Mechanical behavior of human trabecular bone after overloading
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
With the etiology of osteoporotic fractures as motivation, the goal of this study was to characterize the mechanical behavior of human trabecular bone after overloading. Specifically, we quantified the reductions in modulus and strength and the development of residual deformations and determined the dependence of these parameters on the applied strain and apparent density. Forty cylindrical specimens of human L1 vertebral trabecular bone were destructively loaded in compression at 0.5% strain per second to strains of up to 3.0% and then immediately unloaded to zero stress and reloaded. (An ancillary experiment on more readily available bovine bone had been performed previously to develop this testing protocol.) In general, the reloading stress‐strain curve had a short initial nonlinear region with a tangent modulus similar to Young's modulus. This was followed by an approximately linear region spanning to 0.7% strain, with a reduced residual modulus. The reloading curve always approached the extrapolated envelope of the original loading curve. Percent modulus reduction (between Young's and residual), a quantitative measure of mechanical damage, ranged from 5.2 to 91.0% across the specimens. It increased with increasing plastic strain (r 2 = 0.97) but was not related to modulus or apparent density. Percent strength reduction, in the range of 3.6–63.8%, increased with increasing plastic strain (r 2 = 0.61) and decreasing apparent density (r 2 = 0.23). The residual strains of up to 1.05% depended strongly on applied strain (r 2 = 0.96). Statistical comparisons with previous data for bovine tibial bone lend substantial generality to these trends and provide an envelope of expected behavior for other sites. In addition to providing a basis for biomechanical analysis of the effects of damage in trabecular bone at the organ level, these findings support the concept that occasional overloads may increase the risk of fracture by substantially degrading the mechanical properties of the underlying trabecular bone.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“If a specimen is compressed beyond yield (not exceeding 5% strain), unloaded, and reloaded, permanent residual strains and a loss of stiffness (as quantified by a comparison of the slope of the unloading curve to the initial elastic modulus) and strength occur (Figure 1d) (80).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [80]
Citations
Cites
Risk Factors for Hip Fracture in White Women
Cummings, S. R., Nevitt, M. C., Browner, W. S., Stone, K., Fox, K. M., Ensrud, K. E., Cauley, J., Black, D., & Vogt, T. M. (1995) · New England Journal of Medicine · doi:10.1056/nejm199503233321202 · Cited by 3,595
Cooper, C., Atkinson, E. J., MichaelO'Fallon, W., & Dr. Melton, J. L. (1992) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650070214 · Cited by 1,528 · cited 1×
“Although not yet known, this might also apply to the spine because as many as 50% of these fractures are associated with falls (5,30), and destructive loads can also occur with heavy lifting (31).”
BackgroundIn vivo measurement of human tibial strains during vigorous activity
Burr, D. B., Milgrom, C., Fyhrie, D., Forwood, M., Nyska, M., Finestone, A., Hoshaw, S., Saiag, E., & Simkin, A. (1996) · Bone · doi:10.1016/8756-3282(96)00028-2 · Cited by 712 · cited 1×
“2% (2); however, this does not imply that strains cannot be higher in situations when the bone is loaded close to but not beyond the point of overt fracture.”
BackgroundMcCalden, R. W., McGeough, J. A., Barker, M. B., & Court-Brown, C. M. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199308000-00009 · Cited by 709 · cited 1×
“ductile than younger bone (4,27), damages more easily than younger tissue when subjected to the same strain (6).”
BackgroundBone Microdamage and Skeletal Fragility in Osteoporotic and Stress Fractures
Burr, D. B., Forwood, M. R., Fyhrie, D. P., Martin, R. B., Schaffler, M. B., & Turner, C. H. (1997) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1997.12.1.6 · Cited by 686 · cited 2×
“Damage and repair of individual trabeculae is a normal physiologic process (3,15) that increases with age (10,14,28).”
BackgroundYield strain behavior of trabecular bone
Kopperdahl, D. L., & Keaveny, T. M. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00057-8 · Cited by 653 · cited 2×
“method has been validated Tor monotonic loading (21,23).”
BackgroundMethodSelf-citationAging of bone tissue: mechanical properties.
