The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Spin‐echo fMRI in humans using high spatial resolutions and high magnetic fields
Open accessAbstract
The Hahn spin‐echo (HSE)‐based BOLD effect at high magnetic fields is expected to provide functional images that originate exclusively from the microvasculature. The blood contribution that dominates HSE BOLD contrast at low magnetic fields (e.g., 1.5 T), and degrades specificity, is highly attenuated at high fields because the apparent T2 of venous blood in an HSE experiment decreases quadratically with increasing magnetic field. In contrast, the HSE BOLD contrast is believed to arise from the microvasculature and increase supralinearly with the magnetic field strength. In this work we report the results of detailed and quantitative evaluations of HSE BOLD signal changes for functional imaging in the human visual cortex at 4 and 7 T. This study used high spatial resolution, afforded by the increased signal‐to‐noise ratio (SNR) of higher field strengths and surface coils, to avoid partial volume effects (PVEs), and demonstrated increased contrast‐to‐noise ratio (CNR) and spatial specificity at the higher field strengths. The HSE BOLD signal changes induced by visual stimulation were predominantly linearly dependent on the echo time (TE). They increased in magnitude almost quadratically in going from 4 to 7 T when the blood contribution was suppressed using Stejskal‐Tanner gradients that suppress signals from the blood due to its inhomogeneous flow and higher diffusion constant relative to tissue. The HSE signal changes at 7 T were modeled accurately using a vascular volume of 1.5%, in agreement with the capillary volume of gray matter. Furthermore, high‐resolution acquisitions indicate that CNR increased with voxel sizes < 1 mm 3 due to diminishing white matter or cerebrospinal fluid‐space vs. gray matter PVEs. It was concluded that the high‐field HSE functional MRI (fMRI) signals originated largely from the capillaries, and that the magnitude of the signal changes associated with brain function reached sufficiently high levels at 7 T to make it a useful approach for mapping on the millimeter to submillimeter spatial scale. Magn Reson Med 49:655–664, 2003. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Magnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Self-citationProcessing strategies for time‐course data sets in functional mri of the human brain
Bandettini, P. A., Jesmanowicz, A., Wong, E. C., & Hyde, J. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300204 · Cited by 1,763
Analysis of functional MRI time‐series
Friston, K. J., Jezzard, P., & Turner, R. (1994) · Human Brain Mapping · doi:10.1002/hbm.460010207 · Cited by 1,682
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Malonek, D., & Grinvald, A. (1996) · Science · doi:10.1126/science.272.5261.551 · Cited by 1,097
Mr contrast due to intravascular magnetic susceptibility perturbations
Boxerman, J. L., Hamberg, L. M., Rosen, B. R., & Weisskoff, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340412 · Cited by 1,008
Boxerman, J. L., Bandettini, P. A., Kwong, K. K., Baker, J. R., Davis, T. L., Rosen, B. R., & Weisskoff, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340103 · Cited by 594
Field mapping without reference scan using asymmetric echo-planar techniques
Gruetter, R., & Tk�?, I. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200002)43:2<319::aid-mrm22>3.0.co;2-1 · Cited by 569
Ogawa, S., & Lee, T. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160103 · Cited by 565
Imaging brain function in humans at 7 Tesla
Yacoub, E., Shmuel, A., Pfeuffer, J., Van De Moortele, P., Adriany, G., Andersen, P., Vaughan, J. T., Merkle, H., Ugurbil, K., & Hu, X. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1080 · Cited by 448
Self-citationMenon, R. S., Ogawa, S., Tank, D. W., & Uǧurbil, K. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300317 · Cited by 413
Self-citationHigh-resolution mapping of iso-orientation columns by fMRI
Kim, D.-S., Duong, T. Q., & Kim, S.-G. (2000) · Nature Neuroscience · doi:10.1038/72109 · Cited by 393
Self-citationFisel, C. R., Ackerman, J. L., Buxton, R. B., Garrido, L., Belliveau, J. W., Rosen, B. R., & Brady, T. J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170206 · Cited by 356
Brain or veinoxygenation or flow? On signal physiology in functional MRI of human brain activation
Frahm, J., Merboldt, K., Hänicke, W., Kleinschmidt, A., & Boecker, H. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070108 · Cited by 342
Localized cerebral blood flow response at submillimeter columnar resolution
Duong, T. Q., Kim, D.-S., Uğurbil, K., & Kim, S.-G. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.191101098 · Cited by 342
Self-citationStimulate: A GUI based fMRI analysis software package
Strupp, J. P. (1996) · NeuroImage · doi:10.1016/s1053-8119(96)80609-4 · Cited by 325
Pawlik, G., Rackl, A., & Bing, R. J. (1981) · Brain Research · doi:10.1016/0006-8993(81)90619-3 · Cited by 311
Diffusion-weighted spin-echo fMRI at 9.4 T: Microvascular/tissue contribution to BOLD signal changes
