The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla
Open accessAbstract
High‐field arterial spin labeling (ASL) perfusion MRI is appealing because it provides not only increased signal‐to‐noise ratio (SNR), but also advantages in terms of labeling due to the increased relaxation time T1 of labeled blood. In the present study, we provide a theoretical framework for the dependence of the ASL signal on the static field strength, followed by experimental validation in which a multislice pulsed ASL (PASL) technique was carried out at 4T and compared with PASL and continuous ASL (CASL) techniques at 1.5T, both in the resting state and during motor activation. The resting‐state data showed an SNR ratio of 2.3:1.4:1 in the gray matter and a contrast‐to‐noise ratio (CNR) of 2.7:1.1:1 between the gray and white matter for the difference perfusion images acquired using 4T PASL, 1.5T CASL, and 1.5T PASL, respectively. However, the functional data acquired using 4T PASL did not show significantly improved sensitivity to motor cortex activation compared with the 1.5T functional data, with reduced fractional perfusion signal change and increased intersubject variability. Possible reasons for these experimental results, including susceptibility effects and physiological noise, are discussed. Magn Reson Med 48:242–254, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
AFNI: Software for analysis and visualization of functional magnetic resonance neuroimages
Cox, R. W. (1996) · Computers and Biomedical Research · doi:10.1006/cbmr.1996.0014 · Cited by 10,913
Detre, J. A., Leigh, J. S., Williams, D. S., & Koretsky, A. P. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230106 · Cited by 1,571
Self-citationMagnetic resonance imaging of perfusion using spin inversion of arterial water.
Williams, D. S., Detre, J. A., Leigh, J. S., & Koretsky, A. P. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.212 · Cited by 1,546
Self-citationA general kinetic model for quantitative perfusion imaging with arterial spin labeling
Buxton, R. B., Frank, L. R., Wong, E. C., Siewert, B., Warach, S., & Edelman, R. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400308 · Cited by 1,263
CEREBRAL BLOOD FLOW, BLOOD VOLUME AND OXYGEN UTILIZATION: NORMAL VALUES AND EFFECT OF AGE
LEENDERS, K. L., PERANI, D., LAMMERTSMA, A. A., HEATHER, J. D., BUCKINGHAM, P., JONES, T., HEALY, M. J. R., GIBBS, J. M., WISE, R. J. S., HATAZAWA, J., et al. (1990) · Brain · doi:10.1093/brain/113.1.27 · Cited by 1,093
Kim, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340303 · Cited by 1,001
Alsop, D. C., & Detre, J. A. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199611000-00019 · Cited by 754
Self-citationEdelman, R. R., Siewert, B., Darby, D. G., Thangaraj, V, Nobre, A. C., Mesulam, M. M., & Warach, S. (1994) · Radiology · doi:10.1148/radiology.192.2.8029425 · Cited by 700
Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II)
Wong, E. C., Buxton, R. B., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390506 · Cited by 689
Regional cerebral blood flow during voluntary arm and hand movements in human subjects
Colebatch, J. G., Deiber, M. P., Passingham, R. E., Friston, K. J., & Frackowiak, R. S. (1991) · Journal of Neurophysiology · doi:10.1152/jn.1991.65.6.1392 · Cited by 603
Chalela, J. A., Alsop, D. C., Gonzalez-Atavales, J. B., Maldjian, J. A., Kasner, S. E., & Detre, J. A. (2000) · Stroke · doi:10.1161/01.str.31.3.680 · Cited by 481
Self-citationMr perfusion studies with t1‐weighted echo planar imaging
Kwong, K. K., Chesler, D. A., Weisskoff, R. M., Donahue, K. M., Davis, T. L., Ostergaard, L., Campbell, T. A., & Rosen, B. R. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340613 · Cited by 477
A review of 1H nuclear magnetic resonance relaxation in pathology: Are T1 and T2 diagnostic?
Bottomley, P. A., Hardy, C. J., Argersinger, R. E., & Allen‐Moore, G. (1987) · Medical Physics · doi:10.1118/1.596111 · Cited by 471
Menon, R. S., Ogawa, S., Tank, D. W., & Uǧurbil, K. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300317 · Cited by 413
Assessment of cerebral blood flow in Alzheimer's disease by spin-labeled magnetic resonance imaging
Alsop, D. C., Detre, J. A., & Grossman, M. (2000) · Annals of Neurology · doi:10.1002/1531-8249(200001)47:1<93::aid-ana15>3.0.co;2-8 · Cited by 409
Self-citationMultisection cerebral blood flow MR imaging with continuous arterial spin labeling.
