The DOI matches its Crossref record; 86 of the 86 references it cites were found in a registry or an index.
An overview of matrix effects in liquid chromatography–mass spectrometry
Abstract
Matrix‐dependent signal suppression or enhancement represents a major drawback in quantitative analysis with liquid chromatography coupled to atmospheric pressure ionization mass spectrometry (LC–API‐MS). Because matrix effects (ME) might exert a detrimental impact on important method parameters (limit of detection, limit of quantification, linearity, accuracy, and precision), they have to be tested and evaluated during validation procedure. This review gives a detailed description on when these phenomena might be expected, and how they can be evaluated. The major sources of ME are discussed and illustrated with examples from bioanalytical, pharmaceutical, environmental, and food analysis. Because there is no universal solution for ME, the main strategies to overcome these phenomena are described in detail. Special emphasis is devoted to the sample‐preparation procedures as well as to the recent improvements on chromatographic and mass spectrometric conditions. An overview of the main calibration techniques to compensate for ME is also presented. All these solutions can be used alone or in combination to retrieve the performance of the LC–MS for a particular matrix–analyte combination. © 2010 Wiley Periodicals, Inc., Mass Spec Rev 30:491–509, 2011
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matuszewski, B. K., Constanzer, M. L., & Chavez-Eng, C. M. (2003) · Analytical Chemistry · doi:10.1021/ac020361s · Cited by 5,335
Analytical Properties of the Nanoelectrospray Ion Source
Wilm, M., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac9509519 · Cited by 1,868
Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
Ion Suppression in Mass Spectrometry
Annesley, T. M. (2003) · Clinical Chemistry · doi:10.1373/49.7.1041 · Cited by 1,591
Practical implications of some recent studies in electrospray ionization fundamentals
Cech, N. B., & Enke, C. G. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10008 · Cited by 1,435
On the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
Taylor, P. J. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.11.007 · Cited by 1,248
Mechanistic investigation of ionization suppression in electrospray ionization
King, R., Bonfiglio, R., Fernandez-Metzler, C., Miller-Stein, C., & Olah, T. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00163-x · Cited by 1,086
Bonfiglio, R., King, R. C., Olah, T. V., & Merkle, K. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990630)13:12<1175::aid-rcm639>3.0.co;2-0 · Cited by 939
Matuszewski, B. K., Constanzer, M. L., & Chavez-Eng, C. M. (1998) · Analytical Chemistry · doi:10.1021/ac971078+ · Cited by 880
Cited by
Sullivan, M. R., Danai, L. V., Lewis, C. A., Chan, S. H., Gui, D. Y., Kunchok, T., Dennstedt, E. A., Vander Heiden, M. G., & Muir, A. (2019) · eLife · doi:10.7554/elife.44235 · Cited by 588
“As both 12C and 13C metabolites are subject to the same sample-dependent ion enhancement or suppression effects, this method limits error from matrix effects in metabolite quantification (Trufelli et al., 2011).”
BackgroundMethodMatrix Effects and Application of Matrix Effect Factor
Zhou, W., Yang, S., & Wang, P. G. (2017) · Bioanalysis · doi:10.4155/bio-2017-0214 · Cited by 430
Mass spectrometry‐based plant metabolomics: Metabolite responses to abiotic stress
Jorge, T. F., Rodrigues, J. A., Caldana, C., Schmidt, R., van Dongen, J. T., Thomas‐Oates, J., & António, C. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21449 · Cited by 376
Granados-Chinchilla, F., & Rodríguez, C. (2017) · Journal of Analytical Methods in Chemistry · doi:10.1155/2017/1315497 · Cited by 372
Stahnke, H., Kittlaus, S., Kempe, G., & Alder, L. (2012) · Analytical Chemistry · doi:10.1021/ac202661j · Cited by 341
Tutorial review on validation of liquid chromatography–mass spectrometry methods: Part II
Kruve, A., Rebane, R., Kipper, K., Oldekop, M.-L., Evard, H., Herodes, K., Ravio, P., & Leito, I. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.02.016 · Cited by 338
Tutorial review on validation of liquid chromatography–mass spectrometry methods: Part I
Kruve, A., Rebane, R., Kipper, K., Oldekop, M.-L., Evard, H., Herodes, K., Ravio, P., & Leito, I. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.02.017 · Cited by 300
Cortese, M., Gigliobianco, M. R., Magnoni, F., Censi, R., & Di Martino, P. (2020) · Molecules · doi:10.3390/molecules25133047 · Cited by 280
A review of the pharmaceutical exposome in aquatic fauna
Miller, T. H., Bury, N. R., Owen, S. F., MacRae, J. I., & Barron, L. P. (2018) · Environmental Pollution · doi:10.1016/j.envpol.2018.04.012 · Cited by 262
The use of mass spectrometry to analyze dried blood spots
Wagner, M., Tonoli, D., Varesio, E., & Hopfgartner, G. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21441 · Cited by 262
Sulyok, M., Stadler, D., Steiner, D., & Krska, R. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02489-9 · Cited by 253
González, O., Blanco, M. E., Iriarte, G., Bartolomé, L., Maguregui, M. I., & Alonso, R. M. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.03.077 · Cited by 253
Barri, T., Holmer-Jensen, J., Hermansen, K., & Dragsted, L. O. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.12.065 · Cited by 57
Ciofi, L., Renai, L., Rossini, D., Ancillotti, C., Falai, A., Fibbi, D., Bruzzoniti, M. C., Santana-Rodriguez, J. J., Orlandini, S., & Del Bubba, M. (2018) · Talanta · doi:10.1016/j.talanta.2017.08.052 · Cited by 47
Case for the wider adoption of mass spectrometry-based adrenal steroid testing, and beyond
Monaghan, P. J., Keevil, B. G., Stewart, P. M., & Trainer, P. J. (2014) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2014-2258 · Cited by 41
Metadata
- Authors
- Trufelli, H., Palma, P., Famiglini, G., & Cappiello, A.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2010-10-22
- Volume
- 30
- Issue
- 3
- Pages
- 491-509
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W1991430603
- Cited by
- 811
- References
- 86
- FWCI
- 14.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.