently elevated strain fatigues and weakens and could collapse during fracture healing, jeopardizing articular reduction (14,15).”
BackgroundLi, S., Wang, X., Kim, Y.-W., Yeom, J., & Nam, T.-H. (2023) · Intermetallics · doi:10.1016/j.intermet.2023.108075 · Cited by 5
Mechanical properties of morcellised bone graft with the addition of hydroxyapatite
McNamara, I., Howard, J., Rayment, A. W., Schalk, R., Brooks, R. A., Best, S. M., & Rushton, N. (2014) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-013-5085-0 · Cited by 5
“Impaction grafting using fresh, frozen morcellised allograft is effective in restoring bone stock, but carries problems of cost, supply and potential infection [1–7].”
BackgroundAn improved metric for quantifying the stiffnesses of intact human vertebrae
Buckley, J. M., Parmeshwar, R., Deviren, V., & Ames, C. P. (2009) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim524 · Cited by 5
Advanced Mechanics of Hard Tissue Using Imaging-Based Measurements and Artificial Intelligence
Tozzi, G., & Buehler, M. J. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-90646-3.00046-0 · Cited by 5
Analyses of trabecular bone failure
Verhulp, E. E. (2006) · TU/e Research Portal · doi:10.6100/ir608109 · Cited by 8
“In particular the softening behavior, typically seen in compression experiments of trabecular bone specimens, was not reproduced (Røhl et al., 1991; Fyhrie and Schaffler, 1994; Keaveny et al., 1999).”
BackgroundResultInfluentialDesign Parameters for Engineering Bone Regeneration
Guldberg, R. E., & Duty, A. O. (2003) · Springer eBooks · doi:10.1007/0-387-21547-6_12 · Cited by 4
“If we use trabecular bone as a design goal, typical ranges for compressive strength and modulus are 1–10 MPa and 50–500 MPa, respectively (Keaveny et al., 1999; Mow and Hayes, 1997).”
MethodLocalized Trabecular Damage Adjacent to Interbody Fusion Devices
WARDEN, K. E., & Davy, D. T. (2010) · Spine · doi:10.1097/brs.0b013e3181ba0003 · Cited by 5
Histerese de fêmures de ratas submetidos a ensaio de flexão, em diferentes faixas etárias.
Shimano, M. M. (2001) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.82.2001.tde-29102001-110800 · Cited by 4
Fractures of the proximal femur: correlates of radiological evidence of osteoporosis
Cristofolini, L. (2007) · Skeletal Radiology · doi:10.1007/s00256-007-0299-1 · Cited by 5
Sadighi, A., Taheri, M., Black, N., Stolle, J. T., Taghvaei, M., Boyes, M. S., Siegler, S., Schaer, T. P., & Najafi, A. R. (2025) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-025-02001-1 · Cited by 3
“Several studies reported that while moderate mechanical stimuli promote bone formation, excessive loading may trigger overload resorption, particularly at implant interfaces (Keaveny et al. 1999; McNamara et al. 2006; Shi et al. 2010; Van Oosterwyck et al. 2002).”
Raccoons Reveal Hidden Diversity in Trabecular Bone Development
Reinecke, T. E., & Angielczyk, K. D. (2024) · Integrative Organismal Biology · doi:10.1093/iob/obae038 · Cited by 3
Biomechanics of Vertebral Fracture
Whyne, C. M., McLachlin, S. D., Burke, M., & Hardisty, M. (2017) · Springer eBooks · doi:10.1007/978-3-319-52634-8_2 · Cited by 3
Prediction of failure in cancellous bone using extended finite element method
Salem, M., Westover, L., Adeeb, S., & Duke, K. (2020) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411920936057 · Cited by 3
MICROSTRUCTURAL STRESSES AND STRAINS ASSOCIATED WITH TRABECULAR BONE MICRODAMAGE
Nagaraja, S. (2006) · UPT. Syiah Kuala University Library (Syiah Kuala University) · Cited by 4
Mechanical Behavior of Cortical Bone
Ng, T. P., & Koloor, S. S. R. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-804634-0.00002-1 · Cited by 2
Biomechanical Performance of Biodegradable Screw Fixation in Mandibular Distraction Osteogenesis
Firriolo, J. M., Xue, Y., Weyerbacher, J., Saldana, G. M., Garfinkel, A., Garcia, T. C., Arzi, B., & Wong, G. B. (2023) · Journal of Craniofacial Surgery · doi:10.1097/scs.0000000000009691 · Cited by 2
Ding, H. D., Zhu, Z.-A., Dai, K., Ye, M., & Wang, C. (2008) · Journal of Shanghai Jiaotong University (Science) · doi:10.1007/s12204-008-0623-5 · Cited by 2
Aharoni, S., Rittel, D., & Shemtov‐Yona, K. (2023) · Mechanics of Materials · doi:10.1016/j.mechmat.2023.104767 · Cited by 2
Li, S., Yang, J., Yuan, S., Wu, P., Nam, T.-H., & Wang, X. (2026) · Materials & Design · doi:10.1016/j.matdes.2026.116615 · Cited by 1
Woo, D. G., Lee, T., Ko, C., Kim, H. S., & Won, Y. (2006) · International Conference on Biomedical and Pharmaceutical Engineering · doi:10.1109/icbpe.2006.348590 · Cited by 1
