The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Simultaneous spatial and spectral selective excitation
Abstract
Using a k‐space interpretation of small‐tip excitation, a single excitation pulse has been designed that is simultaneously selective in space and resonant frequency. An analytic expression for the response of this pulse has been derived. The pulse has been implemented on a 1.5‐T imaging system. The pulse has been applied to a rapid gradient‐echo imaging sequence that forms both water and fat images within a breath‐holding interval. These rapid images are free of the chemical shift artifacts at organ boundaries that typically afflict conventional rapid images. The pulse can be applied to a variety of other sequences, such as multislice water/fat sequences and rapid k‐space scanning. © 1990 Academic Press, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
FLASH imaging: Rapid NMR imaging using low flip-angle pulses
Haase, A., Frahm, J., Matthaei, D., Hänicke, W., & Merboldt, K.-D. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.09.021 · Cited by 1,153
NMR chemical shift imaging in three dimensions.
Brown, T. R., Kincaid, B. M., & Ugurbil, K. (1982) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.79.11.3523 · Cited by 1,039
FLASH imaging. Rapid NMR imaging using low flip-angle pulses
Haase, A., Frahm, J., Matthaei, D., Hanicke, W., & Merboldt, K.-D. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90433-6 · Cited by 826
Brooker, H. R. (1983) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(83)90089-6 · Cited by 455
Twieg, D. B. (1983) · Medical Physics · doi:10.1118/1.595331 · Cited by 373
A simple graphical representation of fourier-based imaging methods
Ljunggren, S. (1983) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(83)90060-4 · Cited by 292
Optimal Control Solutions to the Magnetic Resonance Selective Excitation Problem
Conolly, S., Nishimura, D., & Macovski, A. (1986) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1986.4307754 · Cited by 278
Self-citation
Cited by
Fast Spiral Coronary Artery Imaging
Meyer, C. H., Hu, B. S., Nishimura, D. G., & Macovski, A. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910280204 · Cited by 866
Self-citationReeder, S. B., Pineda, A. R., Wen, Z., Shimakawa, A., Yu, H., Brittain, J. H., Gold, G. E., Beaulieu, C. H., & Pelc, N. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20624 · Cited by 706
Yu, H., Shimakawa, A., McKenzie, C. A., Brodsky, E., Brittain, J. H., & Reeder, S. B. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21737 · Cited by 694
Kurhanewicz, J., Vigneron, D. B., Brindle, K., Chekmenev, E. Y., Comment, A., Cunningham, C. H., DeBerardinis, R. J., Green, G. G., Leach, M. O., Rajan, S. S., et al. (2011) · Neoplasia · doi:10.1593/neo.101102 · Cited by 681
Physiological noise in oxygenation‐sensitive magnetic resonance imaging
Krüger, G., & Glover, G. H. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1240 · Cited by 629
Crema, M. D., Roemer, F. W., Marra, M. D., Burstein, D., Gold, G. E., Eckstein, F., Baum, T., Mosher, T. J., Carrino, J. A., & Guermazi, A. (2011) · RadioGraphics · doi:10.1148/rg.311105084 · Cited by 448
Positive contrast magnetic resonance imaging of cells labeled with magnetic nanoparticles
Cunningham, C. H., Arai, T., Yang, P. C., McConnell, M. V., Pauly, J. M., & Conolly, S. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20477 · Cited by 403
Self-citationMR Pulse Sequences: What Every Radiologist Wants to Know but Is Afraid to Ask
Bitar, R., Leung, G., Perng, R., Tadros, S., Moody, A. R., Sarrazin, J., McGregor, C., Christakis, M., Symons, S., Nelson, A., et al. (2006) · RadioGraphics · doi:10.1148/rg.262055063 · Cited by 383
Fat and water magnetic resonance imaging
Bley, T. A., Wieben, O., François, C. J., Brittain, J. H., & Reeder, S. B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21895 · Cited by 372
Fat-Suppression Techniques for 3-T MR Imaging of the Musculoskeletal System
Del Grande, F., Santini, F., Herzka, D. A., Aro, M. R., Dean, C. W., Gold, G. E., & Carrino, J. A. (2014) · RadioGraphics · doi:10.1148/rg.341135130 · Cited by 370
Water–fat separation with IDEAL gradient‐echo imaging
Reeder, S. B., McKenzie, C. A., Pineda, A. R., Yu, H., Shimakawa, A., Brau, A. C., Hargreaves, B. A., Gold, G. E., & Brittain, J. H. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20831 · Cited by 357
Hernando, D., Kellman, P., Haldar, J. P., & Liang, Z. ‐. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22177 · Cited by 336
Quantification of liver iron with MRI: State of the art and remaining challenges
Hernando, D., Levin, Y. S., Sirlin, C. B., & Reeder, S. B. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24584 · Cited by 280
A homogeneity correction method for magnetic resonance imaging with time-varying gradients
Noll, D. C., Meyer, C. H., Pauly, J. M., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.108599 · Cited by 277
Self-citationSingle-scan multidimensional magnetic resonance
Tal, A., & Frydman, L. (2010) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2010.04.001 · Cited by 277
Machann, J., Thamer, C., Schnoedt, B., Stefan, N., Haring, H., Claussen, C. D., Fritsche, A., & Schick, F. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20825 · Cited by 162
Machann, J., Bachmann, O. P., Brechtel, K., Dahl, D. B., Wietek, B., Klumpp, B., Häring, H., Claussen, C. D., Jacob, S., & Schick, F. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10255 · Cited by 73
Metadata
- Authors
- Meyer, C. H., Pauly, J. M., Macovskiand, A., & Nishimura, D. G.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1990-08
- Volume
- 15
- Issue
- 2
- Pages
- 287-304
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2151456335
- Cited by
- 498
- References
- 7
- FWCI
- 7.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.