The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Transmit and receive transmission line arrays for 7 Tesla parallel imaging
Open accessAbstract
Transceive array coils, capable of RF transmission and independent signal reception, were developed for parallel, 1 H imaging applications in the human head at 7 T (300 MHz). The coils combine the advantages of high‐frequency properties of transmission lines with classic MR coil design. Because of the short wavelength at the 1 H frequency at 300 MHz, these coils were straightforward to build and decouple. The sensitivity profiles of individual coils were highly asymmetric, as expected at this high frequency; however, the summed images from all coils were relatively uniform over the whole brain. Data were obtained with four‐ and eight‐channel transceive arrays built using a loop configuration and compared to arrays built from straight stripline transmission lines. With both the four‐ and the eight‐channel arrays, parallel imaging with sensitivity encoding with high reduction numbers was feasible at 7 T in the human head. A one‐dimensional reduction factor of 4 was robustly achieved with an average g value of 1.25 with the eight‐channel transmit/receive coils. Magn Reson Med 53:434–445, 2005. © 2005 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pozar, D. M. (1990) · Cited by 8,065
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Self-citation(1963) · Journal of the Franklin Institute · doi:10.1016/0016-0032(63)90675-6 · Cited by 5,770
Roemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890
Self-citationThe intrinsic signal-to-noise ratio in NMR imaging
Edelstein, W. A., Glover, G. H., Hardy, C. J., & Redington, R. W. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030413 · Cited by 758
Katscher, U., Börnert, P., Leussler, C., & van den Brink, J. S. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10353 · Cited by 719
Signal‐to‐noise measurements in magnitude images from NMR phased arrays
Constantinides, C. D., Atalar, E., & McVeigh, E. R. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380524 · Cited by 510
High frequency volume coils for clinical NMR imaging and spectroscopy
Vaughan, J. T., Hetherington, H. P., Otu, J. O., Pan, J. W., & Pohost, G. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320209 · Cited by 374
Spin‐echo fMRI in humans using high spatial resolutions and high magnetic fields
Yacoub, E., Duong, T. Q., Van De Moortele, P., Lindquist, M., Adriany, G., Kim, S., Uğurbil, K., & Hu, X. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10433 · Cited by 308
Self-citationAnalysis of wave behavior in lossy dielectric samples at high field
Yang, Q. X., Wang, J., Zhang, X., Collins, C. M., Smith, M. B., Liu, H., Zhu, X., Vaughan, J. T., Ugurbil, K., & Chen, W. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10137 · Cited by 255
Self-citationMicrostrip RF surface coil design for extremely high‐field MRI and spectroscopy
Zhang, X., Ugurbil, K., & Chen, W. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1212 · Cited by 199
Self-citationWiesinger, F., Van de Moortele, P., Adriany, G., De Zanche, N., Ugurbil, K., & Pruessmann, K. P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20281 · Cited by 198
Self-citationDesign of a SENSE‐optimized high‐sensitivity MRI receive coil for brain imaging
de Zwart, J. A., Ledden, P. J., Kellman, P., van Gelderen, P., & Duyn, J. H. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10169 · Cited by 192
Coupling and decoupling theory and its application to the MRI phased array
Lee, R. F., Giaquinto, R. O., & Hardy, C. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10186 · Cited by 184
Specific coil design for SENSE: A six-element cardiac array
Weiger, M., Pruessmann, K. P., Leussler, C. G., R�schmann, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · Cited by 183
Self-citationA transmit-only/receive-only (TORO) RF system for high-field MRI/MRS applications
Barberi, E. A., Gati, J. S., Rutt, B. K., & Menon, R. S. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200002)43:2<284::aid-mrm16>3.0.co;2-c · Cited by 158
Perfusion‐based high‐resolution functional imaging in the human brain at 7 Tesla
Pfeuffer, J., Adriany, G., Shmuel, A., Yacoub, E. S., de Moortele, P. V., Hu, X. P., & Uǧurbil, K. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10154 · Cited by 132
Self-citationCollins, C. M., Yang, Q., Wang, J. H., Zhang, X., Liu, H., Michaeli, S., Zhu, X. H., Adriany, G., Vaughan, J. T., Anderson, P., et al. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10153 · Cited by 131
Self-citationPlanar strip array (PSA) for MRI
Lee, R. F., Westgate, C. R., Weiss, R. G., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1090 · Cited by 83
Cited by
Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging
Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015710 · Cited by 1,296
Self-citationUğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Self-citationB1 destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil
Van de Moortele, P., Akgun, C., Adriany, G., Moeller, S., Ritter, J., Collins, C. M., Smith, M. B., Vaughan, J. T., & Uğurbil, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20708 · Cited by 468
Self-citationParallel magnetic resonance imaging
Larkman, D. J., & Nunes, R. G. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/7/r01 · Cited by 327
Metzger, G. J., Snyder, C., Akgun, C., Vaughan, T., Ugurbil, K., & Van de Moortele, P. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21476 · Cited by 319
Self-citation
Metadata
- Authors
- Adriany, G., Van de Moortele, P., Wiesinger, F., Moeller, S., Strupp, J. P., Andersen, P., Snyder, C., Zhang, X., Chen, W., Pruessmann, K. P., Boesiger, P., Vaughan, T., & Uğurbil, K.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2005-01-27
- Volume
- 53
- Issue
- 2
- Pages
- 434-445
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1974110903
- Cited by
- 421
- References
- 21
- FWCI
- 13.09
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.