Bone Mineral Density and Fracture Risk Assessment for Patients Undergoing Total Hip Replacement
Pétursson, Þ. (2014) · Cited by 1
Nasr, S. (2012) · Libraries and Cultural Resources (University of Calgary) · doi:10.11575/prism/25397 · Cited by 2
Time-sequence of biomechanical adaption in trabecular tissue during estrogen deficiency
O’Sullivan, L. (2020) · Arrow@dit (Dublin Institute of Technology) · doi:10.13025/17271 · Cited by 1
Pawlikowski, M. (2013) · Prace Naukowe Politechniki Warszawskiej. Mechanika
Kopp, D. (2014) · J. Willard Marriott Library · doi:10.26053/0h-8dyv-gag0
HISTERESE DE FÊMURES DE RATAS SUBMETIDOS A ENSAIO DE FLEXÃO, EM DIFERENTES FAIXAS ETÁRIAS
Bioengenharia, I. (2001)
Effects of Gamma Irradiation on the Damage Processes in Human Trabecular Bone
Ramsey, D. S. (2010) · OhioLink ETD Center (Ohio Library and Information Network)
Sharabi, M., Wilke, H., & Haj-Ali, R. M. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-812851-0.00005-7
Bosiakov, S., Yurkevich, K. S., Silberschmidt, V. V., & Ershova, A. (2018) · Procedia Structural Integrity · doi:10.1016/j.prostr.2018.12.105
Simulation of the fatigue performance of spinal vertebrae
Coe, R. H. (2018) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York)
Monotonic and cyclic behaviour of trabecular bone under uniaxial and multiaxial loading
Januddi, M. S., & Januddi, M. A. F. M. S. (2015)
Kauffman, T. L., Lindsey, C., & Lewis, R. (2007) · Elsevier eBooks · doi:10.1016/b978-0-443-10233-2.50069-9
Investigation of pelvic bone fracture mechanism and simulated treatment
Salem, M. (2020) · ERA: Education and Research Archive (University of Alberta) · doi:10.7939/r3-whfc-r014
The elastoplastic numerical model and verification by macroindentation experiment of femoral head
Wang, J., Chen, Y., Wang, S., Wang, L., Jia, H., Chen, B., & Huan, Y. (2021) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2021.1902510
Bone as a Material: Lessons From Nature
O’Sullivan, L., & McNamara, L. M. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.12099-5
Oftadeh, R. (2015) · Digital Repository Service (Northeastern University) · doi:10.17760/d20212379
(2002) · Acta Orthopaedica Scandinavica · doi:10.1080/000164702753671669
Farge, E. (2020) · Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature · doi:10.3410/f.737584689.793580795
(2002) · Acta Orthopaedica Scandinavica · doi:10.1080/000164702760300005
Fischer, B., Reise, R., Schleifenbaum, S., & Roth, A. J. (2023) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2023.106057
Changes in the biomechanical properties of the bone during implant placement
Nagy, Á. L. (2023) · SZTE Repository of Dissertations (University of Szeged) · doi:10.14232/phd.11745
Influence de l’hétérogénéité des propriétés mécaniques sur la résistance de l’os trabéculaire humain
Dépalle, B. (2011) · theses.fr (ABES) · doi:10.70675/bf4d472cz0dd4z4d20za7f2zd8806f663dd6 · Cited by 5
“1 Microfissures, élasticité et contrainte maximale La sollicitation de l’os en traction ou en compression quasi-statique, au-delà de la contrainte maximale, conduit à une réduction du module élastique pouvant atteindre 50 % pour l’os cortical et 80 % pour l’os trabéculaire [208].”
Seyrès, P. (2009) · theses.fr (ABES) · doi:10.70675/672eda06z36afz4284zbbcfz736302bcfd9d
Decaup, P.-H. (2025) · theses.fr (ABES) · doi:10.70675/dfb3b403zf2a9z4691z9550z3b2a7fa34564
Metadata
- Authors
- Keaveny, T. M., Wachtel, E. F., & Kopperdahl, D. L.
- Affiliations
- University of California, San Francisco (US)
- University of California, Berkeley (US)
- Corresponding author
- Keaveny, Tony M.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1999-05
- Volume
- 17
- Issue
- 3
- Pages
- 346-353
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2165456908
- Cited by
- 155
- References
- 33
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 3 · 2023: 6 · 2022: 2 · 2021: 9 · 2020: 11 · 2019: 6 · 2018: 10 · 2017: 5 · 2016: 5 · 2015: 3 · 2014: 6 · 2013: 8 · 2012: 7
- FWCI
- 5.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Orthopaedic Research® (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR41481)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- trabecular bone, mechanical overload, osteoporotic fractures, modulus reduction, strength degradation, residual strain, plastic strain, apparent bone density, compressive loading, vertebral bone, mechanical damage, bone biomechanics
- MeSH terms
- Adult, Aged, Aged, 80 and over, Animals, Biomechanical Phenomena, Elasticity, Female, Humans, Lumbar Vertebrae, Male, Middle Aged, Pressure, Stress, Mechanical
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.