Lee, S.-P., Silva, A. C., Ugurbil, K., & Kim, S.-G. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<919::aid-mrm12>3.0.co;2-8 · Cited by 288
Self-citationInflow versus deoxyhemoglobin effects in bold functional MRI using gradient echoes at 1.5 T
Duyn, J. H., Moonen, C. T. W., van Yperen, G. H., de Boer, R. W., & Luyten, P. R. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070113 · Cited by 229
Diffusion weighted fMRI at 1.5 T
Song, A. W., Wong, E. C., Tan, S. G., & Hyde, J. S. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350204 · Cited by 208
Duong, T. Q., Kim, D.-S., U?urbil, K., & Kim, S.-G. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200008)44:2<231::aid-mrm10>3.0.co;2-t · Cited by 182
Self-citationFunctional mapping in the human brain using high magnetic fields
Uǧurbil, K., Hu, X. P., Chen, W., Zhu, X.-H., Kim, S., & Georgopoulos, A. P. (1999) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.1999.0474 · Cited by 159
Self-citationHigh‐resolution, spin‐echo BOLD, and CBF fMRI at 4 and 7 T
Duong, T. Q., Yacoub, E. S., Adriany, G., Hu, X. P., Uǧurbil, K., Vaughan, J. T., Merkle, H., & Kim, S. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10252 · Cited by 146
Self-citationHigh‐resolution fMRI using multislice partial k‐space GR‐EPI with cubic voxels
Hyde, J. S., Biswal, B. B., & Jesmanowicz, A. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1166 · Cited by 145
Luh, W., Wong, E. C., Bandettini, P. A., Ward, B. D., & Hyde, J. S. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200007)44:1<137::aid-mrm20>3.0.co;2-r · Cited by 136
Norris, D. G., Zysset, S., Mildner, T., & Wiggins, C. J. (2002) · NeuroImage · doi:10.1006/nimg.2001.1005 · Cited by 131
Perfusion‐based high‐resolution functional imaging in the human brain at 7 Tesla
Pfeuffer, J., Adriany, G., Shmuel, A., Yacoub, E. S., de Moortele, P. V., Hu, X. P., & Uǧurbil, K. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10154 · Cited by 125
Self-citationInvestigation of the initial dip in fMRI at 7 Tesla
Yacoub, E. S., Shmuel, A., Pfeuffer, J., de Moortele, P. V., Adriany, G., Uǧurbil, K., & Hu, X. P. (2001) · NMR in Biomedicine · doi:10.1002/nbm.715 · Cited by 121
Self-citationProton NMR relaxation times of human blood samples at 1.5 T and implications for functional MRI.
Barth, M., & Moser, E. (1997) · PubMed · Cited by 118
Bartha, R., Michaeli, S., Merkle, H., Adriany, G., Andersen, P., Chen, W., Uǧurbil, K., & Garwood, M. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10112 · Cited by 116
Self-citationVenous blood effects in spin-echo fMRI of human brain
Oja, J. M. E., Gillen, J., Kauppinen, R. A., Kraut, M. A., & van Zijl, P. C. M. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199910)42:4<617::aid-mrm1>3.0.co;2-q · Cited by 113
Quantitative differentiation between BOLD models in fMRI
Hoogenraad, F. G. C., Pouwels, P. J. W., Hofman, M. B. M., Reichenbach, J. R., Sprenger, M., & Haacke, E. M. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200102)45:2<233::aid-mrm1032>3.0.co;2-w · Cited by 105
T1 and T2 measurements on a 1.5-T commercial MR imager.
Breger, R. K., Rimm, A. A., Fischer, M., Papke, R. A., & Haughton, V. M. (1989) · Radiology · doi:10.1148/radiology.171.1.2928538 · Cited by 104
Functional NMR imaging using fast spin echo at 1.5 T
Constable, R. T., Kennan, R. P., Puce, A., McCarthy, G., & Gore, J. C. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310617 · Cited by 88
Fujita, N. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1251 · Cited by 69
Localized echo‐volume imaging methods for functional MRI
Yang, Y., Mattay, V. S., Weinberger, D. R., Frank, J. A., & Duyn, J. H. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070220 · Cited by 34
Fast spin‐echo characteristics of visual stimulation‐induced signal changes in the human brain
Gao, J., Xiong, J., Li, J., Schiff, J., Roby, J. W., Lancaster, J. L., & Fox, P. T. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050615 · Cited by 27
Cited by
Representational similarity analysis-connecting the branches of systems neuroscience
Kriegeskorte, N. (2008) · Frontiers in Systems Neuroscience · doi:10.3389/neuro.06.004.2008 · Cited by 3,355
Uğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Self-citationBiophysical and Physiological Origins of Blood Oxygenation Level-Dependent fMRI Signals
Kim, S.-G., & Ogawa, S. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.23 · Cited by 547
Self-citationPros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Simultaneous multislice (SMS) imaging techniques
Barth, M., Breuer, F., Koopmans, P. J., Norris, D. G., & Poser, B. A. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25897 · Cited by 534
Metadata
- Authors
- Yacoub, E., Duong, T. Q., Van De Moortele, P., Lindquist, M., Adriany, G., Kim, S., Uğurbil, K., & Hu, X.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2003-03-18
- Volume
- 49
- Issue
- 4
- Pages
- 655-664
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2096289837
- Cited by
- 308
- References
- 39
- FWCI
- 10.09
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.