The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Quantitative interpretation of magnetization transfer
Abstract
Magnetization transfer contrast (MTC) experiments using off‐resonance irradiation have been performed with an agar gel model by systematically varying offset frequency, amplitude of the RF irradiation and gel concentration. The experimental results are shown to be quantitatively modelled by a two‐pool system consisting of a liquid pool with a Lorentzian line shape and a small semisolid pool with a Gaussian lineshape. The fitted model yields physically realistic fundamental parameters with a T 2 of the semisolid pool of 13 μs. Further analysis shows that the off‐resonance irradiation MTC experiment has significant limitations in its ability to saturate the semisolid pool without directly affecting the liquid component.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Principles of Nuclear Magnetism
Abragam, A., & Hebel, L. C. (1961) · American Journal of Physics · doi:10.1119/1.1937646 · Cited by 15,792
Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo
Wolff, S. D., & Balaban, R. S. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910100113 · Cited by 1,482
Study of Moderately Rapid Chemical Exchange Reactions by Means of Nuclear Magnetic Double Resonance
Forsén, S., & Hoffman, R. A. (1963) · The Journal of Chemical Physics · doi:10.1063/1.1734121 · Cited by 1,222
Edzes, H. T., & Samulski, E. T. (1978) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(78)90185-3 · Cited by 375
Cross relaxation and spin diffusion in the proton NMR of hydrated collagen
Edzes, H. T., & Samulski, E. T. (1977) · Nature · doi:10.1038/265521a0 · Cited by 307
The Loss of Small Objects in Variable TE Imaging: Implications for FSE, RARE, and EPI
Constable, R. T., & Gore, J. C. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910280103 · Cited by 245
Quantitative 1H magnetization transfer imaging in vivo
Eng, J., Ceckler, T. L., & Balaban, R. S. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170203 · Cited by 236
Nuclear magnetic cross-relaxation spectroscopy
Grad, J., & Bryant, R. G. (1990) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(90)90361-c · Cited by 197
NMR imaging of labile proton exchange
Wolff, S. D., & Balaban, R. S. (1990) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(90)90220-4 · Cited by 143
Pulsed saturation transfer contrast
Hu, B. S., Conolly, S., Wright, G. A., Nishimura, D. G., & Macovski, A. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910260205 · Cited by 137
Cited by
T1, T2 relaxation and magnetization transfer in tissue at 3T
Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266
Self-citationChemical exchange saturation transfer (CEST): what is in a name and what isn't?
van Zijl, P. C. M., & Yadav, N. N. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22761 · Cited by 1,155
Magnetization transfer in MRI: a review
Henkelman, R. M., Stanisz, G. J., & Graham, S. J. (2001) · NMR in Biomedicine · doi:10.1002/nbm.683 · Cited by 921
Self-citationDiffusion tensor imaging of the corpus callosum in Autism
Alexander, A. L., Lee, J. E., Lazar, M., Boudos, R., DuBray, M. B., Oakes, T. R., Miller, J. N., Lu, J., Jeong, E.-K., McMahon, W. M., et al. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.08.032 · Cited by 595
Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation
Novikov, D. S., Fieremans, E., Jespersen, S. N., & Kiselev, V. G. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3998 · Cited by 581
Imaging cortical association tracts in the human brain using diffusion‐tensor‐based axonal tracking
Mori, S., Kaufmann, W. E., Davatzikos, C., Stieltjes, B., Amodei, L., Fredericksen, K., Pearlson, G. D., Melhem, E. R., Solaiyappan, M., Raymond, G. V., et al. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10074 · Cited by 557
Chemical exchange saturation transfer imaging and spectroscopy
Zhou, J., & Zijl, P. C. M. V. (2006) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2006.01.001 · Cited by 485