Alsop, D. C., & Detre, J. A. (1998) · Radiology · doi:10.1148/radiology.208.2.9680569 · Cited by 404
Self-citationExperimental design and the relative sensitivity of BOLD and perfusion fMRI
Aguirre, G. K., Detre, J. A., Zarahn, E., & Alsop, D. C. (2002) · NeuroImage · doi:10.1006/nimg.2001.0990 · Cited by 403
Self-citationNeuroimaging at 1.5 T and 3.0 T: Comparison of oxygenation‐sensitive magnetic resonance imaging
Krüger, G., Kastrup, A., & Glover, G. H. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1081 · Cited by 325
Ye, F. Q., Frank, J. A., Weinberger, D. R., & McLaughlin, A. C. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200007)44:1<92::aid-mrm14>3.0.co;2-m · Cited by 309
Ye, F. Q., Mattay, V. S., Jezzard, P., Frank, J. A., Weinberger, D. R., & McLaughlin, A. C. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370215 · Cited by 294
Wong, E. C., Buxton, R. B., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400303 · Cited by 250
Noninvasive MRI evaluation of cerebral blood flow in cerebrovascular disease
Detre, J. A., Alsop, D. C., Vives, L. R., Maccotta, L., Teener, J. W., & Raps, E. C. (1998) · Neurology · doi:10.1212/wnl.50.3.633 · Cited by 209
Self-citationMultislice imaging of quantitative cerebral perfusion with pulsed arterial spin labeling
Yang, Y., Frank, J. A., Hou, L., Ye, F. Q., McLaughlin, A. C., & Duyn, J. H. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390520 · Cited by 155
Multislice perfusion and perfusion territory imaging in humans with separate label and image coils
Zaharchuk, G., Ledden, P. J., Kwong, K. K., Reese, T. G., Rosen, B. R., & Wald, L. L. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199906)41:6<1093::aid-mrm4>3.0.co;2-0 · Cited by 141
Luh, W., Wong, E. C., Bandettini, P. A., Ward, B. D., & Hyde, J. S. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200007)44:1<137::aid-mrm20>3.0.co;2-r · Cited by 136
Liu, H., Kochunov, P., Hou, J., Pu, Y., Mahankali, S., Feng, C., Yee, S.-H., Wan, Y., Fox, P. T., & Gao, J. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200103)45:3<431::aid-mrm1056>3.0.co;2-e · Cited by 68
Accurate T1 determination from inversion recovery images: Application to human brain at 4 Tesla
Kim, S., Hu, X. P., & Uǧurbil, K. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310414 · Cited by 66
Yongbi, M. N., Yang, Y., Frank, J. A., & Duyn, J. H. (1999) · Magnetic Resonance in Medicine · Cited by 62
Comparison of 3D BOLD Functional MRI with Spiral Acquisition at 1.5 and 4.0 T
Yang, Y., Wen, H., Mattay, V. S., Balaban, R. S., Frank, J. A., & Duyn, J. H. (1999) · NeuroImage · doi:10.1006/nimg.1998.0422 · Cited by 52
STAR‐HASTE: Perfusion imaging without magnetic susceptibility artifact
Chen, Q., Siewert, B., Bly, B. M., Warach, S. J., & Edelman, R. R. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380308 · Cited by 50
Ewing, J. R., Cao, Y., & Fenstermacher, J. D. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1215 · Cited by 46
Potential and Pitfalls of Arterial Spin Labeling Based Perfusion Imaging Techniques for MRI
Wong, E. C. (2000) · Medical radiology · doi:10.1007/978-3-642-58716-0_6 · Cited by 40
Perfusion-based functional magnetic resonance imaging with single-shot RARE and GRASE acquisitions
Crelier, G. R., Hoge, R. D., Munger, P., & Pike, G. B. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199901)41:1<132::aid-mrm18>3.0.co;2-5 · Cited by 33
Perfusion fMRI with Arterial Spin Labeling
Detre, J. A., & Alsop, D. C. (2000) · Medical radiology · doi:10.1007/978-3-642-58716-0_5 · Cited by 28
Self-citationGrieve (2000) · doi:10.1002/(sici)1522-2594(200005)43:5
Cited by
Alsop, D. C., Detre, J. A., Golay, X., Günther, M., Hendrikse, J., Hernandez‐Garcia, L., Lu, H., MacIntosh, B. J., Parkes, L. M., Smits, M., et al. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25197 · Cited by 2,206
Self-citationComparative Overview of Brain Perfusion Imaging Techniques
Wintermark, M., Sesay, M., Barbier, E., Borbély, K., Dillon, W. P., Eastwood, J. D., Glenn, T. C., Grandin, C. B., Pedraza, S., Soustiel, J.-F., et al. (2005) · Stroke · doi:10.1161/01.str.0000177884.72657.8b · Cited by 592
Empirical optimization of ASL data analysis using an ASL data processing toolbox: ASLtbx
Wang, Z., Aguirre, G. K., Rao, H., Wang, J., Fernández-Seara, M. A., Childress, A. R., & Detre, J. A. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.07.003 · Cited by 477
Self-citationWu, W., Fernández‐Seara, M., Detre, J. A., Wehrli, F. W., & Wang, J. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21403 · Cited by 465
Self-citationPerfusion MRI: The Five Most Frequently Asked Technical Questions
Essig, M., Shiroishi, M. S., Nguyen, T. B., Saake, M., Provenzale, J. M., Enterline, D., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9543 · Cited by 366
Metadata
- Authors
- Wang, J., Alsop, D. C., Li, L., Listerud, J., Gonzalez‐At, J. B., Schnall, M. D., & Detre, J. A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-07-31
- Volume
- 48
- Issue
- 2
- Pages
- 242-254
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2154535553
- Cited by
- 369
- References
- 35
- FWCI
- 13.56
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.