Recording and stimulating properties of chronically implanted longitudinal intrafascicular electrodes in peripheral fascicles in an animal model
Abstract
The purpose of this experiment was to study the recording and stimulating properties, and biocompatibility of longitudinally implanted intrafascicular electrodes (LIFEs) in a rabbit sciatic nerve model when they were chronically implanted into peripheral fascicles. LIFEs were implanted chronically into sciatic nerve fascicles of rabbits as recording and stimulating electrodes. Motor‐evoked potentials (MEPs) and cortical somatosensory‐evoked potentials (CSEPs) were recorded by using a transcranial stimulation system (TCS) over 6‐month period to observe the change of the signals recorded. At the end of the experiment, the fascicles at the electrodes implanted site were anatomized for histological examination under light microscope and transmission electron microscope. Results showed onset latency (OL) of MEPs and CSEPs had no obvious change during the first month. However, OL significantly increased during the second month, and then became stable 3 months after implantation. The interpeak amplitudes (IPAs) of MEPs had no distinct change during the first month, but significantly decreased over the next period, and then became stable 3 months after implantation. The IPAs of CSEPs, however, decreased slowly over the 6‐month period of the study. At the end of the experiment, histological examination indicated that a typical foreign body reaction developed, and electrodes caused mild damage to the fascicles, though inflammatory cells and neuroma were not seen around the electrodes. In conclusion, LIFEs have excellent recording and stimulating characters in addition to biocompatibility with peripheral fascicles. They can be implanted chronically into fascicles and record signals. © 2008 Wiley‐Liss, Inc. Microsurgery, 2008.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A 6-month rat study showed electrode breakage in a small percent of the electrodes leading to failure.
“A 6-month rat study showed electrode breakage in a small percent of the electrodes leading to failure [95].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [95]
Cites
Prosthetic usage in major upper extremity amputations
Wright, T. W., Hagen, A. D., & Wood, M. B. (1995) · The Journal Of Hand Surgery · doi:10.1016/s0363-5023(05)80278-3 · Cited by 268 · see citing works
Lago, N., Yoshida, K., Koch, K. P., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886617 · Cited by 227 · see citing works
Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
Yoshida, K., & Horch, K. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.243412 · Cited by 208 · see citing works
Chronically implanted intrafascicular recording electrodes
Lefurge, T., Goodall, E., Horch, K., Stensaas, L., & Schoenberg, A. (1991) · Annals of Biomedical Engineering · doi:10.1007/bf02368469 · Cited by 172 · see citing works
Yoshida, K., & Horch, K. W. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.481986 · Cited by 132 · see citing works
An intrafascicular electrode for recording of action potentials in peripheral nerves
Malagodi, M. S., Horch, K. W., & Schoenberg, A. A. (1989) · Annals of Biomedical Engineering · doi:10.1007/bf02368058 · Cited by 107 · see citing works
Hand Prosthesis Control Via Myoelectric Patterns
Herberts, P., Almström, C., Kadefors, R., & Lawrence, P. D. (1973) · Acta Orthopaedica Scandinavica · doi:10.3109/17453677308989075 · Cited by 97 · see citing works
Metallized polymer fibers as leadwires and intrafascicular microelectrodes
McNaughton, T. G., & Horch, K. W. (1996) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(96)00111-2 · Cited by 76 · see citing works
Information contained in sensory nerve recordings made with intrafascicular electrodes
Goodall, E. V., Lefurge, T. M., & Horch, K. W. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83604 · Cited by 63 · see citing works
Electrically powered prostheses for the adult with an upper limb amputation
Heger, H., Millstein, S. G., & Hunter, G. (1985) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.67b2.3980541 · Cited by 61 · see citing works
Long‐term biocompatibility of implanted polymer‐based intrafascicular electrodes
Lawrence, S. M., Larsen, J. O., Horch, K. W., Riso, R., & Sinkjær, T. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10303 · Cited by 55 · see citing works
Malmstrom, J. A., McNaughton, T. G., & Horch, K. W. (1998) · Annals of Biomedical Engineering · doi:10.1114/1.35 · Cited by 50 · cited 2× · see citing works
“Malmstrom et al.18 implanted polymer-based longitudinal intrafascicular electrodes (polyLIFEs).”
BackgroundClinical application study of multifunctional prosthetic hands
Herberts, P., Almström, C., & Caine, K. (1978) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.60b4.711808 · Cited by 43 · see citing works
Traumatic amputation of the upper limb
Stürup, J., Thyregod, H. C., Jensen, J. S., Retpen, J. B., Boberg, G., Rasmussen, E. J., & Jensen, S. (1988) · Prosthetics and Orthotics International · doi:10.3109/03093648809079390 · Cited by 42 · see citing works
Influence of Nitrous Oxide on Motor-Evoked Potentials
Zentner, J., Thees, C., Pechstein, U., Scheufler, K.-M., Würker, J., & Nadstawek, J. (1997) · Spine · doi:10.1097/00007632-199705010-00012 · Cited by 36 · see citing works
Zheng, X., Zhang, J., Chen, T., & Chen, Z. (2003) · Microsurgery · doi:10.1002/micr.10116 · Cited by 22 · see citing works
Self-citationProtocol for microneurography with concentric needle electrodes
Hallin, R. G., & Wu, G. (1998) · Brain Research Protocols · doi:10.1016/s1385-299x(97)00025-1 · Cited by 16 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
The foreign body response to the Utah Slant Electrode Array in the cat sciatic nerve
Christensen, M. B., Pearce, S. M., Ledbetter, N. M., Warren, D. J., Clark, G. A., & Tresco, P. A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.010 · Cited by 135 · see citing works
Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review
Yildiz, K. A., Shin, A. Y., & Kaufman, K. R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00667-5 · Cited by 113 · see citing works
“A 6-month rat study showed electrode breakage in a small percent of the electrodes leading to failure [95].”
BackgroundSelectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review.
Ghafoor, U., Kim, S., & Hong, K.-S. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00059 · Cited by 88 · see citing works
“…2016), stretchable polymeric multi-electrode array (Guo et al., 2014), TIME-2 and TIME-3 with different chemical properties (Badia et al., 2011b), LIFE (Zheng et al., 2008), polyimide, platinum intra-fascicular electrodes (Lago et al., 2007b), and polymer-based longitudinal intra-fascicular…”
FitzGerald, J. J., Lago, N., Benmerah, S., Serra, J., Watling, C. P., Cameron, R. E., Tarte, E., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/016010 · Cited by 73 · see citing works
Motor-commands decoding using peripheral nerve signals: a review
Hong, K.-S., Aziz, N., & Ghafoor, U. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab383 · Cited by 63 · see citing works
Conductive Hydrogel Electrodes for Delivery of Long-Term High Frequency Pulses
Staples, N. A., Goding, J. A., Gilmour, A. D., Aristovich, K. Y., Byrnes-Preston, P., Holder, D. S., Morley, J. W., Lovell, N. H., Chew, D. J., & Green, R. A. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00748 · Cited by 45 · see citing works
Bionic Intrafascicular Interfaces for Recording and Stimulating Peripheral Nerve Fibers
Jung, R., Abbas, J. J., Kuntaegowdanahalli, S. S., & Thota, A. K. (2017) · Bioelectronics in Medicine · doi:10.2217/bem-2017-0009 · Cited by 28 · see citing works
Sando, I. C., Adidharma, W., Nedic, A., Ursu, D. C., Mays, E. A., Hu, Y., Kubiak, C. A., Sugg, K. B., Kung, T. A., Cederna, P. S., et al. (2022) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000010086 · Cited by 26 · see citing works
Ordelman, S. C. M. A., Kornet, L., Cornelussen, R. N., Buschman, H. P. J., & Veltink, P. H. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2214058 · Cited by 20 · see citing works
Yu, X. P., Su, J., Guo, J. Y., Zhang, X., Li, R. H., Chai, X., Chen, Y., Zhang, D. G., Wang, J., Sui, X., et al. (2019) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108450 · Cited by 16 · see citing works
Dowden, B. R., Frankel, M. A., Normann, R. A., & Clark, G. A. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/016006 · Cited by 11 · see citing works
Adaptation and Optimization of an Intraneural Electrode to Interface with the Cervical Vagus Nerve
Strauss, I., Zinno, C., Giannotti, A., Ottaviani, M. M., Recchia, F. A., & Micera, S. (2021) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner49283.2021.9441131 · Cited by 4 · see citing works
Sensing and stimulation of the vagus nerve for artificial cardiac control
Ordelman, S. C. M. A. (2011) · doi:10.3990/1.9789036533096 · Cited by 2 · see citing works
Regnacq, L., Thota, A. K., Sanabria, A. O., McPherson, L. M., Renaud, S., Romain, O., Bornat, Y., Abbas, J. J., Jung, R., & Kölbl, F. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adc62a · Cited by 1 · see citing works
- Authors
- Zheng, X., Zhang, J., Chen, T., & Chen, Z.
- Affiliations
- Qingdao University (CN)
- Fudan University (CN)
- Corresponding author
- Zheng, Xiujun
- ORCID
- Zhang, Jian
- Venue
- Microsurgery
- Publisher
- Wiley
- Published
- 2008-01
- Volume
- 28
- Issue
- 3
- Pages
- 203-209
- ISSN
- 0738-1085 (ISSN-L)
- 1098-2752
- OpenAlex
- W1990084364
- Cited by
- 14
- References
- 17
- Citations by year
- 2025: 1 · 2022: 1 · 2021: 1 · 2020: 1 · 2019: 1 · 2018: 2 · 2017: 2 · 2014: 1 · 2012: 2
- FWCI
- 0.29
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Microsurgery (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Surgery › Intraoperative Neuromonitoring and Anesthetic Effects
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Keywords
- peripheral nerve recording, peripheral nerve stimulation, sciatic nerve, chronic implantation, motor evoked potentials, somatosensory evoked potentials, onset latency, biocompatibility, foreign body reaction, neuroma, rabbit model
- MeSH terms
- Animals, Electric Stimulation, Electrodes, Implanted, Evoked Potentials, Somatosensory, Foreign-Body Reaction, Materials Testing, Microsurgery, Neural Conduction, Rabbits, Sciatic Nerve, Time Factors, Evoked Potentials, Motor, Models, Animal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review