In vivo imaging of glucose uptake and metabolism in tumors
Walker-Samuel, S., Ramasawmy, R., Torrealdea, F., Rega, M., Rajkumar, V., Johnson, S. P., Richardson, S., Gonçalves, M., Parkes, H. G., Årstad, E., et al. (2013) · Nature Medicine · doi:10.1038/nm.3252 · Cited by 479
Anisotropy of NMR properties of tissues
Henkelman, R. M., Stanisz, G. J., Kim, J. K., & Bronskill, M. J. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320508 · Cited by 424
Self-citationQuantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI
Sled, J. G., & Pike, G. B. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1278 · Cited by 419
Perfusion MRI: The Five Most Frequently Asked Technical Questions
Essig, M., Shiroishi, M. S., Nguyen, T. B., Saake, M., Provenzale, J. M., Enterline, D., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9543 · Cited by 366
Non-invasive measurement of perfusion: a critical review of arterial spin labelling techniques
Petersen, E. T., Zimine, I., Ho, Y.-C. L., & Golay, X. (2006) · The British Journal of Radiology · doi:10.1259/bjr/67705974 · Cited by 352
Insights into brain microstructure from the T2 distribution
MacKay, A., Laule, C., Vavasour, I., Bjarnason, T., Kolind, S., & Mädler, B. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.12.037 · Cited by 347
Using high-resolution quantitative mapping of R1 as an index of cortical myelination
Lutti, A., Dick, F., Sereno, M. I., & Weiskopf, N. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.005 · Cited by 346
Perfusion MRI: The Five Most Frequently Asked Clinical Questions
Essig, M., Nguyen, T. B., Shiroishi, M. S., Saake, M., Provenzale, J. M., Enterline, D. S., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9544 · Cited by 344
van Zijl, P. C. M., Lam, W. W., Xu, J., Knutsson, L., & Stanisz, G. J. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.04.045 · Cited by 339
Self-citationHelms, G., Dathe, H., Kallenberg, K., & Dechent, P. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21732 · Cited by 332
Zaiss, M., & Bachert, P. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/r221 · Cited by 323
Nuts and bolts of chemical exchange saturation transfer MRI
Liu, G., Song, X., Chan, K. W. Y., & McMahon, M. T. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2899 · Cited by 318
Zaiss, M., Xu, J., Goerke, S., Khan, I. S., Singer, R. J., Gore, J. C., Gochberg, D. F., & Bachert, P. (2014) · NMR in Biomedicine · doi:10.1002/nbm.3054 · Cited by 316
A Model for Magnetization Transfer in Tissues
Morrison, C., & Mark Henkelman, R. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330404 · Cited by 305
Quantitative magnetic resonance imaging of brain anatomy and in vivo histology
Weiskopf, N., Edwards, L. J., Helms, G., Mohammadi, S., & Kirilina, E. (2021) · Nature Reviews Physics · doi:10.1038/s42254-021-00326-1 · Cited by 300
A neuroradiologist’s guide to arterial spin labeling MRI in clinical practice
Grade, M., Hernandez Tamames, J. A., Pizzini, F. B., Achten, E., Golay, X., & Smits, M. (2015) · Neuroradiology · doi:10.1007/s00234-015-1571-z · Cited by 298
In vivo histology of the myelin g-ratio with magnetic resonance imaging
Stikov, N., Campbell, J. S. W., Stroh, T., Lavelée, M., Frey, S., Novek, J., Nuara, S., Ho, M.-K., Bedell, B. J., Dougherty, R. F., et al. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.05.023 · Cited by 295
Zhou, J., Wilson, D. A., Sun, P. Z., Klaus, J. A., & van Zijl, P. C. M. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20048 · Cited by 293
Magnetization transfer imaging: practical aspects and clinical applications.
Wolff, S. D., & Balaban, R. S. (1994) · Radiology · doi:10.1148/radiology.192.3.8058919 · Cited by 291
Quantitative magnetic resonance of postmortem multiple sclerosis brain before and after fixation
Schmierer, K., Wheeler‐Kingshott, C. A. M., Tozer, D. J., Boulby, P. A., Parkes, H. G., Yousry, T. A., Scaravilli, F., Barker, G. J., Tofts, P. S., & Miller, D. H. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21487 · Cited by 281
“(28), with modifications by Ramani et al.”
