Case for the wider adoption of mass spectrometry-based adrenal steroid testing, and beyond

Monaghan, Phillip J., Keevil, Brian G., Stewart, Paul M., Trainer, Peter J.·2014·The Journal of Clinical Endocrinology & Metabolism

Abstract

The move by the JCEM to mandate measurement of sex steroids by mass spectrometry (MS) in manuscripts to be published from the beginning of 2015 (1) sparked vigorous debate among clinicians and scientists working within the diverse subspecialties of endocrinology. In response, The Endocrine Society Council assembled a Sex Steroid Assays Reporting Task Force (SSARTF) to review current reporting polices laid out by the Journal (and sister journals) and to recommend through the Publications Core Committee a clear policy on the future reporting of sex steroid hormone measurements. We commend the SSARTF in broadening the scope of their new guideline not only to encompass sex steroid hormone measurement but also to address the measurement of all steroid hormones more generally. Such an inclusive policy will undoubtedly propel the field toward optimized measurement procedures. With this goal in mind, we wish to make the case that the limitations inherent in immunoassay (IA) and the opportunities afforded by MS are not confined to the measurement of sex steroids, but rather the argument for measurement of cortisol and related metabolites is equally as compelling. Here, we present the case for cortisol measurement as an exemplar for the wider adoption of MS. IAs for serum steroid measurement are afflicted with cross-reactivity, to varying and often clinically significant degrees, with both endogenous and exogenous steroid hormones and their metabolites (2). Examples of analytical interference in commercial IAs include cross-reactivity in T assay by the structurally similar oral contraceptive pill component norethisterone (3) and the impact of both sample matrix and gender on the measurement of cortisol, likely attributable to variations in both cortisol-binding globulin concentration, and the accumulation of structurally related steroids in various physiological and pathophysiological conditions (4) acts to illustrate the inherent and persistent obstacles encountered by IA-based methodologies regardless of measurand, be it androgen or glucocorticoid. Similarly, indirect interference in many cortisol IAs has been demonstrated in patients receiving the 11β-hydroxylase inhibitor metyrapone for the medical management of Cushing's syndrome (5, 6). Metyrapone therapy blocks the conversion of 11-deoxycortisol to cortisol, causing a >10-fold increase in circulating concentration of this precursor (7, 8), which cross-reacts significantly in cortisol IA. The consequent positive interference carries the very real risk of inappropriate dose escalation and unrecognized hypoadrenalism. Salivary cortisol measurement used routinely in the investigation of Cushing's syndrome, and as a measure of “stress” in psychological research, is often measured by IA. However, there is a failure to recognize that, because of the abundance in parotid tissue of the enzyme 11β-hydroxysteroid dehydrogenase type II, which converts cortisol to cortisone, the latter is the predominate glucocorticoid in saliva at levels between 4- and 9-fold greater than cortisol. Cortisone cross-reactivity may therefore confound the accurate measurement of salivary cortisol in many IAs. Some of these problems inherent in IAs may be resolved by extracting samples to remove cross-reacting compounds and alleviate matrix effects before measurement, but importantly, such preanalytical extraction adds additional costs and complexity. In recent decades, the great advantage with IA has been speed and simplicity; sample prepurification seriously derogates from this and would therefore need to be evaluated in view of potential gains in diagnostic efficiency (9). These common and clinically important interferences in IA can be surmounted by the use of MS, and at present there are no feasible methodological alternatives that provide equivalent analytical robustness for steroid assay. As well as eliminating cross-reactivity, a further crucial practical advantage of MS is the dynamic range of measurement that can be achieved, comfortably exceeding that possible by conventional competitive IA methodology for the quantification of small molecules such as steroid hormones. For competitive IA, the typical dynamic range of the sigmoidal dose-response curve is no more than two orders of magnitude in measurand concentration. Assay manufacturers must therefore consider the clinical requirement for analytical sensitivity and also the expected (patho)physiological concentrations of measurand when designing these assays. Further methodological advantages of MS include the lack of susceptibility to interference from antireagent antibodies and the capacity to multiplex measurements for steroid profiling. In other words, a female androgen profile consisting of T, androstenedione, and dehydroepiandrosterone sulfate may be simultaneously measured in a single assay at negligible extra cost compared to measuring any of the steroids individually. From a practical standpoint, rapid MS assays for the rou

Integrity signals

Registry

Crossref · 10.1210/jc.2014-2258

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Monaghan, P. J., Keevil, B. G., Stewart, P. M., & Trainer, P. J.
Affiliations
  • The Christie Pathology Partnership (P.J.M.), Manchester, M20 4BX, UK
  • Department of Clinical Biochemistry (B.G.K.), University Hospital of South Manchester, Manchester M23 9LT, United Kingdom
  • University of Leeds (GB)
  • Manchester Academic Health Science Centre (GB)
Corresponding author
Trainer, Peter J.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2014-12-01
Volume
99
Issue
12
Pages
4434-4437
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2047246870
Cited by
41
References
15
Citations by year
2026: 1 · 2025: 2 · 2024: 2 · 2023: 6 · 2022: 5 · 2021: 2 · 2020: 1 · 2019: 5 · 2018: 2 · 2017: 4 · 2016: 5 · 2015: 6
FWCI
4.02
Type
journal article
Language
en
Open access
closed
Locations
  • The Journal of Clinical Endocrinology & Metabolism (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Adrenal Hormones and Disorders
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
Keywords
mass spectrometry, cortisol measurement, immunoassay limitations, cross-reactivity, analytical interference, 11-deoxycortisol, metyrapone, Cushing's syndrome, adrenal insufficiency, salivary cortisol, corticosteroid-binding globulin, reporting guidelines, 11β-hydroxylase
MeSH terms
Adrenal Cortex Hormones, Adrenal Gland Diseases, Female, Humans, Immunoassay, Male, Gonadal Steroid Hormones, Mass Spectrometry, Reproducibility of Results

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review