CoChat

Abnormal lung quantification in chest CT images of COVID‐19 patients with deep learning and its application to severity prediction

Open access
Shan, Fei, Gao, Yaozong, Wang, Jun, Shi, Weiya, Shi, Nannan, Han, Miaofei, Xue, Zhong, Shen, Dinggang, Shi, Yuxin · 2021 · Medical Physics
Cited by 205

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

Objective: Computed tomography (CT) provides rich diagnosis and severity information of COVID‐19 in clinical practice. However, there is no computerized tool to automatically delineate COVID‐19 infection regions in chest CT scans for quantitative assessment in advanced applications such as severity prediction. The aim of this study was to develop a deep learning (DL)‐based method for automatic segmentation and quantification of infection regions as well as the entire lungs from chest CT scans. Methods: The DL‐based segmentation method employs the “VB‐Net” neural network to segment COVID‐19 infection regions in CT scans. The developed DL‐based segmentation system is trained by CT scans from 249 COVID‐19 patients, and further validated by CT scans from other 300 COVID‐19 patients. To accelerate the manual delineation of CT scans for training, a human‐involved‐model‐iterations (HIMI) strategy is also adopted to assist radiologists to refine automatic annotation of each training case. To evaluate the performance of the DL‐based segmentation system, three metrics, that is, Dice similarity coefficient, the differences of volume, and percentage of infection (POI), are calculated between automatic and manual segmentations on the validation set. Then, a clinical study on severity prediction is reported based on the quantitative infection assessment. Results: The proposed DL‐based segmentation system yielded Dice similarity coefficients of 91.6% ± 10.0% between automatic and manual segmentations, and a mean POI estimation error of 0.3% for the whole lung on the validation dataset. Moreover, compared with the cases with fully manual delineation that often takes hours, the proposed HIMI training strategy can dramatically reduce the delineation time to 4 min after three iterations of model updating. Besides, the best accuracy of severity prediction was 73.4% ± 1.3% when the mass of infection (MOI) of multiple lung lobes and bronchopulmonary segments were used as features for severity prediction, indicating the potential clinical application of our quantification technique on severity prediction. Conclusions: A DL‐based segmentation system has been developed to automatically segment and quantify infection regions in CT scans of COVID‐19 patients. Quantitative evaluation indicated high accuracy in automatic infection delineation and severity prediction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mp.14609

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 205

Metadata

Authors
Shan, F., Gao, Y., Wang, J., Shi, W., Shi, N., Han, M., Xue, Z., Shen, D., & Shi, Y.
Venue
Medical Physics
Publisher
Wiley
Published
2021-03-09
Volume
48
Issue
4
Pages
1633-1645
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W3108672867
Cited by
205
References
12
FWCI
17.15
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.