Burstein, A. H., Reilly, D. T., & Martens, M. A. (1976) · PubMed · Cited by 614
Classification of vertebral fractures
Eastell, R., Cedel, S. L., Wahner, H. W., Riggs, B. L., & Dr. Melton, L. J. (1991) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650060302 · Cited by 610
Aging of bone tissue: mechanical properties
Burstein, A., Reilly, D., & Martens, M. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658010-00015 · Cited by 569 · cited 1×
“ductile than younger bone (4,27), damages more easily than younger tissue when subjected to the same strain (6).”
BackgroundPrediction of vertebral body compressive fracture using quantitative computed tomography.
McBroom, R. J., Hayes, W. C., Edwards, W. T., Goldberg, R. P., & White, A. A. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567080-00010 · Cited by 432
Fall Frequency and Characteristics and the Risk of Hip Fractures
Cumming, R. G., & Klineberg, R. J. (1994) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1994.tb06540.x · Cited by 415
Systematic and random errors in compression testing of trabecular bone
Keaveny, T. M., Pinilla, T. P., Crawford, R. P., Kopperdahl, D. L., & Lou, A. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150115 · Cited by 377 · cited 3×
“method has been validated Tor monotonic loading (21,23).”
BackgroundMethodSelf-citationKeaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90054-x · Cited by 330
Self-citationFracture Prediction for the Proximal Femur Using Finite Element Models: Part I—Linear Analysis
Lotz, J. C., Cheal, E. J., & Hayes, W. C. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2895412 · Cited by 309
Trabecular bone exhibits fully linear elastic behavior and yields at low strains
Keaveny, T. M., Guo, X. E., Wachtel, E. F., McMahon, T. A., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90053-1 · Cited by 300 · cited 1×
“Twenty-eight longitudinally oriented, reduced-section cylindrical specimens were harvested from 28 1 -2-year-old steers according to our published protocols (18).”
MethodSelf-citationContinuum Damage Mechanics Theory and Application
(1987) · Springer eBooks · doi:10.1007/978-3-7091-2806-0 · Cited by 293
Biomechanics of Osteoporosis and Vertebral Fracture
Myers, E. R., & Wilson, S. E. (1997) · Spine · doi:10.1097/00007632-199712151-00005 · Cited by 239
The underestimation of Young's modulus in compressive testing of cancellous bone specimens
Odgaard, A., & Linde, F. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90333-i · Cited by 225
Mori, S., Harruff, R., Ambrosius, W., & Burr, D. B. (1997) · Bone · doi:10.1016/s8756-3282(97)00200-7 · Cited by 224
Failure mechanisms in human vertebral cancellous bone
Fyhrie, D. P., & Schaffler, M. B. (1994) · Bone · doi:10.1016/8756-3282(94)90900-8 · Cited by 215
Fazzalari, N. L., Forwood, M. R., Smith, K., Manthey, B. A., & Herreen, P. (1998) · Bone · doi:10.1016/s8756-3282(97)00298-6 · Cited by 168
The effect of impact direction on the structural capacity of the proximal femur during falls
Ford, C. M., Keaveny, T. M., & Hayes, W. C. (1996) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650110311 · Cited by 157
Self-citationCreep Contributes to the Fatigue Behavior of Bovine Trabecular Bone
Bowman, S. M., Guo, X. E., Cheng, D. W., Keaveny, T. M., Gibson, L. J., Hayes, W. C., & McMahon, T. A. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2834757 · Cited by 149 · cited 1×
“The development of these small permanent deformations after overloads, consistent with values reported elsewhere for human vertebral bone (13), suggcsts the possibility that progressive fractures such as spinal wedge fractures may develop slowly over time as a result of a previous history of isolated bending overloads…”
ResultSelf-citationSome viscoplastic characteristics of bovine and human cortical bone
Fondrk, M. T., Bahniuk, E., Davy, D. T., & Michaels, C. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90200-x · Cited by 146
Theoretical analysis of the experimental artifact in trabecular bone compressive modulus
Keaveny, T. M., Borchers, R. E., Gibson, L. J., & Hayes, W. C. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90021-6 · Cited by 136
Self-citationAge-related differences in post-yield damage in human cortical bone. Experiment and model
Courtney, A. C., Hayes, W. C., & Gibson, L. J. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(96)84542-8 · Cited by 131 · cited 1×
“ductile than younger bone (4,27), damages more easily than younger tissue when subjected to the same strain (6).”
