Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 308

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

Spin‐echo fMRI in humans using high spatial resolutions and high magnetic fields

Open access
Yacoub, Essa, Duong, Timothy Q., Van De Moortele, Pierre‐Francois, Lindquist, Martin, Adriany, Gregor, Kim, Seong‐Gi, Uğurbil, Kâmil, Hu, Xiaoping · 2003 · Magnetic Resonance in Medicine

Abstract

The Hahn spin‐echo (HSE)‐based BOLD effect at high magnetic fields is expected to provide functional images that originate exclusively from the microvasculature. The blood contribution that dominates HSE BOLD contrast at low magnetic fields (e.g., 1.5 T), and degrades specificity, is highly attenuated at high fields because the apparent T2 of venous blood in an HSE experiment decreases quadratically with increasing magnetic field. In contrast, the HSE BOLD contrast is believed to arise from the microvasculature and increase supralinearly with the magnetic field strength. In this work we report the results of detailed and quantitative evaluations of HSE BOLD signal changes for functional imaging in the human visual cortex at 4 and 7 T. This study used high spatial resolution, afforded by the increased signal‐to‐noise ratio (SNR) of higher field strengths and surface coils, to avoid partial volume effects (PVEs), and demonstrated increased contrast‐to‐noise ratio (CNR) and spatial specificity at the higher field strengths. The HSE BOLD signal changes induced by visual stimulation were predominantly linearly dependent on the echo time (TE). They increased in magnitude almost quadratically in going from 4 to 7 T when the blood contribution was suppressed using Stejskal‐Tanner gradients that suppress signals from the blood due to its inhomogeneous flow and higher diffusion constant relative to tissue. The HSE signal changes at 7 T were modeled accurately using a vascular volume of 1.5%, in agreement with the capillary volume of gray matter. Furthermore, high‐resolution acquisitions indicate that CNR increased with voxel sizes < 1 mm 3 due to diminishing white matter or cerebrospinal fluid‐space vs. gray matter PVEs. It was concluded that the high‐field HSE functional MRI (fMRI) signals originated largely from the capillaries, and that the magnitude of the signal changes associated with brain function reached sufficiently high levels at 7 T to make it a useful approach for mapping on the millimeter to submillimeter spatial scale. Magn Reson Med 49:655–664, 2003. © 2003 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.10433

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 308

Metadata

Authors
Yacoub, E., Duong, T. Q., Van De Moortele, P., Lindquist, M., Adriany, G., Kim, S., Uğurbil, K., & Hu, X.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2003-03-18
Volume
49
Issue
4
Pages
655-664
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2096289837
Cited by
308
References
39
FWCI
10.09
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.