Quantitative magnetization transfer imaging in postmortem multiple sclerosis brain
Schmierer, K., Tozer, D. J., Scaravilli, F., Altmann, D. R., Barker, G. J., Tofts, P. S., & Miller, D. H. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20984 · Cited by 273
Perfusion Imaging Using Arterial Spin Labeling
Golay, X., Hendrikse, J., & Lim, T. C. C. (2004) · Topics in Magnetic Resonance Imaging · doi:10.1097/00002142-200402000-00003 · Cited by 256
Iron, myelin, and the brain: neuroimaging meets neurobiology
Möller, H. E., Bossoni, L., Connor, J. R., Crichton, R. R., Does, M. D., Ward, R. J., Zecca, L., Zucca, F. A., & Ronen, I. (2019) · Trends in Neurosciences · doi:10.1016/j.tins.2019.03.009 · Cited by 207
Lazari, A., & Lipp, I. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.117744 · Cited by 197
Quantitative MRI and ultrastructural examination of the cuprizone mouse model of demyelination
Thiessen, J. D., Zhang, Y., Zhang, H., Wang, L., Buist, R., Del Bigio, M. R., Kong, J., Li, X., & Martin, M. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2992 · Cited by 148
MR properties of excised neural tissue following experimentally induced inflammation
Stanisz, G. J., Webb, S., Munro, C. A., Pun, T., & Midha, R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20008 · Cited by 138
Self-citationSo You Want to Image Myelin Using MRI: An Overview and Practical Guide for Myelin Water Imaging
Lee, J., Hyun, J., Lee, J., Choi, E., Shin, H., Min, K., Nam, Y., Kim, H. J., & Oh, S. (2021) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.27059 · Cited by 134
Janve, V. A., Zu, Z., Yao, S.-Y., Li, K., Zhang, F. L., Wilson, K. J., Ou, X., Does, M. D., Subramaniam, S., & Gochberg, D. F. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.02.034 · Cited by 119
Formalin tissue fixation biases myelin – sensitive MRI
Seifert, A. C., Umphlett, M., Hefti, M., Fowkes, M., & Xu, J. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27821 · Cited by 44
Grussu, F., Schneider, T., Yates, R. L., Zhang, H., Wheeler-Kingshott, C. A. M. G., DeLuca, G. C., & Alexander, D. C. (2016) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2016.08.002 · Cited by 26
Mole, J. P., Fasano, F., Evans, J., Sims, R., Hamilton, D. A., Kidd, E., & Metzler-Baddeley, C. (2020) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2020.06.014 · Cited by 20
Whittaker, H. T., Zhu, S., Di Curzio, D. L., Buist, R., Li, X.-M., Noy, S., Wiseman, F. K., Thiessen, J. D., & Martin, M. (2018) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2018.03.010 · Cited by 12
Magnetic Resonance Imaging of the Common Marmoset Head
Lee, V.-M., Burdett, N. G., Carpenter, T. A., Herrod, N. J., James, M. F., & Hall, L. D. (1998) · Alternatives to Laboratory Animals · doi:10.1177/026119299802600309 · Cited by 5
Magnetic resonance imaging techniques for monitoring glioma response to chemoradiotherapy
Lawrence, L. S. P., Maralani, P. J., Das, S., Sahgal, A., Stanisz, G. J., & Lau, A. Z. (2025) · Journal of Neuro-Oncology · doi:10.1007/s11060-024-04856-3 · Cited by 4
Self-citation
Metadata
- Authors
- Henkelman, R. M., Huang, X., Xiang, Q., Stanisz, G. J., Swanson, S. D., & Bronskill, M. J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1993-06
- Volume
- 29
- Issue
- 6
- Pages
- 759-766
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2107915383
- Cited by
- 734
- References
- 12
- FWCI
- 14.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.