BackgroundMechanical behavior of damaged trabecular bone
Keaveny, T. M., Wachtel, E. F., Guo, X.-D. E., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90040-x · Cited by 113
Self-citationPineda, L. M., B�sing, M., Meinig, R. P., & Gogolewski, S. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199607)31:3<421::aid-jbm17>3.0.co;2-l · Cited by 106
Dependence of trabecular damage on mechanical strain
Wachtel, E. F., & Keaveny, T. M. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150522 · Cited by 95
Self-citationMyers, B. S., Arbogast, K. B., Lobaugh, B., Harper, K. D., Richardson, W. J., & Drezner, M. K. (1994) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650090514 · Cited by 91
Microcalluses of the Trabeculae in Lumbar Vertebrae and Their Relation to the Bone Mineral Content
HANSSON, T. H., & ROOS, B. (1981) · Spine · doi:10.1097/00007632-198107000-00008 · Cited by 58
Microcallus formations of the cancellous bone: A quantitative analysis of the human spine
Hahn, M. P., Vogel, M., Amling, M., Ritzel, H., & Delling, G. (1995) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650100919 · Cited by 50
Hasegawa, K., Turner, C. H., Chen, J., & Burr, D. B. (1995) · PubMed · Cited by 33
Cited by
Bone Mechanical Properties in Healthy and Diseased States
Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121139 · Cited by 1,026
“If a specimen is compressed beyond yield (not exceeding 5% strain), unloaded, and reloaded, permanent residual strains and a loss of stiffness (as quantified by a comparison of the slope of the unloading curve to the initial elastic modulus) and strength occur (Figure 1d) (80).”
Biomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 801
“fashion with increasing total applied strain (89).”
InfluentialSelf-citationBiomechanics and Mechanobiology of Trabecular Bone: A Review
Oftadeh, R., Perez-Viloria, M., Villa-Camacho, J. C., Vaziri, A., & Nazarian, A. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4029176 · Cited by 547
Effects of Bone Cement Volume and Distribution on Vertebral Stiffness After Vertebroplasty
Liebschner, M. A. K., Rosenberg, W. S., & Keaveny, T. M. (2001) · Spine · doi:10.1097/00007632-200107150-00009 · Cited by 470
“The elastic properties of the damaged trabecular bone elements were then reduced according to empirical relations developed for human vertebral trabecular bone (Figure 2) with a maximum percent reduction of 85%.(17) Trabecular bone elastic properties of elements strained below the yield point were reduced also using t…”
MethodResultSelf-citationZhou, T., Gao, B., Fan, Y., Liu, Y., Feng, S., Cong, Q., Zhang, X., Zhou, Y., Yadav, P. S., Lin, J., et al. (2020) · eLife · doi:10.7554/elife.52779 · Cited by 392
“However, abnormal loading leads to cartilage damage and osteoarthritis as well as pathological bone alterations that may result in fracture when accumulated (Astur et al., 2016; Keaveny et al., 1999).”
Background
Metadata
- Authors
- Keaveny, T. M., Wachtel, E. F., & Kopperdahl, D. L.
- Affiliations
- University of California, San Francisco (US)
- University of California, Berkeley (US)
- Corresponding author
- Keaveny, Tony M.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1999-05
- Volume
- 17
- Issue
- 3
- Pages
- 346-353
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2165456908
- Cited by
- 155
- References
- 33
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 3 · 2023: 6 · 2022: 2 · 2021: 9 · 2020: 11 · 2019: 6 · 2018: 10 · 2017: 5 · 2016: 5 · 2015: 3 · 2014: 6 · 2013: 8 · 2012: 7
- FWCI
- 5.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Orthopaedic Research® (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR41481)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- trabecular bone, mechanical overload, osteoporotic fractures, modulus reduction, strength degradation, residual strain, plastic strain, apparent bone density, compressive loading, vertebral bone, mechanical damage, bone biomechanics
- MeSH terms
- Adult, Aged, Aged, 80 and over, Animals, Biomechanical Phenomena, Elasticity, Female, Humans, Lumbar Vertebrae, Male, Middle Aged, Pressure, Stress, Mechanical
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.