The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
A theoretical and experimental investigation of the tagging efficiency of pseudocontinuous arterial spin labeling
Abstract
Arterial spin labeling (ASL) is capable of noninvasively measuring blood flow by magnetically tagging the protons in arterial blood, which has been conventionally achieved using instantaneous (PASL) or continuous (CASL) RF pulses. As an intermediate method, pseudocontinuous ASL (pCASL) utilizes a train of discrete RF pulses to mimic continuous tagging that is often unavailable on imagers due to the requirement of continuous RF transmit capabilities. In the present study, we implemented two versions of pCASL (balanced and unbalanced gradient waveforms in tag and control scans) for both transmit/receive coils and array receivers. Experimental data show a 50% ± 4% increase of signal‐to‐noise ratio (SNR) compared with PASL and a higher tagging efficiency than amplitude‐modulated (AM) CASL (80% vs. 68%). Computer simulations predict an optimal tagging efficiency of 85% for flow velocities from 10 to 60 cm/s. It is theoretically and experimentally demonstrated that the tagging efficiency of pCASL is dependent upon the resonance offset and flip angle of the RF pulse train. We conclude that pCASL has the potential of combining the merits of PASL, including less hardware demand and higher tagging efficiency, and CASL, which includes a longer tagging bolus and thus higher SNR. These improvements provide a better balance between tagging efficiency and SNR. Magn Reson Med 58:1020–1027, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detre, J. A., Leigh, J. S., Williams, D. S., & Koretsky, A. P. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230106 · Cited by 1,571
Self-citationMagnetic resonance imaging of perfusion using spin inversion of arterial water.
Williams, D. S., Detre, J. A., Leigh, J. S., & Koretsky, A. P. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.212 · Cited by 1,546
Self-citationKim, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340303 · Cited by 1,001
Alsop, D. C., & Detre, J. A. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199611000-00019 · Cited by 754
Self-citationEdelman, R. R., Siewert, B., Darby, D. G., Thangaraj, V, Nobre, A. C., Mesulam, M. M., & Warach, S. (1994) · Radiology · doi:10.1148/radiology.192.2.8029425 · Cited by 700
Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II)
Wong, E. C., Buxton, R. B., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390506 · Cited by 689
Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla
Lu, H., Clingman, C., Golay, X., & van Zijl, P. C. M. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20178 · Cited by 685
Wong, E. C., Buxton, R. B., & Frank, L. R. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199706/08)10:4/5<237::aid-nbm475>3.0.co;2-x · Cited by 584
Mr perfusion studies with t1‐weighted echo planar imaging
Kwong, K. K., Chesler, D. A., Weisskoff, R. M., Donahue, K. M., Davis, T. L., Ostergaard, L., Campbell, T. A., & Rosen, B. R. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340613 · Cited by 477
Introduction to functional magnetic resonance imaging principles and techniques
Buxton, R. B. (2003) · Cited by 451
Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla
Wang, J., Alsop, D. C., Li, L., Listerud, J., Gonzalez‐At, J. B., Schnall, M. D., & Detre, J. A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10211 · Cited by 369
Self-citationWarmuth, C., Günther, M., & Zimmer, C. (2003) · Radiology · doi:10.1148/radiol.2282020409 · Cited by 364
Ye, F. Q., Berman, K. F., Ellmore, T., Esposito, G., van Horn, J. D., Yang, Y., Duyn, J., Smith, A. M., Frank, J. A., Weinberger, D. R., et al. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200009)44:3<450::aid-mrm16>3.0.co;2-0 · Cited by 317
Wang, J., Zhang, Y., Wolf, R. L., Roc, A. C., Alsop, D. C., & Detre, J. A. (2005) · Radiology · doi:10.1148/radiol.2351031663 · Cited by 271
Self-citationWong, E. C., Buxton, R. B., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400303 · Cited by 250
Introduction to Functional Magnetic Resonance Imaging: Principles and Techniques
Buxton, R. B. (2002) · Cambridge University Press eBooks · doi:10.1017/cbo9780511549854 · Cited by 229
Vessel‐encoded arterial spin‐labeling using pseudocontinuous tagging
Wong, E. C. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21293 · Cited by 221
Comparison of the dependence of blood R2 and R on oxygen saturation at 1.5 and 4.7 Tesla
Silvennoinen, M. J., Clingman, C. S., Golay, X., Kauppinen, R. A., & van Zijl, P. C. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10355 · Cited by 219
Perfusion imaging with compensation for asymmetric magnetization transfer effects
Pekar, J. J., Jezzard, P., Roberts, D. A., Leigh, J. S., Frank, J. A., & McLaughlin, A. C. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350110 · Cited by 162
Golay, X., Stuber, M., Pruessmann, K. P., Meier, D., & Boesiger, P. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199903)9:3<454::aid-jmri14>3.0.co;2-b · Cited by 105
Donahue, M. J., Lu, H., Jones, C. K., Pekar, J. J., & van Zijl, P. C. M. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1075 · Cited by 95
Radioactive microsphere validation of a volume localized continuous saturation perfusion measurement
Walsh, E. G., Minematsu, K., Leppo, J. A., & Moore, S. C. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310208 · Cited by 87
Functional brain imaging using a blood oxygenation sensitive steady state
Miller, K. L., Hargreaves, B. A., Lee, J., Ress, D. B., deCharms, R. C., & Pauly, J. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10602 · Cited by 85
Ye, F. Q., Smith, A. M., Yang, Y., Duyn, J. H., Mattay, V. S., Ruttimann, U. E., Frank, J. A., Weinberger, D. R., & McLaughlin, A. C. (1997) · NeuroImage · doi:10.1006/nimg.1997.0282 · Cited by 63
Quantification of cerebral blood flow by bolus tracking and artery spin tagging methods
Li, T., Chen, Z. G., Østergaard, L., Hindmarsh, T., & Moseley, M. E. (2000) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(00)00137-5 · Cited by 55
Cited by
Alsop, D. C., Detre, J. A., Golay, X., Günther, M., Hendrikse, J., Hernandez‐Garcia, L., Lu, H., MacIntosh, B. J., Parkes, L. M., Smits, M., et al. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25197 · Cited by 2,206
Self-citationDai, W., Garcia, D., de Bazelaire, C., & Alsop, D. C. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21790 · Cited by 985
Neuroimaging of the Philadelphia Neurodevelopmental Cohort
Satterthwaite, T. D., Elliott, M. A., Ruparel, K., Loughead, J., Prabhakaran, K., Calkins, M. E., Hopson, R., Jackson, C., Keefe, J., Riley, M., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.07.064 · Cited by 504
Harms, M. P., Somerville, L. H., Ances, B. M., Andersson, J., Barch, D. M., Bastiani, M., Bookheimer, S. Y., Brown, T. B., Buckner, R. L., Burgess, G. C., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.09.060 · Cited by 584
Lim, J., Wu, W.-C., Wang, J., Detre, J. A., Dinges, D. F., & Rao, H. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.11.020 · Cited by 418
Self-citation
Metadata
- Authors
- Wu, W., Fernández‐Seara, M., Detre, J. A., Wehrli, F. W., & Wang, J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2007-10-29
- Volume
- 58
- Issue
- 5
- Pages
- 1020-1027
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2109381172
- Cited by
- 465
- References
- 25
- FWCI
- 12.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.